Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Br J Med Med Res ; 2016; 16(11): 1-7
Article in English | IMSEAR | ID: sea-183401

ABSTRACT

Aims: The correct determination of a root canal length is a fundamental step for an adequate chemical-mechanical preparation and consequently, for a successful endodontic treatment. Electronic apex locators (EAL) were developed to provide fast and reliable working lengths. The aim of the present study was to analyze the accuracy of the Root ZX II, RomiApex A-15, and SmarPex EAL’s to determine the location of apical constriction, with and without the instructions recommended by the manufacturers. Methodology: Fifteen mandibular premolars were randomly selected and root canals were accessed. The real canal length was determined by introducing a #15 K-file until the tip was visualized in the apical foramen, using 40x magnification of an operative microscope. In the sequence, the teeth were inserted in plastic flasks containing floral foam soaked in 0.9% saline solution. The root canals were filled with 1% sodium hypochlorite and the electronic measures were obtained with the selected devices until the “0.0” or the last green bar mark, as showed in devices display, and as per the manufacturers settings recommendation. The data were submitted to statistical analysis with the Friedman and Wilcoxon tests with a 0.05% significance level (p < 0.05). Results: All devices were similar (p > 0.05) and showed precise and acceptable measurements at both times. Without manufacturers setting recommendation, the Root ZX II was the EAL that presented the greater percentage of coincidences with the real teeth length measures (73.33%), followed by the RomiApex A-15 (66.66%) and the SmarPex (40%). After performing the recommended settings the Root ZX II and the SmarPex presented 86.66% of coincidence with the real length, however, only the SmarPex device enhanced the mean precision with the real length (p < 0.05). Conclusion: Considering a clinically acceptable average error of ±0.5 mm, all devices were effective in determining the measurement until the apical constriction. Although, there were no statistical significant difference with and without manufacturers instruction, for Root ZX II, the performance was better when manufacturer instructions were followed.

2.
Article in English | IMSEAR | ID: sea-178048

ABSTRACT

Context: This study was carried out on the assumption that calcium hydroxide [Ca(OH)2] dressing and irrigants may influence the obturation of lateral canals. Aims: To evaluate the influence of 2.5% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX) gel and Ca(OH)2 on the filling of artificial lateral canals. Settings and Design: Ex vivo quantitative laboratory study. Materials and Methods: Forty‑two human mandibular premolars were selected. After cavity access, six lateral canals were performed, two in each root section, one mesial and one on the distal root surface. After preparation, the specimens were randomly divided into four groups: Group I: Under irrigation with 2% CHX and saline solution and with intracanal dressing Ca(OH)2 paste; Group II: The same preparation as Group I, but without Ca(OH)2; Group III: Under irrigation with 2.5% NaOCl without Ca(OH)2; and Group IV: The same preparation as Group III, but with Ca(OH)2. Two teeth without intracanal dressing were used as negative controls. Lateral condensation technique was performed. Then, digital radiographic images were obtained. Statistical Analysis Used: Data were analyzed using SPSS 17.0, submitted to Kappa (reliability between examiners) and Kruskal–Wallis test. Results: No statistical difference was registered between Groups II and III in all root sections (P > 0.05), but it was observed between Groups I and IV (P < 0.05), except on the apical section (P > 0.05). In all sections, the Group I filled more artificial lateral canals than in Group IV. Conclusions: The irrigants tested had no influence on the filling of artificial lateral canals. Nevertheless, intracanal dressing of Ca(OH)2 influenced this filling.

3.
Braz. dent. j ; 24(5): 482-486, Sep-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697635

ABSTRACT

This study evaluated the influence of apical patency, root filling removal technique and cleaning of the apical foramen, concerning the amount of debris extruded during root canal retreatment. Forty mandibular incisors were randomly assigned to 4 groups - GIM (n=10), GIIM (n=10), GIPT (n=10) and GIIPT (n=10), which were named according to leaving (I) or not (II) apical patency during canal preparation and filling removal technique (manual - M or ProTaper system - PT). After filling material removal, each specimen of each group had the apical foramen cleaned by sizes 15, 20 and 25 instruments, generating 12 subgroups: GIM15, GIM20, GIM25, GIIM15, GIIM20, GIIM25, GIPT15, GIPT20, GIPT25, GIIPT15, GIIPT20 and GIIPT25. Extruded filling debris was collected by a Milipore filtration system, an HV-durapore, 0.45 µm pore filter with a 25 mm diameter. The filters were weighed before and after the collection on an analytical scale (10–5 g), and the difference was calculated. The mean weight of extruded filling debris was analyzed statistically by Kruskal-Wallis and Friedman ANOVA tests (α=0.05). The mean values found in the groups (in mg) were: GIM (0.95±0.94), GIIM (0.47±0.62), GIPT (0.30±0.31) and GIIPT (0.32±0.44). There was no statistically significant difference among any of the groups or subgroups (p>0.05). ProTaper provided the smallest amount of extruded filling material, regardless of presence or absence of apical patency, followed by manual technique, without and with apical patency. Additional amounts of debris were collected during cleaning of the apical foramen, regardless of the instrument, presence/absence of patency or root filling removal technique.


Este estudo verificou a influência da patência apical, técnica de desobturação e limpeza foraminal na quantidade de material sólido extruído, durante retratamento endodôntico. Quarenta incisivos inferiores foram divididos aleatoriamente em quatro grupos - GIM (n=10), GIIM (n=10), GIPT (n=10) e GIIPT (n=10) - nomeados de acordo com a realização (I) ou não (II) de patência apical durante o preparo de canais e a técnica de desobturação - manual (M) ou sistema ProTaper (PT). Após a desobturação, realizou-se a limpeza foraminal em cada espécime de todos os grupos com instrumentos #15, #20 e #25, gerando 12 subgrupos: GIM15, GIM20, GIM25, GIIM15, GIIM20, GIIM25, GIPT15, GIPT20, GIPT25, GIIPT15, GIIPT20 e GIIPT25. O material sólido extruído foi coletado pelo sistema de filtração Millipore®, com filtros de 0,45 µm de poro e 25 mm de diâmetro. Os filtros foram pesados antes e após a coleta, em balança analítica de precisão (10–5g), e as diferenças foram calculadas. Os valores médios encontrados (em mg) foram: GIM (0,95±0,94), GIIM (0,47±0,62), GIPT (0,30±0,31) e GIIPT (0,32±0,44), sem diferença estatística entre quaisquer dos grupos ou subgrupos (p>0,05). O sistema Protaper proporcionou a menor quantidade de material sólido extruído, independente da presença ou não de patência apical seguidos da técnica manual sem e com patência apical. Quantidades adicionais foram coletadas durante a limpeza foraminal, independente do instrumento utilizado, da presença ou não da patência apical ou da técnica de desobturação.


Subject(s)
Humans , Root Canal Preparation/methods , Tooth Apex/physiology , Root Canal Filling Materials
4.
Braz. j. oral sci ; 12(2): 138-142, Apr.-June 2013. ilus
Article in English | LILACS, BBO | ID: lil-694433

ABSTRACT

Aim: To compare the effectiveness of different obturation techniques in surpassing the ledgeformed in simulated curved root canals. Methods: Eighty acrylic-resin blocks with curved canalswere instrumented with Gates-Glidden drills to simulate a ledge formation. Then, a K-File #10 wasused for trying to surpass the deviation, and the blocks that permitted surpassing were rejected.The remaining blocks were divided into 4 groups according to the obturation technique: lateralcondensation, Tagger’s Hybrid technique, Thermafil and System B. The blocks had their imagesdigitalized using a scanner before and after the obturation procedures. The images were analyzedwith Image Tool 3.0 software. Statistical analysis was performed by one-way ANOVA at a significantlevel of 5%. Results: The System B resulted in the highest obturated area (p<0.001). Therewere no significant differences between the Tagger’s Hybrid technique and Thermafil systemregarding the effectiveness in surpassing ledge (p>0.05). The lateral condensation resulted in theworst ability in filling the ledge space (p<0.001). Conclusions: Within the limitations of this study,it was possible to conclude that techniques using heat condensation or gutta-perchathermoplastification were more effective in surpassing the ledge formed in curved canals than thelateral condensation.


Subject(s)
Endodontics , Root Canal Filling Materials , Root Canal Obturation , Root Canal Therapy
5.
Dent. press endod ; 3(1): 68-72, 2013. ilus
Article in Portuguese | LILACS, BBO | ID: lil-688936

ABSTRACT

Introdução: pacientes com distúrbios hemorrágicos precisam de cuidados especiais quando submetidos a procedimentos odontológicos. Objetivos: fornecer informações sobre como tratar um paciente com um diagnóstico provável da doença de von Willebrand e abscesso periapical agudo no dente 23. Métodos: paciente do sexo feminino, leucoderma, 35 anos de idade, se dirigiu ao Pronto Atendimento Odontológico da Faculdade de Odontologia da Universidade Federal do Paraná, apresentando cárie extensa abaixo do nível gengival, projetando-se para o palato, também com fratura da coroa, expondo o canal radicular ao meio bucal. A atenção estava focada em isolar o campo operatório, o que não poderia ser feito de forma convencional devido à extensão da cárie, à proliferação de tecido gengival e às condições sistêmicas do paciente. Conclusão: a estratégia utilizada nesse caso foi eficaz na gestão da coagulopatia e permitiu cuidados de emergência a serem realizados sem complicações.


Subject(s)
Humans , Female , Adult , Periapical Abscess/surgery , Emergency Treatment , Endodontics , Root Canal Therapy , von Willebrand Factor
6.
Dent. press endod ; 1(1): 58-63, 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-685764

ABSTRACT

Objetivo: este estudo analisou a efetividade do preenchimento do canal radicular com pasta de hidróxido empregando o propulsor de Lentulo, acionado em diferentes velocidades.Métodos: trinta pré-molares inferiores tiveram seus canais radiculares preparados até o instrumento #50 e divididos aleatoriamente em três grupos. Pasta de hidróxido de cálcio preparada com solução fisiológica foi inserida nos canais radiculares empregando-se um propulsor de Lentulo, acionado com velocidades de 5.000 rpm (G1), 10.080 rpm(G2) e 15.000 rpm (G3). A densidade óptica foi determinada utilizando-se o sistema de radiografia digital (Kodak Dental RGV-5000). Resultados: a maior densidade óptica obtida no terço apical foi no G3, e nos terços médio e cervical no G1. Por meio do teste Kruskal-Wallis-Anova, observou--se diferença estatística (p<0,05) entre o G1 e G3 no terço apical, e G1 e G2 no terço médio, mas nenhuma diferença estatística foi observada no terço cervical (p>0,05).Conclusão: velocidades diferentes são necessárias para o correto preenchimento de canais radiculares com pasta de hidróxido de cálcio. A velocidade de 15.000 rpm foi mais efetiva no preenchimento do terço apical e a velocidade de 5.000 rpm foi mais efetiva no preenchimento dos terços médio e cervical.


Objective: This study analyzed the effectiveness of fillingthe root canal with calcium hydroxide paste using the Lentulospiral at different speeds. Methods: Thirty mandibularpremolars after root canal preparation were divided in threegroups. Calcium hydroxide paste was inserted in the rootcanals with a Lentulo spiral at 5,000 rpm (G1), 10,000 rpm(G2) and 15,000 rpm (G3). The optical density was determinedby the use of the digital radiography system KodakDental RGV-5000. Results: The highest optical densityobtained in the apical third was in G3 and in the middle andcervical third in G1. Statistical difference (Kruskal-Wallis -Anova) was observed (p<0.05) between G1 and G3 in theapical third and G1 and G2 in the middle third. No differencewas observed in the cervical third (p>0.05). Conclusion:Different speeds are necessary for the correct fillingof the root canal with calcium hydroxide paste. The 15,000rpm speed was more effective in filling the apical third and5,000 rpm speed was more effective in filling the cervicaland middle thirds.


Subject(s)
Endodontics/methods , Calcium Hydroxide , Root Canal Irrigants , Root Canal Filling Materials , Root Canal Therapy
7.
Dent. press endod ; 1(2): 64-69, 2011. ilus
Article in Portuguese | LILACS | ID: lil-685798

ABSTRACT

O objetivo deste artigo foi relatar dois casos clínicos de segundos molares inferiores apresentando sistemas de canais radiculares em forma de C. As etapas dos tratamentos foram descritas e comparadas com as variações encontradas na literatura. Os canais foram preparados com um sistema automatizado de rotação alternada e obturados com o sistema Epiphany com o auxílio dos compactadores de McSpadden


Subject(s)
Dental Pulp Cavity/anatomy & histology , Dental Pulp Cavity/abnormalities , Root Canal Obturation , Tooth Root/abnormalities , Root Canal Therapy/methods
8.
RGO (Porto Alegre) ; 57(1): 7-11, jan.-mar. 2009. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-873761

ABSTRACT

Objetivo: Avaliar o perfil de escoamento de seis cimentos obturadores endodônticos, por meio do teste de escoamento vertical: N-Rickert (Fórmula e Ação, São Paulo, Brasil), Endofill (Dentsply, Petrópolis, Brasil), Óxido de Zinco e Eugenol (SS White, Rio de Janeiro, Brasil), AHPlus (Dentsply, Petrópolis, Brasil), EndoRez (Ultradent, South Jordan, UT, USA) e Intra-Fill (SS White, Rio de Janeiro, Brasil). Métodos: O teste de escoamento foi realizado utilizando placas duplas de vidro polidas de 30 x 26 cm, para abrigar as amostras de 0,1 ml dos cimentos. As amostras foram depositadas na parte superior com o auxílio de seringa para insulina. As placas foram levadas para a estufa a 37° e umidade relativa de 100%. O escoamento foi medido por meio de uma folha de papel milimetrado entre as placas de vidro, nos tempos de 10 minutos, 20 minutos, 30 minutos, uma hora, duas horas, três horas, quatro horas, cinco horas, seis horas, 12 horas, 24 horas e 48 horas. Resultados: Endofill (Dentsply, Petrópolis, Brasil) apresentou escoamento de 69,3mm, seguido do N-Rickert (Fórmula e Ação, São Paulo, Brasil) (43,0mm) e do AH-Plus (Dentsply, Petrópolis, Brasil) (29,3mm). Os cimentos Intrafill (SS White, Rio de Janeiro, Brasil), Óxido de Zinco e Eugenol (SS White, Rio de Janeiro, Brasil) e EndoRez (Ultradent, South Jordan, UT, USA) não apresentaram escoamento. N-Rickert (Fórmula e Ação, São Paulo, Brasil) e Endofill (Dentsply, Petrópolis, Brasil) tiveram comportamentos semelhantes, não necessitando de força inicial para se deslocar. O cimento N-Rickert (Fórmula e Ação, São Paulo, Brasil) escoou até trinta minutos e o Endofill (Dentsply, Petrópolis, Brasil) até a segunda hora de observação. O escoamento inicial do AH-Plus (Dentsply, Petrópolis, Brasil) foi de 0,8mm até três horas, permanecendo estável a partir da quinta hora. Conclusão: Os cimentos Óxido de Zinco e Eugenol (SS White, Rio de Janeiro, Brasil), Intrafill (SS White, Rio de Janeiro, Brasil)...


Objective: To assess the flow characteristic of six endodontic filling cements by means of the vertical flow test: N-Rickert (Fórmula e Ação, São Paulo, Brazil), Endofill (Dentsply, Petrópolis, Brazil), Zinc Oxide and Eugenol (SS White, Rio de Janeiro, Brazil), AH-Plus (Dentsply, Petrópolis,Brazil), EndoRez (Ultradent, South Jordan, UT, USA) and Intra-Fill (SS White, Rio de Janeiro, Brazil). Methods: Flow test was performed by placing the 0.1 ml samples of cements between two plates of polished glass measuring 30 x 26 cm. The samples were deposited on the top part with aid of a insulin syringe. The plates were taken to an oven at 37° and relative humidity of 100%. Flow was measured by means of a sheet of millimetric paper placed between the glass plates, at time intervals of 10 minutes, 20 minutes, 30 minutes, one hour, two hours, three hours, four hours, five hours, six hours, 12 hours, 24 hours and 48 hours. Results: Endofill (Dentsply, Petrópolis, Brazil) showed flow of 69.3mm, followed by N-Rickert (Fórmula e Ação, São Paulo, Brazil) (43.0mm) and AH-Plus (Dentsply, Petrópolis, Brazil) (29.3mm). The cements Intrafill (SS White, Rio de Janeiro, Brazil), Zinc Oxide and Eugenol (SS White,Rio de Janeiro, Brazil) and Endo Rez (Ultradent, South Jordan, UT, USA) presented no flow. N-Rickert (Fórmula e Ação, São Paulo, Brazil) and Endofill (Dentsply, Petrópolis, Brazil) behaved similarly, and needed no initial force to become displaced. The cement N-Rickert (Fórmula eAção, São Paulo, Brazil) flowed for up to thirty minutes and Endofill (Dentsply, Petrópolis, Brazil) up to the second hour of observation. Initial flow of AH-Plus (Dentsply, Petrópolis, Brazil) was 0.8mm up to three hours, remaining stable after the fifth hour. Conclusion: The cements Zinc Oxide and Eugenol (SS White, Rio de Janeiro, Brazil), Intrafill (SS White, Rio de Janeiro, Brazil) and EndoRez (Ultradent, South Jordan, UT, USA) did not present any flow during the experiment. The greatest flow was...


Subject(s)
Dental Cements/chemistry , Endodontics
9.
Rev. odonto ciênc ; 23(4): 338-341, out.-dez. 2008. tab
Article in Portuguese | LILACS, BBO | ID: lil-500147

ABSTRACT

Objetivo: O presente estudo teve por finalidade analisar a radiopacidade de alguns cimentos endodônticos utilizando um sistema de radiografia digital. Metodologia: Foram testados os cimentos endodônticos AH-Plus, N-Rickert, Endofill, Óxido de zinco e eugenol (OZE) e Intrafill. Seis corpos-de-prova cilídricos (1x0,5cm) para cada cimento foram confeccionados e armazenados a 37ºC e umidade relativa de 100%, durante 72h. Os corpos-de-prova foram posicionados na região central do sensor do sistema digital Kodak RVG 5000 e o cilindro do aparelho radiográfico foi posicionado perpendicularmente a uma distância focal de 5cm, com tempo de exposição de 0,05 segundos. A partir da imagem digital obtiveram-se os valores da densidade óptica em pixels da região central e pontos eqüidistantes à direita e à esquerda de cada corpo-de-prova. Os dados foram analisados por ANOVA e teste de Tukey (α=0,05). Resultados: Houve diferença estatística entre todos os cimentos, com exceção da comparação entre o Intrafill e o Endofill. A radiopacidade dos cimentos em ordem crescente foi: ZOE < Endofill = Intrafill < N-Rickert < AH-Plus. Conclusão: O método de radiografia digital foi sensível para detectar diferenças de radiopacidade entre os cimentos endodônticos analisados.


Purpose: This study aimed to evaluate the radiopacity of some endodontic sealers using a digital radiograph system. Methods: The endodontic sealers tested were: AH-Plus, N-Rickert, Endofill, Óxido de zinco e eugenol (OZE), and Intrafill. Six cylindrical-shaped specimens (1x0.5cm) were fabricated with each material and stored at 37ºC and 100% relative humidity for 72h. Each specimen was placed at the central area of the sensor of the digital system Kodak RVG 5000, and the X-ray cylinder was positioned perpendicularly at a 5cm-focal distance with time of exposure of 0.05s. The digital image software was used to measure optical density in pixels of the specimens at their central area and at the right and left sides. Data were analyzed by ANOVA and Tukey test (α=0.05). Results: There was a statistically significant difference of radiopacity among the tested materials, except for the comparison between Intrafill and Endofill. The level of radiopacity in ascending order was: ZOE < Endofill = Intrafill < N-Rickert < AH-Plus. Conclusion: The digital radiograph method was sensitive to detect differences of radiopacity among the tested endodontic sealers.


Subject(s)
Dental Pulp Cavity , Dental Cements , Root Canal Filling Materials , Radiography, Dental, Digital
10.
ROBRAC ; 17(44): 166-173, dez. 2008. tab, ilus
Article in Portuguese | LILACS | ID: lil-524016

ABSTRACT

O objetivo do presente estudo foi avaliar a capacidade de remoção do material obturador nos retratamentoscom o sistema Protaper Universal-Retratamento e com técnica híbrida manual auxiliada pelos instrumentosPré-Race. Foram selecionados vinte e quatro dentes humanos incisivos inferiores com comprimentos entre19 e 21mm os quais foram preparados e obturados, e armazenados em ambiente de umidade relativa de100% por 180 dias. Completado este período, os dentes foram radiografados individualmente no sentidomesio-distal e vestíbulo-lingual e divididos aleatoriamente em dois grupos. Os dentes do Grupo 1 foramdesobturados empregando-se os instrumentos Protaper Universal - Retratamento, D1, D2 e D3 seguindoseo preparo com instrumentos F1 e F2; no Grupo 2 os dentes foram desobturados empregando-se técnicahíbrida manual com auxilio dos instrumentos Pré-Race. Os dentes foram novamente radiografados em ambosos sentidos, as imagens digitalizadas e a medição linear das paredes foram realizados pelo softwareImage Tool 3.0. Os resultados mostraram diferenças estatisticamente significantes no remanescente quandoProtaper Universal - Retratamento foi empregado e com o uso de F1 e F2 em ambos os sentidos. A técnicahíbrida manual apresentou melhores resultados.


The aim of this study was to evaluate the ability of the Protaper Retreatment and a hybrid manualtechnique on removing the root canal filling during retreatment. Twenty-four human incisors teeth were selected,prepared and filled with gutta-percha and Endo Fill cement in a lateral condensation technique andstored for 180 days. The teeth were radiographed mesio-distally and bucco-lingually , and digitalized. Theteeth were divided into two groups. In Group 1 retreatment were performed with the Protaper Universal - RetreatmentD1, D2 and D3. An x-ray showed the remaining of endodontic filling material. A Protaper F1 andF2 were used to complete the removal. In group 2 hybrid manual techniques with Pré-Race instruments forthe radicular access were performed. Before and after retreatment the x-rays were digitalized and the linearrate determined with the Image Tool 3.0 software. The results showed statistically difference between theremaining filling material when Protaper Universal - Retreatment was employed and when Protaper F1 andF2 in both view. Hybrid manual technique showed the best results when compared with the use of PT-R F1and F2 but showed similar results when compared to Protaper Universal Retreatment.

11.
ROBRAC ; 17(43): 1-12, jun. 2008. ilus, tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-525096

ABSTRACT

As grandes dificuldades durante o preparo estão em função direta de aspectos anatômicos presentescomo curvaturas e atresias, tornando-se o grande desafio a ser vencido. Canais de diâmetros reduzidosdevido a calcificações dificultam a progressão dos instrumentos no alargamento, e canais com curvaturasacentuadas tornam a sua manutenção crítica. O conceito de acesso radicular introduzido por Goering em1982 é um passo extremamente importante, independente da técnica de preparo a ser empregada, visandoa eliminação de depósitos dentinários na entrada dos canais radiculares e propiciando um acesso diretoaos terços médio e apical. As brocas de Gates-Glidden tem sido o instrumento mais utilizado para este fim.Recentemente, instrumentos com diferentes conicidades têm sido introduzidos para serem empregadoscom contra-ângulo convencional: a Coronal Preparation Drill - CP Drill (Injecta), os instrumentos LA Axxess(Sybron-Kerr) e os instrumentos Pré-Race (FKG). No presente artigo os autores discutem e analisam aeficiência clínica destes instrumentos apontando para o seguinte resultado em ordem decrescente: Pré-Race, CP Drill e LA Axxess.


Difficulties during root canal preparation are related to anatomic aspects as curvatures and atresias,which are a challenge to overcome. Calcifications at the entrance and atresic root canals make the instrumentsaction difficult and great curvatures are not easy to be maintained. The radicular access introduced by Goeringin 1982 is an extremely important step to any root canal preparation technique, eliminating dentin from theentrance and getting a straight access to the middle and apical third. Gates-Glidden bur has been the mostemployed instrument to the radicular access. Recently, instruments showing different conicities have beenintroduced to be used with the normal angle: CP Drill, LA Axxess and Pre-Race. This paper discussed andanalyzed the clinical efficiency of these instruments and observed the following result, in decreasing order:Pre-Race, CP Drill and LA Axxess.

12.
ROBRAC ; 16(42): [1-11], dez. 2007. ilus, tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-525062

ABSTRACT

O objetivo deste trabalho foi avaliar a capacidade do MTA e o do hidróxido de cálcio de evitar asobre-obturação de guta-percha e cimento quando empregados como plug apical em dentes com ápiceincompletamente formado. Foram selecionados 24 dentes monoradiculares, incisivos centrais superiores epré-molares inferiores com ápice completo, que através de desgastes com brocas apropriadas, simulou-sea anatomia apical de dente imaturo. Os dentes foram inseridos em alvéolos artificiais e plugs apicais foramrealizados com MTA ou com hidróxido de cálcio e os canais obturados com cones moldados. Radiografiasnos sentidos mésio-distal e vestíbulo-lingual foram realizados e analisadas quanto à capacidade dos plugsde evitar extravasamento da obturação. Os resultados mostraram que o plug apical com MTA foi mais efetivoque o do hidróxido de cálcio, não ocorrendo extravasamento em nenhum caso, ao passo que no grupo doplug apical com o hidróxido de cálcio, houve o rompimento do plug em quatro casos, porém sem extrusãoda obturação.


The aim of this study was to evaluate the ability of the MTA and calcium hydroxide to avoid overextension of theguta-percha and sealer when used as an apical plug in teeth with imature apexes. Twenty-four monoradicularteeth with complete root formation were selected, and an incomplete apex was created through a specificconical bur. The teeth were placed in a artificial socket an the apical plug created with both materials. Rootcanals were filled with guta-percha and cement and the teeth radiographed in the mesial-distal and bucolingualview. The x-rays were analysed about the ability to avoid overextension of the filling materials. Theresults showed that MTA was more efficient on avoiding overextension than calcium hidroxide.

13.
RSBO (Impr.) ; 1(1): 14-16, nov. 2004. ilus
Article in Portuguese | LILACS, BBO | ID: lil-510862

ABSTRACT

A variação da posiçãodo forame apical, somada às estruturas radiopacas da região óssea, quase sempre dificulta sua identificação por meio do exame das radiografias, podendo alterar o prognóstico do tratamento. O objetivo deste trabalho foi avaliar visual e radiograficamente a posição do forame e a mensuração quando este não se posicionar no ápice. Foram utilizados 100 caninos superiores monorradiculados. Após a realização do acesso endodôntico os dentes foram explorados com uma lima tipo K # 10 até sua observação no forame. Em seguida o dentes foi radiografado e realizaram-se as medidas com um paquímetro digital tanto no dentes como no raio X. Os resultados mostraram que 58% dos dentes apresentaram raízes curvas, e em 22% a curva era por vestibular. Na análise radiográfica verificou-se que em 64% o forame localizava-se no ápice; já visualmente apenas 44% encontrava-se no ápice. Com relação à distância visual versus radiográfica constatou-se que em 43% dos casos havia correspondência entre elas, enquanto em 12% dos casos a distância radiográfica foi três vezes superior à visual. Conclui-se com o presente estudo que a visualização radiográfica do forame no ápice nem sempre condiz com a realidade, devendo-se levar em consideração o conhecimento anatômico durante o tratamento endodôntico.


Subject(s)
Tooth Apex , Anatomy
14.
Rev. bras. odontol ; 60(5): 353-356, set.-out. 2003. tab
Article in Portuguese | LILACS, BBO | ID: lil-404170

ABSTRACT

Tendo como base a norma ISO/DIS 6876.2, reedição da norma da ADA n° 57 foram avaliadas diferentes propriedades físico-químicas de cinco cimentos obturadores de canais radiculares comumente empregados na clínica diária: Óxido de Zinco e Eugenol, Endométhasone Endofill, AH Plus e Sealer 26. Os cimentos analisados apresentaram valores de escoamento, tempo de trabalho, tempo de presa, solubilidade e radiopacidade que satisfazem a norma ISO/DIS 6876.2


Subject(s)
Dental Cements/standards , Root Canal Obturation/standards , Zinc Oxide/standards , Chemical Phenomena
15.
Rev. odontol. UNICID ; 14(1): 15-23, jan.-abr. 2002. tab
Article in Portuguese | LILACS, BBO | ID: lil-329279

ABSTRACT

Avaliou-se a eficiência de dois métodos experimentais em coletar material extruído além do forame apical, durante o preparo químico-cirúrgico: esponjas de poliuretano e sistema de filtraçäo Millipore, utilizando-se filtros 0,45 µm de poro, sendo, neste estudo, este método complementar àquele. O sistema de filtraçäo Millipore foi o que apresentou melhor resultado na coleta de material sólido proveniente do canal radicular, porém mostrou-se ineficiente para coletar a parte líquida do material extruído, ao passo que o método da esponja de poliuretano coletou parcialmente o material sólido e líquido


Subject(s)
Root Canal Therapy , Tooth Movement Techniques
16.
Säo Paulo; s.n; 2001. 81 p. ilus, tab, graf. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-308227

ABSTRACT

O respeito aos tecidos periapicais é fundamental ao sucesso da terapia endodôntica. Nesse contexto, o presente estudo teve como objetivo comparar a quantidade de resíduos sólidos extruídos por meio de duas diferentes técnicas de instrumentaçäo mecânico-rotatórias, variaçäo de conicidade (Grupo A) e coroa-ápice (Grupo B), valendo-se de limas de Ni-Ti (Quantec LX). Quinze incisivos inferiores humanos foram utilizados para cada grupo. O material sólido extruído foi coletado por meio do sistema de filtraçäo Millipore com filtros de 0,45 µm de poro, submetidos a secagem em estufa e pesagem em balança analítica de precisäo. Os resultados mostraram que, em ambas as técnicas, houve extrusäo de material além do forame apical, porém, quando analisados estatisticamente, observou-se diferença significante (alfa=0,01) entre os dois grupos. A instrumentaçäo cérvico-apical produziu em média 0,20 mg de material sólido extruído, sendo mais eficaz na prevençäo da extrusäo do que a variaçäo da conicidade, a qual apresentou 0,44 mg


Subject(s)
Dental Pulp Cavity , Dental Instruments , Tooth Movement Techniques
SELECTION OF CITATIONS
SEARCH DETAIL