PURPOSE:

To evaluate the clinical features of high myopic eyes with cataracts implanted with negative power intraocular lenses (IOLs) at the time of cataract surgery.

METHODS:

A retrospective chart review was conducted of 18 eyes of 14 patients who underwent cataract surgery with negative power IOLs and 10 eyes in 9 patients with low power IOLs. We investigated axial length, IOL power, preoperative and postoperative best-corrected visual acuity (BCVA) and preoperative and postoperative spherical equivalent (SE) refractive errors.

RESULTS:

Mean BCVA showed significant improvement in both groups. We measured postoperative SE refraction and the difference between the mean intended and the mean achieved SE refractive errors in the negative power group (17 eyes) was +1.59 ± 1.34 D and +0.31 ± 0.50 D in the low power group.

CONCLUSIONS:

BCVA was significantly improved in the majority of eyes, although they had myopic macular degeneration or posterior staphyloma. However, the mean achieved postoperative SE refraction was more hyperopic than the predicted postoperative SE error. Additionally, hyperopic refractive error was greater in the negative power group than the low power group. Therefore, we recommend that postoperative hyperopic refractive error should be considered when performing cataract surgery in high myopic patients.
Assuntos

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Erros de Refração / Catarata / Extração de Catarata / Acuidade Visual / Estudos Retrospectivos / Implante de Lente Intraocular / Lentes Intraoculares / Degeneração Macular / Miopia Tipo de estudo: Estudo observacional Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2016 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Erros de Refração / Catarata / Extração de Catarata / Acuidade Visual / Estudos Retrospectivos / Implante de Lente Intraocular / Lentes Intraoculares / Degeneração Macular / Miopia Tipo de estudo: Estudo observacional Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2016 Tipo de documento: Artigo
...