Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Clinical Endoscopy ; : 334-339, 2019.
Article in English | WPRIM | ID: wpr-763456

ABSTRACT

BACKGROUND/AIMS: We applied a back light system (BLS) with a magnifying glass to improve the ability to assess the adequacy of specimen sampling using endosonography. We conducted this study to evaluate the efficacy of the BLS in sampling of specimens by endoscopic ultrasound-guided fine needle aspiration of solid pancreatic masses. METHODS: This was a prospective, randomized, crossover, single-center clinical trial. An endosonographer evaluated adequacy on gross visual inspection and identified whitish specimen sampling sites with and without the BLS according to a randomization sequence in the first and second passes with a 25-G needle. On cytological evaluation, the presence of well-defined pancreatic ductal epithelium was evaluated by a cytopathologist who was blinded to any clinical information. RESULTS: A total of 80 consecutive patients were eligible during the study period. Adequacy was observed for 52 specimens (65%) with the BLS and 54 (68%) without the BLS (p=0.88). In assessment of specimen adequacy on gross examination, only fair agreement was observed both with and without BLS (kappa score 0.40 and 0.29, respectively). CONCLUSIONS: The BLS did not influence the ability to identify specimen sampling sites or reliable assessment of specimen site adequacy using gross visual inspection.


Subject(s)
Humans , Biopsy, Fine-Needle , Cross-Over Studies , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Endosonography , Epithelium , Glass , Needles , Pancreatic Ducts , Pancreatic Neoplasms , Prospective Studies , Random Allocation
2.
Gut and Liver ; : 306-311, 2017.
Article in English | WPRIM | ID: wpr-69987

ABSTRACT

A newly developed short double-balloon enteroscope with a working channel enlarged to a diameter of 3.2 mm is a novel innovation in stent placement for patients with surgically altered anatomies. Herein, we report three patients in whom this new scope contributed to an efficient technique and ideal treatment. In the first case, the double guidewire technique was efficient and effective for multiple stent placements. In the second case, covered self-expandable metal stent (SEMS) placement, which is the standard treatment for malignant biliary obstruction, could be performed in a technologically sound and safe manner. In the third case, SEMS placement was performed as palliative treatment for malignant afferent-loop obstruction; this procedure could be performed soundly and safely using the through-the-scope technique. The wider working channel of this new scope also facilitates a smoother accessory insertion and high suction performance, which reduces procedure time and stress on endoscopists. Furthermore, this new scope, which has advanced force transmission, adaptive bending, and a smaller turning radius, is expected to be highly successful in both diagnosis and therapy for various digestive diseases in patients with surgically altered anatomies.


Subject(s)
Humans , Cholangiopancreatography, Endoscopic Retrograde , Diagnosis , Double-Balloon Enteroscopy , Gastric Outlet Obstruction , Palliative Care , Radius , Stents , Suction
SELECTION OF CITATIONS
SEARCH DETAIL