Your browser doesn't support javascript.
loading
The dosimetric effect of inconsistency of bladder filling states between CT simulation and IMRT treatment for prostate cancer patients / 中华放射医学与防护杂志
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-745238
Biblioteca responsável: WPRO
ABSTRACT
Objective To analyze the dosimetric effect of inconsistent bladder filling states between the CT simulation and treatment for prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT).Methods A total of 42 prostate cancer patients treated with IMRT were selected.After vacuum pad immobilization and simulation CT scan,the delineation of targets and organs-at-risk (OARs),treatment planning and dose calculation were performed on treatment planning system (TPS).The cone-beam-CT (CBCT) acquired before the first treatment was registered to planning CT,on which the target contours were duplicated and OARs were delineated.After dose recalculation on the CBCT using the same plan,the dosimetric differences on the CT and CBCT were compared,including mean dose of the planning target volume (PTV),homogeneity index (HI),conformity index (CI);the mean dose,V30,V40,V50,V60,and V65 of bladder and rectum respectively.Results Relative to the bladder volumes at simulation,the patients were divided into two groups with larger (15 cases) or smaller (27 cases) bladders at the first treatment.Comparing the parameters obtained from simulation CT with that from CBCT,the differences of the following parameters were of statistical

significance:

the bladder volume,PTV HI,PTV CI in both groups (t =6.838,-4.372,-3.553,-3.462,6.380,5.037,P< 0.05),the bladder V30,V40,V50,V60,V65(t=-5.004,-4.092,-3.124,-2.707,-2.489,P <0.05) and rectal V40,V50,V60,V65,mean dose in the group with smaller bladders (t=-2.946,-2.643,-2.426,-3.127,-2.530,P < 0.05),and the bladder V30,V40,V50 and mean dose in group with larger bladders (t =5.107,4.204,3.777,4.155,P<0.05).Conclusions For prostate cancer patients undergoing IMRT,the inconsistent bladder filling states between the planning and treatment will cause disimetric differences of targets and OARs.

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2019 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2019 Tipo de documento: Artigo
...