Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Gut and Liver ; : 170-178, 2023.
Article in English | WPRIM | ID: wpr-966877

ABSTRACT

Background/Aims@#Bilateral endoscopic drainage with self-expanding metallic stent (SEMS) can be used to effectively manage hilar malignant biliary obstruction. However, the benefits of using a trisegment drainage method remain unknown. @*Methods@#This study retrospectively reviewed the data of 125 patients with Bismuth type IIIa or IV unresectable malignant strictures who underwent bilateral endoscopic drainage using SEMSs at four tertiary centers. The patients were divided into the bilateral and trisegment drainage groups for comparison. The primary endpoint was stent patency and the secondary endpoints were technical success, technical and clinical success of reintervention, and overall survival. @*Results@#The technical success rates of the bilateral and trisegment drainage groups were 95% (34/36) and 90% (80/89) (p=0.41), respectively, with median stent patency durations of 226 and 170 days (p=0.26), respectively. Although the technical success of reintervention was not significantly different between the two groups (p=0.51), the clinical success rate of reintrvention was significantly higher in the trisegment drainage group (73% [11/15] vs 96% [47/49], p=0.009). The median survival times were 324 and 323 days in the bilateral and trisegment drainage groups, respectively (p=0.72). Multivariate Cox hazards model revealed no stent patency-associated factor; however, chemotherapy was associated with longer survival. @*Conclusions@#Although no significant difference was noted with respect to stent patency, significantly higher clinical success rates were achieved with reintervention using the trisegment drainage method than using the bilateral drainage method alone.

2.
Gut and Liver ; : 652-658, 2020.
Article | WPRIM | ID: wpr-833190

ABSTRACT

Background/Aims@#Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA; EUS-FNA) allows for diagnostic tissue specimens from various regions to be analyzed. How-ever, diagnosing recurrent pancreaticobiliary cancer after surgery is sometimes difficult. We evaluated the efficacy of EUS-FNA in the diagnosis of local recurrence of pancreatico-biliary cancer and analyzed the factors associated with falsenegative results. @*Methods@#Fifty-one consecutive patients who underwent EUS-FNA due to suspected recurrence of pancreaticobiliary cancer after surgery in an academic cen-ter were retrospectively analyzed. The criteria for EUS-FNA were a resected margin or remnant pancreas mass, round swollen lymph node (≥10 mm in diameter), and soft-tissue enhancement around a major artery. Patients with suspected liver metastasis or malignant ascites were excluded. @*Results@#Thirty-nine of the 51 patients had pancreatic cancer; the remaining 12 had biliary cancer. The target sites for EUS-FNA were the soft tissue around a major artery (n=22, 43%), the resected margin or remnant pancreas (n=12, 24%), and the lymph nodes (n=17, 33%). The median size of the suspected recurrent lesions was 15 mm (range, 8 to 40 mm). The over-all sensitivity, specificity and accuracy of EUS-FNA for the diagnosis of recurrence was 84% (32/38), 100% (13/13), and 88% (45/51), respectively. FNA of the soft tissue around major arteries (odds ratio, 8.23; 95% confidence interval, 1.2 to 166.7; p=0.033) was significantly associated with a falsenegative diagnosis in the multivariate analysis. @*Conclusions@#EUS-FNA is useful for diagnosing recurrent cancer, even after pancreaticobiliary surgery. The diagnoses of recurrence at soft-tissue sites should be interpreted with caution.

3.
Clinical Endoscopy ; : 479-485, 2019.
Article in English | WPRIM | ID: wpr-763471

ABSTRACT

BACKGROUND/AIMS: This study aimed to examine the diagnostic ability of endoscopic ultrasonography (EUS) for major vascular invasion in pancreatic cancer and to evaluate the relationship between EUS findings and pathological distance. METHODS: In total, 57 consecutive patients who underwent EUS for pancreatic cancer before surgery were retrospectively reviewed. EUS image findings were divided into four types according to the relationship between the tumor and major vessel (types 1 and 2: invasion, types 3 and 4: non-invasion). We also compared the EUS findings and pathologically measured distances between the tumors and evaluated vessels. RESULTS: The sensitivity, specificity, and accuracy of EUS diagnosis for vascular invasion were 89%, 92%, and 91%, respectively, in the veins and 83%, 94%, and 93%, respectively, in the arteries. The pathologically evaluated distances of cases with type 2 EUS findings were significantly shorter than those of cases with type 3 EUS findings in both the major veins (median [interquartile range], 96 [0–742] µm vs. 2,833 [1,076–5,694] µm, p=0.012) and arteries (623 [0–854] µm vs. 3,097 [1,396–6,000] µm, p=0.0061). All cases with a distance of ≥1,000 µm between the tumors and main vessels were correctly diagnosed. CONCLUSIONS: Tumors at a distance ≥1,000 µm from the main vessels were correctly diagnosed by EUS.


Subject(s)
Humans , Arteries , Diagnosis , Endosonography , Pancreatic Neoplasms , Retrospective Studies , Sensitivity and Specificity , Veins
4.
Clinical Endoscopy ; : 334-339, 2019.
Article in English | WPRIM | ID: wpr-763456

ABSTRACT

BACKGROUND/AIMS: We applied a back light system (BLS) with a magnifying glass to improve the ability to assess the adequacy of specimen sampling using endosonography. We conducted this study to evaluate the efficacy of the BLS in sampling of specimens by endoscopic ultrasound-guided fine needle aspiration of solid pancreatic masses. METHODS: This was a prospective, randomized, crossover, single-center clinical trial. An endosonographer evaluated adequacy on gross visual inspection and identified whitish specimen sampling sites with and without the BLS according to a randomization sequence in the first and second passes with a 25-G needle. On cytological evaluation, the presence of well-defined pancreatic ductal epithelium was evaluated by a cytopathologist who was blinded to any clinical information. RESULTS: A total of 80 consecutive patients were eligible during the study period. Adequacy was observed for 52 specimens (65%) with the BLS and 54 (68%) without the BLS (p=0.88). In assessment of specimen adequacy on gross examination, only fair agreement was observed both with and without BLS (kappa score 0.40 and 0.29, respectively). CONCLUSIONS: The BLS did not influence the ability to identify specimen sampling sites or reliable assessment of specimen site adequacy using gross visual inspection.


Subject(s)
Humans , Biopsy, Fine-Needle , Cross-Over Studies , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Endosonography , Epithelium , Glass , Needles , Pancreatic Ducts , Pancreatic Neoplasms , Prospective Studies , Random Allocation
5.
Clinical Endoscopy ; : 373-376, 2019.
Article in English | WPRIM | ID: wpr-763449

ABSTRACT

Endoscopic ultrasound (EUS)-guided transgastric drainage has been performed as a less invasive procedure for pancreatic fistulas and intra-abdominal abscesses occurring after surgery in recent years. However, there are no reports of EUS-guided transgastric drainage of intra-abdominal abscesses following gastrectomy. This case report describes 2 patients who developed an intra-abdominal abscess following gastrectomy and underwent EUS-guided transgastric drainage. Both patients underwent laparoscopy-assisted distal gastrectomy with Billroth-I reconstruction for gastric cancer. The intra-abdominal abscesses were caused by postoperative pancreatic fistula that developed following gastrectomy. One patient underwent naso-cystic drainage and the other underwent only a needle puncture of the abscess cavity. EUS-guided drainage was performed safely and effectively, although 1 patient developed gastroduodenal anastomotic leakage related to this procedure. In summary, EUS-guided transgastric drainage is safe and technically feasible even in post-gastrectomy patients. However, it is necessary to be careful if this procedure is performed in the early period following gastrectomy.


Subject(s)
Humans , Abdominal Abscess , Abscess , Anastomotic Leak , Drainage , Gastrectomy , Needles , Pancreatic Fistula , Punctures , Stomach Neoplasms , Ultrasonography
6.
Gut and Liver ; : 306-311, 2017.
Article in English | WPRIM | ID: wpr-69987

ABSTRACT

A newly developed short double-balloon enteroscope with a working channel enlarged to a diameter of 3.2 mm is a novel innovation in stent placement for patients with surgically altered anatomies. Herein, we report three patients in whom this new scope contributed to an efficient technique and ideal treatment. In the first case, the double guidewire technique was efficient and effective for multiple stent placements. In the second case, covered self-expandable metal stent (SEMS) placement, which is the standard treatment for malignant biliary obstruction, could be performed in a technologically sound and safe manner. In the third case, SEMS placement was performed as palliative treatment for malignant afferent-loop obstruction; this procedure could be performed soundly and safely using the through-the-scope technique. The wider working channel of this new scope also facilitates a smoother accessory insertion and high suction performance, which reduces procedure time and stress on endoscopists. Furthermore, this new scope, which has advanced force transmission, adaptive bending, and a smaller turning radius, is expected to be highly successful in both diagnosis and therapy for various digestive diseases in patients with surgically altered anatomies.


Subject(s)
Humans , Cholangiopancreatography, Endoscopic Retrograde , Diagnosis , Double-Balloon Enteroscopy , Gastric Outlet Obstruction , Palliative Care , Radius , Stents , Suction
SELECTION OF CITATIONS
SEARCH DETAIL