Determination of the content of Gd3+ in gadoteric acid meglumine salt injection by ICP-MS method / 药学实践杂志
Journal of Pharmaceutical Practice
; (6): 124-128, 2020.
Artigo
em Chinês
| WPRIM (Pacífico Ocidental)
| ID: wpr-817800
Biblioteca responsável:
WPRO
ABSTRACT
Objective To establish a method for determining the content of Gd3+ in gadoteric acid meglumine salt injection. Methods ICP-MS was used. The separation column was a metal chelate column (1-ml Chelating Sepharose column), column temperature was normal temperature. Flow rate was 1 ml/min. Injection volume was 500 μl. Atoms were measured by ICP-MS with a molecular weight of 157 (The molecular weight of Gd was 157). The carrier gas was argon. Results The linear range of Gd3+ mass concentration was 0-500 ng/ml (r=1.000); The precision, stability and repeatability of the sample recovery test were all in accordance with the requirements. Conclusion The method was simple in operation, accurate in results and good in repeatability, which could be used to determine the content of Gd3+ in gadoteric acid meglumine salt injection.
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Idioma:
Chinês
Revista:
Journal of Pharmaceutical Practice
Ano de publicação:
2020
Tipo de documento:
Artigo