Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Indian J Ophthalmol ; 2023 Aug; 71(8): 3064-3068
Article | IMSEAR | ID: sea-225181

ABSTRACT

Purpose: To profile vitreoretinal (VR) fellows?in?training from India exposed to the Eyesi surgical simulator, to identify potential barriers to voluntary use, and enumerate the most preferred tools and tasks before incorporating them into a formal skill?transfer curriculum. Methods: A questionnaire consisting of 22 questions was designed and circulated through an online portal (surveymonkey.com) to four different institutes of India having a VR surgical fellowship program and using a functional Eyesi (Haag–Streit) simulator. All fellows and trainees who were exposed to the simulator were eligible to participate, irrespective of time spent on the simulator and exposure to training steps on real patients. The responses collected were private and anonymous. Results: Of the 37 respondents, most (n = 25, 68%) considered surgical simulators to be the best training tool before operating on the human eye. A majority (n = 35, 94.5%) of participants spent <3 h per week on the simulator, which, most (n = 30, 81%) felt was not enough time. The main reasons for this underutilization were work?hour limitations (54.8%), lack of a structured training program (19.3%), or a dedicated supervisor (16.1%). Again, the majority (n = 33, 89%) of participants responded that VR surgical skills acquired during simulator training were transferrable to the operating room, which was reflected by their response (n = 31, 83.7%) that simulator?based training should be made mandatory before operating room exposure. Conclusion: This study gives an insight into the overall practice patterns and preferences in simulation training of surgical VR fellows?in?training across India. It indicates that the simulator is extremely helpful to fellows and if adopted, VR surgical simulators with organized, directed, and supervised sessions will considerably improve the surgical training experience.

2.
Indian J Ophthalmol ; 2022 Oct; 70(10): 3681-3686
Article | IMSEAR | ID: sea-224638

ABSTRACT

Some degenerations involving the peripheral retina can result in a rhegmatogenous retinal detachment. Currently, there are no clear guidelines for retinal screening and/or management of these peripheral retinal degenerations in patients with or without recent onset posterior vitreous detachment or in those prior to refractive surgery or intraocular procedures. This article aims to provide a set of recommendations for the screening and management of peripheral retinal degenerations based on a common consensus obtained from an expert panel of retinal specialists.

4.
Indian J Ophthalmol ; 2022 May; 70(5): 1767-1772
Article | IMSEAR | ID: sea-224318

ABSTRACT

Purpose: The coronavirus disease (COVID?19) pandemic continues to play havoc in our lives. During the first “ lockdown” in 2020, we were keen on assessing the anxiety levels of patients who sought ophthalmic care despite the lockdown. Public health actions, such as social distancing, were necessary to reduce the spread of COVID?19. As a result, most people felt isolated and lonely, thereby causing increased levels of stress and anxiety in them. We aimed to assess the anxiety levels using the Hamilton Anxiety Scale and personality assessment using the 57?point Eysenck’s Personality Inventory (EPI) questionnaire among patients visiting a tertiary eye care hospital during the lockdown period. Methods: Consecutive patients attending an ophthalmic tertiary care hospital during the COVID?19 pandemic and lockdown were approached to be a part of this prospective cross?sectional survey. Results: In total, 1,088 responses were analyzed during the 2?month study period with the mean age being 45.7 + 16.9 years. The majority had completed graduation (78%) with 15 years or more of formal education. The purpose of the visit was an emergency consultation in 42% (n = 455), a review appointment in 42% (n = 457), and the remaining (16%, n = 176) came for a routine consultation. The majority of the patients (>90%) did not report experiencing any of the 14 sets of symptoms. A mild level of anxiety was noted in 1,086 (>99%) respondents, whereas only 2 (<1%) respondents showed mild–moderate levels of anxiety. Financial concerns such as affordability of medications (6% vs. 3%, P = 0.05) and fear of losing their job (16% vs. 11%, P = 0.02) were significantly more in those experiencing any anxiety compared to those with no anxiety. Conclusion: Our study revealed that patients visiting a tertiary ophthalmic center during lockdown were graduates, sought eye consultation primarily for emergency or a review, and had no major anxiety symptoms. In those with anxiety, the affordability of medicines and loss of jobs were the main concerns.

5.
Indian J Ophthalmol ; 2022 Mar; 70(3): 1007-1012
Article | IMSEAR | ID: sea-224210

ABSTRACT

Purpose: To study the use of teleophthalmology as a tool to manage patients with uveitis and to describe the experience of teleconsultation for uveitis at a tertiary eye care hospital in India during the two waves of the COVID?19 pandemic. Methods: A prospective observational case series of uveitis patients seeking teleconsultations during the first (March 25–May 2020) and second lockdown (April 27 to June 21, 2021) in a tertiary eye care center were analyzed. Results: There were 79 teleconsultations in the first and 89 teleconsultations in the second lockdown. A majority of the patients presented in the age group of 41– 60 years in both the lockdowns. There were both new or primary consultations and follow?up patients (6% vs. 94%) in the first lockdown, and similarly in the second lockdown (8% new vs. 92% follow?up). The majority of patients resided in Bengaluru city (78% in the first and 76% in the second lockdown). After evaluation through video consultation, only 15% required a hospital referral in the first lockdown, whereas in the second lockdown, 21.3% were referred to the hospital. During the second lockdown, 20% presented with COVID?19 infection?related ailments. Conclusion: Based on our preliminary experience using a customized smartphone?based application for teleconsultation, we found it to be an alternative option to provide continuation of ophthalmic care to uveitis patients. Given the current COVID?19 situation, it can help avoid physical visits of uveitis patients to the hospital

6.
Indian J Ophthalmol ; 2022 Feb; 70(2): 465-470
Article | IMSEAR | ID: sea-224123

ABSTRACT

Purpose: To compare multicolor imaging (MCI) with Optos color fundus photography (OCFP) for the evaluation of morphology and extent of preretinal membranes in diabetic tractional retinal detachments (TRD). Methods: In this retrospective study, 30 eyes with diabetic TRDs were imaged using the MCI feature of the Heidelberg Spectralis Spectral?domain optical coherence tomography (SD?OCT) and color photo using the Optos Daytona ultra?widefield fundus camera. Two investigators independently graded and determined the agreeability between the two modalities with respect to the extent of the TRD and preretinal membranes on the SD?OCT B?scan images. Results: The MCI provided better visualization of the attachments and traction points of the posterior hyaloid face and preretinal membranes and is comparable to the SD?OCT B?scan images. The inter?rater agreeability rates for OCFP had a Kappa (?) value of 0.37, while the MCI had a ? value of 0.46. When comparing between images of different wavelengths, grading using infrared reflectance (IR) had a poor agreement (?0.04 ± 0.04) while green reflectance (GR) (0.46 ± 0.32) and blue reflectance (BR) (0.53 ± 0.19) had a moderate agreement. The composite MCI and GR images also had comparatively higher intraclass coefficient when compared to the OCFP (0.25 [?0.09–0.55]) and IR (?0.03 [?0.39–0.34]) images. Conclusion: MCI is more sensitive for determining the extent of TRDs and for the detection of secondary membranes when compared to OCFP, thus, aiding in better surgical planning.

7.
Indian J Ophthalmol ; 2015 Sept; 63(9): 722-727
Article in English | IMSEAR | ID: sea-178890

ABSTRACT

Purpose: To compare and determine the repeatability of central corneal thickness (CCT) measurements using four noncontact pachymetry instruments in eyes with keratoconus. Materials and Methods: The CCT of consecutive patients with keratoconus was measured during a single visit using the swept source optical coherence tomography (SS‑OCT, Casia SS‑1000°CT, Tomey, Nagoya, Japan), a rotating Scheimpflug camera system (Pentacam, Oculus Optikgerate GmbH, Wetzlar, Germany), scanning slit topographer (Orbscan IIz topography, Baush and Lomb Surgical Inc., San Dimas, CA, USA), and a hand‑held spectral domain OCT (HHSD‑OCT, Bioptigen Inc., Durham, North Carolina, USA). Test‑retest variability, correlation between measurements and interdevice agreement were analyzed. Results: Fifty eyes of 25 participants were analyzed in this study. All measurement methods correlated well with each other (r > 0.9, P < 0.001). Mean ± standard deviation CCT measured by HHSD‑OCT, Orbscan IIz, SS‑OCT, and Pentacam was 462 ± 41 μm, 458 ± 41 μm, 454 ± 40 μm, and 447 ± 42 μm, respectively. While the HHSD‑OCT over‑estimated the CCT (P < 0.001), there was a good correlation between the measurements obtained from the other three devices. However, the numerical difference was high and this trend was seen in all the paired comparisons. Conclusions: Though the measurements by different devices correlated well, the numerical agreement may be inadequate for their interchangeable use in clinical practice.

8.
Indian J Ophthalmol ; 2015 July; 63(7): 586-593
Article in English | IMSEAR | ID: sea-170412

ABSTRACT

Purpose: Optical coherence tomography (OCT) is an important imaging tool assessing retinal architecture. In this article, we report a single centers experience of using handheld spectral domain (SD)‑OCT in a pediatric population using the Envisu 2300 (Bioptigen Inc., Research Triangle Park, NC, USA). Methods: We studied SD‑OCT images from 975 patients imaged from January 2011 to December 2014. The variety of cases that underwent an SD‑OCT was analyzed. Cases examples from different case scenarios were selected to showcase unique examples of many diseases. Results: Three hundred and sixty‑eight infants (37.7%) were imaged for retinopathy of prematurity, 362 children (37.1%) underwent the test for evaluation of suboptimal vision or an unexplained vision loss, 126 children (12.9%) for evaluation of nystagmus or night blindness, 54 children (5.5%) for an intraocular tumor or a mass lesion such as retinoblastoma, and 65 children (6.7%) for other diseases of the pediatric retina. The unique findings in the retinal morphology seen with some of these diseases are discussed. Conclusion: The handheld SD‑OCT is useful in the evaluation of the pediatric retinal diseases. The test is useful in the assessment of vision development in premature children, evaluation of unexplained vision loss and amblyopia, nystagmus and night blindness, and intraocular tumors (including retinoblastoma).

9.
Indian J Ophthalmol ; 2015 May; 63(5): 432-437
Article in English | IMSEAR | ID: sea-170363

ABSTRACT

Purpose: To report the impact of transient, self‑resolving, untreated “macular edema” detected on spectral domain optical coherence tomography in Asian Indian premature infants with retinopathy of prematurity (ROP) on visual acuity (VA) and refraction at 1‑year of corrected age. Materials and Methods: Visual acuity and refraction of 11 infants with bilateral macular edema (Group A) was compared with gestational age‑matched 16 infants with ROP without edema (Group B) and 17 preterms infants without ROP and without edema (Group C) at 3, 6, 9 and 12 months of corrected age using Teller Acuity Cards and cycloplegic retinoscopy. Sub‑group analysis of the previously described pattern A and B macular edema was performed. Results: Visual acuity was lower in infants with macular edema compared with the other two control groups throughout the study period, but statistically significant only at 3 months. Visual improvement in these infants was highest between the 3rd and 6th month and plateaued by the end of the 1st year with acuity comparable to the other two groups. The edema cohort was more hyperopic compared to the other two groups between 3 and 12 months of age. Pattern A edema had worse VA compared to pattern B, although not statistically significant. Conclusion: Macular edema, although transient, caused reduced VA as early as 3 months of corrected age in Asian Indian premature infants weighing <2000 g at birth. The higher hyperopia in these infants is possibly due to visual disturbances caused at a critical time of fovealization. We hypothesize a recovery and feedback mechanism based on the principles of active emmetropization to explain our findings.

10.
Indian J Ophthalmol ; 2015 May; 63(5): 399-403
Article in English | IMSEAR | ID: sea-170357

ABSTRACT

Optical coherence tomography (OCT) has revolutionized imaging of ocular structures and various disease conditions. Though it has been used in the clinic for some decades, the OCT has only recently found its way into the operating theater. Early attempts at intraoperative OCT, hand‑held and microscope mounted, have already improved our understanding of the surgical pathology and the role it might play in surgical decision‑making. The microscope‑integrated OCT now allows seamless, high‑resolution, real‑time imaging of surgical maneuvers from the incision to wound closure. Visualization of instruments and intraoperative tissue manipulation are possible with this in vivo modality and, therefore, help improve the outcome of surgery. In this article, we describe the advantages it offers during various vitreoretinal procedures.

11.
Indian J Ophthalmol ; 2015 May; 63(5): 373-377
Article in English | IMSEAR | ID: sea-170352

ABSTRACT

Purpose: The purpose of this study was to report the spectrum of anterior and posterior segment diagnoses in Asian Indian premature infants detected serendipitously during routine retinopathy of prematurity (ROP) screening during a 1 year period. Methods: A retrospective review of all Retcam (Clarity MSI, USA) imaging sessions during the year 2011 performed on infants born either <2001 g at birth and/ or <34.1 weeks of gestation recruited for ROP screening was performed. All infants had a minimum of seven images at each session, which included the dilated anterior segment, disc, and macula center and the four quadrants using the 130° lens. Results: Of the 8954 imaging sessions of 1450 new infants recruited in 2011, there were 111 (7.66%) with a diagnosis other than ROP. Anterior segment diagnoses seen in 31 (27.9%) cases included clinically significant cataract, lid abnormalities, anophthalmos, microphthalmos, and corneal diseases. Posterior segment diagnoses in 80 (72.1%) cases included retinal hemorrhages, cherry red spots, and neonatal uveitis of infective etiologies. Of the 111 cases, 15 (13.5%) underwent surgical procedures and 24 (21.6%) underwent medical procedures; importantly, two eyes with retinoblastoma were detected which were managed timely. Conclusions: This study emphasizes the importance of ocular digital imaging in premature infants. Visually significant, potentially life‑threatening, and even treatable conditions were detected serendipitously during routine ROP screening that may be missed or detected late otherwise. This pilot data may be used to advocate for a possible universal infant eye screening program using digital imaging.

12.
Indian J Ophthalmol ; 2015 May; 63(5): 370-372
Article in English | IMSEAR | ID: sea-170351
15.
Indian J Ophthalmol ; 2015 Apr; 63(4): 323-326
Article in English | IMSEAR | ID: sea-158622

ABSTRACT

Objectives: The objective was to determine the repeatability of intraocular pressure (IOP) measurements made through a soft contact lens (CL) using the Scheimpflug noncontact tonometry in healthy subjects. Methods: This prospective, randomized, single‑center study included one eye of 88 subjects (40 male and 48 female). Only participants without glaucoma or any other ocular pathology were included in this study. Three consecutive IOP measurements by the Scheimpflug noncontact tonometry were performed with and without daily disposable hydrogel CLs (−0.50 DS) (Dailies‑nelfilcon A, 69% water, 8.7 mm base curve, 14 mm diameter, center thickness 0.10 mm) by a single operator. To avoid any bias arising from diurnal variation, all measurements were made at a similar time of day (11 am ± 1 h). The repeatability of IOP measurements using the Scheimpflug noncontact tonometry with and without CLs was evaluated using Pearson’s correlation analysis. Bland–Altman plotting was used to assess the limits of agreement between the measurements with and without CLs. Results: The mean (± standard deviation) IOPs with and without CL were 13.80 ± 2.70 and 13.79 ± 2.54 mm of Hg respectively. The mean difference was 0.01 ± 0.16 (95% confidence interval, +1.97 to − 2.00) mm Hg. Statistical analysis via paired t‑test showed no statistical difference between the two groups with (P = 0.15). A good correlation was found for IOP measurements with and without CL (r = 0.93, P < 0.001). Good test‑retest reliability was found when IOP was measured with and without CL. Conclusion: There was no significant difference between IOP measured with and without CLs by Scheimpflug noncontact tonometry.

16.
Article in English | IMSEAR | ID: sea-176825
17.
Indian J Ophthalmol ; 2015 Jan; 63(1): 46-53
Article in English | IMSEAR | ID: sea-158502

ABSTRACT

Keratoconus is a slowly progressive, noninflammatory ectatic corneal disease characterized by changes in corneal collagen structure and organization. Though the etiology remains unknown, novel techniques are continuously emerging for the diagnosis and management of the disease. Demographical parameters are known to affect the rate of progression of the disease. Common methods of vision correction for keratoconus range from spectacles and rigid gas‑permeable contact lenses to other specialized lenses such as piggyback, Rose‑K or Boston scleral lenses. Corneal collagen cross‑linking is effective in stabilizing the progression of the disease. Intra‑corneal ring segments can improve vision by flattening the cornea in patients with mild to moderate keratoconus. Topography‑guided custom ablation treatment betters the quality of vision by correcting the refractive error and improving the contact lens fit. In advanced keratoconus with corneal scarring, lamellar or full thickness penetrating keratoplasty will be the treatment of choice. With such a wide spectrum of alternatives available, it is necessary to choose the best possible treatment option for each patient. Based on a brief review of the literature and our own studies we have designed a five‑point management algorithm for the treatment of keratoconus.

18.
Indian J Ophthalmol ; 2014 Jan ; 62 (1): 50-54
Article in English | IMSEAR | ID: sea-155504

ABSTRACT

Photocoagulation is the standard of care for several ocular disorders and in particular retinal conditions. Technology has off ered us newer lasing mediums, wavelengths and delivery systems. Patt ern scan laser in proliferative diabetic retinopathy and diabetic macular edema allows laser treatment that is less time consuming and less painful. Now, it is possible to deliver a subthreshold micropulse laser that is above the threshold of biochemical eff ect but below the threshold of a visible, destructive lesion thereby preventing collateral damage. The advent of solid-state diode yellow laser allows us to treat closer to the fovea, is more eff ective for vascular structures and off ers a more uniform eff ect in patients with light or irregular fundus pigmentation. Newer retinal photocoagulation options along with their advantages is discussed in this review.

19.
Indian J Ophthalmol ; 2013 Jun; 61(6): 309-310
Article in English | IMSEAR | ID: sea-148199

ABSTRACT

A 65-year-old male presented with decreased vision in the left eye of 15-day duration after having undergone an uneventful cataract surgery 10 months back. He had been previously treated with systemic steroids for recurrent uveitis postoperatively on three occasions in the same eye. B-scan ultrasonography showed multiple clumplike echoes suggestive of vitreous inflammation. Aqueous tap revealed Pseudomonas aeruginosa sensitive to ciprofloxacin. The patient was treated with intravitreal ciprofloxacin and vancomycin along with systemic ciprofloxacin with good clinical response. Even a virulent organism such as P.aeruginosa can present as a chronic uveitis, which, if missed, can lead to a delay in accurate diagnosis and appropriate management.

20.
Indian J Ophthalmol ; 2008 May-Jun; 56(3): 231-2
Article in English | IMSEAR | ID: sea-72391

ABSTRACT

We report a 25-year-old systemically healthy male who presented with periocular necrotizing fasciitis (NF) in the left eyelid. This was associated with the presence of immunologically mediated marginal kerato-conjunctivitis, in the same eye. This potentially dangerous lid infection and the associated ocular surface infection resolved successfully, with medical management. We report this case to highlight the successful conservative management of periocular NF and the hitherto unreported anterior segment involvement.


Subject(s)
Administration, Oral , Adult , Amoxicillin-Potassium Clavulanate Combination/therapeutic use , Anti-Infective Agents/therapeutic use , Ceftriaxone/therapeutic use , Drug Therapy, Combination , Eyelid Diseases/drug therapy , Fasciitis, Necrotizing/drug therapy , Humans , Infusions, Intravenous , Keratoconjunctivitis/drug therapy , Male , Metronidazole/therapeutic use , Staphylococcal Infections/drug therapy , Staphylococcus aureus/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL