Results 1 - 12 de 12
Filter
2.
Arq. bras. oftalmol ; 79(4): 264-267, July-Aug. 2016. graf
Article in English | LILACS | ID: lil-794574

ABSTRACT

ABSTRACT We report two cases of suspicious asymmetric bow tie and inferior steepening on topographic evaluations with reflection (Placido) and projection (Scheimpflug). Rotating Scheimpflug corneal and anterior segment tomography (Oculus Pentacam HR, Wetzlar, Germany)® was performed in the first case, with a maximal keratometric value (Kmax) of 43.2 D and an overall deviation value from the Belin/Ambrósio Enhanced Ectasia Display (BAD-D) of 1.76, which was observed in the study eye (OD). BAD-D was 6.59 in the fellow eye, which had clinical findings that were consistent with keratoconus stage 2. The second case presented with a Kmax of 45.3 D and BAD-D of 0.76 in OD and 1.01 in OS. This patient had discontinued wearing soft contact lens less than 1 day prior to examination. Corneal tomographic data enabled us to distinguish mild or forme fruste keratoconus from contact lens-induced corneal warpage, and similar findings were observed on curvature maps.


RESUMO O presente estudo tem por objetivo relatar dois casos suspeitos que apresentam bow tie assimétrico e encurvamento inferior nas avaliações topográficas de reflexão (Placido) e projeção (Scheimpflug). A tomografia de córnea e segmento anterior com o sistema Scheimpflug (Oculus Pentacam HR, Wetzlar, Alemanha)® mostrou no primeiro caso, a ceratometria máxima (Kmax) de 43,2 D e o valor D no Belin/Ambrósio Enhanced Ectasia Display (BAD-D) de 1,76 no olho estudado (OD). O olho contralateral apresentava BAD-D de 6,59 e achados clínicos compatíveis com ceratocone (KC) grau 2. O segundo caso apresentava Kmax de 45,3 D e BAD-D de 0,76 em OD e 1,01 em OS. Este paciente havia interrompido o uso de lentes de contato gelatinosas 1 dia antes do exame. A avaliação tomográfica avançada nos permitiu distinguir ceratocone leve ou subclínico de warpage induzido por lentes de contato, enquanto resultados semelhantes foram observados em mapas de curvatura anterior.


Subject(s)
Humans , Male , Female , Adult , Contact Lenses, Hydrophilic/adverse effects , Corneal Topography/methods , Keratoconus/pathology , Keratoconus/diagnostic imaging , Reference Values , Severity of Illness Index , Diagnosis, Differential , Dilatation, Pathologic/etiology , Keratoconus/etiology
3.
Rev. bras. oftalmol ; 74(6): 382-385, nov.-dez. 2015. tab, graf
Article in English | LILACS | ID: lil-767083

ABSTRACT

RESUMO Objetivo: Avaliar a capacidade de dados de perfil paquimétrico horizontal, a fim de distinguir o ceratocone de córneas normais, e comparar a precisão de índices com outros tomográficos mais complexos. Métodos: Em um estudo retrospectivo, um olho selecionado aleatoriamente de 225 pacientes com ceratocone bilateral e de 335 pacientes com córneas normais foram incluídos. Todos os pacientes foram examinados por um especialista em córnea e foram submetidos ao exame de tomografia de córnea, Pentacam HR (Oculus, Wetzlar, Alemanha). Os dados de perfil paquimétrico horizontal em 6 milímetros passando pelo ápice foi avaliado. Com esses dados, a espessura no ápice corneano (P.ápice), a espessura no ponto mais fino do perfil horizontal (P.min.H), a progressão paquimétrica do ponto mais fino para o mais espesso (PPmin-máx), a progressão paquimétrica média no meridiano temos como referencial a média normal (PPméd) e a adequação a uma linha de tendência polinomial do segundo grau (R2). Um modelo de inteligência artificial foi construído para combinar esses dados. O desempenho para distinguir ceratocone do normal foi avaliada por curvas ROC. Resultados: Todos os índices avaliados foram estatisticamente diferentes entre os dois grupos (p <0,001). A área sob a curva ROC (AUC) de paquimetria no ápice e no TP foram de 0,904 e 0,938, respectivamente. O índice tomográfico com maior AUC foi o BAD-D (0,997). Em relação ao perfil horizontal, a AUC do P.min.H e PPmin-max foram 0,915 e 0,927, respectivamente. A adequação à linha de tendência para o gráfico de espessura no ápice apresentou AUC 0,896. O melhor desempenho foi obtido com o PPméd (AUC 0,932 Sensibilidade = 84,4% e especificidade de 92,5%). O modelo de inteligência artificial combinando todos os itens derivados do perfil horizontal melhorou o desempenho (AUC 0,991 Sens. = 96% e espec. = 98%). Conclusão: O perfil de espessura horizontal permite detectar o ceratocone, com capacidade comparável aos índices mais complexos. Esse tipo de análise pode fornecer o básico para novas abordagens, que utilizem dados presentes em aparelhos mais simples que o tomógrafo, reduzindo o custo para os pacientes.


ABSTRACT Purpose: To evaluate the ability of horizontal thickness profile to distinguish keratoconus from normal corneas, and compare the accuracy of these indices with more complex tomographic indices. Methods: In a retrospective study, one eye randomly selected from 225 patients with bilateral keratoconus and 335 patients with normal corneas were included. All patients were examined by a corneal specialist and underwent the examination of corneal tomography, Pentacam HR (Oculus, Wetzlar, Germany). Data of horizontal pachymetric profile passing through the apex of 6 mm was evaluated. With these data, the thickness at the corneal apex (P.ápice), the thickness of the thinnest point of the horizontal profile (P.min.H), the pachymetric progression from the thinnest point to the thickest (PPmin-max), the average pachymetric progression in the meridian as reference the average from the normal population (PPméd) and the fitness with a second degree polynomial trendline (R2). An artificial intelligence model was built to combine this data. The performance for distinguishing normal keratoconus was evaluated by ROC curves. Results: All of these indices were statistically different between the two groups (p <0.001). The area under the ROC curve (AUC) thickness at the apex and TP were 0.904 and 0.938, respectively. The tomographic index with higher AUC was BAD-D (0.997). Regarding the horizontal profile, the AUC of PP.min.H and PPmin-max were 0.915 and 0.927, respectively. The fitness to the trendline to the horizontal thickness graph AUC was 0.896. The best performance was obtained with the PPméd (AUC 0.932 sensitivity = 84.4% and specificity of 92.5%). The artificial intelligence model combining all items derived from horizontal profile improved performance (AUC 0.991 Sensitivity = 96% and specificity of 98%). Conclusion: The horizontal thickness profile can detect keratoconus, with a capacity comparable to more complex indices. This type of analysis can provide the basics for new approaches, using data present in simpler devices than the tomographer reducing the cost for the patients.


Subject(s)
Humans , Adult , Tomography/methods , Corneal Topography/methods , Corneal Pachymetry/methods , Keratoconus/diagnosis , Tomography/instrumentation , Retrospective Studies , Cornea/anatomy & histology , Cornea/diagnostic imaging , Corneal Topography/instrumentation , Corneal Pachymetry/instrumentation
4.
Rev. bras. oftalmol ; 73(2): 75-80, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-718436

ABSTRACT

Purpose: To compare the ability to detect preoperative ectasia risk among LASIK candidates using classic ERSS (Ectasia Risk Score System) and Pentacam Belin-Ambrósio deviation index (BAD-D), and to test the benefit of a combined approach including BAD-D and clinical data. Methods: A retrospective nonrandomized study involved preoperative LASIK data from 23 post-LASIK ectasia cases and 266 stable-LASIK (follow up > 12 months). Preoperative clinical and Pentacam (Oculus; Wetzlar, Germany) data were obtained from all cases. Mann-Whitney's test was performed to assess differences between groups. Stepwise logistic regression was used for combining parameters.The areas under the Receiver Operating Characteristic (ROC) curves (AUC) were calculated for all parameters and combinations, with pairwise comparisons of AUC (DeLong's method). Results: Statistically significant differences were found for age, residual stromal bed (RSB), central corneal thickness and BAD-D (p<0.001), but not for sphere, cylinder or spherical equivalent (p>0.05). ERSS was 3 or more on 12/23 eyes from the ectasia group (sensitivity = 52.17%) and 48/266 eyes from the stable LASIK group (18% false positive). BAD-D had AUC of 0.931 (95% CI: 0.895 to 0.957), with cut-off of 1.29 (sensitivity = 87%; specificity = 92.1%). Formula combining BAD-D, age and RSB provided 100% sensitivity and 94% specificity, with better AUC (0.989; 95% CI: 0.969 to 0.998) than all individual parameters (p>0.001). Conclusion: BAD-D is more accurate than ERSS. Combining clinical data and BAD-D improved ectasia susceptibility screening. Further validation is necessary. Novel combined functions using other topometric and tomographic parameters should be tested to further enhance accuracy. .


Objetivo: Comparar a capacidade de detectar risco de ectasia no pré-operatório de LASIK usando o clássico ERSS (Ectasia Risk Score System) e índice Belin- Ambrósio (BAD- D) do Pentacam; e para testar o benefício de uma abordagem combinada, incluindo BAD-D e dados clínicos. Métodos: Estudo não randomizado retrospectivo envolveu dados pré-operatórios de LASIK de 23 casos que evoluíram para ectasia pós-LASIK e 266 casos estáveis após LASIK com acompanhamento mínimo de 12 meses. Dados préoperatórios clínicos e do Pentacam (Oculus, Wetzlar, Alemanha) foram obtidos para todos os casos. O teste de Mann-Whitney foi realizado para avaliar as diferenças entre grupos. Regressão logística foi utilizada para combinar parâmetros. As áreas sob as curvas Receiver Operating Characteristic (ROC; AUC) foram calculadas para todos os parâmetros e as combinações. Comparações de pares das AUC foram realizadas com método de DeLong. Resultados: Foram encontradas diferenças estatisticamente significativas para a idade, residual leito estromal (RSB), espessura corneana central e BAD- D (p <0,001), mas não para a grau esférico, cilindro ou equivalente esférico (p > 0,05). ERSS foi de três ou mais em 12/23 olhos do grupo ectasia (sensibilidade = 52,17 %) e 48/ 266 olhos do grupo LASIK estável (18% falso positivo). BAD- D teve AUC de 0,931 (IC 95%: 0,895-0,957), com corte de 1,29 (sensibilidade=87%, especificidade=92,1%). A fórmula que combinou BAD-D, idade e RSB, gerou 100% de sensibilidade e especificidade de 94%, com melhor AUC (0,989, IC 95%: 0,969-0,998) do que todos os parâmetros individuais (p>0,001). Conclusão: BAD-D é mais preciso do que ERSS. Combinações de dados clínicos e os BAD-D melhorou a capacidade de identificação ...


Subject(s)
Humans , Adult , Middle Aged , Aged , Corneal Diseases/diagnosis , Corneal Diseases/etiology , Keratomileusis, Laser In Situ/adverse effects , Diagnostic Techniques, Ophthalmological/standards , Dilatation, Pathologic/diagnosis , Dilatation, Pathologic/etiology , Postoperative Complications/prevention & control , Preoperative Care , Predictive Value of Tests , Retrospective Studies , Risk Factors , ROC Curve , Risk Assessment , Cornea/surgery , Cornea/pathology , Corneal Topography
5.
Rev. bras. oftalmol ; 72(1): 54-58, jan.-fev. 2013. ilus
Article in Portuguese | LILACS | ID: lil-667600

ABSTRACT

Descrevemos a importância da tomografia de córnea e segmento anterior na propedêutica do exame complementar na avaliação de ectasia. Esta descrição da interpretação clínica dos índices da tomografia de córnea e segmento anterior (Pentacam - Oculus, Wetzlar, Germany) neste relato de caso, demonstra a relevância de uma nova tecnologia na avaliação da córnea e segmento anterior na suspeita de ceratocone. O diagnóstico de ceratocone foi excluído pela análise dos índices tomográficos de ectasia. Detectou-se assimetria entre os lados nasal e temporal por meio da avaliação do mapa de profundidade de câmara anterior. No exame biomicroscópico sob midríase foi constatado subluxação do cristalino, sendo assim devemos estar atentos não somente aos índices tomográficos corneanos na avaliação do exame complementar e sim analisarmos outros dados importantes oferecidos pela tomografia de córnea e segmento anterior.


The methodology currently used for interpretation of the cornea and anterior segment tomography for the diagnosis of corneal ectasia. Description of the clinical interpretation of anterior segment tomography (Pentacam - Oculus, Wetzlar, Germany); case report of the ectopia lentis demonstrating the importance o evaluation of the cornea and anterior segment of the keratoconus. We excluded the disease, analyzing the tomographic analysis of rates of ectasia and observe an asymmetry between nasal and temporal sides in assessing the depth map of the anterior chamber. On the biomicroscopic examination in mydriasis, was found a ectopia lentis. We must be mindful not only to corneal tomography indices to evaluate a diagnostic test, but look at other important information provided by anterior segment tomography.


Subject(s)
Humans , Male , Adolescent , Anterior Eye Segment , Corneal Topography , Dilatation, Pathologic , Keratoconus , Lens Subluxation/diagnosis , Tomography , Sensitivity and Specificity
6.
Rev. bras. oftalmol ; 71(5): 302-308, set.-out. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-654989

ABSTRACT

OBJETIVO: Utilização da metodologia para interpretação da tomografia de córnea e segmento anterior para a detecção e diagnóstico de ectasia corneana. MÉTODOS: Descrição da interpretação clínica dos índices da tomografia de córnea e segmento anterior (Pentacam High Resolution - Oculus, Wetzlar,Germany); relato de 3 casos, demonstrando a importância da propedêutica no exame complementar, através do Pentacam HR®. CONCLUSÃO: Nossa experiência compatibiliza-se com os relatos de literatura na demonstração do incremento de sensibilidade e especificidade para a detecção precoce de susceptibilidade e diagnóstico de ectasia corneana, utilizando a tomografia de córnea e segmento anterior.


PURPOSE: The methodology currently used for interpretation of the cornea and anterior segment tomography for the diagnosis of corneal ectasia and its susceptibility. METHODS: Description of the methodology and clinical interpretation of corneal and anterior segment tomography indexes; report of three cases demonstrating the importance of this new diagnostic tool (Pentacam HR®) in ophthalmological practice. CONCLUSION: The use of corneal and anterior segment tomography seems to be an effective method to increase the sensitivity and specificity for the diagnosis and early detection of corneal ectasia.


Subject(s)
Humans , Male , Female , Young Adult , Corneal Topography , Keratoconus/diagnosis , Cornea/pathology , Tomography , Dilatation, Pathologic/diagnosis , Sensitivity and Specificity
7.
Rev. bras. oftalmol ; 71(5): 317-321, set.-out. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-654992

ABSTRACT

OBJETIVO: Avaliar e comparar as alterações biomecânicas da córnea por meio do Ocular Response Analyzer® (ORA Reichert Ophtalmics Instruments, Buffalo, New York, USA) antes e após Lasik com Moriá ® Sub Bowman Keratomileusis (SBK) One Use Plus (OUP) em pacientes míopes e hipermetrópes. MÉTODOS: Foram estudados 33 olhos, sendo 19 olhos míopes e 14 olhos hipermetrópes submetidos à cirurgia refrativa com técnica Lasik com flap fino (100 µ) utilizando Moriá SBK OUP. O ORA foi realizado no pré-operatório e 1 mês após a cirurgia para avaliar a biomecânica da córnea. O CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (goldmann gold standard, Goldmann correlated intraocular pressure) a IOPcc (corneal compensated intraocular pressure) e mais 38 variáveis biomecânicas da córnea derivadas do sinal de resposta foram avaliados. O Teste de Kolmogorov-Smirnov foi utilizado para avaliar a distribuição normal. O teste de Wilcoxon foi utilizado para comparar as variáveis antes e após a cirurgia para cada grupo. As diferenças entre as medidas pré e pós-operatórias dos olhos míopes foram comparadas com as diferenças obtidas nos olhos hipermetrópes, utilizando-se o teste de Mann-Whitney. Foi considerado como estatisticamente significante p < 0,05%. RESULTADOS: Houve diferença significativa antes e após Lasik em olhos míopes e hipermetrópes na variável IOPg(Wilcoxon, p <0,05), porém não houve em IOPcc. Somente em olhos míopes houve diferenças significativas em CH e CRF, antes e após Lasik com Moriá SBK OUP, como também 9 parâmetros derivados do ORA Waveform_Sinal Gráfico (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p <0,05). Em olhos hipermetrópes houve diferenças antes e após Lasik das seguintes variáveis: aspect2, h2, dive2, mslew2 e H21 (Wilcoxon p<0,05).Diferenças nas variáveis IOPg e p1area, antes e após Lasik foram maiores em olhos míopes do que hipermetrópes (Mann-Whitey, p <0.05). CONCLUSÃO: Existem alterações das propriedades biomecânicas da córnea após Lasik com Moriá SBK OUP. Em geral, o impacto da biomecânica da córnea após Lasik em olhos míopes é maior do que em olhos hipermetrópes. As mudanças das variáveis relacionadas ao primeiro pico de aplanação (ORA waveform) são mais vistos em olhos míopes e as relacionadas ao segundo pico de aplanação em olhos hipermetrópes.


PURPOSE: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer®; Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. METHODS: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis - One Use Plus, Moria®).CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. RESULTS: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p <0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p <0, 05), 8 of these being related to the first sign of flattening.Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05).There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p <0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p <0.05). CONCLUSION: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.


Subject(s)
Humans , Cornea/physiology , Diagnostic Techniques, Ophthalmological , Hyperopia/surgery , Keratomileusis, Laser In Situ , Myopia/surgery , Biomechanical Phenomena/physiology , Observational Studies as Topic , Prospective Studies
8.
Rev. bras. oftalmol ; 70(6): 408-410, nov.-dez. 2011. ilus
Article in English | LILACS | ID: lil-612916

ABSTRACT

Different applications of trypan blue (TB) for intraocular surgery have been reported, with very high levels of safety and efficacy. We describe the use of TB as an alternative vital dye for staining the ocular surface to assess the integrity of superficial cell layers of the cornea and the surface environment. This facilitates the diagnosis of various ocular surface disorders, including screening for dry eye disease (DED) among refractive and cataract patients. TB staining properties are different from fluorescein and both are stable in a solution, so that a double staining technique is introduced.


Diferentes aplicações do azul de tripano (AT) foram descritas para cirurgia intraocular, com elevados patamares de eficácia e segurança. Neste relato, é descrito a aplicação do AT como corante vital para superfíce ocular, de modo a estudar a integridade das células da superfície corneana e conjuntival na superfície ocular. Tal abordagem permite um diagnóstico mais sensível de desordens da superfície ocular, destacando-se disfunção lacrimal ou síndrome do olho seco. O AT tem propriedades distintas da fluoresceína, com a qual se mantém estável em solução permitindo a técnica de coloração dupla que é introduzida.


Subject(s)
Humans , Staining and Labeling/methods , Trypan Blue/administration & dosage , Coloring Agents/administration & dosage , Eye Diseases/diagnosis , Ophthalmologic Surgical Procedures , Cohort Studies , Conjunctiva/pathology , Cornea/pathology , Fluorescein/administration & dosage , Slit Lamp Microscopy
9.
Rev. bras. oftalmol ; 70(3): 147-150, maio-jun. 2011. ilus, graf
Article in Portuguese | LILACS | ID: lil-596337

ABSTRACT

OBJETIVO:Correlacionar a densitometria do cristalino(PNS - patient nuclear score)por meio da imagem de Scheimplufgcom o tempo de facoemulsificação e o gasto de energia. MÉTODOS: Estudo observacional prospectivo, envolvendo 22 olhos de 22 pacientes que se submeteram à cirurgia de catarata por facoemulsificação com implante de lente intraocular. A densitometria do cristalino (PNS) foi medida através da tomografia de segmento anterior e córnea (Pentacam) no pré-operatório com a imagem de Scheimplufg. O tempo de facoemulsificação e o gasto de energia foram verificados e anotados ao término de cada cirurgia. O teste de correlação de Pearson foi utilizado para análise estatística através do programa Bioestat 5.0. Foi considerado como estatisticamente significante p < 0,05 por cento. RESULTADOS: As correlações entre PNS x Tempo de Facoemulsificação (s) e PNS x Gasto de Energia obtiveram respectivamente um p < 0,0050 e RP (Coeficiente de Pearson) de 0,5757 e p < 0,0029 e RP (Coeficiente de Pearson) de 0,6034. CONCLUSÃO: Observamos uma forte associação entre o método objetivo de classificação da catarata através da imagem de Scheimplufg (PNS), tempo e gasto de energia. Assim há possibilidade de realizarmos um planejamento cirúrgico pré-operatório baseado em métodos objetivos da classificação da catarata, reduzindo a fluídica, energia e tempo na cirurgia de facoemulsificação.


PURPOSE: To evaluate and to correlate the PNS (patient nuclear score) and time and energy (power US) in patients priorto and following phacoemulsification with intraocular lens implantation. METHODS: This is a prospective study. Twenty two consecutive patients (22 eyes) that underwent phacoemulsification surgery and intraocular lens implantation were enrolled. Full ophthalmologic clinical assessment including Pentacam (Oculus, Pentacam) measurements were performed in all cases prior to surgery (Pre). Excluison criteria were corneal disease or scars. RESULTS: There are statistically significant difference between PNS and Time with p < 0,0050 and PNS x Energy with p < 0,0029. CONCLUSION: Preoperatively adjusting phaco parameters based on cataract grade helped improve overall efficiency by reducing the amount of energy and fluid used in the eye and reducing overall phaco time.

10.
Rev. bras. oftalmol ; 70(2): 99-103, mar.-abr. 2011. tab
Article in Portuguese | LILACS | ID: lil-586708

ABSTRACT

OBJETIVO: Avaliar as indicações e os resultados do transplante de córnea em crianças na Fundação Altino Ventura (FAV). MÉTODOS: Foi realizado estudo retrospectivo em 33 pacientes (34 olhos), com idades igual ou inferior a 12 anos, que haviam sido submetidos a transplante penetrante de córnea entre 2000 e 2009 na FAV. A média dos tempos de seguimento pós-operatório foi de 32,5±23,2 meses (variando de 4 meses a 7 anos). Os dados analisados foram: indicação cirúrgica; acuidade visual para longe com melhor correção óptica (AVLc/c) no pré-operatório e na última consulta de seguimento, equivalente esférico refracional (EE) pós-cirurgia e complicações. Os resultados qualitativos foram expressos por suas frequências e os quantitativos por suas médias e desvios padrão. Utilizou-se o teste de t-Student para verificar possível diferença entre médias, aceitando-se o nível de significância de 95,0 por cento (p<0,05). RESULTADOS: A média das idades dos pacientes na cirurgia foi de 7,5 ± 3,3 anos (variando de 2 a 12 anos). Vinte e sete transplantes (79,4 por cento) tiveram indicação óptica e sete (20,6 por cento) tectônica ou terapêutica. A principal indicação entre os ópticos foi leucoma pós-trauma em dezoito (52,9 por cento). A acuidade visual melhorou em 21 (61,7 por cento) olhos e piorou em oito (23,5 por cento). Entre os transplantes ópticos, a rejeição esteve presente em quatro (14,8, por cento) olhos. Em quatro (11,8 por cento) olhos houve desenvolvimento de glaucoma. CONCLUSÃO: Na FAV, o leucoma pós-trauma foi a causa mais frequente de indicação do transplante de córnea em crianças, isto pode ser o resultado da baixa condição sócioeconômica e violência entre a população estudada. Uma proporção significativa de crianças cegas por problemas corneanos obteve melhora funcional da visão através do tratamento cirúrgico apropriado e bom acompanhamento no pós -operatório.


PURPOSE: To evaluate the indications and results after penetrating keratoplasty in children at Altino Ventura Foundation (FAV). METHODS: A retrospective study was performed in 33 patients (34 eyes), with ages equal or less than 12 years, they underwent a penetrating keratoplasty at FAV, from 2000 to 2009. The mean follow up time was 32.5 ± 23.1 months. Surgery indication, best corrected visual acuity (BCVA) before and after surgery, spherical equivalent (SE) pos surgical and complications were analyzed. The qualitative results were expressed by their frequencies and the quantitative by their means and standard deviations. The t-Student test was used to verify possible differences between means. The level of significance was 95.0 percent (p<0.05). RESULTS: Mean age at surgery was 7.5 ± 3.3 years. Twenty seven (79.4 percent) grafts had optical indication and seven (20.6 percent) therapeutic or tectonic. Among the optical transplants, the most frequent indication was cornea opacity after ocular trauma in 18 (52.9 percent) eyes. The visual acuity was better in 21 (61.7 percent) eyes and worse in eight (23.5 percent). In the optical transplants, rejection was present in four (14.8 percent) eyes, and four (11.8 percent) developed glaucoma. CONCLUSION: In FAV opacity after ocular trauma was the most common indication for pediatric keratoplasty. This may be the result of the low income and violent society, among the citizens from the studied population. Many blind children due to cornea disease may achieve improvement in visual acuity if an appropriate surgical and good postoperative management is performed.

11.
Rev. bras. oftalmol ; 70(1): 11-15, jan.-fev. 2011. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-581587

ABSTRACT

OBJETIVO: Verificar a variação das medidas pressóricas através do Ocular Response Analyzer (ORA, Reichert): IOPg (gold standard, Goldmann correlated intraocular pressure) e IOPcc (corneal compensated intraocular pressure) antes e após a cirurgia de catarata por facoemulsificação. MÉTODOS: Estudo observacional prospectivo envolvendo 47 olhos de 36 pacientes que se submeteram à cirurgia de catarata por facoemulsificação com implante de lente intraocular. A Pressão intraocular compensada da córnea (IOPcc) e correlacionada com Goldmann (IOPg), foram medidos pelo Ocular Response Analyzer (ORA); As medidas foram realizadas no pré-operatório, 1º dia e 30º dia após a cirurgia de facoemulsificação. O Teste de Kolmogorov-Smirnov foi utilizado para avaliar a distribuição normal. Diferenças obtidas entre as medidas obtidas através do Ocular Response Analyzer foram avaliadas pelo T-test (Student's paired t-test). Foi considerado como estatisticamente significante p < 0,05 por cento. RESULTADOS: As médias da IOPcc no pré-operatório, no primeiro dia e no trigésimo dia após a cirurgia de facoemulsificação e implante de LIO foram de 15.6 (±3.06), 15.5 (±3.14) , e 15.71 (±4.34). A média de IOPg no pré-operatório foi de 14.7 (± 3.0), no primeiro dia após cirurgia 12.9 (± 3.1) e no trigésimo dia 13.4 (± 3.7). Houve diferença significativa entre IOPg (PRE X D1) com p < 0,01. CONCLUSÃO: Observamos uma diminuição da IOPg no pós-operatório imediato em córneas com edema após facoemulsificação. Logo, ressaltamos a importância da biomecânica na medida da Pio.


PURPOSE: To evaluate the IOPg (gold standard, Goldmann correlated Intraocular pressure) and IOPcc (corneal compensated Intraocular pressure) in patients prior to and following phacoemulsification with intraocular lens implantation METHODS: This is a prospective study. Thirty six consecutive patients (47 eyes) that underwent phacoemulsification surgery and intraocular lens implantation were enrolled. Full ophthalmologic clinical assessment including Ocular Response Analyzer (ORA, Reichert Ophthalmic Instruments, Buffalo, NY, USA) measurements were performed in all cases prior to surgery (Pre) and at follow-up time points: day 1 and day 30. Exclusion criteria were corneal disease or scars, previous ocular surgery and patients with glaucoma or glaucoma suspect or ocular hypertension. Student's paired t-test was utilized. RESULTS: Mean and standard-deviation of ORA parameters were: IOPcc Pre was 15.6 (±3.06), day 1 (D1) 15.5 (±3.14) and day 30 (D30) 15.71 (±4.34). The mean of IOPg was Pre 14.7 (± 3.0), day 1 (D1) 12.9 (± 3.1), and day 30 (D30) was 13.4 (± 3.7). CONCLUSION: The reduction in the IOPg was observed in the immediate postoperative underestimating the real intraocular pressure ocular. We agree that biomechanical properties may have greater impact on IOP measurements error than corneal tchikness or curvature.


Subject(s)
Humans , Cornea/physiology , Diagnostic Techniques, Ophthalmological , Intraocular Pressure , Lens Implantation, Intraocular , Phacoemulsification , Biomechanical Phenomena , Prospective Studies
12.
Rev. bras. oftalmol ; 68(6): 348-354, nov.-dez. 2009. ilus
Article in Portuguese | LILACS | ID: lil-543767

ABSTRACT

Com base em modelos matemáticos e estudos experimentais estima-se que as medidas da PIO sejam linearmente hiperestimadas em córneas com maior espessura e menor ceratometria por meio de tonometria de aplanação de Goldmann (TAG). Entretanto, tal influência se dá de uma maneira mais complexa que a prevista por estes parâmetros geométricos, sendo diretamente relacionada com propriedades biomecânicas. O sistema de não contato ORA (Ocular response analyzer Reichert) permite estudo das propriedades biomecânicas juntamente com a medida pressórica calibrada para a TAG e a compensada da córnea. Adicionalmente, o estudo tomográfico com reconstrução tridimensional do mapa paquimétrico caracteriza a córnea de forma mais completa que a ceratometria anterior e espessura central. Neste artigo, relatamos um caso de dor ocular, fotofobia e baixa visão, 28 dias após cirurgia de facoemulsificação com implante de lente intraocular sem complicações em paciente feminina de 81 anos. Na primeira visita da paciente, enquanto a TAG era de 16 mmHg, o valor da PIO compensada da córnea (PIOcc), obtido com o ORA, era 25,6 mmHg. A histerese e fator de resistência da córnea eram baixos, 4,1 e 6,1mmHg respectivamente, apesar da paquimetria central ser relativamente mais elevada, de 601 micra. O padrão de distribuição espacial da espessura era atenuado, compatível com edema corneano que era observado também por meio das imagens de Scheimpflug (Pentacam). Com base nestes dados, foi feito diagnóstico de quadro de uveíte hipertensiva, associado à edema corneano, instituindo-se tratamento tópico com combinação fixa de maleato de timolol e brimonidina associado ao acetato de prednisolona. Três semanas após, a paciente apresentou-se com grande melhora da acuidade visual, resolução do edema corneano, e dos sintomas, normalizando os parâmetros biomecânicos, geométricos da córnea e de PIO.


Goldmann applanation tonometry (GAT) overestimates intraocular pressure (IOP) measurements in cases with thick and flatter corneas. This is thought to occur linearly based on mathematical and on experimental studies. However, such influence does exist, but this is more complex than the one anticipated by pachymetry and keratometry because it is related to corneal biomechanical properties. The ocular response analyzer (ORA Reichert) provides the data related to the biomechanical properties of the cornea along with the IOP measurements that are calibrated for correlating to the Goldmann applanation and also compensated from corneal properties. Also corneal tomography with a pachymetric map evaluation characterizes the cornea beyond central thickness and anterior curvature. In this article, we report a case of a 77 years old female patient with low vision, photofobia and ocular pain 28 days after phacoemulsification and intraocular lens implant. In the first visit, GAT was 14mmHg, while IOPcc (ORA corneal compensated IOP) was 25,6mmHg. Corneal hysteresis and resistance factor were low: 4,1 and 6,1mmHg respectively despite a central thickness of 601 micron. Corneal thickness spatial profile was attenuated with an edematous pattern that was also observed by the Scheimpflug images (Pentacam). Hypertensive uveitis was diagnosed and the patient was started on a fixed combination of timolol and brimonidine associate with prednisolone acetate. Three weeks after, the patient referred resolution of photofobia and marked improvement of vision. Clinically, edema was resolved as observed by corneal tomographyc and biomechanical findings.


Subject(s)
Humans , Female , Aged , Biomechanical Phenomena , Corneal Edema , Phacoemulsification/adverse effects , Intraocular Pressure , Models, Theoretical , Tonometry, Ocular , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL