Ultrasonic monitoring of carotid blood flow in interposed abdominal pulling-pressing cardiopulmonary resuscitation / 中华危重病急救医学
Chinese Critical Care Medicine
; (12): 691-694, 2018.
Article
em Zh
| WPRIM
| ID: wpr-806823
Biblioteca responsável:
WPRO
ABSTRACT
Objective@#To explore the difference in ultrasonic monitoring in carotid blood flow, resuscitation effects and prognosis between interposed abdominal pulling-pressing cardiopulmonary resuscitation (IAPP-CPR) and standard cardiopulmonary resuscitation (STD-CPR).@*Methods@#Seventy-five cardiac arrest (CA) patients admitted to emergency department of Shijingshan Teaching Hospital of Capital Medical University from June 2015 to December 2017 were enrolled. The patients were divided into STD-CPR group and IAPP-CPR group according to the treatment orders of them and the desire of relatives. All patients were given persistent external compression, airway open, tube intubation, and mechanical ventilation, vasoactive drugs application, defibrillation if required. STD-CPR group was operated according to the 2015 American Heart Association (AHA) CPR guidelines. On the basis of the standard CPR, IAPP-CPR group was recovered using abdominal lifting and compressing CPR instrument to press down to lift the upper abdomen continuously, when the chest compressing relaxed (frequency 100 times/min, down and lift time ratio 1:1, compressing strength 50 kg, lifting strength 30 kg). The patients' gender, age and CA etiology were recorded in the two groups. The vital signs and blood flow of carotid artery were monitored with ultrasonic Doppler during the CPR. The return of spontaneous circulation (ROSC) rate and 48-hour survival rate were observed in patients. The influence factors of ROSC were screened by Logistic regression analysis.@*Results@#The data of 75 patients with CA were enrolled finally, with STD-CPR group of 38 patients and IAPP-CPR group of 37 patients. There were no significant differences in patients' gender, age or CA etiology between the two groups. Comparing with STD-CPR group, the peak blood flow velocity of carotid artery in IAPP-CPR group was speeded up significantly (cm/s: 107.16±13.75 vs. 78.99±14.77, P < 0.01), the overall blood flow volume of carotid artery was increased significantly (mL/min: 989.06±115.88 vs. 751.62±118.92, P < 0.01), but there was no significant difference in inner diameter of carotid artery between the two groups (mm: 4.55±0.25 vs. 4.61±0.21, P > 0.05) . During the CPR, the mean arterial pressure (MAP) and the transcutaneous oxygen saturation (SpO2) in IAPP-CPR group were significantly higher than those of STD-CPR group, but no significant difference was found in heart rate between the two groups. Four patients in STD-CPR group got ROSC, and 3 survived over 48 hours (1 myocardial infarction patient died of ventricular fibrillation) while 6 patients in IAPP-CPR group got ROSC and survived over 48 hours. There was no significant difference in ROSC rate or 48-hour survival rate between the two groups, but data of IAPP-CPR group was slightly higher than that of STD-CPR group [ROSC rate: 16.22% (6/37) vs. 10.53% (4/38), 48-hour survival rate: 16.22% (6/37) vs. 7.89% (3/38), both P > 0.05]. Multivariate Logistic regression analysis showed that the higher the MAP during CPR, the greater the possibility of ROSC was [odds ratio (OR) = 1.361, 95% confidence interval (95%CI) = 1.182-1.669, P = 0.030].@*Conclusions@#IAPP-CPR was superior to traditional STD-CPR in improving arterial blood flow and resuscitation effect, but no superiority was found in ROSC rate and survival rate, which may be relate to the small number of patients that included in this study. More clinic trials are needed.
Texto completo:
1
Base de dados:
WPRIM
Tipo de estudo:
Guideline
/
Prognostic_studies
Idioma:
Zh
Revista:
Chinese Critical Care Medicine
Ano de publicação:
2018
Tipo de documento:
Article