1.
Cardiovasc. j. Afr. (Online) ; 28(2): 134-136, 2017.
Article in English | AIM | ID: biblio-1260468

ABSTRACT

In the daily practice of pacemaker insertion, the occurrence of atrial and ventricular lead switch at the pacemaker box header is a rare and unintentional phenomenon, with less than five cases reported in the literature. The lead switch may have dire consequences, depending on the indication for the pacemaker. One of these consequences is pacemaker syndrome, in which the normal sequence of atrial and ventricular activation is impaired, leading to sub-optimal ventricular filling and cardiac output. It is important for the attending physician to recognise any worsening of symptoms in a patient who has recently had a permanent pacemaker inserted. In the case of a dual-chamber pacemaker, switching of the atrial and ventricular leads at the pacemaker box header should be strongly suspected. We present an unusual case of pacemaker syndrome and right ventricular-only pacinginduced left ventricular systolic dysfunction in a patient with a dual-chamber pacemaker


Subject(s)
Heart Failure, Systolic , Pacemaker, Artificial , South Africa , Ventricular Dysfunction, Left
3.
Niger. j. med. (Online) ; 17(1): 7-12, 2008.
Article in English | AIM | ID: biblio-1267222

ABSTRACT

Background: Symptomatic heart block is a treatable cardiac cause of death which occurs globally. In Nigeria it is increasingly diagnosed and treated with permanent artificial cardiac pacemaker insertion and pulse generator implantation; sometimes after a period of misdiagnosis and inappropriate treatment. Methods: Twenty-three patients who were diagnosed with symptomatic heart block and surgically treated with permanent artificial cardiac pacemaker in National Cardiothoracic Centre; Enugu; between April 2001 and March 2006 had their case notes retrospectively reviewed and information entered into a proforma. This was analyzed. Patients diagnosed with symptomatic heart block but not treated with artificial cardiac pacemaker insertion were excluded from the study. There were eight such patients who could not afford the cost of surgical treatment during the period under review. Results: The mean age of the patients was 70 years and the commonest presentation was shortness of breath (100). Hypertensive heart disease was present in 65of the patients and a history of chronic chloroquine usage was positive in 73of the patients. Predominant pre-treatment pulse rate was in the range of 30-40 per minute (43) while 21of the patients had pulse rate below 30 per minute. These categories of patients commonly had Stoke-Adams syndrome. Sixty-seven per cent of the patients had predominantly systolic hypertension on admission and 16had hypotension. Third degree heart block was present in 65of the patients and 89of all patients needed pre-pacing haemodynamic stabilization with positive inotropic / chronotropic drug(s). Treatment consisted of permanent endocardial pacing in 65and epicardial pacing in 35of the patients with equally good response in symptoms; haemodynamic parameters and electrocardiographic features. Conclusion: Permanent artificial cardiac pacing is the reliable treatment of symptomatic heart block and should be included in the National Health Insurance Scheme list


Subject(s)
Heart Block/therapy , Pacemaker, Artificial , Review
4.
Cardiol. trop ; 31(123): 31-34, 2005.
Article in French | AIM | ID: biblio-1260340

ABSTRACT

The permanent cardiac pacing is not developed in sub-Saharan Africa for technical and economics reasons. The aims of this study were to check the indications of pacing; the techniques and the follow-up for 62 patients. The sex ratio was 0.93 and the average age of patients was 64 -+ 14.7 years. Fifty-two (52) patients had a low socio-economic level (83.9


Subject(s)
Heart , Heart Conduction System , Pacemaker, Artificial