Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
1.
J. health sci. (Londrina) ; 21(2): https://seer.pgsskroton.com/index.php/JHealthSci/article/view/6703, 19/06/2019.
Article in English | LILACS-Express | LILACS | ID: biblio-1051260

ABSTRACT

The objective of this study was to investigate the reproducibility of the International System for the Detection and Evaluation of Caries (ICDAS) for the diagnosis of caries by students of the Master's Degree in Dentistry (n = 25). The occlusal surfaces of human third molars (n = 14) were evaluated by twenty-five (n = 25) students using the ICDAS index and later a questionnaire was applied on demographic and professional context data. The dental crowns were sectioned in mesial to distal direction to obtain slices of 1mm in thickness which were observed in a stereomicroscope (40X) to identify the greatest extension of caries lesion. Data were analyzed by the Chi-Square, Fisher's Exact and Spearman's Correlation Coefficient at a significance level of 5%. There was an influence in the diagnosis of caries among students and teeth, where the majority of those who declared themselves to be safe missed the diagnosis. There was variability between the diagnosis and the proposed treatment for caries, with a better diagnosis for tooth VII and less for X; greater fit for treatment of teeth XIII, XIV and lower for IV, VI. The histological cut showed that the teeth were more affected by caries than the ICDAS. It was concluded that the ICDAS reproducibility was partially satisfactory when the occlusal surface was evaluated by the master's degree students. (AU).


Este trabalho teve o objetivo de investigar a reprodutibilidade do Sistema Internacional de Detecção e Avaliação de Cárie (ICDAS) para o diagnóstico da cárie, por estudantes de curso de Mestrado em Odontologia (n=25). As superfícies oclusais de terceiros molares humanos (n=14) foram avaliadas por vinte e cinco (n=25) estudantes, utilizando o índice ICDAS, e posteriormente foi aplicado questionário sobre dados demográficos e de contexto profissional. As coroas dentárias foram seccionadas no sentido mésio distal para obter fatias de 1 mm de espessura, que foram observadas em estereomicroscópio (40X) para identificar a maior extensão da lesão de cárie. Os dados foram analisados pelos Testes Qui-Quadrado, Exato de Fisher e Coeficiente de Correlação de Spearman, em nível de significância de 5%. Houve influência do grau de instrução dos estudantes no diagnóstico da cárie em relação ao dente avaliado e a maioria que se declarou segura errou o diagnóstico. Houve variabilidade entre o diagnóstico e o tratamento proposto para a cárie, com maior acerto para diagnóstico do dente VII e menor para o X; maior acerto para tratamento dos dentes XIII, XIV e menor para IV, VI. O corte histológico mostrou que os dentes estavam mais comprometidos pela cárie que o ICDAS. Concluiu-se que a reprodutibilidade do ICDAS foi satisfatória quando a superfície oclusal foi avaliada pelos mestrandos. (AU).

2.
RSBO (Impr.) ; 12(1): 61-67, Jan.-Mar. 2015.
Article in English | LILACS | ID: lil-782786

ABSTRACT

Introduction:Stone casts are used in dentistry to allow the confection of indirect restorations. Thus, gypsum dimensional stability is fundamental in order to achieve a precise fit between dental structure and restorative material.Objective: The purpose of the present study was to evaluate the hygroscopic linear expansion of commercially available gypsum products. Material and methods: Fifteen dental stones were analyzed (4 type II, 5 type III, 4 type IV and 2 type V), with n = 5. One hundred grams of each gypsum product were mixed following the respective manufacturers' recommendations for powder/water ratio and poured into a V-shape mold, connected to an expansion-measuring device. The hygroscopic expansion was evaluated during 120 min and the collected data was converted into percentage and compared to initial dimensions of the specimen. Results: All type II and V dental stones showed expansion values compatible to the ADA and ISO recommendations. Considering type III stones, only Rutenium 3 was compatible with the recommendations. For type IV, only Durone IV showed expansion values higher than that recommended by ADA, but lower than that of ISO recommendations.Conclusion: The hygroscopic linear expansion of gypsum products should be periodically controlled in order to ensure their precision and reliability to dental practice.

3.
RSBO (Impr.) ; 8(3): 287-293, Jul.-Sep. 2011. ilus, tab
Article in English | LILACS | ID: lil-720316

ABSTRACT

Introduction and objective: Glass ionomer cement, which was first introduced in Dentistry in 1972, presents good qualities such as aesthetics, fluoride release and adhesion to dental tissues. Because of its preventive characteristics regarding to dental caries, glass ionomer cement has been used for Atraumatic Restorative Treatment (ART), as reported by Frencken and Holmgren 6, meeting the principles announced by the World Health Organization (WHO) for application to large population groups without regular access to dental care. Material and methods: In this present study, the abrasive wear strength of two glass-ionomer cements (Vidrion R® and ChemFlex®) was evaluated through toothbrushing machine. Classic® toothbrushes with soft bristles and Sorriso® dentifrice were also used for the study. Results: Student-t test showed significant difference between both groups, with tobs value = 9.4411 at p < 0.05. Conclusion: It can be concluded that the wear rate caused by toothbrush/dentifrice was higher for Vidrion R® (52.00 mg) than ChemFlex® (5.57 mg).

4.
Rev. dental press estét ; 8(2): 89-95, abr.-jun. 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-594771

ABSTRACT

O objetivo deste trabalho é apresentar a resolução estética do caso clínico de um paciente com dentes escuros e manchas de fluorose, em que foi realizado o clareamento dentário em consultório, associado à microabrasão do esmalte. O clareamento foi efetuado nos dentes de ambas as arcadas, exceto nos molares. Após condicionamento do esmalte, o agente clareador à base de peróxido de hidrogênio a 35 por cento (Lase Peroxide Sensy, DMC Equipamentos Ltda.) foi aplicado e ativado duas vezes de 3 minutos com aparelho de luz híbrida de LED/laser de diodo terapêutico (Whitening Lase II, DMC Equipamentos Ltda.). Esse processo foi repetido cinco vezes, na mesma sessão, seguido de polimento, laserterapia e aplicação do gel dessensibilizante por 4 minutos. Em uma segunda sessão de clareamento, os caninos e pré-molares receberam mais duas aplicações do gel clareador ativado com luz híbrida. Ao final do procedimento, o paciente ainda apresentava manchas brancas nos dentes superiores, sendo realizada, no final da sessão, a microabrasão do esmalte. Ao final do tratamento, pode-se constatar resultado estético satisfatório alcançado por meio do clareamento dos dentes e remoção das manchas hipocalcificadas.


The objective of this paper was to present the esthetics resolution of a clinical case of a patient with discolored teeth and fluorosis which performed in-office tooth whitening plus enamel microabrasion. Bleaching was done in the teeth of both arches, except the molars. After etching enamel with phosphoric acid at 37% for 15 seconds, the whitening agent with 35% of hydrogen peroxide (Lase Peroxide Sensy, DMC Equipamentos Ltda) was applied twice and activated for three minutes with a hybrid LED/Laser light appliance (Whitening Lase II, DMC Equipamentos Ltda). This process was repeated five times in the same session, followed by polishing, laser therapy and application of desensitizing gel for 4 minutes. In a second session of bleaching, canines and premolars received two more applications of the whitening gel activated with hybrid light. At the end of the procedure, the patient still had white spots on the upper teeth, being held at the end of the session, the microabrasion of the enamel. At the end of treatment, one can see satisfactory final result achieved by means of teeth whitening and removal of hipocalcified stains


Subject(s)
Humans , Male , Young Adult , Bleaching Agents , Enamel Microabrasion , Esthetics , Hydrogen Peroxide , Esthetics, Dental
5.
Innov. implant. j., biomater. esthet. (Impr.) ; 5(3): 13-18, set.-dez. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-588541

ABSTRACT

Neste trabalho de resistência à tração foi avaliada a eficiência de 4 agentes cimentantes (fosfato de zinco S. S. White, ionômero de vidro Ketac Cem Easymix, resina composta/ionômero de vidro RelyX Luting 2 e resina acrílica especial Panavia 21 TC) usados para fixar coroas totais de NiCr a munhões tronco-cônicos, usinados em liga de Ti-6Al-4V. Foram utilizados 40 munhões, distribuídos em grupos de 10, para cada material. Os ensaios mecânicos foram realizados em uma máquina universal MTS 810, na velocidade de 0,5 mm/min. A respectiva Análise de Variância (ANOVA) apontou existir diferença significante entre os grupos e o teste de Tukey (p < 0,05) também mostrou diferenças significantes entre eles, exceto nas comparações fosfato versus RelyX e fosfato versus Ketac Cem. O melhor desempenho foi apresentado pela resina Panavia 21 (1.127,996 N); a resina composta/ionômero de vidro RelyX (478,197 N) mostrou comportamento similar apenas ao do fosfato (430,662 N), o qual apresentou desempenho semelhante ao ionômero de vidro Ketac Cem (227,705 N).


In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukeyïs test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N).


Subject(s)
Cementation , Dental Implants , Tensile Strength
6.
Innov. implant. j., biomater. esthet. (Impr.) ; 5(2): 35-39, maio-ago. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-581345

ABSTRACT

Por meio de tração, coroas totais de NiCr foram removidas de munhões pré-fabricados, compostos por uma liga de Ti6Al-4V. Num total de 20 munhões, 10 foram usados com sua superfície original e 10 com sua superfície modificada por laser, ambos cimentados com fosfato do zinco. O teste mecânico foi executado em uma máquina universal MTS 810 ajustada a uma velocidade de 0,5 mm/min. A análise estatística foi feita pelo teste de Levene, o qual mostrou homogeneidade de variâncias entre os grupos (F = 2,21; p < 0,1). O subsequente teste "t" de Student mostrou haver diferenças significantes entre os grupos. A modificação da superfície dos munhões através do laser causou um aumento na resistência à tração das coroas cimentadas com fosfato de zinco, de 430,66 para 1.514,87 N.


By means of tensile strength, NiCr total crowns were removed from machine-made conical abutments composed by an Ti-6Al-4V alloy. In a total of 20 abutments, 10 were used with it surface presenting high smoothness and 10 abutments had its surfaces modified by laser both cemented with zinc phosphate. The mechanical test was performed at a MTS 810 universal machine adjusted to a speed of 0.5 mm/m. The statistical analysis was done by Levene's test, which showed homogeneity of variances among groups (F =2.21; p < 0.1). "Student t test" showed that significant differences were found between groups. The modification of the abutment surface through laser caused an increase in pull-out resistance of crowns cemented with zinc phosphate from 430.66 N to 1.514,87 N.


Subject(s)
Cementation , Dental Implants , Tensile Strength
7.
Innov. implant. j., biomater. esthet. (Impr.) ; 4(2): 17-25, maio-ago. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-561080

ABSTRACT

O objetivo deste estudo foi avaliar a resistência ao desgaste de placas de titânio submetidos a um teste de escovação simulada. Os materiais empregados foram o titânio, esmalte bovino e resina acrílica termopolimerizável. Para o teste de abrasão, uma máquina de escovação simulada com escovas de cerdas macias, uma solução de dentifrício e água deionizada. Foram realizados 200.000 ciclos de escovação simulada. A perda de massa foi verificada através da diferença em porcentagem entre a massa inicial (antes da escovação) e massa final (após a escovação) através de uma balança analítica Sartorius. A alteração de rugosidade superficial foi determinada pela diferença em percentagem entre as médias de rugosidade inicial e final, após 5 leituras aleatórias por espécime realizado pelo rugosímetro Hommel Tester T 1000 antes e depois do teste de abrasão. A análise estatística demonstrou que todos os materiais do estudo apresentaram perda de massa e aumento significante de rugosidade. Todos os materiais apresentaram perda de massa em relação à pasta comercial. Entre as placas de titânio, apresentaram a menor perda de massa quando escovada pela pasta teste. Os blocos de esmalte apresentaram a maior alteração de massa com diferenças estatísticas quando comparado ao titânio. Quanto à rugosidade superficial, os blocos de esmalte se tornaram mais rugosos quando escovados pela pasta comercial, porém sem diferenças estatísticas entre si. A resina acrílica escovada pela marca comercial apresentou a maior alteração de rugosidade após o teste de escovação simulada.


The aim of this study was to evaluate the wear’s resistance of titanium plates after simulated brushing. We tested titanium plates, bovine enamel and thermo-activated acrylic resin. Soft bristles toothbrushes and a toothpaste slurry were used in an automated brushing machine, which performed 200,000 strokes. Weight loss was measured by the percent difference between initial (before brushing) and final (after brushing) specimens’ mass, using an analytical scale Sartorius. Surface roughness alterations were determined by the percent differences between initial and final roughness, which was obtained after 5 random readings/specimen by the profilometer Hommel Tester T1000, before and after the abrasion test. Statistical analyses revealed that all the materials tested presented a significant decrease in weight and increase in roughness. All the materials showed weight loss in relation to the commercial toothpaste. Titanium plates presented lower weight loss when brushed with the test toothpaste. Enamel blocks had significantly higher weight loss when compared to titanium plates. Regarding surface roughness, enamel blocks became more rough when brushed with the commercial toothpaste, but this was not statistically significant. Acrylic resin brushed with the commercial toothpaste also showed higher alterations in surface roughness after toothbrushing.


Subject(s)
Dental Implants , Titanium , Toothbrushing
8.
Rev. dental press estét ; 6(2): 42-51, abr. -jun.2009. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-543721

ABSTRACT

Este caso clínico avaliou o efeito do condicionamento prévio do esmalte com ácido fosfórico a 37%, na clareação em consultório realizada com gel de peróxido de hidrogênio a 35% e ativado com fonte de luz híbrida (led + laser terapêutico), em função da efetividade, tempo de tratamento e grau de mudança de cor. Após avaliação inicial, exame clínico e profilaxia supragengival completa, a cor foi avaliada visualmente com escala VITA Bleachedguide 3D-MASTER (VITA), quantitativamente com espectrofotômetro VITA Easyshade (VITA) e foi realizada a documentação fotográfica digital (Nikon D70s). Para efeito de comprovação, apenas os hemiarcos do lado direito receberam o condicionamento ácido prévio por 15 segundos. O gel clareador foi manipulado e aplicado sobre os dentes e, após 1 minuto, o gel foi ativado com luz híbrida durante 3 minutos. Após 1 minuto, nova ativação com luz por mais 3 minutos foi realizada. A princípio, 4 aplicações do gel foram realizadas, mas, ao final dessas, pôde-se observar que o grau de mudança de cor dos dentes nos hemiarcos do lado direito era maior que do lado esquerdo. Uma quinta aplicação foi realizada somente nos hemiarcos superior e inferior esquerdos. Pôde-se observar no hemiarco direito, no qual se realizou o ataque ácido, uma redução do número de aplicações do gel clareador. O paciente não relatou sensibilidade durante e após a clareação (24 horas e 1 semana). Após 1 semana, pôde-se verificar a efetividade da técnica em consultório empregada, além da efetividade do condicionamento ácido prévio na aceleração do procedimento clareador.


Subject(s)
Humans , Male , Adult , Tooth Bleaching/methods , Dental Enamel , Hydrogen Peroxide , Color , Esthetics, Dental , Dental Polishing/methods , Smiling
9.
J. appl. oral sci ; 16(2): 111-115, Mar.-Apr. 2008. ilus, tab
Article in English | LILACS | ID: lil-479755

ABSTRACT

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.


Subject(s)
Humans , Dental Prosthesis, Implant-Supported , Denture Design , Denture, Partial, Temporary , Dental Materials/chemistry , Glass/chemistry , Nylons/chemistry , Acrylic Resins/chemistry , Crowns , Dental Abutments , Dental Restoration Failure , Materials Testing , Pliability , Pressure , Polymers/chemistry , Stress, Mechanical , Surface Properties
10.
Rev. bras. eng. biomed ; 24(1): 17-22, abr. 2008. ilus, graf
Article in English | LILACS | ID: lil-510116

ABSTRACT

Este trabalho tem por finalidade avaliar a resistência abrasiva de 3 diferentes marcas de cimento de ionômero de vidro (CIV) restauradores, do tipo convencional, disponíveis no mercado nacional. Para isso foi utilizado o teste de agressividade, onde um disco dinâmico revestido com porcelana desgasta, em condições adequadamente estabelecidas, um disco estático revestido com o material restaurador estudado. Neste método valores menones de agressividade indicam maior resistência ao desgaste abrasivo. Foram confeccionados 24 corpos de provas, sendo 8 para cada marca. As marcas de CIV avaliadas foram: Vidrion R (fabricado pela empresa brasileira SSWhite), Ketac Fil Plus (fabricado pela empresa americana 3M ESPE) e Fuji IX GP (fabricado pela empresa japonesa GC), que posteriormente foi substituído pela marca Vitro Fill (fabricado pela empresa brasileira DFL Indústria e Comércio Ltda.). Os materiais foram confeccionados de acordo com as instruções dos respectivosfabricantes. Os testes foram executados em duas etapas: na primeira não houve controle do tempo de exposição ao ambiente, e as análises dos dados revelaram grande influência desta exposição na propriedade de resistência ao desgaste abrasivo. Em uma segunda etapa, o tempo de exposição foi rigidamente controlado, assim como a umidade do ar e a temperatura ambiente, desde a confecçãodos corpos de prova até a finalização dos ensaios, otendo-se assim os resultados desejados. Deste modo, além da classificação de cada marca de acordo com a resistência ao desgaste abrasivo, também foi mostrado que o tempo de exposição deste material ao ar ambiente deve receber atenção especial em trabalhos que versem sobre propriedades mecânicas do cimento de ionômero de vidro.


An evaluation was made of the abrasive strenght of three different brands of conventional glass ionomer cement (GIC) for dental restoration available on the Brazilian market. The evaluation was based on an agressiveness assay in which, under pre established conditions, a disk coated with porcelain wears down a static disk coated with the restorative material under study. According to this method, low agressiveness values indicate high abrasive wear resistance...


Subject(s)
Tooth Abrasion/chemically induced , Glass Ionomer Cements/analysis , Dental Cements , Dental Materials/analysis , Acrylic Resins/analysis
11.
J. appl. oral sci ; 16(2): 111-115, Mar.-Apr. 2008. ilus, tab
Article in English | LILACS, BBO | ID: biblio-873411

ABSTRACT

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey’s test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.


Subject(s)
Acrylic Resins , Dental Prosthesis, Implant-Supported , Dental Restoration, Temporary , Dental Materials , Materials Testing
12.
J. appl. oral sci ; 16(1): 7-11, Jan.-Feb. 2008. ilus, tab
Article in English | LILACS | ID: lil-472682

ABSTRACT

The purpose of this study was to evaluate the accuracy of the respective dies after polyether elastomeric procedure in the presence or absence of cervical contact of the acrylic resin shell with the cervical region, establishing a comparison to dies obtained with stock trays. This study consisted of three groups with 10 specimens each: 1) acrylic copings without cervical contact, (cn); 2) acrylic copings with cervical contact (cc); 3) perforated stock tray, (st). The accuracy of the resulting dies was verified with the aid of a master crown, precisely fit to the master steel die. ANOVA test found statistically significant differences among groups (p<0.001). Tukey's test found that the smallest discrepancy occurred in group cn, followed by cc, while the st group presented the highest difference (cc x cn: p=0.007; st x cn: p<0.001; st x cc: p<0.001).


Subject(s)
Humans , Acrylic Resins/chemistry , Crowns , Calcium Sulfate/chemistry , Dental Abutments , Models, Dental , Dental Prosthesis Design , Denture Rebasing , Dental Impression Materials/chemistry , Dental Materials/chemistry , Elastomers/chemistry , Chromium Alloys/chemistry , Dental Impression Technique/instrumentation , Materials Testing , Methylmethacrylates/chemistry , Resins, Synthetic/chemistry , Surface Properties , Stainless Steel/chemistry , Tooth Preparation, Prosthodontic/classification
13.
Rev. dental press estét ; 4(4): 39-49, out.-dez. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-529378

ABSTRACT

A procura por tratamentos estéticos, em casos de desgaste dentário patológico, tem aumentado devido à conscientização da sociedade sobre a importância da saúde e da estética. Esta é uma doença multifatorial que afeta o sistema estomatognático funcional e esteticamente. Sua ocorrência é cada vez mais presente na clínica diária. Com a evolução dos materiais odontológicos de inserção direta, tratamentos restauradores mais conservadores tornaram-se possíveis com o uso de resinas compostas. O tratamento demanda do profissional enfoque à doença oclusal em sua totalidade, o diagnóstico e a avaliação da extensão dos danos. Desta forma, este trabalho apresenta uma possibilidade de tratamento do desgaste dentário através de uma técnica restauradora adesiva direta, associada a uma técnica de ajuste oclusal.


Subject(s)
Humans , Male , Composite Resins , Dental Restoration Wear , Dental Restoration, Permanent/methods , Esthetics, Dental , Mouth Rehabilitation , Occlusal Adjustment
14.
RPG rev. pos-grad ; 14(1): 45-51, jan.-mar. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-529445

ABSTRACT

O cimento de ionômero de vidro, material freqüentemente utilizado na Odontologia devido à sua propriedade anticariogênica, tem aplicação especial na Saúde Pública, no denominado Tratamento Restaurador Atraumático. Neste trabalho, foi avaliada a resistência ao desgaste abrasivo, promovido por meio de uma máquina de escovação, de dois cimentos de ionômero de vidro, o Vidrion R e o ChemFlex™, dos quais o primeiro é nacional e tem menor custo. Os cremes dentifrícios utilizados foram o Baby Barney™ e o Tandy, ambos indicados para crianças por seu fabricante brasileiro. As escovas dentais, consideradas infantis, eram do modelo Classic, com cerdas macias, do mesmo fabricante dos dentifrícios. A análise de variância e o subseqüente teste deTukey aplicados aos valores obtidos permitiram constatar a existência de diferenças estatisticamente significantes, (1) com o ChemFlex™ tendo sofrido desgaste semelhante quando escovado com qualquer dos dois dentifrícios, enquanto o Vidrion R apresentou desgaste maior quando escovado com Tandy, e (2) com o dentifrício Baby Barney™ tendo desgastado de forma semelhante ambos os ionômeros analisados, enquanto o Tandy desgastou mais o Vidrion R.


Subject(s)
Dentifrices , Glass Ionomer Cements , Public Health , Analysis of Variance , Toothbrushing/methods , Mouthwashes , Tooth Abrasion
15.
Rev. Salusvita (Online) ; 25(3): 25-41, 2006.
Article in Portuguese | LILACS | ID: lil-558477

ABSTRACT

O presente trabalho teve como objetivo avaliar a fidelidade mor-fodimensional de troquéis confeccionados com dois gessos tipo IV (Vel-Mix® e Durone®), através do uso de um dispositivo constituído de uma coroa metálica usinada que se adapta com alta precisão a um troquel-padrão original, que simulava um dente preparado para receber uma coroa total. Os troquéis foram obtidos a partir de moldes de dois elastômeros (a silicona de adição Express® e a silicona de condensação Zetaplus / Orawash®), usando-se as técnicas de dupla moldagem e de casquete, cuja polimerização ocorreu com material imerso em água a 37°C. Em ambas as técnicas, a espessura da pasta fluida foi de 0, 2mm. A verificação do grau de adaptação da coroa-padrão aos troquéis foi realizada com auxílio do microscópio de profundidade. De acordo com a análise estatística realizada, conclui-se que: 1) os diferentes tipos de gessos não exerceram influência significante na alteração dimensional; 2) para o material Zetaplus / Oranwash, a técnica do casquete ofereceu menores distorções; 3) para o material, Express, a técnica da dupla-moldagem teve um melhor comportamento que a de casquete; 4) não houve diferença estatisticamente significante entre os dois materiais de moldagem em combinação com as respectivas técnicas de moldagem citadas anteriormente.


The present work aimed to evaluates the morfo-dimensional fidelity of die stones made with two type IV gypsum (Vel-Mix and Durone), with the aid of a customized device comprised of a usinat-ed metallic crown that adapts with high precision to an original die, simulating this device a prepared tooth to receive a full crown. The die stones were obtained from molds of two silicone impression materials (one polyvinylsiloxane, Express, and one condensation silicone, Zetaplus / Orawash). Impressions were obtained by either the putty-wash technique or by a single tooth acrylic tray. The impression materials were allowed to set in water at 37°C. In both techniques, the thickness of the flowing paste was of 0.2 mm. Adaptation was verificaded from the respective die stone obtained from impression with the use of a depth microscope. After proper statistical analysis, the following conclusion could be drawn: 1) no influence was observed decived from the different gypsum material; 2) for the material Zetaplus / Oranwash, the single tooth acrylic tray impression technique resulted in better adaptation; 3) for Express the putty-wash technique molding resulted in better adaptation; 4) there were no statistycally significant differences between the two impression materials associated with the both techniques conditions aforementioned.


Subject(s)
Silicone Elastomers , Materials Testing , Dental Impression Technique
16.
Rev. Fac. Odontol. Bauru ; 10(4): 215-223, out.-dez. 2002. tab
Article in Portuguese | LILACS, BBO | ID: lil-336126

ABSTRACT

A dureza é um dos importantes fatores a ser observado dentre as características dos materiais, sendo provavelmente indicativa de algumas outras propriedades mecânicas, inclusive para as resinas compostas. Foi analisada a dureza Rockwell 30T de 29 compósitos, confeccionando-se 3 corpos-de-prova para cada material. Após fotopolimerizaçäo por 80 segundos, aguardava-se mais 5 minutos e determinava-se a dureza (inicial); os espécimes eram entäo armazenados em água desionizada, a 37§C, durante 168 horas, quando nova leitura da dureza (final) era realizada. Estatisticamente, todas as resinas mostraram aumento de dureza, da mediçäo imediata para a com 168 horas; a resina Filtek Z-100 isoladamente apresentou o maior valor de dureza inicial; quando da dureza final, ela também apresentou o maior valor, agora acompanhada pela Filtek P-60; a de pior desempenho foi a Helioprogress, em ambas as idades


Subject(s)
Composite Resins , Hardness , Composite Resins , Dental Materials/classification , Dental Materials/chemistry
17.
RPG rev. pos-grad ; 7(1): 64-73, jan.-mar. 2000. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-298260

ABSTRACT

Foi utilizado um método inédito para a avaliaçäo do desempenho (tempo de vida útil) de pontas diamantadas, especialmente confeccionadas com 8 tipos de gräos (naturais e sintéticos), cortando-se substrato constituído por vidro, o qual era movimentado contra a ponta em açäo. Estabelecida uma série de necessárias condiçöes operatórias, os valores de tensäo e corrente elétrica no motor da caneta (a qual prendia a ponta em ensaio) eram basicamente transferidos para um microcomputador, onde em tempo real era calculado o valor da respectiva força tangencial de corte, através de um programa de computaçäo especialmente desenvolvido, o qual efetuava uma série de cálculos matemáticos, criando gráficos e mantendo o registro de todos os valores verificados. Nas condiçöes estabelecidas, em ordem decrescente de magnitude da vida útil, os gräos de diamante avaliados assim se comportaram: PDA 433, DMB-T, DMB-G, PDA 555, PDA 665, PDA 768, TED-II e PDA 878


Subject(s)
Diamond/analysis , Dental Instruments/standards , Diamond/chemistry , Diamond/classification , Computer Graphics/statistics & numerical data , Computer Graphics/instrumentation , Dental Materials/analysis , Dental Materials/classification , Dental Materials/chemistry , Mathematical Computing
18.
RPG rev. pos-grad ; 6(4): 338-45, out.-dez. 1999. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-298242

ABSTRACT

Este trabalho apresenta uma nova metodologia e um banco de ensaios para a avaliaçäo do desgaste de resinas compostas em laboratório, simulando-se o desgaste por erosäo mecânica de restauraçöes dentárias em pacientes, através da realizaçäo de testes padronizados assistidos por computador. O método proposto para a determinaçäo do desgaste de resinas compostas é baseado no estudo do comportamento da agressividade da superfície de restauraçöes dentárias de resina (capacidade de remover material) para com outras resinas, sendo que as resinas compostas testadas foram a Herculite© e a APH©. Através da metodologia empregada, verificou-se a maior resistência da resina APH© frente à Herculite©. Da análise estatística pode-se concluir que o método desenvolvido apresenta valores reduzidos de variabilidade. Como aplicaçäo prática, esse método possibilitará a avaliaçäo da resistência ao desgaste de vários tipos de materiais, podendo auxiliar em pesquisas, agilizando a avaliaçäo da resistência à abrasäo das resinas compostas


Subject(s)
Composite Resins , Dental Restoration Wear , Tooth Abrasion , Models, Theoretical
19.
Rev. Fac. Odontol. Bauru ; 7(3/4): 7-13, jul.-dez. 1999. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-298400

ABSTRACT

Avaliou-se a resistência à compressäo e à traçäo diametral de três materiais restauradores (DFL Alloy, liga de gálio Galloy e Velvalloy), associados ou näo a três sistemas adesivos (All-Bond 2, Paama-2 e Resinomer), nas idades de 1 e 48 horas, através de corpos-de-prova (cinco para cada condiçäo específica). Todas as fases deste trabalho foram executadas seguindo-se a Especificaçäo no. 1 da A.D.A. e pôde-se concluir que: 1) o aumento da idade fez elevar os níveis de resistência; 2) houve diferença estatisticamente significante entre os materiais, assim como para as condiçöes sem e com adesivo, quanto à resistência à compressäo e quanto à traçäo diametral; 3) nas duas situaçöes de ensaios realizadas, a liga Galloy comportou-se melhor, comparavelmente à liga Velvalloy, enquanto que a DFL Alloy apresentou os piores resultados


Subject(s)
Compressive Strength , Dental Materials/classification , Dental Materials/chemistry , Tensile Strength , Dentin-Bonding Agents/classification , Dentin-Bonding Agents/chemistry , Dental Amalgam/chemistry , Gallium/chemistry , Dental Alloys/classification , Dental Alloys/chemistry
20.
Rev. Fac. Odontol. Bauru ; 7(3/4): 33-7, jul.-dez. 1999. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-298404

ABSTRACT

A borracha vulcanizada descoberta por Charles Goodyear em 1839 teve grande utilizaçäo na confecçäo de bases de dentaduras até 1936, quando entäo apareceu a resina acrílica para preencher a lacuna estética, e assim alguns problemas foram resolvidos, outros ainda permaneceram como: ciclo incorreto, movimentaçäo dental, alteraçöes dimensionais, dentre outras, diante disto, verificou-se as possíveis alteraçöes dimensionais ocorridas com uma resina acrílica ativada termicamente após polimerizaçäo, por 3 diferentes técnicas, respectivamente denominadas 1) de Tuckfield, 2) de Laboratório, e 3) sob Pressäo. Para esta finalidade, foram construídas 10 muflas padräo, com 10 corpos de prova em cada técnica empregada, totalizando assim 30 corpos de prova padronizados. Apesar de ocorrerem alteraçöes dimensionais por contraçäo de polimerizaçäo entre todas as técnicas descritas, pelas análise estatística concluiu-se que: na aplicaçäo dos testes de Tukey a nível de 5 por cento, ocorreu diferença significante somente entre as técnicas T (de Tuckfield) e P (de Pressäo)


Subject(s)
Acrylic Resins/classification , Acrylic Resins/metabolism , Dental Materials/classification , Dental Materials/metabolism , Dental Materials/chemistry , Acrylic Resins/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL