Article in English | AIM | ID: biblio-1268546

ABSTRACT

Introduction: capillary glucose measurement using point-of-care glucometers is an essential part of diabetes care. We determined the technical accuracy, clinical accuracy and precision of commonly available glucometers against standard spectrophotometry in Cameroon.Methods: a sample of four glucometers was selected. In the 108 diabetic and non-diabetic participants, blood glucose values obtained by glucometers were compared to the reference laboratory method to determine their technical and clinical accuracies. Precision was determined by repeated measurements using standard solutions of different concentrations.Results: accu-Chek® Active, CodeFree™, Mylife™ Pura™ and OneTouch® Ultra® 2 values had correlation coefficients of 0.96, 0.87, 0.97 and 0.94 respectively with reference values, and biases of 18.7%, 29.1%, 16.1% and 13.8% respectively. All glucometers had ≥ 95% of values located within the confidence limits except OneTouch® Ultra®2. Accu-Chek® Active, CodeFree™, Mylife™ Pura™ and OneTouch® Ultra® 2 had 99%, 93.1%, 100% and 98.0% of values in Parke's zones A and B. The coefficients of variation of the glucometers were all below 5% at all standard concentrations, except for Accu-Chek® Active for glucose concentrations at100 and 200mg/dL.Conclusion: no glucometer met all the international recommendations for technical accuracy. Accu-Chek™ Active and Mylife™, Pura™ met the International Organization for Standardization 2013 recommendations for clinical accuracy based on Parke's consensus error grid analysis. All glucometers assessed except Accu-Chek® Active showed a satisfactory level of precision at all concentrations of standard solutions used


Subject(s)
Africa South of the Sahara , Blood Glucose Self-Monitoring , Cross-Sectional Studies , Diabetes Mellitus/prevention & control , Hypoglycemic Agents
2.
Health sci. dis ; 17(2): 33-37, 2016.
Article in English | AIM | ID: biblio-1262760

ABSTRACT

BACKGROUND: Compliance with scheduled medical visit is an indirect indicator of the adherence to treatment.The aim of this study was to determine the incidence of non-compliance with scheduled medical visits and investigate the predictors and relationship with disease control among patient with asthma in the sub-Saharan African setting. METHODS: We conducted a prospective study between January 2012 and August 2013. All patients with asthma receiving care at the Yaounde Jamot Hospital and CEDIMER medical practice were included. Planned medical visit occurred at month one; three; six and twelve following baseline evaluation. Regression models were employed to investigate the predictors of non-compliance. RESULTS: 186 patients [121 (65.1%) being female] were included. Their median age (25th-75th percentiles) was 35.5 (20.0-52.3) years. A total of 67 (36%) failed to attend at least one of the scheduled visits. The proportion of patients who failed to comply with scheduled visits was 48.4%; 68.8%; 73.5% and 79.5% at month one; three; six and twelve respectively. The accompanying rates of unacceptable asthma control were 17.2%; 24.4% and 20.8% respectively at three; six and twelve months of follow-up. Inadequate asthma control at baseline was the main predictor of non-compliance with medical visits; with adjusted odds ratio ranging from 2.00 to 4.67. Furthermore; non-sensitisation to non-pollinic aeroallergens was associated with 2.79 (95%CI 1.58-6.07) risk of non-compliance at one month of follow-up. CONCLUSION: Targeting education of patients with poorly controlled disease at baseline can potentially improve adherence to medical visit and anti-asthmatic treatments and outcomes of care


Subject(s)
Asthma/prevention & control , Asthma/therapy , Cohort Studies , Patient Compliance
SELECTION OF CITATIONS
SEARCH DETAIL