1.
Rev. bras. cir. cardiovasc ; 36(4): 500-505, July-Aug. 2021. tab
Article in English | LILACS | ID: biblio-1347154

ABSTRACT

Abstract Introduction: Use of bilateral internal thoracic artery (BITA) as graft in coronary artery bypass grafting (CABG) is controversial because it is related to higher in-hospital mortality, incidence of sternal wound-related infection, and an increase in surgical time. The primary objective of this study is to evaluate in-hospital mortality and mortality within 30 days from discharge. The secondary objective is to evaluate the occurrence of deep sternal wound infection in a 90-day follow-up. Methods: This is a retrospective review of the medical records of 152 patients undergoing elective CABG with the use of BITA and cardiopulmonary bypass (CPB). These patients were divided into two groups, diabetics and non-diabetics. Patients with acute myocardial infarction and concomitant valvular disease were not included in the sample. Results: Preoperative characteristics did not show significant differences between the groups, which allowed a comparative analysis. The variables electrocardiography time and aortic clamping time were higher in the diabetic group, with a significant statistical difference (P<0.0001). In-hospital mortality occurred in three patients, and there was no mortality up to 30 days in both groups. There was no significant difference in the primary end point between groups (P=0.56). Deep sternal wound infection was present in only one patient and showed no significant difference in the secondary outcome between groups (P=0.40). Conclusion: We did not observe a higher mortality and occurrence of deep sternal wound infection with the use of BITA in diabetic patients compared to non-diabetics, even with greater CPB and aortic clamping times in diabetics.


Subject(s)
Coronary Artery Disease/surgery , Diabetes Mellitus , Mammary Arteries , Surgical Wound Infection/etiology , Retrospective Studies , Risk Factors , Treatment Outcome , Myocardial Revascularization
2.
Rev. bras. cir. cardiovasc ; 29(4): 650-653, Oct-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-741737

ABSTRACT

Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. Objective: The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Methods: Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. Results: There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Conclusion: Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients. .


Introdução: implante de prótese aórtica transcateter no tratamento da estenose aórtica sintomática de alto risco vem aumentando de número a cada ano no mundo. A curva de aprendizado para implante da prótese aórtica transcateter melhorou os resultados ao longo dos últimos 12 anos, o que permitiu o surgimento de outras vias de acesso como alternativas. Objetivo: Este trabalho refere-se ao implante de prótese aórtica transcateter pela via transaórtica associada à revascularização do miocárdio sem em paciente do sexo masculino de 67 anos com doença pulmonar obstrutiva crônica, hipertensão arterial sistêmica e transplante de rim. Métodos: A revascularização miocárdica e o implante da prótese aórtica transcateter foram realizados com sucesso sem o auxílio da circulação extracorpórea. Resultados: No intra e pós-operatório não houve complicações, a redução do gradiente transvalvar, o aumento do orifício efetivo e ausência de regurgitação paravalvar foram observados pelo ecocardiograma transesofágico. Conclusão: O implante da prótese aórtica transcateter pela aorta ascendente associado com revascularização do miocárdio sem circulação extracorpórea é uma nova alternativa para pacientes de alto rico. .


Subject(s)
Aged , Humans , Male , Aorta , Aortic Valve Stenosis/surgery , Coronary Artery Bypass/methods , Transcatheter Aortic Valve Replacement/methods , Aorta , Aortic Valve Stenosis , Echocardiography, Transesophageal , Reproducibility of Results , Treatment Outcome
3.
Rev. bras. cir. cardiovasc ; 26(4): 667-669, out.-dez. 2011. ilus
Article in Portuguese | LILACS | ID: lil-614763

ABSTRACT

A morfologia do aneurisma coronariano configura um fator predisponente para formação de trombos. Porém, a estase sanguínea causada pela alteração do fluxo pode não ser o suficiente para causar fenômenos tromboembólicos.


The morphology of coronary aneurysm sets a predisposing factor to thrombus formation. However, the blood stasis caused by the change in flow may not be enough to cause thromboembolic events.


Subject(s)
Female , Humans , Young Adult , Coronary Aneurysm/complications , Coronary Artery Bypass/methods , Coronary Thrombosis/complications , Myocardial Infarction/surgery , Coronary Aneurysm , Coronary Thrombosis , Myocardial Infarction/etiology
4.
Rev. bras. cir. cardiovasc ; 20(3): 286-290, jul.-set. 2005. graf
Article in Portuguese | LILACS | ID: lil-421607

ABSTRACT

OBJETIVO: Analisar evolucão e a influência prognóstica dos níveis séricos da troponina I cardíaca nos pacientes com insuficiência cardíaca congestiva (ICC) submetidos a ressincronizacão interventricular (RV), com seguimento de até 59 meses. MÉTODOS: Foram analisados 33 pacientes com miocardiopatia dilatada idiopática em classe funcional III/IV da NYHA, submetidos a RV. A qualidade de vida (QV) foi analisada pré e pós-operatoriamente com o Minnesota Code e a funcão ventricular através da ecocardiografia. Os níveis séricos da troponina I foram dosados em 23 pacientes, utilizando o teste exato de Fischer para avaliar sua relacão com o evento óbito, e a curva de Kaplan-Meier para análise da taxa de sobrevivência. RESULTADOS: A QV foi significantemente melhor após a RV, com mediana de 73 pontos, no pré e 36, no pós (p<0,0001). O diâmetro diastólico do VE (DDVE) apresentou reducão de 65mm, no pré para 60mm, no pós (p=0,0014), com aumento da fracão de ejecão (FEVE) de 37 para 47 por cento (p=0,0004). Nos 15 pacientes com valores normais de troponina, não ocorreram óbitos e dos oito pacientes com valores elevados, seis faleceram (p=0,0003). A curva atuarial de livres de óbitos mostrou uma taxa de sobrevivência de 47,1n13,3 por cento, ao final de 59 meses. CONCLUSÕES: A RV em pacientes com ICC melhora a QV e os parâmetros ecocardiográficos. Constitui uma boa alternativa para os pacientes em classe funcional III/IV NYHA. Os níveis séricos elevados da troponina I cardíaca foram preditores de risco para óbito.


Subject(s)
Adult , Aged , Male , Humans , Heart Failure , Quality of Life , Follow-Up Studies , Pacemaker, Artificial
5.
Rev. bras. cir. cardiovasc ; 19(4): 348-352, nov.-dez. 2004. tab
Article in Portuguese | LILACS | ID: lil-393584

ABSTRACT

OBJETIVO: Avaliar a importância dos níveis séricos de troponina I-cardíaca no pré-operatório de pacientes portadores de obstrução no tronco da artéria coronária esquerda (OTCE) sem evento cardíaco prévio. MÉTODO: Foram analisados os níveis séricos da troponina I-cardíaca de 115 pacientes com doença coronariana obstrutiva, com idade variando entre 32 e 81 anos (média e desvio-padrão de 59,7±10,5 anos). Os pacientes foram divididos em dois grupos: Grupo A - 41 pacientes portadores de OTCE, variando o grau de obstrução entre 20 por cento de perda do diâmetro e subtotal (moda de 60 por cento); Grupo B - 74 pacientes sem OTCE. Todos os pacientes foram submetidos a cineangiocoronariografia de forma eletiva e não apresentavam infarto agudo do miocárdio prévio. O método empregado na dosagem da troponina-I cardíaca foi o da Quimioluminiscência, admitindo-se como valor normal abaixo de 0,1 nanogramas por mililitro (ng/ml). RESULTADOS: Não houve correlação entre o grau de OTCE e os níveis séricos de troponina-Ic (P= 0,4617), porém a média dos níveis séricos da troponina-I nos grupos A e B foi, respectivamente, 0,3841 ng/ml e 0,1711 ng/ml (P=0,0324); teste de Mann-Whithey; OR= 4,44 (IC95 por cento 1,60 _ 12,31). CONCLUSÕES: Os pacientes do grupo A têm 3,44 vezes mais chance de apresentar lesão miocárdica representada por elevação de troponina I-cardíaca que o grupo B, independente do grau da OTCE. A sensibilidade para suspeita clínica de mionecrose foi relativamente baixa (31,7 por cento), porém a especificidade foi elevada (90,5 por cento). Destaca-se, entretanto, a importância clínica da documentação de mionecrose em uma determinada porcentagem de pacientes com lesão de tronco, sem constatação eletrocardiográfica. Assim, os pacientes com OTCE devem ser submetidos com rapidez a procedimento operatório, a fim de evitar extensão da mionecrose.


Subject(s)
Humans , Male , Female , Middle Aged , Coronary Disease/physiopathology , Myocardial Ischemia/physiopathology , Biomarkers , Troponin/biosynthesis , Myocardial Infarction/physiopathology