Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
J. appl. oral sci ; 16(1): 30-34, Jan.-Feb. 2008. tab
Article in English | LILACS | ID: lil-472686

ABSTRACT

The aim of this study was to compare the shrinkage stress of composite resins by three methods. In the first method, composites were inserted between two stainless steel plates. One of the plates was connected to a 20 kgf load cell of a universal testing machine (EMIC-DL-500). In the second method, disk-shaped cavities were prepared in 2-mm-thick Teflon molds and filled with the different composites. Gaps between the composites and molds formed after polymerization were evaluated microscopically. In the third method, the wall-to-wall shrinkage stress of the resins that were placed in bovine dentin cavities was evaluated. The gaps were measured microscopically. Data were analyzed by one-way ANOVA and Tukey's test (alpha=0.05). The obtained contraction forces were: Grandio = 12.18 ± 0.428N; Filtek Z 250 = 11.80 ± 0.760N; Filtek Supreme = 11.80 ± 0.707 N; and Admira = 11.89 ± 0.647 N. The gaps obtained between composites and Teflon molds were: Filtek Z 250 = 0.51 ± 0.0357 percent; Filtek Supreme = 0.36 ± 0.0438 percent; Admira = 0.25 ± 0.0346 percent and Grandio = 0.16 ± 0.008 percent. The gaps obtained in wall-to-wall contraction were: Filtek Z 250 = 11.33 ± 2.160 µm; Filtek Supreme = 10.66 ± 1.211µm; Admira = 11.16 ± 2.041 µm and Grandio = 10.50 ± 1.224 µm. There were no significant differences among the composite resins obtained with the first (shrinkage stress generated during polymerization) and third method (wall-to-wall shrinkage). The composite resins obtained with the second method (Teflon method) differed significantly regarding gap formation.


Subject(s)
Animals , Cattle , Composite Resins/chemistry , Dental Materials/chemistry , Chemical Phenomena , Dental Cavity Preparation , Dental Marginal Adaptation , Dentin/ultrastructure , Materials Testing , Methacrylates/chemistry , Pressure , Polymers/chemistry , Polytetrafluoroethylene/chemistry , Stress, Mechanical , Surface Properties , Siloxanes/chemistry
2.
J. appl. oral sci ; 15(5): 406-411, Sept.-Oct. 2007. graf, tab
Article in English | LILACS | ID: lil-465921

ABSTRACT

The fluoride release of restorative materials in deionized water has been the subject of many studies, but the behavior of these materials under conditions of acid challenge that simulates the oral cavity, needs to be further explored. Therefore, the aim of this study was to evaluate the fluoride release of restorative materials in two storage protocols: deionized water and pH-cycling system (demineralizing solution-pH 4.3 and remineralizing solution-pH 7.0) for 15 days. Eight disks of each material (Vitremer™-positive control, Dyract AP, Ariston pHc, Definite®, Tetric®Ceram and Z100-negative control) were prepared (11.0 mm x 1.5 mm) and suspended individually in 4.0 mL of each solution, which were daily changed. Daily fluoride release was analyzed with an ion specific electrode (Orion 9609) by the direct method or after HMDS-facilitated diffusion, following 1, 7 and 15 days. The values obtained were converted into µgF/mm² and the data analyzed by ANOVA and Tukey's test (p< 0.05). The results showed that all materials released more fluoride in the pH-cycling system, except for Ariston pHc which maintained a constant release during the experiment. The highest fluoride release was presented by the positive control, Vitremer™ in pH-cycling and by Ariston pHc, in deionized water. The negative control Z100 and the resins Definite® and Tetric®Ceram did not present statistically significant differences.

3.
RPG rev. pos-grad ; 12(1): 21-25, jan.-mar. 2005. tab
Article in Portuguese | LILACS, BBO | ID: lil-455267

ABSTRACT

Avaliou-se a adaptação de resinas compostas às paredes axial e cervical de preparos do tipo classe II (MOD) em função da configuração cavitária (ângulos vivos ou arredondados), empregando-se três sistemas restauradores adesivos (Fill Magic/Unibond, Z250/Single Bond e P60/Single Bond). A partir dos dados obtidos aplicou-se a análise estatística utilizando o "Wilcoxon Matched Pairs Test", com nível de significância p<0.05. Concluiu-se que não houve diferença estatisticamente significante entre a conformação cavitária de ângulos vivos e arredondados em relação à extensão das fendas nas paredes axial e cervical, a configuração cavitária de ângulos arredondados apresentou valores estatisticamente inferiores aos obtidos pela configuração em ângulos vivos para os sistemas Fill Magic/Unibond e Z250/Single Bond


Subject(s)
Humans , Composite Resins , In Vitro Techniques , Dental Cavity Preparation/methods , Dental Leakage/prevention & control , Molar, Third
4.
RGO (Porto Alegre) ; 53(1): 23-26, jan.-mar. 2005. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-412561

ABSTRACT

Avaliou-se a atividade inibitória de diferentes materiais restauradores e selantes de fóssulas e fissuras sobre microrganismos cariogênicos através do método de difusão em ágar, empregado-se o ágar Mueller-Hinton acrescido de 5 por cento de sangue desfribrinado de carneiro. Verificou-se que a maioria dos materiais testados apresentou alguma atividade inibitória frente aos microrganismos isolados, particularmente os cimentos ionoméricos. As resinas compostas, à exceção do Dyract, não evidenciaram atividade antimicrobiana


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Glass Ionomer Cements/pharmacology , Dental Caries , Dental Materials , Composite Resins/pharmacology , Pit and Fissure Sealants/pharmacology , Anti-Bacterial Agents
5.
Braz. oral res ; 18(2): 156-161, Apr.-Jun. 2004. tab
Article in English | LILACS | ID: lil-363267

ABSTRACT

O objetivo deste estudo foi mensurar a perda de massa e as alterações de rugosidade superficial de diferentes marcas de resinas compostas "flow" após teste de escovação simulada. A hipótese nula testada foi de que não haveria diferença de massa e rugosidade de superfície após o teste e de que não haveria correlação entre essas variáveis. Os materiais testados foram: Aeliteflo (Bisco), Flow-It (Pentron), Flow-It LF (Pentron), Natural Flow (DFL) e Wave (SDI). As resinas compostas Z100 (3M/ESPE) e Silux Plus (3M/ESPE) foram utilizadas como controle. Doze espécimes (5 mm de diâmetro, 3 mm de espessura) de cada material foram confeccionados de acordo com as instruções do fabricante. O teste foi conduzido em uma máquina de escovação simulada, em todos os espécimes de todos os materiais, totalizando 100.000 ciclos. Antes e depois do teste, a massa e a rugosidade de cada material foram aferidas por uma balança analítica Sartorius de 0,0001 g de precisão e pelo equipamento Hommel Tester T1000, respectivamente. Os valores obtidos foram comparados pelos testes t-pareado e Tukey (p < 0,05). Todos os materiais apresentaram diferenças estatísticas de perda de massa entre os valores iniciais e finais, com exceção da resina Flow-It LF. Entretanto, nenhuma diferença foi observada quando se comparou a porcentagem de perda de massa entre os diferentes materiais testados. Todos os materiais tornaram-se mais rugosos, sendo Wave, estatisticamente, o mais rugoso. As resinas compostas "flow" não demonstraram superioridade em relação aos materiais de controle, devendo-se esperar o desgaste por perda de massa do material e maior rugosidade após a ação da escovação. A hipótese nula antecipada foi parcialmente aceita.


Subject(s)
Composite Resins/chemistry , Toothbrushing , Tooth Abrasion/etiology , Dental Restoration Wear , Materials Testing , Surface Properties , Toothbrushing/adverse effects
6.
Pesqui. odontol. bras ; 16(4): 343-348, out.-dez. 2002. tab
Article in English | LILACS, BBO | ID: lil-327308

ABSTRACT

O presente estudo foi conduzido "in vitro" com o intuito de constatar as propriedades (desgaste e rugosidade) dos CIV, as quais influenciam na sua indicaçäo como material selador de fossas e fissuras. Os materiais empregados foram Fuji Plus, Ketac Molar e Vitremer (duas proporçöes: 1:1 e 1/4:1). O selante Delton foi controle. A determinaçäo do desgaste foi obtida através da quantidade de massa perdida após a escovaçäo e a rugosidade através da análise quantitativa da superfície. Os resultados mostraram que o Vitremer diluído e o Fuji Plus apresentaram maior grau de desgaste e maior aumento de rugosidade. Apesar de clinicamente se encontrar um maior uso dos CIV cimentantes ou diluídos como forma alternativa para material selador; este trabalho permitiu concluir que estes possuem propriedades bastante inferiores quando comparados aos ionômeros restauradores que, por sua vez, possuem resultados semelhantes ao selante resinoso


Subject(s)
Dental Materials , Dental Restoration Wear , In Vitro Techniques , Pit and Fissure Sealants
7.
Rev. Fac. Odontol. Bauru ; 10(1): 7-16, jan.-mar. 2002. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-321826

ABSTRACT

Este estudo comparou a utilizaçäo de uma técnica de fotoativaçäo contínua com uma seqüencial em duas etapas, começando com baixa intensidade de luz seguida de uma intensidade maior e utilizando duas resinas compostas. A interferência dos métodos de ativaçäo foi analisada näo só quanto à formaçäo de fendas marginais (f.m.) mas, também, quanto ao grau de polimerizaçäo, com a avaliaçäo da dureza Vickers. Paralelamente, foi verificada a viabilidade de um método simplificado de moldes de polivinilsiloxana para a medida das de fendas. Foram mensuradas as f.m. formadas na interface de restaurações com a dentina, usando as resinas compostas Z100 e Solitaire, em cavidades cilíndricas de molares humanosrecém-extraídos, através da microscopia óptica, feita diretamente nesses espécimes e, indiretamente nosmoldes. Concluiu-se que as f.m. foram menores e a dureza no topo foi maior, quando se utilizou a ativaçäo seqüencial, com a intensidade inicial de 180 mW/cm2 por 20 segundos, seguida de 650 mW/cm2 por 40 segundos; a resina Z100 teve melhor desempenho com relaçäo às fendas e à dureza Vickers tanto no topo quanto na base; na espessura de 2 mm, ambas as resinas mostraram valores médios de dureza menores na superfície de base que na de topo; finalmente, a técnica indireta, com a utilizaçäo dos moldes, para as medidas, foi considerada viável, uma vez que os resultados obtidos com ela foram coincidentes com os da técnica direta


Subject(s)
Humans , Composite Resins , Dental Marginal Adaptation , Hardness , Dental Materials/classification , Dental Materials/chemistry , Microscopy
8.
Rev. Fac. Odontol. Bauru ; 7(1/2): 15-21, jan.-jun. 1999. ilus
Article in Portuguese | LILACS, BBO | ID: lil-271841

ABSTRACT

A resistência de uniäo de cinco cimentos disponíveis no mercado e utilizados na fixaçäo de bráquetes ortodônticos (Concise Ortodôntico, Fuji Ortho LC, Vitremer, Dyract e Transbond XT) foi estudada. Foram utilizados 50 dentes pré-molares superiores humanos, hígidos, recém extraídos, conservados em soluçäo de Cloramina T a 1 por cento e água até o momento de sua utilizaçäo. Os dentes tiveram suas raízes seccionadas em nível da junçäo cemento-esmalte, sendo posteriormente incluídos em resina epóxica, com auxílio de matrizes de silicona, e depois armazenados em água deionizada até o momento da fixaçäo dos bráquetes. Previamente à fixaçäo foi realizada profilaxia com pasta de pedra pomes e água, utilizando-se taça de borracha em motor de baixa rotaçäo. Os materiais foram utilizados de acordo com as instruçöes dos respectivos fabricantes. Após fixaçäo dos bráquetes, os corpos de prova foram armazenados em água deionizada à 37ºC durante 24 horas. Os testes de cisalhamento foram realizados com auxílio de uma Máquina de Ensaios Universal Kratos, com velocidade de 0,5mm/minuto. Os resultados foram analisados estatisticamente, o que permitiu concluir que: a) todos os cimentos atingiram valores aceitáveis à prática ortodôntica; b) com exceçäo dos grupos Concise Ortodôntico x Transbond XT e Fuji Ortho LC x Transbond XT, houve diferença estatística significante entre todos os outros grupos, c) as falhas adesivas ocorreram, na maioria das vezes (66 por cento), na interface cimento/bráquete


Subject(s)
Humans , Dental Cements/analysis , Orthodontic Brackets , Bicuspid , Glass Ionomer Cements/analysis , Glass Ionomer Cements/classification , Dental Cements/classification , Dental Bonding/classification , Dental Bonding/methods , Composite Resins/analysis , Composite Resins/classification
9.
Rev. Fac. Odontol. Bauru ; 6(4): 35-40, out.-dez. 1998. tab
Article in Portuguese | LILACS, BBO | ID: lil-271737

ABSTRACT

A influência de adesivos e da umidade dentinária na resistência ao cisalhamento da uniäo entre dentina e materiais restauradores diretos, foi avaliada neste trabalho. Os materiais restauradores testados foram: cimento de ionômero de vidro (C.I.V.) convencional, C.I.V. modificado com resina, resina composta modificada com poliácidos e resina composta. No trabalho foram utilizados 240 pré-molares e molares humanos extraídos, que tiveram uma de suas superfícies proximais desgastadas, sobre a qual foram aplicados os sistemas adesivos e os materiais restauradores. Os espécimes foram divididos em 4 grupos experimentais, de acordo com o material usado para o tratamento da dentina, como segue: I) adesivo próprio indicado pelo fabricante; II) sistema adesivo experimental Gluma C; III) sistema adesivo Prime & Bond 2.0; e IV) sistema adesivo Scotchbond MP. As técnicas de secagem da dentina foram jato de ar por 5 segundos, considerada "técnica seca", e lenço de papel aplicado duas vezes sobre a dentina, considerada "técnica úmida". Os espécimes foram testados em máquina universal de testes. Os adesivos (grupos II e III) melhoraram significantemente a adesäo quando comparados com o adesivo próprio. A técnica de secagem da dentida considerada úmida promoveu resultados significantemente melhores que a considerada seca (p<0,01)


Subject(s)
Humans , Dentin-Bonding Agents/chemistry , Dental Cements/chemistry , Dentin-Bonding Agents/classification , Glass Ionomer Cements/classification , Glass Ionomer Cements/chemistry , Dental Cements/classification , Dental Cements/chemistry , Composite Resins/chemistry , Composite Resins/classification , Dentin , Dental Materials/classification , Dental Materials/chemistry
10.
Rev. Fac. Odontol. Bauru ; 6(2): 23-8, abr.-jun. 1998. tab
Article in Portuguese | LILACS, BBO | ID: lil-256195

ABSTRACT

A influência de adesivos e da umidade dentinária na resistência ao cisalhamento da uniäo entre dentina e materiais restauradores diretos foi avaliada neste trabalho. Os materiais restauradores testados foram: um cimento de ionômero de vidro convencional (Chelon-fil - ESPE), um cimento de ionômero de vidro modificado com resina (Vitremer - 3M), uma resina composta modificada com poliácidos (Dyract - Dentsply) e uma resina composta (TPH Dentsply). No trabalho foram utilizados 240 pré-molares e molares humanos extraídos, que tiveram uma de suas superfícies proximais desgastadas até se obter uma superfície plana em dentina, sobre a qual foram aplicados os sistemas adesivos e os materiais restauradores. Os espécimes foram divididos em 4 grupos experimentais. No grupo 4.3.1, a dentina foi condiconada com o adesivo próprio indicado pelo fabricante do material restaurador; no grupo 4.3.2., a dentina foi condicionada com um sistema adesivo experimental Gluma C; no grupo 4.3.3, a dentina foi condicionada com o sistema adesivo Prime & Bond 2.0 (Dentsply); e no grupo 4.3.4, a dentina foi condicionada com o sistema adesivo Scotchbond MP (3M). A técnica de secagem da dentina utilizada foi jato de ar por 5 segundos, considerada técnica seca, e lenço de papel aplicado duas vezes sobre a dentina, considerada técnica úmida. Os espécimes foram confeccionados com os materiais restauradores e os sistemas adesivos utilizados de acordo com as instruçöes dos fabricantes, armazenados em água por 24 horas e testados em máquina universal de testes KRATOS. A análise estatística mostrou que a resina composta Dyract, a melhor combinaçäo foi a do adesivo próprio na técnica úmida, que apresentou o maior resultado, de 23,36MPa. Os resultados com cimento Vitremer, utilizando-se os sistemas adesivos Prime & Bond 2.0 e o adesivo experimental Gluma C, foram de 16,45MPa e 13,58 MPa, respectivamente. Esses adesivos melhoraram significantemente a adesäo quando comparados com o adesivo próprio. Com relaçäo à técnica de secagem da dentina, a técnica úmida foi significantemente melhor que a técnica seca (p<0,01)


Subject(s)
Humans , Dentin-Bonding Agents/analysis , Glass Ionomer Cements/chemistry , Glass Ionomer Cements/classification , Dental Cements/chemistry , Composite Resins/chemistry , Composite Resins/classification , Dentin/chemistry , Injections, Jet/methods , Dental Materials/analysis , Dental Materials/chemistry
11.
Rev. Fac. Odontol. Bauru ; 5(1/2): 59-63, jan.-jun. 1997. tab
Article in English | LILACS, BBO | ID: lil-222580

ABSTRACT

The aim of this study was to investigate the bond to dentin of a resin composite promoted by the Gluma bonding system applied to dry or wet dentin surfaces. The bonding system was modified as regards the conditioner and the composition of the primer. Various acidic conditioners were used, and the primer was modified by addition of water and acetone. Bond strengths between 12 and 22 MPa were recorded. It was concluded that bonds of good strength can be obtained with 20% phosphoric acid as pretreatment. It was further concluded that "moist" dentin does not interfere with bonding, but that "wet" dentin may reduce the bond strength about 25%


Subject(s)
Dentin-Bonding Agents/analysis , Composite Resins/analysis , Dental Restoration, Permanent , Dental Materials/analysis
12.
Rev. Fac. Odontol. Bauru ; 3(1/4): 103-7, jan.-dez. 1995. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-222542

ABSTRACT

Verificou-se a influência do reaquecimento dos moldes de mercaptans e siliconas de adiçäo nos modelos de gesso para prótese fixa. Foi desenvolvido para esta pesquisa um dispositivo composto de dois cones truncados separados por uma distância semelhante à de um pôntico simulando uma prótese fixa de três elementos. Os materiais utilizados foram o Provil L, o Baysilex e o Permlastic Regular que foram polimerizados a 37ºC e vazados a 50 por cento após atingirem a temperatura ambiente 22+- 2ºC e os outros 50 por cento após reaquecimento à temperatura da boca 37ºC ambos em gesso tipo IV. O Permlastic e o Baysilex apresentaram, sob condiçäo de reaquecimento, uma melhora de reusltado absoluto em relaçäo ao vazamento da maneira convencional. O material que comportou-se melhor foi a silicona de adiçäo Bayselex


Subject(s)
Silicone Elastomers/analysis , Rewarming , Dental Impression Technique , Dental Impression Materials/analysis , Dental Prosthesis/methods
13.
Rev. Fac. Odontol. Bauru ; 3(1/4): 157-62, jan.-dez. 1995. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-222549

ABSTRACT

Avaliou-se a adaptaçäo marginal da resina composta P-50 em cavidades localizadas em dentina, quanto à eficiência dos agentes de uniäo à dentina na prevençäo das fendas marginais. Os adesivos com melhor comportamento foram o GLUMA, a resina Gluma e o Tenure. Concluiu-se também que a adaptaçäo das restauraçöes melhora quando o acabamento e polimento das mesmas é adiado por 7 dias ou mais


Subject(s)
Humans , Dentin-Bonding Agents/analysis , Composite Resins/analysis , Dental Marginal Adaptation , Dental Cements/analysis , Dental Leakage/prevention & control , Dental Materials/analysis
14.
Rev. Assoc. Paul. Cir. Dent ; 49(3): 236-40, maio-jun. 1995. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-159892

ABSTRACT

Este trabalho estudou a influência da imersäo em soluçöes de água destilada com dentifrícios fluoretados e näo fluoretados e da imersäo em soluçäo de fluoretos para bochecho e em géis de flúor neutro e ácido, utilizados para aplicaçäo tópica, sobre a alteraçäo da superfície pigmentada e glazeada de pastilhas cerâmicas. Com a mesma finalidade, também foram efetuados testes de abrasäo em máquina de escovaçäo. As análises foram efetuadas através de avaliaçöes de textura de superfície, avaliaçäo visual e microscopia óptica


Subject(s)
Ceramics/therapeutic use , Gels/therapeutic use , Dental Restoration, Permanent/methods , Mouthwashes/therapeutic use , Crowns , Dentifrices/therapeutic use
15.
Rev. Fac. Odontol. Bauru ; 2(2): 8-13, abr. 1994. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-222484

ABSTRACT

Avaliaçäo da adaptaçäo marginal de resinas compostas em cavidades preparadas em dentina, quanto à eficácia de alguns agentes de uniäo à dentina, na prevençäo das fendas marginais, assim como a influência do adiamento do período determinados da realizaçäo do acabamento e polimento das restauraçöes, no posterior fechamento dessas fendas. Foram utilizados dentes molares humanos extraídos, que tiveram uma de suas superfícies proximais desgastadas até se obter a remoçäo da camada de esmalte e exposiçäo da dentina, tornando esta superfície plana. Foram preparadas 180 cavidades em dentina com junçäo topo a topo. Cada cavidade recebeu um dos seguintes tratamentos: 1) Tergentol + ARM (controle); 2) Adesivo Multi-purpose; 3) Adesivo All-Bond 2; 4) Adesivo Optibond; 5) Adesivo Prisma Universal Bond 3. Esses adesivos foram empregados de acordo com as instruçöes dos respectivos fabricantes. Em seguida, a metade dessas cavidades foi restaurada com resina composta Z-100. Terminada a restauraçäo, os dentes eram imediatamente armazenados em água destilada a 37 graus C, por períodos de 10 minutos, 7 dias e 21 dias. Após cada um desses períodos, foi feito o acabamento e as fendas marginais ocorridas pela contraçäo de polimerizaçäo foram entäo medidas através de um fotomicroscópio ótico, com uma ocular de mensuraçäo, sendo entäo calculada a contraçäo de ...


Subject(s)
Humans , Dentin-Bonding Agents/analysis , Composite Resins , Dental Cavity Preparation , Dental Materials , Dental Restoration, Permanent , Dental Polishing
16.
RGO (Porto Alegre) ; 39(2): 98-100, mar.-abr. 1991. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-854737

ABSTRACT

O propósito da presente pesquisa foi verificar o comportamento dos elastômeros, através de materiais representativos, mais comumente usados na clínica, comparando-se o método convencional de obtenção do molde. Com o método de reaquecimento do molde estudado por ARAUJO & JORGENSEN (2). Através da análise dos resultados, pode-se afirmar que os troquéis obtidos de moldes reaquecidos à 37ºC, apresentam uma maior precisão do que aqueles de moldagens convencionais. Os materiais de moldagem que se comportam melhor, quanto a estabilidade dimensional foram o Impregum e o Provil


Subject(s)
Dental Impression Materials , Rubber
17.
Rev. odontol. Univ. Säo Paulo ; 4(3): 212-5, jul.-set. 1990. ilus, tab
Article in English | LILACS, BBO | ID: biblio-858613

ABSTRACT

Moldagens de um modelo confeccionado em aço inoxidável com o formato de um dente preparado para coroa total foram feitas, a 37ºC, utilizando-se uma silicona de adição (Presidente R.). Dois tamanhos de moldeira foram utilizados, uma para obter uma camada de material de moldagem de 1 mm de espessura, na região gengival do preparo e outra para obter uma camada de 4 mm. O modelo padrão de aço, podia apresentar retenções para apical da margem gengival, conforme descrito anteriormente, permitindo variar a profundidade de retenção em 0,5 ou 1,5 mm. Troquéis de gesso eram obtidos: 1) após resfriar os moldes a 22ºC por 10 minutos e 2) após resfriar os moldes a 22ºC por 10 minutos e posteriormente reaquecê-los a 37ºC, por 30 minutos. Os resultados mostraram que reaquecer os moldes à temperatura da boca melhora a precisão dos moldes e que as retenções têm uma influência definida mas pequena sobre a precisão dos moldes de silicona de adição


Subject(s)
Dental Impression Materials , Silicones/analysis , In Vitro Techniques
18.
Rev. bras. odontol ; 47(4): 2-8, jul.-ago. 1990. tab
Article in Portuguese | LILACS, BBO | ID: lil-88078

ABSTRACT

Uma liga experimental de Ni-Cr para metalo-cerâmica foi comparada com duas ligas comerciais (Durabond e Biobond II), através de testes de resistência à traçäo e medida de alongamento, testes de dureza Rockwell, de contraçäo de solidificaçäo e de ajuste cervical de coroas fundidas. A liga experimental mostrou possuir propriedades comparáveis e as vezes superiores às das ligas comerciais, tendo apresentado menor contraçäo de solidificaçäo e ajuste cervical semelhante ao da liga Biobond II


Subject(s)
Chromium Alloys , Dental Alloys , Hardness Tests , Nickel , Tensile Strength
19.
Rev. odontol. Univ. Säo Paulo ; 4(2): 150-2, abr.-jun. 1990. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-858598

ABSTRACT

Moldagens de um modelo confeccionado em aço inoxidável, com o formato de um dente preparado para coroa total foram feitas, a 37ºC, utilizando-se um polisulfeto (Permlastic R). Dois tamanhos de moldeira foram utilizados, um para obter uma camada de material de moldagem com 1 mm de espessura, na região gengival do preparo e outra, para obter uma camada de 4 mm. Troquéis de gesso foram obtidos (1) após resfriamento do molde a 22ºC, por 10 min e (2) após resfriamento do molde a 22ºC por 10 min e posterior reaquecimento, a 37ºC, por 30 min. Os resultados permitiram concluir que o reaquecimento do molde à temperatura da boca, antes do vazamento do gesso, melhora a precisão dos troquéis


Subject(s)
Dental Impression Materials , Dental Materials
20.
RGO (Porto Alegre) ; 33(3): 190-4, jul.-set. 1985. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-872498

ABSTRACT

Os autores estudaram as reações do tecido conjuntivo subcutâneo do rato induzidas por quatro componentes das resinas compostas Bis-GMA, éter metílico de benzoína, silano e silicato de vidro. Injetou-se intravenosamente uma solução aquosa de Evan's blue e inoculou-se intravenosamente 0,1ml dos materiais acima mencionados no dorso dos animais, em um sistema de rodízio. Após intervalo de 3 horas, os animais foram sacrificados, suas peles excisadas e imersas imediatamente em formamida e armazenada em estufa por 72 horas. O líquido foi analisado ao espectrofotômetro e classificado segundo os critérios estabelecidos por NAGEM-FILHO & PEREIRA (8). O potencial irritativo dos componentes das resinas compostas se apresentou na seguinte ordem: Bis-GMA - não significante a discreto ; Silano - severo; Éter metílico de benzoína - não significante a discreto


Subject(s)
Rats , Composite Resins/adverse effects , Composite Resins/pharmacology , Connective Tissue/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL