Early experience with machine retrograde perfusion of deceased donor kidneys / 中华器官移植杂志
Chinese Journal of Organ Transplantation
; (12): 354-358, 2021.
Artigo
em Chinês
| WPRIM (Pacífico Ocidental)
| ID: wpr-911660
Biblioteca responsável:
WPRO
ABSTRACT
Objective:
To explore the safety and efficacy of retrograde machine perfusion of kidneys from deceased donors.Methods:
From January 1, 2020 to July 1, 24 renal transplant recipients underwent organ donation.All grafts were preserved by Kidney Transporter machines(LifePort). Through a random number table, they were divided into two groups of retrograde perfusion(RP group, 12 cases)and anterograde perfusion group(AP group, 12cases). The incidence of delayed recovery of kidney/graft function was compared between two groups.Results:
During a follow-up period of 1 month, kidney resistance remained stable in RP group during perfusion.No primary non-function occurred in neither groups.No inter-group difference existed in the incidence of delayed graft function (3 in RP and 2 in AP, P=0.62). At all timepoints within 30 days, both groups had comparable values of urine output, serum creatinine, estimated glomerular filtration rate, cystatin c and blood urea nitrogen.RP group with a resistance index of <0.4 had numerically better kidney function than those with a resistance index of ≥0.4.Conclusions:
This novel technique may be an effective and safe alternative for kidney preservation.
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Idioma:
Chinês
Revista:
Chinese Journal of Organ Transplantation
Ano de publicação:
2021
Tipo de documento:
Artigo