Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. colomb. ciencias quim. farm ; 49(2): 509-522, May-Aug. 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1144364

ABSTRACT

SUMMARY This study aimed to develop and validate a stability-indicating liquid chromatography method for the determination of tirofiban hydrochloride and two synthetic impurities (impurity A and impurity C). The method utilizes a RP-18 column (250 mm x 4.6 mm; 5 µm) with the PDA detector for quantitation. A mixture of triethylamine 0.1% (acidified to pH 5.5 with phosphoric acid) and acetonitrile was used as the mobile phase at a flow rate of 1 mL min-1 with gradient elution. The method presented satisfactory linearity, precision, accuracy and robustness, as well as low limits of detection and quantification, which demonstrate sensitivity in the determination of tirofiban and impurities A and C. It was selective for the determination of the drug and impurities analysed, without interference of the degradation products generated under forced conditions, demonstrating the stability-indicating capacity of the proposed method. Tirofiban showed to be practically stable to oxidative (30% H2O2 for 24 h) and thermal (75 °C for 24 h) conditions, but presented degradation to UVA light and acid hydrolysis, obeying the first order kinetics for both. In this way, it can be used as a stability-indicating method in the quality control of the raw material of tirofiban hydrochloride, as well as of the finished product. The obtained results demonstrate the importance of deepening the studies in this area, to guarantee the quality of commercialized pharmaceutical products.


RESUMO Este estudo teve como objetivo desenvolver e validar método indicativo da estabilidade por cromatografía líquida para determinação de cloridrato de tirofibana e duas impurezas de síntese (impureza A e impureza C). O método utilizou coluna de fase reversa RP-18 (250 mm x 4,6 mm; 5 µm) e detector PDA para quantificação. A fase móvel foi composta por uma mistura de trietilamina 0,1% (acidificada com ácido fosfórico para pH 5,5) e acetonitrila, à vazão de 1 mL/min, no modo gradiente. O método apresentou linearidade, precisão, exatidão, robustez, bem como baixos limites de detecção e quantificação, demonstrando sensibilidade na determinação da tirofibana e impurezas A e C. O método apresentou seletividade na determinação do fármaco e das impurezas, sem interferência dos produtos de degradação gerados na degradação forçada da tirofibana, demonstrando sua capacidade indicativa de estabilidade. O fármaco apresentou-se estável a oxidação (H2O2 30% por 24 h) e a degradação térmica (75 °C por 24 h), mas degradou frente à luz UVA e hidrolise ácida, obedecendo cinética de primeira ordem para ambas. Dessa forma, pode ser utilizado como um método indicativo de estabilidade no controle de qualidade da matéria -prima do cloridrato de tirofibana, bem como no produto acabado. Os resultados obtidos demonstram a importância de aprofundar os estudos na área, com intuito de garantir a qualidade dos produtos farmacêuticos comercializados.

2.
Braz. j. pharm. sci ; 51(1): 221-231, Jan-Mar/2015. tab, graf
Article in English | LILACS | ID: lil-751366

ABSTRACT

This study describes the development and evaluation of stability-indicating liquid chromatographic (LC) and UV spectrophotometric methods for the quantification of ciprofibrate (CPF) in tablets and capsules. Isocratic LC separation was achieved on a RP18 column using a mobile phase of o-phosphoric acid (0.1% v/v), adjusted to pH 3.0 with triethylamine (10% v/v) and acetonitrile (35:65 v/v), with a flow rate of 1.0 mL min-1. Detection was achieved with a photodiode array detector at 233 nm. For the spectrophotometric analysis, ethanol and water were used as the solvent and a wavelength of 233 nm was selected for the detection. The methods were validated according to International Conference on Harmonization (ICH) guidelines for validating analytical procedures. Statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were successfully applied to the CPF quality-control analysis of tablets and capsules.


Este estudo descreve o desenvolvimento e avaliação de método indicativo da estabilidade por cromatografia líquida (LC) e método por espectrofotometria UV para quantificação de ciprofibrato (CPF) em comprimidos e cápsulas. No método por cromatografia líquida as análises foram realizadas isocraticamente em coluna de fase reversa C18, utilizando fase móvel composta por ácido o-fosfórico (0.1% v/v) pH 3.0, ajustado com trietilamina (10% v/v), e acetonitrila (35:65 v/v), com fluxo de 1,0 mL min-1. A detecção foi realizada em detector de arranjo de diodos a 233 nm. Na análise espectrofotométrica, etanol e água foram utilizados como solventes e o comprimento de onda de 233 nm foi selecionado para a detecção do fármaco. Os métodos foram validados de acordo com as diretrizes do International Conference on Harmonization (ICH). A análise estatística não mostrou diferença significativa entre os resultados obtidos pelos dois métodos. Os métodos foram aplicados com sucesso para análises de controle de qualidade do ciprofibrato em comprimidos e cápsulas.


Subject(s)
Tablets/pharmacokinetics , Chromatography, Liquid/methods , Spectrophotometry, Ultraviolet/classification , Capsules/pharmacokinetics , /analysis , Drug Stability