Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
RGO (Porto Alegre) ; 65(4): 299-302, Oct.-Dec. 2017. tab, graf
Article in English | LILACS, BBO | ID: biblio-896038

ABSTRACT

ABSTRACT Objective : This study aimed to evaluate the D0 diameter of standardized gutta-percha cones for four mechanized systems: ProTaper Universal®, Mtwo®, Wave One® and Reciproc®. Methods: An endodontic calibrator ruler was used to measure the D0 diameter of 60 main cones of the above systems. Measurements were made according 3 scores as follows: gutta-percha cone fits exactly into the same hole as the endodontic ruler gauge (score 1), cone falls short of the ruler gauge whole size (score 2); or exceeding the ruler gauge hole size (score 3). The diameters D0 obtained were compared with the values reported by manufacturers. All data were analyzed by means of T Test, at 1% level of significance. Results: The average value measured was significantly higher than the measures established by manufacturers (p <0.001). Conclusion : The gutta-percha cones of ProTaper Universal® systems Mtwo®, Wave One® and Reciproc® were not standardized, except for R40 cone of the Reciproc® system (Reciproc®). The trend was for variation in the D0 Diameter towards increasing measurement values.


RESUMO Objetivo: Avaliar o diâmetro D0 de cones estandardizados de guta-percha de quatro sistemas mecanizados: ProTaper Universal®, Mtwo®, Wave One® e Reciproc® . Métodos: Por meio de uma régua endodôntica calibradora, foi aferido o diâmetro D0 de sessenta cones principais dos sistemas supracitados. A aferição foi realizada de acordo com os três escores a seguir: o cone de guta-percha se adapta exatamente no mesmo calibre de orifício da régua endodôntica (escore 1), o cone fica aquém ao calibre de orifício da régua (escore 2) ou além do respectivo calibre do orifício da régua (escore 3). Os diâmetros em D0 obtidos foram comparados aos valores divulgados pelos fabricantes. Todos os dados foram tratados por meio do Teste T, ao nível de significância de 1%. Resultados: As médias aferidas foram significativamente maiores do que as medidas estabelecidas pelos fabricantes (p<0,001). Somente os cones R40 do sistema Reciproc® estiveram no padrão. Conclusão: Os cones de guta-percha dos sistemas ProTaper Universal®, Mtwo®, Wave One® e Reciproc® não apresentam padronização, à exceção do cone R40 ( Reciproc® ). Houve uma tendência de variação do diâmetro D0 para uma maior medida.

2.
RSBO (Impr.) ; 13(1): 5-10, Jan.-Mar. 2016. ilus, tab
Article in English | LILACS | ID: biblio-842400

ABSTRACT

Introduction and Objective: The present study aimed to examine the correlation between atmospheric temperature and the occurrence of irreversible pulpitis. Material and methods: Data was collected from the Department of Dentistry, Moinhos de Vento Hospital, Porto Alegre between July 2011 and December 2012. A total of 52 pulpitis clinical cases were examined in 529 days in this study. Data on the atmospheric temperature in Porto Alegre on each day was collected from the Porto Alegre Meteorology Institute. Results and Conclusion: Correlation analysis of the temperature data and pulpitis cases was conducted using Student's t-test, with a significance level of 5%. Although no correlation was observed between the occurrence of irreversible pulpitis and atmospheric temperature, the incidence rates were higher on days when the average temperature was greater than 25ºC.

3.
Stomatos ; 21(41): 35-43, jul. dez. 2015.
Article in English | LILACS | ID: biblio-1737

ABSTRACT

Endodontic retreatment is a clinical intervention intended to correct errors that have occurred in a treatment performed previously. There are several causes of failures. The anatomical variations between root canals and the diffi culties of achieving microbial disinfection are reported as two of the main causes. However, in the dental offi ces of both general practitioners and specialists, it is very common that the causes of indications for endodontic retreatment are technical failures due to poorly executed treatment. In view of this, the objective of this study is to analyze the records of three specialists in Endodontics and analyze the causes for referral of their endodontic retreatment patients. Examination of 24,553 treatments conducted over varying periods revealed that cases of retreatment accounted for a considerable proportion of the routine work performed by these specialists, at an average of 23% of cases. The majority of retreatment indications were due to technical failure of the initial treatment, in combination with microbial factors caused by contamination of coronal restorations and poorly executed endodontic preparation and fi lling.


O retratamento endodôntico é uma intervenção clínica destinada para a correção de falhas ocorridas num tratamento anteriormente realizado. Vários são os motivos desencadeadores de insucessos. A variedade anatômica dos canais radiculares e a difi culdade de proporcionar a desinfecção microbiana são referenciadas como duas das causas principais. Entretanto, nos consultórios dentários de clínicos gerais e especialistas, é muito comum a indicação para oretratamento endodôntico por razões técnicas devido a sua mal execução. Estabelecida esta problemática, o objetivo deste estudo consiste em avaliar os prontuários de três especialistas em endodontia e verifi car quais são os motivos de encaminhamentos de seus pacientes para o retratamento endodôntico. Após o exame de 24.553 tratamentos em períodos distintos, verifi couse que os casos de retratamentos chegam a uma média relevante de 23% na rotina destes especialistas e que a maioria das indicações se deram por inabilidade no primeiro tratamento, aliadas ao fator microbiano causado por contaminações de restaurações coronárias, preparos e obturações endodônticas mal executadas.


Subject(s)
Retrograde Obturation , Retreatment , Endodontics , Root Canal Obturation/adverse effects , Root Canal Therapy/adverse effects , Root Canal Preparation , Dental Restoration Failure
4.
RSBO (Impr.) ; 12(3): 285-288, Jul.-Sep. 2015. ilus
Article in English | LILACS | ID: biblio-842379

ABSTRACT

Introduction and Objective:To analyze the time required to dissolute the pulp tissue under different methods of sodium hypochlorite activation. Material and methods: 30 bovine pulp fragments, with an approximate volume of 45 ± 5 mg were divided into three experimental groups (n = 10). In group 1, only the fragments were immersed in 15 ml of 2.5% sodium hypochlorite. In group 2, the irrigant was manually stirred with an endodontic instrument type K size 40. In group 3, we used the ultrasonic insert n.39, driven by ultrasound device Jet Sonic Total. The time required for total dissolution of bovine tissue was measured and recorded for statistical analysis. Results and Conclusion: According to analysis of variance (Anova), with p<0.05, Group 1 showed significantly higher dissolution time than Groups 2 and 3. Moreover, no difference between the use of ultrasound and manual activation of the irrigating solution was found.

5.
Rev. odontol. UNESP (Online) ; 43(6): 367-371, Nov-Dec/2014. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-730684

ABSTRACT

Introdução: O preenchimento com material endodôntico obturador em dentes com reabsorção radicular interna é extremamente difícil. Objetivo: Avaliar a eficácia de duas técnicas de obturação no preenchimento de cavidades experimentais de reabsorção interna. Material e método: Vinte incisivos centrais superiores artificiais, com a presença de uma cavidade simulada padronizada de reabsorção no terço médio do canal radicular, foram utilizados. Após o preparo endodôntico dos dentes, os mesmos foram randomicamente divididos em dois grupos (n=10), de acordo com a técnica de obturação empregada: híbrida de Tagger ou com auxílio do sistema ultrassônico. A verificação da obturação endodôntica, junto à cavidade de reabsorção interna, foi feita por meio da tomada radiográfica com dois tipos de incidência: mesiodistal e vestibulolingual. Para a análise da área de obturação, foi empregado o programa Image Tool®. Os dados obtidos da obturação foram submetidos à análise estatística por meio do Teste t de Student, com nível de significância de 5%. Resultado: Não houve diferença estatística entre as técnicas de obturação testadas. Apenas pôde-se observar diferença significativa nos dentes obturados com auxílio do ultrassom, quando se comparou a incidência radiográfica realizada no sentido mesiodistal com a vestibulolingual. Conclusão: As duas técnicas de obturação testadas foram similares no preenchimento da cavidade de reabsorção interna. .


Introduction: The filling with obturation endodontic material in teeth with internal root resorption is extremely difficult. Objective: To evaluate the efficacy of two obturation techniques in the filling of experimental internal resorption cavities. Material and method: Twenty maxillary central incisors artificial, with the presence of a standardized simulated resorption cavity in the middle third of the root canal were used. After endodontic treatment of teeth, they were randomly divided into two groups (n=10), according to the obturation technique used: hybrid Tagger or with the aid of the ultrasonic system. Verification of endodontic obturation, with the cavity internal resorption, was taken by radiography with two types of incidence: mesiodistal and buccolingual. For the analysis of area closures, we used the Image Tool® program. The data of the filling were subjected to statistical analysis using Student's t test, with significance level of 5%. Result: There was no statistical difference between the tested obturation techniques. As one can observe a significant difference in teeth obturated with the aid of ultrasound, when compared to the radiograph performed in mesiodistal with buccolingual. Conclusion: The two obturation techniques tested were similar to fill the cavity of internal resorption. .


Subject(s)
Root Canal Obturation , Tooth Resorption , Radiography, Dental , Dental Instruments , Endodontics , Incisor
6.
Stomatos ; 20(39): 18-27, Jul.-Dec. 2014. tab
Article in English | LILACS | ID: lil-784026

ABSTRACT

Um dos grandes desafios no tratamento de canais curvos é manter suas características originais. Este estudo teve como objetivo examinar se o tipo de sistema utilizado com os instrumentos rotatórios NRT® poderia infl uenciar a ocorrência de desvio na região apical. Métodos: Vinte canais curvos simulados foram divididos em dois grupos experimentais. No Grupo 1, a preparação dos canais foi realizada com um sistema pneumático, com velocidade constante mas sem controle de torque. No Grupo 2, utilizou-se um motor elétrico com velocidade constante e controle de torque. Os blocos simulados foram fotografados antes e após a preparação utilizando uma plataforma para que a mesma posição fosse mantida nas duas fotografias. As imagens foram manipuladas no software Adobe Photoshop® para avaliar o desvio a 1 mm e a 3 mm do comprimento de trabalho. O teste t foi usado para fazer a análise estatística dos dados. O nível de significância foi estabelecido em 1%. Resultados e conclusão: O Grupo 2 (motor elétrico) mostrou valores menores de desvio nos dois pontos analisados (1 mm e 3 mm do comprimento de trabalho). Em ambos os grupos, as áreas localizadas a 3 mm do comprimento de trabalho apresentaram desvio médio menor do que as áreas localizadas a 1 mm do comprimento de trabalho...


One of the major challenges encountered in treatment of curved canals is maintaining their original features. This study aimed to examine whether the type of system used with NRT® rotary instruments might infl uence the occurrence of deviation in the apical region. Methods: Twenty simulated curved canals were divided into two experimental groups. In Group 1, canal preparation was performed with the pneumatic hand piece, using constant speed, but without torque control. In Group 2, an electric motor with constant speed and torque control was used. The simulated blocks were photographed before and after preparation using a platform to maintain the same position in both photographs. Images were manipulated in Adobe Photoshop® to evaluate deviation at 1 mm and 3 mm from the working length (WL). The t test was used for statistical analysis of data. The significance level was set at 1%. Results and Conclusion: Group 2 (electric motor) had lower values for deviation at both locations analyzed (1 mm and 3 mm from the WL). In both groups, sites 3 mm from the WL had lower mean deviation than sites 1 mm from WL...


Subject(s)
Humans , Dental Instruments , Root Canal Preparation , Endodontics
7.
RSBO (Impr.) ; 7(4): 488-493, out.-dez. 2010. ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-564423

ABSTRACT

Introdução e objetivo: Mostrar a possibilidade de tratamento pormeio da curetagem periapical associada ao uso do ultrassom, semhaver a necessidade de odontosecção da porção apical da raiz dentária.Relato de caso: Realizaram-se tratamento endodôntico do dente 41 eretratamento do dente 42, e em seguida fez-se procedimento cirúrgicoparendodôntico na área de lesão periapical. A proservação do casodeu-se em dois anos, e foram verificados regressão e reparo ósseototal da área de lesão. Conclusão: Com a associação da tecnologia àprática clínica é possível efetuar um tratamento cirúrgico de formarápida, segura e conservadora.


Introduction and objective: This study aimed to demonstrate thepossibility of treatment, through periapical curettage with the aid ofultrasound, consequently without the need of resection of root?s apicalportion. Case report: The endodontic treatment of tooth #41 andretreatment of tooth #42 was performed. Following, the periapical lesion areas were submitted to parendodontic surgery. After a 2-yearfollow-up period, it could be verified a total lesion area regression andbone repair. Conclusion: The association of technology with clinicalpractice seemed to result in a faster, safer, and more conservativesurgical treatment.

8.
Stomatos ; 15(29)jul.-dez. 2009.
Article in Portuguese | LILACS | ID: lil-567130

ABSTRACT

Este estudo teve como objetivo avaliar de forma qualitativa a expectativa e o aprendizado que o CEO tem proporcionado ao aluno de graduação em Odontologia da ULBRA. Para isso, foi realizado um questionário com seis perguntas abertas aos acadêmicos que estavam matriculados nesta disciplina curricular. Dos 43 alunos inscritos, 29 (67%) responderam as perguntas. Por meio da análise das respostas obtidas pode-se observar que este estágio curricular foi muito importante para o desenvolvimento crítico e profissional dos alunos participantes


This study aimed to evaluate of qualitative form the expectation and the training that the CEO has proportionate to the student of graduation in Dentistry of the ULBRA. For this, a questionnairewith six open questions to the academics was carried out to students who were registered in this curricular discipline. Of the 43 enrolled students 29 (67%) had answered the questions. By means of the analysis of the gotten answers it can be observed that this curricular period of training wasvery important for the development critic and professional of the participant students.


Subject(s)
Educational Measurement , Health Services Research , Curriculum , Universities , Education, Dental , Specialties, Dental , Evaluation Studies as Topic , Health Education , Dental Health Services
9.
Rev. Assoc. Paul. Cir. Dent ; 62(6): 470-474, nov.-dez. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-535068

ABSTRACT

Este trabalho teve como objetivo avaliar a adaptação dos cones estandardizados de guta-percha do sistema ProTaper® (F1, F2 e F3) em relação aos respectivos instrumentos endodônticos do mesmo sistema, através da utilização de dois tipos de réguas endodônticas calibradoras, Ângelus® e Dentsply®. Após a obtenção dos resultados, os dados foram tratados através do programa t-student com um nível de significância de 5%, podendo-se constatar que a maioria dos cones não apresentou uma padronização no seu diâmetro apical.


This work had as objective to evaluate the adaptation of the gutta-percha standardized cones of ProTaper® system (F1, F2 and F3) in relation to the respective endodontic instruments, of the same system, through the use of two types of endodontic scales, Angelus® and Dentsply®. After getting the results, the data had been obtained with the t-student program considering a level of 5% significance, being able itself to shaw that the majority of the cones did not present a standardization in its apical diameter.


Subject(s)
Dental Instruments , Dental Pulp Cavity , Endodontics/methods
10.
Stomatos ; 13(24): 53-62, jan.-jun. 2007.
Article in Portuguese | LILACS, BBO | ID: lil-542154

ABSTRACT

Este trabalho consiste numa revisão de literatura sobre a utilização do laser durante arealização do tratamento endodôntico. Neste artigo, mostraremos algumas etapas da terapia endodôntica em que esses aparelhos podem ser utilizados, suas influências nas estruturas dentárias e as suas contra-indicações.


This work consists in a literature review on the use of the laser during the accomplishment ofthe endodontics treatment. In this article, we will show someone stages of the endodontics therapy where if they use these devices, it’s influences in the dental structures and it’s against indications.


Subject(s)
Humans , Endodontics , Laser Therapy , Laser Therapy
11.
Stomatos ; 12(22): 31-34, jan.-jun. 2006.
Article in Portuguese | LILACS, BBO | ID: lil-542138

ABSTRACT

Este artigo visa discutir, baseado em uma revisão de literatura, a influência da esterilização e dasolução de hipoclorito de sódio sobre as propriedades dos instrumentos endodônticos. Pode-se verificarque não houve alterações significativas nas propriedades dos instrumentos endodônticos quando subme-tidos a vários ciclos de esterilização e ao contato com a solução de hipoclorito de sódio.


This paper aims to discuss by means of a literature review, influence of sterilization and sodium hypochlorite solution in properties of endodontics instruments. Can be verified that didn’t have significant alterations in properties of endodontics instruments when submitted to some cycles of sterilization and sodium hypochlorite solution.


Subject(s)
Endodontics , Sterilization , Sodium Hypochlorite , Dental Instruments
SELECTION OF CITATIONS
SEARCH DETAIL