Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedics ; (12): 1423-1432, 2022.
Article in Chinese | WPRIM | ID: wpr-957137

ABSTRACT

Objective:To investigate the early clinical effects of orthopedic surgery robot-assisted double Endobutton titanium plate internal fixation in the treatment of fresh acromioclavicular joint dislocation.Methods:Thirty-nine patients with fresh acromioclavicular joint dislocation were included from January 2020 to January 2022. A total of 19 patients were treated with double Endobutton suspension internal fixation assisted by the domestic third-generation orthopaedic surgical robot (TiRobot ? 2.0) Dimensity system. There were Rockwood type III in 11 cases, type IV in 8 cases. Twenty cases were treated with conventional incision double Endobutton internal fixation, with Rockwood type III in 13 cases, type V in 7 cases. The operation duration, blood loss volume, incision length and hospitalization time were compared between the two groups. The following CT parameters of acromioclavicular joint at 2 days and 1 year after operation, distance between distal inferior cortex of clavicle and subacromial cortex, distance between upper and lower endobuttons, horizontal distance between anterior edge of distal clavicle and anterior edge of acromion and diameter of coracoid process and diameter of clavicular tunnel were measured. The visual analogue score (VAS), Constant-Murley shoulder function score and shoulder abduction activity were also evaluated before and at 12 months after operation. Results:The follow-up duration was 10.8±2.4 months in the robot group and 11.5±3.1 months in the routine group. The VAS score of the robot group decreased from 5.3±2.1 to 0.3±0.2 at 12 months after operation ( t=10.46, P=0.014). The Constant-Murley score increased from 55.6±6.4 to 92.0±4.2. The range of shoulder abduction increased from 42.2°±5.4° to 172.6°±6.1° ( t=17.24, P<0.001). The operation duation of the robot group was 74.4±6.6 min, which was longer than that of the conventional group 61.7±7.2 min ( t=5.43, P=0.037). There was no significant difference in VAS score, Constant-Murley score, shoulder abduction activity or CT measurement between the two groups ( P>0.05). During the follow-up, two cases in the robot group had cortical osteolysis on the supraclavicular surface, one case in the conventional group had loss of reduction, one case in the supraclavicular cortical osteolysis, and 4 cases in the cortical defect on the side of the coracoid process tunnel. Conclusion:Orthopedic robot-assisted and conventional incision with double Endobutton titanium plate internal fixation in treating fresh acromioclavicular joint dislocation can achieve satisfied early clinical effects. Accurate establishment of clavicle and coracoid bone tunnel assisted by robot can overcome the defects of bone tunnel deviation in conventional incision operation and can prevent reduction and bone loss. However, robot-assisted and conventional incision Endobutton internal fixation could enlarge bone tunnel.

2.
Chinese Journal of Orthopaedics ; (12): 1387-1395, 2021.
Article in Chinese | WPRIM | ID: wpr-910727

ABSTRACT

Objective:By comparing the clinical effect of minimally invasive hollow screw internal fixation Assisted by orthopedic robot (TiRobot) and O-arm navigation in the treatment of pelvic fractures, and practicability and security of both treatments were evaluated.Methods:Retrospective analysis of data of 42 cases of Tile C type pelvic fractures was employed during June 2017 to June 2020. Among them, 32 cases, twenty-four men, eight women, aged 34±6.2 years (range 24-68 years), were treated with percutaneous screw fixation guided by O-arm X wire instrument. According to Tile classification, there were 3 cases of C1.1 type, 8 cases of C1.2 type and 21case of C1.3 type. According to the Denis classification of sacral fractures, 17 cases were in zone I, and 8 cases in zone II. Ten patients, eight males and two females, aged 36±5.2 years (range 19-62 years) were treated by percutaneous screw fixation assisted by orthopedic robot. According to Tile classification, there were 1 case of C1.1 type, 2 cases of C1.2 type and 7 cases of C1.3 type. According to the Denis classification of sacral fractures, there were 5cases in zone I, 2 cases in zone II. For those who got obviously displaced pelvic fractures, Starr frames were used and then internal fixation was used to fix pelvic anterior ring and posterior ring injury respectively. Based on the times of needle adjustments, intraoperative fluoroscopy time, good screw position and incidence of complications two groups were statistically analysed. Matta score was employed to evaluate the quality of fracture reduction, while the Majeed score was employed to evaluate the clinical efficacy. Through the two groups of cases guide needle adjustment times, intraoperative fluoroscopy time, screw position excellent and good rate and the incidence of complications, which were statistically analyzed.Results:All screw positions were confirmed by CT scan after operation. The average time required for each screw placement of the O-arm group was 7.36±2.63 s, of the robot group was 6.80±3.20 s, so difference was not statistically significant ( P<0.05). An average of screw adjustments per one screw was 1.56±0.02 times by O-arm, and by the robot group was 0.34±0.06 times, so differences between the two groups were statistically significant ( P>0.05). The average operating time of O-arm group was 53.86±15.06 min, while the robot group was 52.52±15.14 min, so differences between the two groups were not statistically significant ( P>0.05). Position distribution of screw placement in two groups, all screws in O-arm group of position evaluations were excellent, excellent rate was 100%, all screw position evaluations by robot were excellent, excellent rate was 100%, so difference in screw distribution between the two groups was not statistically significant ( P>0.05). All cases were followed up for 6-12 months. Fracture healing time: 34.6±8.6 weeks for O-arm group, 33.4±9.4 weeks for robot group. Comparison between the two groups was not statistically significant ( P>0.05). Majeed score of O-arm group was 55-87, including Excellence of 17 cases, goodness of 9, fairness of 6. The rate of excellence and goodness was 81.2%, while robot group was 76-95, and that were excellent 7 cases,1 good, and the excellent and good rate was 80%, there was no significant difference between Matta and Majeed score between the two groups ( P>0.05). The incidence of complications between the two groups were no statistically significant ( P>0.05). Conclusion:Orthopedic robot system and O-arm navigation system assisted by percutaneous hollow screw fixation treatment of pelvic anterior and posterior ring injury, which are accurate, safe, minimally invasive, can reduce radiation damage to patients and surgeons. The efficacy were satisfactory. Both treatments are ideal for minimally invasive treatment of pelvic fractures, and the orthopedic robot have advantages of being programmed, standardized, stable and it’s learning curve is shorter.

3.
Chinese Journal of Orthopaedics ; (12): 302-309, 2020.
Article in Chinese | WPRIM | ID: wpr-868975

ABSTRACT

Objective:To investigate the feasibility and clinical efficacy of percutaneous screw fixation for acetabular anterior column fracture with laser-assisted axial fluoroscopy.Methods:Data of 20 patients (22 sided) with acetabular anterior column fracture treated by percutaneous screw fixation with laser-assisted axial fluoroscopy from January 2017 to December 2018 were retrospectively analyzed. There were 11 males and 9 females with an average of 42.1±3.2 years (range, 24-68 years). There were 7 cases of unilateral acetabular anterior column fracture, 2 cases of bilateral acetabular anterior column fracture (4 sides), 7 cases of anterior column with ipsilateral sacral fracture, and 4 cases of anterior column with sacroiliac joint injury. There were 3 hips of Area I, 6 Area II, 13 Area III of acetabular anterior column fractures according to Nakatani partition. The time from injury to surgery was 5 days (range, 3-11 days). All patients with acetabular anterior column fractures were fixed by percutaneous screw fixation with laser-assisted axial fluoroscopy, and patients with sacral fracture or sacroiliac joint injury were fixed by percutaneous sacroiliac screws with Starr frame-assisted reduction. The time of operation, the number of intraoperative fluoroscopy and the amount of intraoperative bleeding were recorded. Matta scoring criteria were used to assess fracture reduction quality, and hip function was assessed at the last follow-up according to the modified Merle D' Aubigné and Postel scoring system.Results:The average operative time was 22±10 min (range, 20-40 min) with an average times of intraoperative fluoroscopy of 30±8 times (range, 21-45 times), and the amount of intraoperative blood loss was 20±5 ml (range, 10-40 ml). 20 patients were followed up after operation for a period of 14±3.1 months (range, 12-18 months). The quality of postoperative fracture reduction was assessed according to the Matta acetabular fracture reduction criteria: anatomical reduction in 18 hips, satisfactory reduction in 2 hips, unsatisfactory reduction in 2 hips, with an excellent and good rate of 91% (20/22). The fracture healing time was 13±2.2 weeks (range, 11-16 weeks). At the lastest follow-up, hip function was assessed according to the modified Merle D' Aubigné and Postel scoring system: excellent 18, good 3, fair 1, and the satisfactory rate was 95%(21/22). No major neurological, vascular injury, wound infection and ectopic ossification were found during follow-up.Conclusion:Using laser-assisted axial fluoroscopy percutaneous screw to treat acetabular anterior column fracture, the operation is simple. And there is low risk to damage important blood vessels and nerves. This method can shorten the operation time of acetabular anterior column fracture, reduce the amount of blood loss during the operation, and the outcome is satisfactory.

SELECTION OF CITATIONS
SEARCH DETAIL