West Afr. j. radiol ; 27(2): 75-80, 2020. ilus
Article in English | AIM | ID: biblio-1273555

ABSTRACT

Background: Measurement of optic nerve sheath diameter (ONSD) and anterior chamber depth (ACD) by ultrasound is increasingly used as a marker to detect raised intracranial pressure and other eye pathologies. Knowledge of normal ONSD and ACD in a healthy population is essential in the interpretation of pathological conditions.Aim: The study aimed at evaluating the ONSD and ACD of the eye in apparently healthy adults in Kano State.Materials and Methods: This was a prospective and cross-sectional study conducted among apparently healthy adults in Kano State from April 2019 to October 2019. Using convenience sampling method, 384 adults participated in the study. An ethical approval was obtained from the Human Research and Ethics Committee of the Kano State Ministry of Health, and informed consent was obtained from all the selected participants. A portable digital ultrasound machine, Nortek CS 3 with a 7.5 MHz linear transducer, was used to obtain ACD and ONSD at 3 mm behind the globe, and the values were recorded in data capture sheet. The obtained data were analyzed using SPSS version 23.0.Results: The mean and standard deviation of the right and left ONSDs for males was 4.42 ± 1.38 mm and 4.44 ± 1.41 mm and for the females was 4.39 ± 1.31 mm and 4.41 ± 1.31, respectively. The mean and standard deviation of the right and left ACDs for males was 3.16 ± 0.37 mm and 3.14 ± 0.35 mm and for females was 3.12 ± 0.40 mm and 3.11 ± 1.39 mm, respectively.Conclusion: The study has established normative values for the ONSD and ACD of the eye in Kano State, Nigeria


Subject(s)
Anterior Chamber , Nigeria
2.
West Afr. j. radiol ; 26(2): 90-93, 2019.
Article in English | AIM | ID: biblio-1273552

ABSTRACT

Background: Radiation dose depends on the total workload (Wtot) which is affected by the number of patients, tube potential, and tube current. Despite the increment in patients visiting the X-ray units under study and X-ray tube revolutions, changes have not been made in the shielding material to suit the current situation. Aims: This study aims to evaluate the thickness of X-ray shielding barriers in two tertiary hospitals in Kano Metropolis using XRAYBAR software. Materials and Methods: This was a prospective, cross-sectional study and was undertaken from March 2017 to October 2017. A purposive sampling technique was employed to select two hospitals out of five. The two were named A and B, respectively. The minimum required thickness in each barrier was determined by XRAYBAR software. Results: The Wtot (workload) for room I, II and III was found to be 199.9, 146, and 149.1 mA-min per week. The shielding barrier thickness required to reduce the unshielded radiation dose to the design dose limit for wall 1, 2, 3, 4, and operating console of the Room I was found to be 17.5, 5.5, 0.2, 0.00, 3.3 cm, that of wall 1, 2, 3, and 4 of room II was found to be 9.1, 3.4, 0.02, 2.3 cm, while for the wall 1, 2, 3, 4, and operating console of room III was found to be 12.3, 4.8, 3.8, 3.2, and 26.5 cm, respectively. Conclusion: The calculated shielding barrier thickness from XRAYBARR code when compared to the design barrier thickness was found to be adequate


Subject(s)
Nigeria , Radiation Dosage , Radiation Protection/instrumentation , Tungsten , X-Rays