Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Braz. dent. sci ; 20(2): 146-151, 2017. ilus
Article in English | LILACS, BBO | ID: biblio-846451

ABSTRACT

Removable Partial Dentures (RPD) with dual path of insertion are designed to overcome conventional RPD esthetic limitations, through the use of proximal undercuts for rigid direct retainers. Therefore, dual path RPD is considered a variation of conventional RPD. This paper reports a clinical case where proper function as well as excellent esthetics were obtained with this type of RPD. (AU)


Próteses parciais removíveis (PPR) com dupla trajetória de inserção são próteses projetadas para superar limitações estéticas das próteses convencionais, utilizando-se retentores diretos rígidos nas áreas retentivas proximais dos dentes suportes. Desta forma, a PPR com dupla trajetória da inserção é considerada uma variação da PPR tradicional. O objetivo deste artigo é relatar um caso clínico onde se obteve uma resolução funcional e altamente estética através deste tipo de PPR..(AU)


Subject(s)
Humans , Denture, Partial, Removable
2.
ImplantNews ; 12(1): 62-72, 2015. ilus
Article in Portuguese | LILACS, BBO | ID: lil-749375

ABSTRACT

Este trabalho relata um caso clínico do uso do sistema CAD/CAM para confecção da infraestrutura metálica. Um paciente de 57 anos de idade apresentava-se com uma prótese total metalocerâmica superior de longa data e próteses mandibulares bilaterais sobre dois implantes cada, afetados pela peri-implantite. O planejamento incluiu a remoção dos implantes afetados e a colocação de quarto novos implantes entre os forâmenes mentonianos, mas sem carregamento imediato em função da atividade parafuncional do paciente. A infraestrutura metálica foi fresada a partir de uma bolacha de CoCr em dez minutos. Cada cantiléver apresentou extensão de 20 mm. A adaptação passiva da prótese mandibular definitiva confirmou as possibilidades e benefícios da tecnologia CAD/CAM para próteses totais fixas implantossuportadas.


This paper reports a clinical case where a CAD/CAM system was used to fabricate a metallic framework. A 57 years-old patient presented with an old tooth-supported fused-to-metal prosthesis in the maxilla and bilateral mandibular implant-supported prostheses (two implants each) affected by peri-implantitis. The treatment planning included removal of infected implants and placement of four new dental implants between mental foramina, but with no immediate loading due to the patient´s parafunctional activities. The metallic infra-structure was milled from a CoCr disk in ten minutes. Each cantilever had a 20 mm-length. The passive fit of the definitive mandibular prosthesis was deemed excellent and confirmed the possibilities and benefi ts of the CAD/CAM technology for complete fixed implant-supported prostheses.


Subject(s)
Humans , Male , Middle Aged , Dental Implants , Denture, Complete , Peri-Implantitis , Metal Ceramic Alloys
3.
Braz. dent. sci ; 17(3): 50-53, 2014. ilus, tab
Article in English | LILACS, BBO | ID: lil-743036

ABSTRACT

The objective of this study was to evaluate the influence of different speeds using the piston device in the shear bond strength. 48 cylinders of composed resin had been confectioned (Solidex),and were divided randomly in four groups (n=12). The specimens were adapted to the device for the shear bond strenth test and were taken to an universal testing machine with a load cell of 1000 Kg. The test were carried through with four different speeds: group A: 0.5; group B: 1.0; group C: 1.5 and group D: 2.0 mm/min. The mean and standard deviations, in Kgf, were: A - 66,31 (10,24); B - 64,53 (20,40); C - 75,23 (11,84) and D - 66,62 (13,81). The data were submitted to ANOVA (p = 0.13). The results indicated that it did not have statistical significant difference between the groups A, B, C and D concluding that the speed in this type of test, with this device, can be varied without modify results


O objetivo do presente estudo foi avaliar a influência de diferentes velocidades usando o dispositivo pistão para o ensaio de cisalhamento. Foram confeccionados 48 cilindros em resina composta microhíbrida (Solidex), divididos aleatoriamente em quatro grupos (n = 12). As amostras foram adaptadas ao dispositivo para o ensaio de cisalhamento e levadas a uma máquina de ensaios universal com uma célula de carga de 1000 Kg. Os ensaios foram realizados com quatro velocidades diferentes: grupo A: 0,5 mm/min; grupo B 1,0 mm/ min; grupo C: 1,5 mm/min e grupo D 2,0 mm/min. Os valores médios e desvios padrão obtidos, em Kgf, foram: grupo A: 66,31 ± 10,24; grupo B: 64,53 ± 20,40; grupo C: 75,23 ± 11,84 e grupo D: 66,62 ± 13,81. Os dados foram submetidos ao teste ANOVA (p = 0,13). Os resultados indicaram que não houve diferença estatisticamente significante entre os grupos A, B, C e D concluindo que se pode variar a velocidade neste tipo de ensaio, utilizando o dispositivo pistão, sem que os resultados fossem alterados


Subject(s)
Composite Resins , Materials Testing , Shear Strength
4.
ImplantNews ; 11(6): 763-768, 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-743135

ABSTRACT

O objetivo deste estudo foi avaliar a transmissão da carga mastigatória ao osso de suporte em próteses implantossuportadas em função do cantiléver, variando o tipo de pilar (Micro-Unite Ucla). A partir de dois modelos de poliuretano (norma ASTM F –1839), foram inseridos três implantes em cada, a uma distância de 8 mm, que conformaram os grupos: 1) implantes de hexágono externo e pilares Micro-Unit; 2) implantes de hexágono externo e pilares Ucla. Foram confeccionadas estruturas protéticas em resina acrílica ativada quimicamente sob cilindros com base de Co-Cr, que foram fundidas pela técnica convencional à brasagem. Foram fixados extensômetros no poliuretano entre os implantes e um na distal do implante mais próximo ao cantiléver. Em uma máquina de ensaio universal (2000RK – Kratos, São Paulo, Brasil), foi realizada a aplicação da carga de 150 N. A carga foi aplicada entre os implantes e no cantiléver nos intervalos de 5, 10, 15, 20 e 25 mm. Os dados obtidos foram analisados estatisticamente para cada extensômetro e levando em consideração a extensão do cantiléver. Quanto maior a extensão do cantiléver, maior a deformação superficial do osso ao redor do implante mais distal. A utilização do componente tipo Micro-Unit apresentou valores de deformação inferiores em relação ao Ucla.


Objectives: to evaluate transmission of masticatory loads according to different prosthetic implant abutment and cantilever lengths. Material and methods: two polyurethane models (ASTM F-1839) received 3 external hex dental implants 8 mm each apart divided into two groups: 1) Micro-Unit and, 2) Ucla. Metallic frameworks were prepared using acrylic resin and cast over CoCr prosthetic cylinders. Strain gauges were attached at the polyurethane-abutment interface and at the distal part of the implant near the cantilever. After, a 150 N load (2000 RK, Kratos, São Paulo, Brazil) was applied at 15, 20, and 25 mm from the most distal implant. Statistical analysis considered abutment type and cantilever lengths. Results: longer cantilevers generate more deformation in the distal implant. Deformation values at Micro-Unit were lower than at Ucla abutment type.


Subject(s)
Bite Force , Dental Implants , Dental Prosthesis, Implant-Supported
5.
ImplantNews ; 10(6a): 179-184, 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-761244

ABSTRACT

O presente estudo in vivo propôs avaliar a precisão de instalação de 23 implantes sem retalhos empregando guias cirúrgicos obtidos por estereolitografia em quatro pacientes com maxilas totalmente desdentadas. Após duplo escaneamento com tomografia computadorizada tipo cone-beam, o planejamento pré-cirúrgico foi realizado com o programa Procera. Depois da cirurgia, realizou-se a comparação entre as posições dos implantes planejados e executados através de tomografia computadorizada pós-operatória. Para comparação da posição e dos longos eixos das imagens dos implantes foram eleitos três pontos em cada implante planejado e executado: no centro do limite coronário (D1), no centro da porção central (D2), no centro do limite apical (D3). Assim, as distâncias e o ângulo (A1) formado entre os longos eixos dos implantes planejados e executados foram numericamente calculados. De acordo com a análise tomográfica, os implantes executados em relação aos implantes planejados apresentaram desvios médios de 0,72 mm para a posição D1; 0,98 mm para a posição D2; 1,45 mm para a posição D3; 1,92 graus para o ângulo A1. Concluiu-se que houve desempenho adequado para a utilização de protocolos de cirurgia guiada baseados no método empregado em associação com guias cirúrgicos produzidos pelo processo de estereolitografia. A transferência do planejamento protético-cirúrgico para o campo operatório foi considerada satisfatória, visto que viabilizou a instalação de implantes dentários nas situações propostas...


The aim of this in vivo study was to evaluate the placement accuracy of 23 dental implants with fl apless surgery using stereolithographic guides in four completely edentulous maxillary patients. After double scanning with cone beam computerized tomography (CBCT), the presurgical planning was performed using appropriate software (Procera). After surgery, executed and planned implant positions were compared using CBCT superimposing. Measurements were made at the center of three pre-selected points: coronal (D1), central (D2), and apical (D3) portions. Thus, the distances among points and the angle (A1) formed between the long axes of the planned/executed implants were calculated. Mean deviations were as the following: 0.72 mm at D1, 0.98 mm at D2, and 1.45 mm at D3 positions. The mean angular deviaton (A1) was 1.92 degrees. It was concluded that there was adequate performance with surgical guides produced by stereolithographic process. The transfer of prosthetic-surgical planning for the surgical area was considered satisfactory, since it allowed for implant placement in proposed situations...


Subject(s)
Humans , Cone-Beam Computed Tomography , Dental Implants , Stereotyping , Surgery, Computer-Assisted
6.
ImplantNews ; 9(6a): 88-93, 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-850998

ABSTRACT

O objetivo neste trabalho foi avaliar, por meio da extensometria, a distribuição de tensões ao redor de implantes em função dos diferentes locais para carregamento e configuração (linear e compensada). Para tanto, em um bloco de poliuretano, foram posicionados paralelos entre si e com uma configuração linear, implantes autorrosqueáveis de hexágono externo, com dimensões de 3,75 mm x 13 mm, a uma distância de 7 mm, de centro a centro. Em outro bloco, a fixação do meio foi deslocada em 2 mm para gerar uma configuração compensada (offset). Pilares protéticos Micro-unit, com 3 mm de cinta, foram instalados sobre as fixações. Com duas matrizes em aço inoxidável foram confeccionados dez enceramentos para cada bloco (n = 10). A seguir, esses padrões foram fundidos com uma liga de Co-Cr. Quatro extensômetros (strain gauges) foram colados na superfície superior de cada bloco, tangenciando a plataforma de cada fixação. Um carregamento de 30 kg durante dez segundos foi feito em cinco posições (A, B, C, D, E), sendo repetido três vezes para aquisição dos dados (em µɛ) pelo aparelho condicionador de sinais. Os dados obtidos foram submetidos a análise de variância (RM Anova) e teste de Tukey (p < 0,05). Como conclusão da análise dos resultados obtidos, pudemos observar que não houve diferença entre as configurações linear e compensada; havendo diferença estatisticamente significante para os locais de carregamento.


The aim of this study was to evaluate through strain gauge methods the load distribution around dental implants regarding different sites and configurations (linear and offset). Three cylindrical implants with external hexagon (3.75 mm x 13mm) connection were fixed parallel in a polyurethane model with 7 mm between their centers in a linear configuration. In another block, the middle implant was positioned 2 mm offset. After, micro-unit abutments (3 mm of metallic collar height) were tightened. Ten wax patterns were created for each block (n = 10) and cast in Cobalt-Chromium alloy. Four strain gauges were positioned on the upper surface of each polyurethane model around the implants. A 30 kg axial load was applied for 10 seconds in five positions (A, B, C, D, and E), with three repeated measurements for data aquisition (in µɛ) by the multichannel bridge machine. Data were submitted to Anova and Tukey´s test (p < 0.05). It was concluded that: 1) no difference was seen between the linear and offset configurations and 2) there was statistical significance for different loading sites


Subject(s)
Dental Implants , Dental Prosthesis
7.
Rev. ABO nac ; 19(4): 221-226, ago.-set. 2011. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-667478

ABSTRACT

Este estudo comparou a resistência de união da interface metal/resina compostacom diferentes tratamentos de superfície metálica. Material e Método: Trinta e trêspadrões de acrílico foram fundidos em CoCrMo com 25 X 3 X 0,5mm (ISO 9693).As amostras foram divididas em três grupos de acordo com os tratamentos de superfície:Grupo A – microesferas retentivas (150μm) + jateamento com partículasde 110μm de óxido de alumínio + primer para metal + três camadas de opaco pararesina composta; Grupo B (controle) – jateamento com partículas de 110μm de óxidode alumínio + primer para metal + três camadas de opaco para resina compostae o Grupo C – jateamento com partículas de 110μm de óxido de alumínio + duascamadas de opaco para porcelana + condicionamento ácido (10% ácido hidrofluorídrico)+ silano + agente de união, e após, usando uma matriz, uma camada deresina composta (8 x 3 x 1mm) foi aplicada. O ensaio de flexão de três pontos foiusado a uma velocidade constante de 0,5mm/min. Os dados foram submetidos àanálise estatística one way ANOVA e o teste Tukey (a = 5%). Resultados: A análisedescritiva dos dados estatísticos (kgf) para os Grupos A, B e C foram (3.167±0.483),(0.858±0.157) e (1.602±0.262) respectivamente. Os resultados mostraram que osvalores de resistência à flexão para todos os grupos diferiram estatisticamente(p<0.001) entre eles. Conclusão: Os resultados mostraram que os maiores valores deresistência de união foram obtidos com o tratamento de superfície usado no Grupo A.


The present study compared the bond strength of the composite resin-metal interfacewith different treatments on the metal. Material and Method: Thirty three acrylicpatterns were casted in CoCrMo with 25 X 3 X 0,5mm (ISO 9693). All metallicspecimens were divided in three groups according to the surfaces treatments: GroupA – retentive microballs (150μm) + sandblasting with aluminum oxide particles110μm (Al2O3) + metal primer + one layer of opaque resin; Group B (control)- sandblasting with aluminum oxide particles 110μm (Al2O3) + metal primer +three layers of opaque resin and Group C – sandblasting with aluminum oxide particles110μm (Al2O3) + two layers of opaque porcelain + acid conditioning (10%hydrofluoric acid gel for 4min) + silane + bonding agent. After, using a matrix,one layer of composite resin (8 x 3 x 1mm) was applied. The three-point flexuraltest was used at a cross-head speed of 0,5mm/min. These data were submitted toone way ANOVA and Tukey´s test (a = 5%). Results: Descriptive statistics data(kgf) for groups A, B and C were (3.167±0.483), (0.858±0.157) and (1.602±0.262)respectively. The results showed that mean flexural strength values for all groupsdiffer statistically (p <0.001) among them. The values of group A were significantlyhigher than the group B and C. Conclusion: The results showed highestvalues of bond strength were obtained with surface treatment used in A group.


Subject(s)
Composite Resins , Dental Materials , Physical Phenomena , Materials Testing/methods
8.
Odonto (Säo Bernardo do Campo) ; 17(34): 19-26, jul.-dez. 2009. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-542862

ABSTRACT

Objetivo: Comparar, no plano horizontal, as posições mandibulares determinadas por dois métodos de registro para determinação da posição de relação central (RC): inclinação da cabeça para trás (IC) os métodos guiado não forçado (GNF), em pacientes edêntulos. A hipótese nula é de que não haverá diferença entre os dois métodos. Material e Método: 20 pacientes desdentados totais foram selecionados para este estudo (n=20). Todos pacientes foram manipulados para posição de RC utilizando os métodos IC e GNF. A mensuração da posição de RC determinada por cada método foi registrada em um dispositivo extra-oral, cujas componentes foram fixados nos planos de orientação maxilar e mandibular. Para cada paciente, as duas posições de RC foram registradas no mesmo dispositivo extra-oral. Para mensurar as variações ânteroposteriores e laterais entre os pontos registrados por cada técnica, foi utilizado um projetor de perfil (Modelo 6C, Nikon/ USA). Os dados (mm) foram analisados estatisticamente utilizando o teste T (p<0.05) e o teste de correlação de Pearson. Resultados: A diferença entre a posição de RC obtida pelos métodos na posição ântero-posterior diferiu estatisticamente de zero (p=0.001) e que não houve diferença significante (p=0,479) quando comparada as posições de RC em relação à linha média: UHM (0,56±0,35mm) e IHB (0,65±0,52mm). Não foi observada correlação linear de Pearson entre as medidas lineares antero-posteriores e laterais dos métodos estudados (r=0,26; p=0,268>0,05). Conclusão: Pode-se concluir que método GNF gerou uma retrusão mandibular maior que o método IC.


Objective: To compare, in the horizontal plane, the mandibular positions determined by two methods for registering the centric relation (CR): inclination of the head backward (IHB) and unstrained hinging movement (UHM), in edentulous patients. The null hypothesis was that there is not difference between the two methods. Material and Methods: Twenty edentulous subjects were selected for this study (n=20). All patients were manipulated to CR position using the methods IHB and UHM. The CR measure of each method was registered in one extraoral device, which was fixed at the maxillary and mandibular record bases. For each patient, the two CR positions were registered in the same extraoral device. To measure the anteroposterior and lateral linear variations between the points registered for each technique, it was used a profile projector (Model 6C, Nikon/USA). The data (μm) were statistically analyzed using the Tukey test (p<0.05) and Pearson correlation test. Results: The difference between CR position obtained by the methods in anteroposterior position differed statically from zero (p=0.001) and that there was no significant difference (p=0.479) when compared the CR positions with the medium line: UHM (0.56±0.35ìm) and IHB (0.65±0.52ìm). It wasn’t observed Pearson linear correlation between the anteroposterior and lateral linear measures of the methods (r = 0.26; p = 0.268>0.05). Conclusion: It can be conclude that the method UHM presented a higher mandibular retrusion than the method IHB.


Subject(s)
Humans , Adult , Middle Aged , Mouth, Edentulous , Dental Occlusion , Mandible/anatomy & histology , Maxilla/anatomy & histology , Centric Relation
9.
RFO UPF ; 14(2): 143-148, maio-ago. 2009. tab
Article in Portuguese | LILACS | ID: lil-527863

ABSTRACT

O propósito do presente estudo foi avaliar o efeito do retorque na pré-carga de pilares protéticos fixados a implantes de conexão externa após diferentes tempos de espera. Trinta implantes de conexão externa (ScrewMaster®, Conexão) foram incluídos em resina acrílica. Sobre cada implante foi instalado um pilar protético(Ceraone®, Conexão) e, sobre estes, aparafusados os parafusos de fixação (30 Ncm), com o auxílio de um torquímetro digital. Os conjuntos implantes/pilares foram divididos em seis grupos, de acordo com os fatores "retorque" e "tempo de espera para coleta dos dados" (2, 5 e 10 min) (n = 5): aplicação de torque + coletade dados de destorque após 2 min (GA1), 5 min (GA2)e 10 min (GA3); aplicação de torque + retorque após10 min + coleta de dados de destorque após 2 min (GB1), 5 min (GB2) e 10 min (GB3). Os dados obtidos foram analisados estatisticamente pelos testes Anova (dois fatores) e Tukey (5%). As médias ± desvios-padrão dos valores de destorque (Ncm) observados para as condições experimentais foram: GA1: 25,39 ± 1,59; GA2: 22,91 ± 1,74; GA3: 21,95 ± 1,07; GB1: 28,16 ± 2,92; GB2: 21,97 ± 1,44; GB3: 21,21 ± 2,91. Verificou-se que os métodos de aplicação de torque (retorque) não influenciaram na perda de pré-carga para os grupos estudados (p = 0,6427 > 0,05) e que o tempo de espera para coleta dos dados do retorque afetou de maneira significativa os valores de pré-carga, sendo os maiores após 2 min da aplicação do torque (p = 0,0001 < 0,05). Conclui-se que houve perda significativa da pré-carga após 5 min da aplicação do torque.


The purpose of this study was to evaluate the effect of the retorquing on the preload of Ceraone abutment fixed to implants of external connection after different elapsed times for data collection. Thirty external hexagon implants (ConexãoTM, Brazil) were embedded in acrylic resin. After, the CeraoneTM abutments were fixed on each implant and the torque was applied (30Ncm). The sets of implant/abutment/screw were divided among six groups according to the factors “retorquing”and “elapsed times for data collection” (2, 5 and 10min) (n = 5): torque application + detorque data collection after 2min (GA1), 5min (GA2) and 10min (GA3) and torque application + new torque application (retorquing) after 10min + detorque data collection after 2min (GB1), 5min (GB2) and 10min (GB3). The data obtained were statistically analyzed by using the ANOVAtwo-way and Tukey test (5%). The means (± DP) of the detorque values (Ncm) observed for the experimental conditions were: GA1: 25.39 ± 1.59; GA2: 22.91± 1.74; GA3: 21.95 ± 1.07; GB1: 28.16 ± 2.92; GB2:21.97 ± 1.44; GB3: 21.21 ± 2.91. It was observed that the methods for torque application (retorquing) did not influence the lost of preload for the groups studied (p =0.6427 > 0.05) and that the elapsed time for retorquing data collection significantly affected the preload values,where the higher values were obtained after 2 min (p =0.0001 < 0.05) torque application. We concluded that regardless the methods used for torque application, there was a significant loss of preload after 5min torque application.


Subject(s)
Dental Implants , Torque
10.
Pesqui. bras. odontopediatria clín. integr ; 9(1): 113-117, jan.-abr. 2009.
Article in Portuguese | LILACS, BBO | ID: biblio-873941

ABSTRACT

Objetivo: Avaliar a resistência de união ao cisalhamento entre um material de revestimento estético e um metal submetido a três tratamentos de superfície. Método: Foram confeccionados trinta cilindros metálicos, com 5 mm de comprimento e 4mm de diâmetro cada, obtidos por meio de usinagem de barras de titânio comercialmente puro (Ticp). Os cilindros foram divididos em três grupos conforme o tratamento superficial (n=10): Grupo 1 - jateamento com óxido de alumínio (150 micrometros); Grupo 2 - Sistema Rocatec (3M/ESPE): jateamento com óxido de alumínio (Al2O3) 110 micrometros (Rocatec-pre powder) e com sílica (Rocatec-plus powder) + silano (Rocatec-Sil) e Grupo 3 - Sistema CoJet (3M/ESPE): jateamento com partículas de sílica 30 micrometros + Silano (ESPE Sil). Para confecção dos espécimes, foi aplicado sobre cada base metálica o sistema opaco (Sinfony Opaco, 3M ESPE/EUA) e posteriormente a resina composta para restauração indireta (Sinfony, 3M ESPE/EUA). Os espécimes foram armazenados em água destilada (37 graus Celsius / 24 horas) e submetidos ao ensaio de cisalhamento em máquina de ensaio universal (EMIC, modelo DL- 1000), com célula de carga de 500 Kgf, a uma velocidade constante de 0,5mm/min. Os dados obtidos (MPa) foram submetidos ao teste ANOVA (1 fator) e teste de Tukey (5%). Resultados: Observou-se que o grupo 1 (20,01 - 3,12) diferiu estatisticamente do grupo 2 (27,83 - 3,02) e do grupo 3 (26,91 - 3,65) que, entre si, não diferiram estatisticamente. Conclusão: O tratamento da superfície do Ticp com Rocatec ou CoJet gera maior resistência de união entre o Ticp e a resina Sinfony.


Objective: To assess the shear bond strength of an esthetic coatingmaterial and a metal subjected to three surface treatments. Methods: Thirty metallic cylinders (5 mm high x 4 mm diameter) were fabricated from machining of commercially pure titanium (CPTi) bars. The cylinders were assigned to three groups (n=10), according to the surface treatment: Group 1: 150- micrometrics aluminum oxide particle air abrasion; Group 2 - Rocatec system (3M/ESPE):110- micrometrics aluminum oxide particle air abrasion (Rocatec-pre powder) and silica air abrasion (Rocatec-plus powder) + silane (Rocatec- Sil); and Group 3 - CoJet system (3M/ESPE): 30- micrometrics silica particle air abrasion + silane (ESPE Sil). The specimens were fabricated by applying the opaque system (Sinfony Opaco, 3M/ESPE) followed by indirect composite resin (Sinfony, 3M ESPE/USA). After storage in distilled water at 37 degrees celsius for 24 hours, the specimens were tested in shear strength in a universal testing machine (EMIC, model DL- 1000) with a 500 kgf charge cell at 0.5 mm/min crosshead speed. The obtained data (MPa) were subjected to one-way ANOVA and Tukey's test at 5% significance level. Results: Group 1 (20.01 - 3.12) was statistically different from Group 2 (27.83 -3.02) and Group 3 (26.91 - 3.65). Groups 2 and 3 did not differ significantly from each other. Conclusion: The surface treatment of CPTi with Rocatec or CoJet produced greater bond strength between CPTi and Sinfony composite resin.


Subject(s)
Surface Properties , Air Abrasion, Dental/methods , Composite Resins/chemistry , Shear Strength , Titanium , Composite Resins , Analysis of Variance
11.
Pesqui. bras. odontopediatria clín. integr ; 8(3)set.-dez. 2008. graf, ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-537852

ABSTRACT

Objetivo: Avaliar a resistência à tração de copings de prata-estanho cimentados em dentina humana variando o cimento de fosfato e a superfície do preparo dentário. A hipótese nula foi que a superfície do preparo e o tipo cimento de fosfato não influenciam na resistência à tração dos copings metálicos.Método: Utilizando um torno mecânico, foram realizados preparados padrões para coroas totais em sessenta terceiros molares humanos, extraídos por indicação periodontal, sendo trinta preparos (Gr1) realizados com ponta montada diamantada (Komet, USA) e os outros trinta (Gr2) com broca carbide (Komet, USA). Para cada preparo foram confeccionados copings metálicos, os quais foram cimentados (carga axial: 5kg, tempo: 7 minutos) sobre os respectivos preparos dentários com três diferentes cimentos de fosfato de zinco (n=10): Gr1a/Gr2a- S.S. White, Gr1b/Gr2b - DFL e Gr1c/Gr2c - LS (Vigodent). Após 48 horas (estufa: 370C), os espécimes foram submetidos ao teste de resistência à tração (1mm/min; 50Kgf) em uma máquina de ensaio universal (EMIC). Os dados (Kgf) foram submetidos à análise estatística utilizando os testes ANOVA (dois fatores) e Tukey (5%).Resultados: Os valores obtidos para as condições experimentais foram: Gr1a (20,43±2,4Kgf), Gr1b (23,5±5,6Kgf), Gr1c (33,2±6,3Kgf), Gr2a (25,1±9,5Kgf), Gr2b (27,8±3,6Kgf) e Gr2c (32,5±8,3Kgf). Os resultados demonstraram que o efeito principal superfície do preparo não foi significante (p=0,1), mas analisando o tipo de cimento os grupos Gr1c e Gr2c foram superiores aos demais grupos (p=0,001). A hipótese nula foi rejeitada.Conclusão: O cimento LS gerou valores superiores de resistência à tração, independente do tipo de broca utilizada.


Subject(s)
Zinc Phosphate Cement , Dental Cements , Root Canal Filling Materials , Tensile Strength
12.
São José dos Campos; s.n; 2008. 105 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-524207

ABSTRACT

O objetivo deste estudo foi avaliar, por meio da extensometria, a distribuição de tensões ao redor de implantes em função dos diferentes locais para carregamento, tipo de coifa (plástica ou usinada) e configuração (linear e compensada). Para tanto, em um bloco de poliuretano, foram posicionados paralelos entre si e com uma configuração linear, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75 X 13mm, a uma distancia de 7mm, de centro a centro. Em um outro bloco a fixação do meio foi deslocada em 2mm para gerar uma configuração compensada (offset). Pilares protéticos Micro-unit, com 3mm de cinta foram instalados sobre as fixações. Com duas matrizes em aço inoxidável foram confeccionados 10 enceramentos para cada bloco, distribuídos da seguinte forma: 5 para coifa plástica e 5 para coifas usinadas (n=5). A seguir esses padrões foram fundidos com uma liga de Co-Cr. Quatro extensômetros (strain gauges) foram colados na superfície superior de cada bloco tangenciando a plataforma de cada fixação. Um carregamento de 30kg durante 10s foi feito em cinco posições (A, B, C, D, E), sendo repetido três vezes para aquisição dos dados (em με) pela aparelho condicionador de sinais. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Como conclusão da análise dos resultados obtidos pudemos observar que não houve diferença na utilização de coifas plásticas e usinadas, que não houve diferença entre as configurações linear e compensada, havendo diferença estatisticamente significante para os locais de carregamento.


Subject(s)
Dental Prosthesis , Dental Implants , Osseointegration
13.
J. appl. oral sci ; 15(3): 241-246, May-June 2007. ilus, graf
Article in English | LILACS | ID: lil-457290

ABSTRACT

OBJECTIVE: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. METHODS: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (î±= 5 percent). RESULTS: The microstrain values (µepsilon) were (mean±SD): GA: 263.7±109.07µepsilon, and GB: 193.73±78.83µepsilon. CONCLUSION: There was no statistical difference between the two methods studied.

14.
Odonto (Säo Bernardo do Campo) ; 15(29): 9-15, jan.-jun. 2007. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-518379

ABSTRACT

O objetivo deste trabalho foi avaliar a resistência à tração entre resinas de uso direto de três diferentes marcas comerciais, simulando reparos, utilizando ou não adesivo nesta interface. Para tanto foram confeccionadas 60 bases cônicas em resina composta (TPH) apresentando as seguintes dimensões: 5mm de comprimento, com uma base maior de 5mm e uma base menor de 3mm de diâmetro. Essas bases foram divididas aleatoriamente em 6 grupos. Sob estas bases foram aplicadas, com auxílio de uma matriz bi-partida de teflon, três resinas: TPH (Dentsply), InTen-S (Ivoclar), Filtek Supreme (3M-ESPE), com ou sem a utilização de um adesivo dentinário (Single Bond û 3M-ESPE), de maneira a obter amostras na forma de ampulheta. Após armazenamento destas amostras durante 7 dias à 37º C, estas foram submetidas ao ensaio de tração em uma máquina de ensaios universal com velocidade de 1,0 mm/ min e célula de carga de 500Kgf a qual carregou a amostra até que ocorresse sua fratura. Os dados obtidos (MPa) foram submetidos à Análise de Variância (ANOVA), e ao o teste de Tukey (5%). As médias e desvios padrão foram obtidos dos grupos sem e com adesivo, respectivamente: G1 - TPH 10,88±2,37, G2 - 17,59±3,42; G3 - Filtek 3,91±3,06, G4 - 14,02±4,34; G5 - Inten-S 5,32±1,30, G6 - 12,54±2,06. O teste estatístico de Tukey demonstrou que a utilização do adesivo levou a valores de tração estatisticamente maiores independentemente da marca comercial de resina composta, assim como a utilização da mesma resina da base, para o reparo.


This study evaluated the tensile bond strength between direct composite resins of three different brands, simulating repairs with or without utilization of adhesive at this interface. For that purpose, 60 tapered composite resin (TPH) bases were fabricated with the following dimensions: 5mm length, a larger base measuring 5mm in diameter and a smaller base with 3-mm diameter. These bases were randomly divided into 6 groups. Three resins were applied on these bases, with aid of a split Teflon matrix: TPH (Dentsply), InTen-S (Ivoclar), Filtek Supreme (3M-ESPE), with or without utilization of a dentin adhesive (Single Bond û 3M-ESPE), for achievement of hourglass-shaped specimens. After storage of specimens for 7 days at 37ºC, these were submitted to tensile testing in a universal testing machine EMIC û DL1000, at a crosshead speed of 1.0mm/min and a load cell of 500Kgf, which applied load on the specimen until occurrence of fracture. Data achieved (MPa) were submitted to Analysis of Variance (ANOVA) and to the Tukey test (5%). The means and standard deviations for groups with and without adhesive were as follows: G1 û TPH 10.88±2.37, G2 û 17.59±3.42; G3 û Filtek 3.91±3.06, G4 û 14.02±4.34; G5 û Inten-S 5.32±1.30, G6 û 12.54±2.06. The Tukey test demonstrated that utilization of the adhesive provided statistically higher tensile values, regardless of the composite resin brand, as well as repair with the same resin employed for the base.


Subject(s)
Composite Resins , Dental Materials , Dental Restoration, Permanent , Dentin-Bonding Agents , Tensile Strength
15.
Acta odontol. venez ; 45(3): 455-458, 2007. ilus
Article in Spanish | LILACS | ID: lil-502073

ABSTRACT

Electrodeposición es la deposición galvánica de la aleación de oro con 99% de pureza (24K) para el uso odontológico, teniendo como principio la electrólisis. Este sistema de electrodeposición permite la confeción de una cofia de oro con una excelente adaptación marginal. Puede ser fabricado con un espesor mínimo de 0,2mm haciendo posible realizar un desgaste menor en la preparación de pilares, y sobre esa fina infraestructura se puede aplicar una capa mayor de cerámica optimizando la estética cuando se compara con la fundición de estructuras convencionales. Hace posible la confección de coronas y prótesis parciales fijas. Las coronas metal-cerámicas confeccionadas por la técnica de electrodeposición otorgan una estética satisfactoria, debido a una apariencia mas natural y mejor calidad del color. Adicionalmente presenta características ventajosas como ausencia de corrosión y una excelente biocompatibilidad con los tejidos periodontales. Este trabajo muestra la confección de coronas metalocerámicas totales hechas con cofias por electrodeposición, teniendo como objetivo presentar una alternativa en prótesis parcial fija para los profesionales.


Electrodeposition is the galvanic deposition of the gold alloy with 99% of purity (24K) for the dentistry use, having like principle electrolysis. This electrodeposition system allows the preparation of pure gold coping with an excellent marginal fit. It can be made with a minimum thickness of 0,2mm doing possible to make a less teeth reduction, and on that fine infrastructure can be applied to a greater layer of ceramics optimizing the aesthetic when it is compared with the cast conventional copings. It is possible the preparation of unitary and fixed partial prostheses. The metal-ceramics crowns made by the electrodeposition technique present an aesthetic satisfactory, due to a natural appearance and better quality of the color. Additionally, it presents advantageous characteristics as corrosion absence and an excellent biocompatibility with periodontal tissues. This work shows the preparation of complete metal-ceramics crowns made with copings by electrodeposition, having as objective present an alternative in fixed partial prosthetics for the professionals.


Subject(s)
Humans , Female , Gold Alloys/chemistry , Denture, Partial, Fixed/methods , Electroplating/methods , Brazil , Esthetics, Dental
SELECTION OF CITATIONS
SEARCH DETAIL