ABSTRACT
Objective To evaluate the clinical application and safety of CT-guided pereutaneous transthoracic biopsy in the diagnosis of mediastinal masses.Methods Thirty three cases were undertaken CT- guided percutaneous transthoraeie biopsy with automatic biopsy gun and then the sampling specimens were undergone histological examination.The accuracy of puncture,diagnostic correctness and complications were analyzed.Results The operations were performed successfully in all 33 cases(100%),the definite pathologic diagnosis were made in 28 out of 33 cases(85%)and no complications occurred.Conclusion As for midiastinal masses,CT-guided percutaneous transthoracic biopsy is a feasible,successful,efficient interventional diagnostic method with high accuracy in localization,puncture,diagnosis and few complications, which should he recommended in clinical use more widely.(J Intervent Radiol,2007,16852-854)
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Tipo de estudo:
Estudo diagnóstico
Idioma:
Chinês
Revista:
Journal of Interventional Radiology
Ano de publicação:
2006
Tipo de documento:
Artigo