A modified hearing aid fitting procedure using both real ear and 2cc coupler measurement system
Yonsei Medical Journal
; : 202-205, 1997.
Artigo
em Inglês
| WPRIM (Pacífico Ocidental)
| ID: wpr-70664
Biblioteca responsável:
WPRO
ABSTRACT
In order to reduce the test time in real ear hearing-aid fitting for children, the validity of applying the average real ear to coupler differences (RECDs) in prefitting procedure using a 2cc coupler measurement system was evaluated by checking whether the majority of people's RECDs might occur within 5 dB of the average RECDs (N = 116) in each test frequency and age group. The percentages of occurrence were around 90% in test subjects' RECDs in saturation sound pressure levels (SSPLs) and around 70% in gain in each important test frequency. Appropriate test frequencies in prefitting are 500, 1000, 1500 and 2000 Hz.
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Assunto principal:
Otolaringologia
/
Fatores de Tempo
/
Adolescente
/
Ajuste de Prótese
/
Orelha
/
Auxiliares de Audição
/
Pessoa de Meia-Idade
Limite:
Adulto
/
Idoso
/
Criança
/
Criança, pré-escolar
/
Humanos
/
Lactente
Idioma:
Inglês
Revista:
Yonsei Medical Journal
Ano de publicação:
1997
Tipo de documento:
Artigo