Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Arch. cardiol. Méx ; 77(2): 110-119, abr.-jun. 2007. tab
Article in Spanish | LILACS | ID: lil-566703

ABSTRACT

We evaluated immediate and mid-term clinical and angiographic results in diabetic patients with percutaneous coronary intervention with deployment of drug eluting stents. METHODS: Between November of 2004 and June of 2005 percutaneous coronary interventions were performed 860 with the deployment of 112 drug eluting stents to 42 diabetic patients. The mean of stents was 2.6 per patient, and the type of drug eluting stent was paclitaxel in 60% and sirolimus in 40%. The average of age was 51.2 +/- 9.6 years old. The gender was male in 25 (60%) of patients and female in 17 (40%). The indication of coronary angiography was unstable angina in 15 (35%) patients and stable angina in 27 (65%). There was history of anterior myocardial infarction in 20 (47%), inferior myocardial infarction in 8 (20%) and multiple vessel disease in 16 (38%). The stenosis severity of the lesion was 85.9% +/- 12.2% and the left ventricular function was (55 +/- 10). The hospital stay was 7 +/- 5.4 days. RESULTS: Both clinical and angiographic immediate success was 100%. The average follow was 7.6 +/- 3.3 months in 34 patients (80.9%). The target lesion revascularization (TLR) was 7.1%. (3 patients). Death, myocardial infarction or reinfarction (0%). COMPLICATIONS: One patient (2.3%) developed contrast induced nephropathy. CONCLUSIONS: These results suggest that the use of drug eluting stents (paclitaxel or sirolimus) in diabetic patients has a high rate of success with good angiographic and clinical results and with a low rate of complications or restenosis in this high risk group of patients.


Subject(s)
Female , Humans , Male , Coronary Restenosis , Drug Delivery Systems , Stents , Diabetic Angiopathies
2.
Arch. cardiol. Méx ; 76(1): 28-36, ene.-mar. 2006.
Article in Spanish | LILACS | ID: lil-569530

ABSTRACT

Since the last decade, percutaneous balloon mitral valvuloplasty with Inoue catheter is considered the treatment of choice for selected patients (mobile valve, no calcification and minimal subvalvular disease) with rheumatic mitral stenosis. OBJECTIVE: We present the seven-year follow-up experience of 456 patients treated with this technique in the catheter laboratory of the Cardiology Hospital in National Medical Center SXXI. MATERIAL AND METHODS: It is a retrospective, transversal and observational study performed with data obtained from January 1994 and December 2000, with a follow-up of 58.5 +/- 26.6 months (range 12-96 mean 22). RESULTS: We achieve an initial success of 82.8%, improvement of initial mitral valve area from 0.9 +/- 0.1 to 1.8 +/- 0.3 cm2, with a gain area from 88 to 106% (p < or = 0.001). At the end of the follow-up, the mean valvular area was maintained in 1.7 +/- 0.3 cm2 in 69.8% of the cases. We found a significant reduction of transmitral gradient and of the pulmonary artery systolic pressure immediately after the procedure; 93.1% of patients were in NYHA functional class II at the end of the follow-up, 11.6% presented complications (mitral regurgitation as the most important), in 15.9% of them, due to leaflet rupture, but only 9.1% corresponded to severe grade Ill-IV. COMPLICATIONS: Only one patient died due to septal perforation; 93.8% of the patients remained free of major cardiac events at the end of the study. Only 6.1% of the patients required surgery at the end of the follow-up; 5.5% were in functional class NYHA Ill-IV and restenosis occurred in 14.6%. CONCLUSION: Percutaneous balloon mitral valvuloplasty with Inoue balloon catheter is a safe and effective technique for treating rheumatic mitral stenosis with Wilkins score < 10, with minimal risk and complications and offers good life expectancy with absence of major cardiac events in > 90%. From these patients, 93.1% remained in NYHA-II or -I functional class and the incidence of restenosis decreased.


Subject(s)
Adult , Female , Humans , Male , Catheterization , Mitral Valve Stenosis , Cross-Sectional Studies , Disease-Free Survival , Hospitals, Special , Retrospective Studies , Time Factors
3.
Arch. cardiol. Méx ; 75(3): 279-289, jul.-sep. 2005. tab
Article in Spanish | LILACS | ID: lil-631901

ABSTRACT

Evaluamos los resultados clínicos, angiográficos y el seguimiento en pacientes que fueron sometidos a angioplastía coronaria transluminal percutánea (ACTP) con colocación de "stents" en la enfermedad del tronco coronario izquierdo (TCI) y los comparamos con los enviados a cirugía de revascularización miocárdica (QX). Material y Métodos: De mayo de 1998 a octubre de 2003 se realizaron 3,680 procedimientos a 2,900 pacientes, se seleccionaron 30 pacientes, grupo GACTP; con colocación de stents en 17 protegidos y TCI no protegido, 13 inapropiados para cirugía por malos lechos y por rechazo del enfermo y grupo GRVM abordaje quirúrgico 30 pacientes, con promedio 3.2 puentes. Edades de 45 a 74 años (65.7 ± 11.5) para los de ACTP y para QX de 49 a 77 años (66.9 ± 7.1). Sexo masculino GACTP 25 (83%), GRVM 23 (76%), hipertensión arterial sistémica grupo 1 y 2: 10 (33%), tabaquismo grupo 1 y 2: 17 (56%), diabetes mellitus GACTP 11 (36%) GRVM tres (10%), hipercolesterolemia GACTP 19 (63%), GRVM 9 (30%), angina inestable según la Sociedad Canadiense de Cardiología (SCC) GACTP 17 (56%) GRVM 16 (53%) con enfermedad multivascular 20 (66%) ambos grupos. El porcentaje promedio de obstrucción fue de 90 ± 6.3%. La FE para el GACTP 30% a 55% 40.3 ± 8.7. GRVM 38% a 67% 48.6 ± 6.1. Resultados: El éxito inmediato para el GACTP 26 (87%) y GRVM 28 (90%). Complicaciones: GACTP 4 (13%) GRVM 20 (66%). IAM perioperatorio GAC-TP 2 (6%) GRVM 8 (26%). La mortalidad del GACTP cuatro (13%) y GRVM 3 (10%). El seguimiento GACTP de 19.4 meses y GRVM 20 ± 3, fue obtenido en 26 del total del grupo. Sobrevida tardía libre de eventos adversos mayores (MUERTE o IAM) GACTP 25 (83.3%), un paciente con IAM y para GRVM 20 (66.6%) un paciente falleció en el seguimiento. Conclusiones: La colocación de stents en enfermedad de TCI es un procedimiento factible como una alternativa de revascularización miocárdica, con bajo porcentaje de complicaciones, en casos con función ventricular conservada a pesar de su mayor perfil de riesgo.


Introduction: We analyzed the clinical and angiographic results, as well as the follow-up of patients with left coronary trunk disease (LCT) subjected to percutaneous transluminal coronary angioplasty (PTCA) with stenting and compared them with those subjected to myocardial revascularization surgery (MRV). Material and methods: From May 1998 to October 2003, 3,680 procedures were performed in 2,900 patients; 30 of them were selected to form group PTCA, 17 protected with stenting and 13 not protected, as they were not suited for surgery due to inappropriate bedding and rejection by the patient. Another group of 30 patients (MRV) with coronary bypass, average of 3.2 grafts. Age ranged from 45 to 74 years (65.7 ± 11.5) for the PTCA and for MRV from 49 to 77 years (66.9 ± 7.1); 25 men (83%) in the PTCA group and 23 men (76%) in the MRV group. Systemic arterial hypertension in both groups: 10 (33%), smoking in both groups: 17 (56%); diabetes mellitus PTCA: 11 (36%) and MRV: 3 (10%); hypercholesterolemia PTCA: 19 (63%), MRV 9 (30%); unstable angina according to the Canadian Society of Cardiology (CSC) for PTCA: 17 (56%), MRV; 16 (53%); multivascular disease in both groups: 20 (66%). Average percentage of obstruction was of 90 ± 6.3%. FE for PTCA, 30 to 55% (40.3 ± 8.7) and for MRV, 38 to 67% (48.6 ±6.1). Results: Immediate success in 26 patients (87%) for the PTCA group and in 28 patients (90%) forthe MRV group. Complications: PTCA, 4 (13%) and MRV, 20 (66%). Perioperative IAM for PTCA, 2 (6%) and for MRV, 8 (26%). Mortality in the PTCA group was of 4 patients (13%) and in the MRV group of 3 (10%). Follow-up for PTCA, 19.4 months, for MRV of 20 ± 3, obtained in 26 of the whole group. Late survival adverse events (DEATH or IAM): PTCA, 25 (83.3%), one patient with IAM; MRV, 20 (66.6%), one patient died during the follow-up period. Conclusions: Placement of stents in the left coronary trunk disease is a feasible procedure as an alternative for myocardial revascularization, with a low rate of complications in cases of conserved ventricular function despite their higher risk profile.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Angioplasty, Balloon, Coronary , Coronary Disease/therapy , Myocardial Revascularization , Stents , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Coronary Angiography , Coronary Disease/mortality , Coronary Disease/surgery , Data Interpretation, Statistical , Feasibility Studies , Follow-Up Studies , Fibrinolytic Agents/administration & dosage , Fibrinolytic Agents/therapeutic use , Myocardial Revascularization/mortality , Postoperative Complications , Retrospective Studies , Risk Factors , Stents/adverse effects , Thrombolytic Therapy , Time Factors , Treatment Outcome
4.
Arch. cardiol. Méx ; 75(3): 296-305, jul.-sep. 2005. tab
Article in Spanish | LILACS | ID: lil-631903

ABSTRACT

El objetivo es describir nuestra experiencia, resultados clínicos y angiográficos inmediatos en pacientes con IAM sometidos a angioplastía coronaria transluminal percutánea de rescate (ACTPR). Material y métodos: Tipo de estudio; retrospectivo, observacional, transversal y descriptivo con seguimiento a 30 días. De enero de 2001 a julio de 2004 se realizaron 3,238 procedimientos de ACTP con aplicación de stent a pacientes con diagnóstico de cardiopatía isquémica por aterosclerosis coronaria, se seleccionó a 32 pacientes que representan el 0.98%, con edad de 47 a 79 años promedio de 63, 24 (75%) del sexo masculino, con hipertensión arterial sistémica 29 (90.6%), diabetes mellitus 18 (56.3%), hipercolesterolemia 11 (34.4%), tabaquismo 24 (75%), con antecedentes de angina inestable 9 (28.1%) y con infarto miocardio previo 2 (6.3%). La localización del IAM: anterior extenso 14 (43.8%), anteroseptal en 6 (18.8%), postero-inferior en 5 (15.6%), Pl con extensión eléctrica y/o hemodinámica en VD en 4 (12.5%), lateral en 1 (3.1%). Se trombolizaron en un tiempo promedio 3.19 horas (rango 2-7) con estreptoquinasa 19 (59.4%) y con rTPA 13 (40.6%), la CPK-MB pico (U) promedio de 348 ± 240. Con Killip Kimball (KK) 1 en cinco (15.6%), II 16 (50%), III 5 (15.6%) y IV 6 (18.8%) éstos manejados con balón intraaórtico de contrapulsación. Resultados: Llevados a sala de hemodinamia en un tiempo de 6 a 24 h encontrando flujo TIMI 0 en 16 (50%), TIMI 1 en diez (31.2%), TIMI 2 en seis (18.8%), promedio de vasos enfermos de 1.9. Se implantó stent en 27 (84.3%). Éxito angiográfico post ACTP más stent TIMI 3 en 24 (75%). Complicaciones: En 9(28.1%), en 7 (21.8%) con no reflujo y en 1 (3.1%) disección de la arteria coronaria relacionada con el IAM, 6 (18.7%) que fallecieron, en 4 (12.5%) con choque cardiogénico; 3 (9.3%) la ACTPR fue fallida. Conclusión: La ACTPR es un procedimiento de alto riesgo y pese a ello es una buena alternativa de tratamiento en pacientes con trombólisis fallida.


The present study is aimed at describing the short-term assessment of clinical and angiographic results in patients with acute myocardial infarction treated with rescue percutaneous transluminal coronary angioplasty (RPTCA). Methods: We reviewed retrospectively, from January 2001 to July 2004, the interventional procedures performed in patients with coronary heart disease. From a total of 3,258 patients we selected 32 (0.98%) with acute myocardial infarction and failure of thrombolysis treatment, which were treated with RPTCA to relief the symptoms. Average age was 63 years (range 47-79), there were 24 men (75%); hypertension in 29 (90.6%); diabetes mellitus in 18 (56.3%); currently smoking 24 (75%); dyslipidemia in 11 (34.4%); unstable angina in 9 (28.1%); previous myocardial infarction in 2 (6.3%). The area related to the infarction was anterior and lateral in 14 (43.8%), anteroseptal in 6 (18.8%), postero-inferior in 5 (15.6%) with electric and hemodynamic involvement in 4 (12.5%), lateral in 1(3.1 %). Thrombolysis treatment was delivered in 3.19 hours (range 2-7 hours) with streptokinasein 19 (59.4%) and rTPA in 13 (40.6%). The evaluated serum marker was CPK-MB with the highest level of 348 ± 240 U/L. Killip Kimball (KK) class was established as follows: KKI in 5 (15.6%), II in 16 (50%), III in 5 (15.6%), and IV in 6 (18.8%). Patients with cardiogenic shock were treated with intra-aortic balloon counterpulsation. Results: Time between symptoms and arrival to the cath lab was 11 hours (range 6-24 hours). TIMI flow was: TIMI 0 in 16(50%). TIMI 1 in 10 (31.2%), TIMI 2 in 6 (18.8%). The number of vessels with a significant lesion was 1.9 (range 1-4). Stents were placed in 27 (84.3%) patients. Angiographic success post-angioplasty was achieved in 24 (75%); there were 9 complications (28.1%), no reflow in 7 (21.8%), coronary dissection in 1 (3.1%). Six patients died (18.7%) and 4 of them (12.5%) were in cardiogenic shock. Conclusion: RPT-CA is a high-risk procedure, being an acceptable treatment option for patients with thrombolysis failure.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Angioplasty, Balloon, Coronary , Fibrinolytic Agents/therapeutic use , Myocardial Infarction/therapy , Streptokinase/therapeutic use , Thrombolytic Therapy , Tissue Plasminogen Activator/therapeutic use , Angioplasty, Balloon, Coronary/mortality , Coronary Angiography , Counterpulsation/methods , Electrocardiography , Fibrinolytic Agents/administration & dosage , Myocardial Infarction/drug therapy , Retrospective Studies , Risk Factors , Stents , Shock, Cardiogenic/therapy , Streptokinase/administration & dosage , Time Factors , Treatment Outcome , Tissue Plasminogen Activator/administration & dosage
5.
Arch. cardiol. Méx ; 73(1): 18-23, ilus, tab
Article in Spanish | LILACS | ID: lil-773385

ABSTRACT

La valvuloplastía mitral con balón de Inoue se ha convertido en los últimos 15 años en el procedimiento intervencionista de elección en pacientes con estenosis mitral con valvas flexibles y no calcificadas. En este artículo nosotros reportamos la experiencia a largo plazo de 100 pacientes a quienes se les realizó este procedimiento en nuestro hospital (CMN 20 de Noviembre ISSSTE). El promedio de seguimiento fue de 38.72 ∓ 22.4 meses. Se logró éxito en el 83.3% de los pacientes. El área valvular mitral aumento de 0.95 ∓ 0.16 a 1.62 ∓ 0.24 cm² (P < 0.001) después del procedimiento y al final del seguimiento el área fue de 1.57 ∓ 0.29 cm². El gradiente trans-valvular medio disminuyo de 8.80 ∓ 3.67 mm Hg a 4.74 ∓ 1.90 mm Hg (P < 0.001). Se presentaron complicaciones en el 7.0% de los pacientes, la más frecuente fue la insuficiencia mitral debido a ruptura de una de las valvas. No hubo decesos. Conclusiones: La valvuloplastía mitral con balón es un procedimiento efectivo en pacientes con score de Wilkins ⋜ 8, con un mínimo riesgo de complicaciones y un resultado duradero a largo plazo, con el 90% de los pacientes en clase funcional I NYHA al final del seguimiento.


Balloon mitral valvuloplasty has, over the last 15 years, become an established interventional procedure for patients with pliable non-calcified mitral stenosis. In this article we describe the long-term outcome of 100 patients from our hospital (National Medical Center "20 de Noviembre" ISSSTE, Mexico City), who were treated with this procedure. Average follow-up was 38.72∓22.4 months. The procedure was successful in 83.3% of the patients. After the procedure, the average valvular area changed from 0.95∓0.16 to 1.62∓0.24 cm² (P < 0.001) and, at the end of the follow-up time, it was 1.57 ∓ 0.29. The trans-valvular mean gradient changed from 8.80∓3.67 mm Hg to 4.74∓1.90 mmHg (P ⋜ 0.001). Complications occurred in 7.0% of the patients, the most important one being acute mitral insufficiency due to valvular rupture. No deaths occurred. Conclusions: Balloon valvuloplasty is an effective method in patients with Wilkins score of 8 or less, with minimal risk of complications, and long lasting results. At the end of the follow-up time, patients were in NYAH functional class I. (Arch Cardiol Mex 2003; 73:18-23).


Subject(s)
Adult , Female , Humans , Male , Catheterization/methods , Mitral Valve Stenosis/surgery , Catheterization/adverse effects , Follow-Up Studies , Mexico , Postoperative Complications , Treatment Outcome
6.
Arch. cardiol. Méx ; 71(2): 151-159, abr.-jun. 2001. ilus, CD-ROM
Article in Spanish | LILACS | ID: lil-306492

ABSTRACT

La finalidad de la estimulación multisitio es corregir la sincronía eléctrica y mecánica atrial y ventricular que se presenta en pacientes con fibrilación atrial paroxística (FAP) y miocardiopatía dilatada. Reportamos los dos primeros casos, en México, con estimulación biatrial para el tratamiento de la FAP, a uno se le implantó marcapaso tricameral y al otro tetracameral. El primero era un hombre joven al cual se le realizó modificación de la conducción atrioventricular con radiofrecuencia para el control de la frecuencia ventricular durante la fibrilación atrial. El segundo caso era una mujer con transposición corregida de los grandes vasos y fracción de expulsión (FE) del 30 por ciento, el cual presentaba bloqueo atrioventricular completo. El modo de estimulación fue DDD para el primer paciente y DDDR para el segundo, con función nocturna y cambio automático de modo en ambos. Se estimularon ambas aurículas, en la orejuela derecha y la izquierda a través del seno coronario. Los episodios de FAP se presentaron solamente en el primero pero en menor número y duración. La FE y la clase funcional mejoraron en el paciente con sincronización atrial y ventricular. Concluimos que la estimulación biatrial es efectiva en el control de la FAP.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Atrial Fibrillation/therapy , Pacemaker, Artificial , Electric Stimulation Therapy/methods
7.
Arch. Inst. Cardiol. Méx ; 70(4): 391-8, jul.-ago. 2000. ilus
Article in Spanish | LILACS | ID: lil-280426

ABSTRACT

Reportamos el primer caso en México D.F de la inserción de un marcapaso tricameral endovenoso en un paciente de 40 años con miocardiopatía dilatada, ritmo cambiante y bradicardia grave. Se puncionó la subclavia derecha, se colocaron los tres electrodos con fijación activa en la aurícula derecha, en el tracto de salida del ventrículo derecho (ánodo) y en la gran vena cardíaca (cátodo). Los electrodos ventriculares se conectaron a un adaptador en "Y" y este a la vez a una fuente de marcapaso DDDR, se programó en forma bipolar. El paciente mejoró clínicamente en los primeros 8 días, su fracción de expulsión, por ventriculografía, pasó de 30 a 35 por ciento, y su clase funcional, por ergometría, pasó de IV a I. La estimulación multicameral, en estos pacientes, ha mejorado su función cardíaca, básicamente por la disminución de la regurgitación mitral y tricuspídea, por un mejor llenado ventricular y una mayor sincronía en la estimulación ventricular. La estimulación multicameral ha incrementado la complejidad en la programabilidad de los marcapasos por lo cual la codificación utilizada hasta el momento tendrá que modificarse. La letra utilizada en la primera y segunda posición en este tipo de marcapasos, deberá ser T (Three) o F (Four) en caso de ser tricameral o tetracameral y la T (trigger) que se utiliza en la tercera posición cambiaria a "t". Concluimos que la colocación de marcapaso tricameral es factible y lleva a la mejoría clínica a los pacientes con miocardiopatía dilatada y es necesario que se modifique la codificación actual en la estimulación cardíaca crónica.


Subject(s)
Humans , Male , Adult , Bradycardia/therapy , Cardiomyopathy, Dilated/therapy , Cardiac Pacing, Artificial/methods , Electrodes, Implanted , Pacemaker, Artificial , Polymyositis
8.
Arch. Inst. Cardiol. Méx ; 67(2): 101-5, mar.-abr. 1997. tab
Article in Spanish | LILACS | ID: lil-217287

ABSTRACT

De febrero de 1995 a febrero de 1997 se colocaron 157 stents a 105 pacientes. La edad varió de 38 a 81 años (media 58), 83 del sexo masculino y 22 del femenino. En 66 (62.8 por ciento) se colocó un solo stent y en 39 (37.2 por ciento), de 2 a 6. Se colocaron 83 Palmaz/Schatz (P/S), 27 ACT-ONE, 18 Wiktor, 9 Gianturco Rubin (GR), 8 Wallstent, 6 XT-BARD y 6 microstents. La indicación fue de novo en 23.8 por ciento, 87.5 por ciento post ACTP fallida y 13.3 por ciento postreestenosis de ACT. La implantación fue exitosa en el 96.1 por ciento de los casos. Los primeros 32 casos fueron manejados con anticoagulación oral, al resto sólo se les administró aspirina y ticlopidina únicamente. Las complicaciones fueron 4.7 por ciento de los enfermos con trombosis aguda y 0.9 por ciento subaguda, tres de ellos desarrollaron un IM (2.5 por ciento); 2.8 por ciento complicaciones vasculares, 0.9 por ciento se enviaron a cirugía de urgencia y en 2.8 por ciento hubo mortalidad. Durante el seguimiento de 1 a 18 meses (media 7.7), se han recateterizado 35 pacientes, de 2 a 14 meses (m=5.6), 12 de ellos con reestenosis. Durante la redilatación, en dos casos hubo disección del TCI y fueron redilatados con balón satisfactoriamente. Un enfermo tuvo estenosis del stent y progresión de la enfermedad en otros vasos, por lo que se envió a cirugía electiva, y un enfermo presentó evidencia de IM en la zona correspondiente al sitio del stent, se trombolizó y el recateterismo tres días después mostró una estenosis del 50 por ciento. Los otros enfermos se encuentran asintomáticos o con pruebas de esfuerzo negativas. Este estudio confirma los beneficios de esta nueva tecnología como otra alternativa muy prometedora de revascularización miocárdica percutánea. Falta seguimiento a largo plazo para conocer la incidencia real de reestenosis en cada uno de los diferentes tipos de stent


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Coronary Disease/surgery , Follow-Up Studies , Recurrence , Stents/adverse effects
9.
Arch. Inst. Cardiol. Méx ; 66(6): 467-75, nov.-dic. 1996. ilus
Article in Spanish | LILACS | ID: lil-187749

ABSTRACT

De febrero de 1995 a abril de 1996 se estudiaron 32 pacientes sometidos a angioplastía coronaria transluminal percutánea (ACTP), a quienes se les realizó ultrasonido intracoronario (UIC). Se encontró un 53 por ciento (n=17) placas excéntricas y 47 por ciento (n=15) concéntricas. El 59.3 por ciento (n=19) fueron suaves, duras o fibrocalcificadas el 21.8 por ciento (n=7) y calcificadas en 19 por ciento (n=6). Por eso, en más de 40 por ciento de placas existía algún grado de calcificación y la mayoría de ellas presentaron desición post ACTP. En el 25 por ciento (n=8) el UIC determinó la no intervención: 7 de ellos por lesiones no significativas en pacientes en control tardío post ACTP y en un caso por una lesión no susceptible de este procedimiento. De las 24 arterias restantes, los cambios morfológicos post ACTP fueron: el 41.6 por ciento tipo A, 12.5 por ciento tipo B, 45.8 por ciento tipo C, 8.3 por ciento tipo D; 90.9 por ciento tipo E1 y 9.1 por ciento tipo E2. La disección post ACTP se presentó en el 54.1 por ciento de los casos. Con base en dichas observaciones, nuevas dilataciones o stents fueron indicados. Dos casos con síndromes coronarios agudos mostraron placas suaves y fibrosas que respondieron satisfactoriamente a la dilatación. El porcentaje de obstrucción residual post ACTP fue de 23.7 por ciento por angiografía cuantitativa y 52.4 por ciento por UIC. Complicaciones: tres sujetos presentaron espasmo coronario, que revirtió satisfactoriamente a la administración de BTG. En conclusión el UIC puede ser de ayuda en la evaluación de los resultados post ACTP, identifica sus complicaciones, norma la conducta a seguir y en algunos casos optimiza los resultados a pesar de una imagen adecuada por AC


Subject(s)
Humans , Angioplasty, Balloon, Coronary/methods , Coronary Vessels , Ultrasonics
10.
Arch. Inst. Cardiol. Méx ; 66(4): 313-21, jul.-ago. 1996. ilus
Article in Spanish | LILACS | ID: lil-184042

ABSTRACT

De febrero de 1995 a febrero de 1996 se estudiaron 52 pacientes con ultrasonido intravascular (UIV); tres con coartación aórtica (CoAo), 1 con persistencia del conducto arterioso (PCA), 5 con cardiopatía reumática inactiva (CRI) y arterias coronarias normales por angiografía convencional (AC), 1 con puente muscular en la descendente anterior, 20 sometidos a angioplastía transluminal percutánea (ACTP), (grupo I); uno de ellos postirradiación con laser exímero y 22 con implante de malla endovascular (MEV) Grupo II. En CoAo el UIV permitió observar las características del tejido causante de la coartación y los mecanismos de dilatación. En el caso de PCA fue posible medir con exactitud el diámetro del conducto arterioso. En los pacientes con CRI se observó enfermedad incipiente no detectada por AC. En el grupo I observamos placas suaves (n=8), mixtas(n=7), con calcio superficial (n=5), concéntricas (n=6) y excéntricas (n=14). Diez tuvieron evidencia de fractura o disección de la placa, algunos con pequeños fragmentos de íntima hacia el lumen vascular. En los últimos casos el UIV se utilizó para optimizar los resultados de la ACTP o definir el procedimiento. En el paciente con irradiación con laser el UIV demostró una luz irregular y lumen muy disminuido por lo que se completó con ACTP. En todos los pacientes del grupo II el UIV optimizó la colocación del dispositivo. No se presentó trombosis subaguda en ningún caso. Dentro de las complicaciones, sólo 4 sujetos presentaron angina y cambios ECG de isquemia durante el procedimiento, que revirtieron al retirar el catéter y aplicar nitroglicerina intracoronaria. En conclusión, el UIV permite conocer los mecanismos de obstrucción sus complicaciones y mejorar los resultados de la dilatación percutánea de las arterias coronarias. Detecta en forma muy incipiente el desarrollo es enfermedad coronaria no detecada por AC. optimiza la colocación de MEV. Permite seleccionar el dispositivo de revascularización y en ocasiones evitar o definir el procedimiento. La utilidad en otras patologías aún es limitado. Es un procedimiento seguro con mínima morbilidad y prácticamente nula mortalidad


Subject(s)
Humans , Male , Adult , Rheumatic Heart Disease/diagnosis , Rheumatic Heart Disease , Heart Defects, Congenital , Aortic Coarctation/diagnosis , Aortic Coarctation , Coronary Disease , Ductus Arteriosus, Patent , Ductus Arteriosus, Patent/diagnosis , Ultrasonography, Interventional
SELECTION OF CITATIONS
SEARCH DETAIL