Arteriovenous Fistula Dysfunction due to Stent Fracture in the Cephalic Arch / 대한신장학회지
Korean Journal of Nephrology
; : 407-410, 2010.
Article
em Ko
| WPRIM
| ID: wpr-74988
Biblioteca responsável:
WPRO
ABSTRACT
Stent placement is widely used for vascular access stenosis in hemodialysis patients as well as coronary artery stenosis. As its complication, stent fracture is not uncommon and causes restenosis after stent placement in coronary artery stenosis, but it has been rarely reported in venous stenosis of hemodialysis patients. Here we report a case of arteriovenous fistula dysfunction due to stent fracture in the cephalic arch of a hemodialysis patient.
Palavras-chave
Texto completo:
1
Base de dados:
WPRIM
Assunto principal:
Stents
/
Fístula Arteriovenosa
/
Diálise Renal
/
Constrição Patológica
/
Estenose Coronária
Limite:
Humans
Idioma:
Ko
Revista:
Korean Journal of Nephrology
Ano de publicação:
2010
Tipo de documento:
Article