J. appl. oral sci ; 20(1): 16-20, Jan.-Feb. 2012. ilus, tab
Article in English | LILACS | ID: lil-618147

ABSTRACT

The need to develop new dental luting agents in order to improve the success of treatments has greatly motivated research. OBJECTIVE: The aim of this study was to evaluate the diametral tensile strength (DTS) and film thickness (FT) of an experimental dental luting agent derived from castor oil (COP) with or without addition of different quantities of filler (calcium carbonate - CaCO3). MATERIAL AND METHODS: Eighty specimens were manufactured (DTS N=40; FT N=40) and divided into 4 groups: Pure COP; COP 10 percent; COP 50 percent and zinc phosphate (control). The cements were mixed according to the manufacturers' recommendations and submitted to the tests. The DTS test was performed in the MTS 810 testing machine (10 KN, 0.5 mm/min). For FT test, the cements were sandwiched between two glass plates (2 cm²) and a load of 15 kg was applied vertically on the top of the specimen for 10 min. The data were analyzed by means of one-way ANOVA and Tukey's test (α=0.05). RESULTS: The values of DTS (MPa) were: Pure COP- 10.94±1.30; COP 10 percent- 30.06±0.64; COP 50 percent- 29.87±0.27; zinc phosphate- 4.88±0.96. The values of FT (µm) were: Pure COP- 31.09±3.16; COP 10 percent- 17.05±4.83; COP 50 percent- 13.03±4.83; Zinc Phosphate- 20.00±0.12. One-way ANOVA showed statistically significant differences among the groups (DTS - p=1.01E-40; FT - p=2.4E-10). CONCLUSION: The experimental dental luting agent with 50 percent of filler showed the best diametral tensile strength and film thickness.


Subject(s)
Humans , Castor Oil/chemistry , Dental Cements/chemistry , Analysis of Variance , Calcium Carbonate/chemistry , Dental Materials , Dental Stress Analysis , Materials Testing , Tensile Strength
2.
Rev. odontol. UNESP (Online) ; 40(4): 166-173, jul.-ago. 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-614423

ABSTRACT

Introdução: Atualmente, existem muitas dúvidas em relação aos métodos de limpeza de fresas, o que estimula o estudo desses métodos visando maior eficiência e menor prejuízo desses instrumentos rotatórios. Objetivo: Avaliar a influência de métodos de limpeza sobre a eficiência de corte e sobre as características morfológicas de fresas de açoinoxidável de carbeto de tungstênio (carbide). Material e método: Trinta fresas foram divididas em cinco grupos (n = 6), de acordo com o método de limpeza: L1- escova de aço; L2- escova de nylon; L3- ultrassom + água destilada; L4- ultrassom + solução desincrustante; L5- nenhum método de limpeza (controle). As fresas foram utilizadas para o corte de esmalte dental bovino durante seis períodos de 12 minutos cada. Após cada período, as fresas eram limpas (exceto L5) seguindo o protocolo estabelecido para cada grupo. A eficiência de corte foi determinada pelo método da perda de massa e as características morfológicas, por meio de análise fotomicrográfica. Resultado: As médias da quantidade de desgaste após 72 minutos de uso foram: L1 = 0,3558 g; L2 = 0,4275 g; L3 = 0,4652 g; L4 = 0,4396 g, e L5 = 0,4854 g. Houve diferença significante para o tempo de uso (p < 0,001) e o método de limpeza (p < 0,001). O grupo L1 apresentou pior desempenho. Independentemente do grupo experimental, a análise morfológica revelou alterações nas lâminas de corte a partir de 12 minutos, sendo o grupo L1 o mais afetado. Conclusão: O método mais prejudicial à eficiência de corte e que mais alterou as características morfológicas das fresas carbide foi a limpeza com escova de aço.


Introduction: Currently, there are many questions regarding the cleaning methods seeking greater efficiency and less loss of burs. Aim: the aim of this study was to evaluate the influence of cleaning methods on the cutting efficiency and morphological characteristics of stainless steel burs tungsten carbide (carbide). Materials and method: Thirty burs were divided into five groups (n = 5) according with the cleaning method: L1- steel brush, L2- nylon brush, L3- ultrasound + distilled water, L4- ultrasound + descaling solution and L5- no cleaning method (control). Theburs were used for the cutting of bovine enamel during six periods of 12 minutes each. After each period, the burs were cleaned (except L5) following the protocol established for each group. The cutting efficiency was determined by mass loss and morphological characteristics. Result: The average amount of wear after 72 minutes of use were L1 = 0.3558 g; L2 = 0.4275 g; L3 = 0.4652 g; L4 = 0.4396 g e L5 = 0.4854 g; significant differences in the time of use (p < 0.001) and cleaning method (p < 0.001). The L1 group showed the worst performance. Regardless of theexperimental group, morphological analysis revealed alterations in the cutting blades soon after the first 12 minutes, being L1 the most affected group. Conclusion: The cleaning with wire brush was the most damaging method to the cutting efficiency and to the morphology of carbide burs.


Subject(s)
Stainless Steel , Ultrasonics , Tungsten Compounds , Dental Instruments , Efficiency , Analysis of Variance , Statistics, Nonparametric
3.
Braz. j. oral sci ; 9(1): 39-42, Jan.-Mar. 2010. ilus, tab, graf
Article in English | LILACS, BBO | ID: lil-578045

ABSTRACT

Aim: In this study, a mass-loss method was used to verify whether bovine enamel has the same wear pattern as human enamel in cutting efficiency tests of diamond burs. Methods: Seventy-two teeth were used: 36 human molars (HT) and 36 bovine mandibular central incisors (BT). The enamel of the teeth was cut using diamond bur #1092 attached to a high-speed handpiece under controlled pressure (50-80 g). Each bur (n=12) cut for a total of 72 min, divided into 6 periods of12 min each (12-min, 24-min, 36-min, 48-min, 60-min, and 72-min). The amount of enamel removed was determined by the difference between pre- and post-cut tooth masses. Results:The mean amounts (g) of enamel removed were: HT- 12-min=0.11; 24-min=0.12; 36-min=0.11; 48-min=0.11; 60-min=0.10; 72-min=0.12; BT- 12-min=0.12; 24-min=0.15; 36-min=0.15; 48-min=0.13; 60-min=0.16; 72-min=0.14. Data were analyzed using ANOVA followed by Tukey’s test, and the results showed statistically significant differences between human and bovine teeth (p<0.001) and among the cutting periods (p<0.001).Conclusions: It was concluded that the cutting efficiency of the burs was different between the tested substrates, and that bovine enamel underwent greater mass loss than did human enamel.


Subject(s)
Humans , Animals , Cattle , Dental High-Speed Equipment , Diamond , Dental Enamel/ultrastructure , Dental Cavity Preparation/instrumentation , Dental High-Speed Technique/instrumentation , Analysis of Variance , Dental Instruments , Effectiveness , Time Factors , Tooth Abrasion
4.
J. appl. oral sci ; 17(6): 584-589, Nov.-Dec. 2009. ilus, graf, tab
Article in English | LILACS | ID: lil-534424

ABSTRACT

OBJECTIVE: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. MATERIAL AND METHODS: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. RESULTS: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 ± 0.0627 g; G2 = 0.2077 ± 0.0231 g; G3 = 0.1980 ± 0.0326 g; G4 = 0.1203 ± 0.0459 g; G5 = 0.2642 ± 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. CONCLUSION: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.


Subject(s)
Humans , Dental Instruments , Microwaves/therapeutic use , Sterilization/methods , Carbon/chemistry , Dental Disinfectants/therapeutic use , Equipment Design , Equipment Failure , Glass/chemistry , Glutaral/therapeutic use , Hot Temperature , Materials Testing , Surface Properties , Stainless Steel/chemistry , Time Factors
5.
ROBRAC ; 16(42): 1-6, dez. 2007.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-525061

ABSTRACT

O objetivo deste estudo foi avaliar a condição de higiene oral de pacientes usuários de próteses parciaisfixas (PPFs) por meio de um questionário e exame clínico. O questionário abordava o histórico das PPFse os metodos de higiene oral empregados, e o exame clínico, o tipo de material utilizado para confecçãodas PPFs, a localização da linha cervical (LC), o índice gengival (IG) e o índice de placa (IP). O IP e o IGforam avaliados nos dentes remanescentes (G1) e nos dentes pilares da prótese (G2) conforme critériosde Lõe; para esses índices foram adotadas as medianas para análise estatística, sendo aplicado o teste deQui-quadrado. Foram avaliados 50 pacientes portadores de 65 PPFs das quais 78,5% tinham até 5 anos deuso sendo em sua maioria metalocerâmicas (64,6%). Com relação aos métodos de higiene, 58% dos pacientesutilizavam escova macia; 62% escovavam seus dentes 3 vezes/dia; 66% dos pacientes não tiveramdificuldades para higienizar após a instalação da prótese apesar de 80% não terem recebido instruçõesde higiene oral; a maioria não foi informada sobre retornos periódicos. Não houve diferença estatística significanteentre G1 e G2 com relação ao IP diferentemente da comparação entre o IG dos dois grupos, commaior inflamação gengival no G2 (p=0,0021). Coroas com linha cervical intra-sulcular apresentaram melhorIP (p=0,001) e as subgengivais pior IG (p=0,002). Concluiu-se que os pacientes usuários de PPFs apresentaramdificuldade para higienizar a prótese, evidenciando a necessidade de reforço dos métodos de higieneoral nesta região.


The aim of this study was to evaluate the oral hygienepractices of patient with fixed partial dentures(FPDs) using a questionnaire and a clinical examination.Fifty patients wearers of 65 FPDs wereevaluated. Each patient was questioned about theFPDs historical and the oral hygiene practices. Atthe clinical examination the material type of theFPDs, location of crown margins, gingival index (GI)and plaque index (PI) were recorded. The periodontalparameters of the uncrowned teeth (G1) werecompared with the abutment teeth (G2) accordingto Lõe. For these indexes the medians were usedfor statistical analysis and qui-square test was applied.Of the prostheses, 78.5% were up to 5 yearsof use; and 64.6% were metallo-ceramics.Regarding the oral hygiene practices, 66% of thepatients did not have difficulties of hygiene afterthe prosthesis insertion, although 80% of them didnot get hygiene instructions. Most of them were notinformed about regular maintenance care. The PIdid not differ between the crowned teeth (G1) andabutment teeth (G2). However G2 had significantlygreater gingival inflammation than G1 (p=.001). Intra-sulcular retainer margins showed the better PI(p=.001) and the subgingival retainer margins presentedthe worse GI (p=.002). It was concluded thatthe FPDs wearers had difficulties in the prostheseshygiene, and these findings suggest the necessityof oral hygiene reinforcement.

6.
Ciênc. odontol. bras ; 7(4): 60-66, out.-dez. 2004. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-405723

ABSTRACT

Foi avaliado, por meio de fotomicrografias, o desgaste de pontas diamantadas utilizando-se dois tipos de dentes: humano e bovino. Para isso, foi realizado um estudo in vitro com 72 dentes, sendo 36 molares humanos e 36 incisivos centrais bovinos. Realizaram-se desgastes na superfície de esmalte dos dentes com pontas diamantadas da marca KG Sorensen n°1092 totalizando 12 minutos de desgaste por dente. As pontas foram limpas com escova de aço e água e analisadas e fotografadas em lupa estereoscópica a cada totalização de tempo (12 minutos) e retornaram aos experimentos anteriores até completarem 72 minutos de uso por ponta diamantada. As fotomicrografias foram analisadas por três profissionais especializados onde foram atribuídos escores de 0 a 2 conforme a característica de sua ponta ativa. Os dados foram tabulados em Excel 2000 e foi ajustada uma regressão linear. O resultado encontrado mostra que no dente bovino a regressão foi de Y=0,133333+0,036111X e no humano, Y=0,233333+0,038889X, o que indica uma diminuição 7% mais rápida do número de diamantes das pontas usadas nos dentes humanos em relação às usadas nos bovinos, e também que as pontas perderam efetividade de corte a partir dos 48 minutos de uso em dentes humanos e 60 minutos em bovinos. Concluiu-se que o desgaste das pontas diamantadas em dentes humanos ocorre com menor tempo de uso, e que os dentes humanos são diferentes dos dentes bovinos com relação à resistência ao desgaste.


Subject(s)
Humans , Animals , Male , Female , Cattle , Dental Enamel , Dental Instruments , In Vitro Techniques , Photomicrography
7.
Rev. odontol. UNESP ; 33(2): 87-93, abr.-jun. 2004. ilus
Article in Portuguese | LILACS, BBO | ID: lil-510858

ABSTRACT

O objetivo deste trabalho foi avaliar o grau de satisfação de pacientes portadores de próteses parciais fixas (PPFs) e os fatores mais influentes nessa avaliação. Elaborou-se um questionário abrangendo desde o histórico das próteses até fatores relacionados com a adaptação dopaciente, o qual foi aplicado a pacientes com próteses fixas atendidos na Faculdade de Odontologia de Araraquara - UNESP. As questões foram escoreadas, tabuladas em Excel 2000 e submetidas ao teste de Qui-quadrado. Foram entrevistados 69 pacientes, 51 do sexo feminino e 18 do masculino,totalizando 118 PPFs com média de 4 elementos. A maioria das próteses tinha até 5 anos de uso (74,58%), havendo predominância de metalocerâmicas (71,19%); 89 próteses (75,42%) nuncahaviam sido substituídas, e 65,52% das substituições tiveram motivos funcionais como razão. Cinco pacientes (7,25%) foram classificados como insatisfeitos, 14 (20,29%) parcialmente satisfeitos e 50 (72,46%) satisfeitos com suas próteses. Dentre os fatores analisados, apenas o tipo de material da prótese influenciou a satisfação (p = ,022602). Fatores estéticos (36,81%) e mecânicos (29,12%) foram os mais citados como insatisfatórios. Concluiu-se que os pacientes estavam satisfeitos com o tratamento, sendo as metalocerâmicas consideradas as mais satisfatórias e que fatores estéticos emecânicos foram os principais fatores que contribuíram para a não satisfação plena.


Subject(s)
Humans , Denture, Partial, Fixed , Mouth Rehabilitation , Patient Satisfaction