Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Braz. J. Pharm. Sci. (Online) ; 53(2): e16083, 2017. tab, graf
Article in English | LILACS | ID: biblio-839479

ABSTRACT

ABSTRACT This study aimed to improve the water solubility of amiodarone hydrochloride (AMH) via inclusion complexes with β-cyclodextrin, methyl-β-cyclodextrin and 2-hydroxypropyl-β-cyclodextrin. Inclusion complexes were developed by physical mixture, coevaporation, spray-drying and freeze-drying. Solid state analysis was performed using X-ray powder diffraction, differential scanning calorimetry and scanning electronic microscopy. Thermodynamic studies demonstrate that the inclusion complexes of drug into different cyclodextrins were an exothermic process that occurred spontaneously. Water solubility and drug dissolution rates were significantly increased after the formation of inclusion complexes with the cyclodextrins evaluated in relation to the physical mixture and pure drug. The present study provides useful information for the potential application of complexation with amiodarone HCl. This may be a good strategy for the development of solid pharmaceutical dosage forms.


Subject(s)
Cyclodextrins/pharmacology , /analysis , Dissolution/analysis , Amiodarone/pharmacology , Solubility
2.
Braz. j. pharm. sci ; 51(4): 957-966, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778415

ABSTRACT

abstract Amiodarone HCl is an antiarrhythmic agent, which has low aqueous solubility and presents absorption problems. This study aimed to develop inclusion complexes containing hydrophilic carriers PEG 1500, 4000 and 6000 by fusion and kneading methods in order to evaluate the increase in solubility and dissolution rate of amiodarone HCl. The solid dispersion and physical mixtures were characterized by X-ray diffraction, FT-IR spectra, water solubility and dissolution profiles. Both methods and carriers increased the solubility of drug, however PEG 6000 enhanced the drug solubility in solid dispersion better than other carriers. Different media were evaluated for the solubility study, including distilled water, acid buffer pH 1.2, acetate buffer pH 4.5 and phosphate buffer pH 6.8 at 37 ºC. Based on the evaluation of the results obtained in the study phase solubility carriers PEG 4000 and PEG 6000 were selected for the preparation of the physical mixture and solid dispersion. All formulations were prepared at drug-carrier ratios of 1:1 to 1:10(w/w). The results of in vitro release studies indicated that the solid dispersion technique by fusion method in proportion of 1:10 (w/w) increased significantly the dissolution rate of the drug. X-ray diffraction studies showed reduced drug crystallinity in the solid dispersions. FT-IR demonstrated interactions between the drug and polymers.


resumo Cloridrato de amiodarona é um agente antiarrítmico que possui baixa solubilidade aquosa e apresenta problemas de absorção. Este estudo teve como objetivo desenvolver complexos de inclusão contendo carreadores hidrofílicos PEG 1500, 4000 e 6000 através dos métodos de fusão e amassamento para avaliar o aumento da solubilidade e taxa de dissolução do cloridrato de amiodarona. As dispersões sólidas e misturas físicas foram caracterizadas por difração de raios-X, espectroscopia no infravermelho com transformada de Fourier, solubilidade em água e perfis de dissolução. Ambos os métodos e carreadores aumentaram a solubilidade do fármaco, no entanto o PEG 6000 aumentou a solubilidade do fármaco na dispersão sólida mais que os outros carreadores. Diferentes meios foram avaliados para o estudo de solubilidade, incluindo água destilada, tampão ácido pH 1,2, tampão acetato pH 4,5 e tampão fosfato pH 6,8. Com base na avaliação dos resultados obtidos no estudo de solubilidade de fases, os carreadores PEG 4000 e PEG 6000 foram selecionados para a preparação das misturas físicas e dispersões sólidas. Todas as formulações foram preparadas nas razões fármaco-carreador de 1:1 a 1:10 (p/p). Os resultados de liberação in vitro que a técnica de dispersão sólida pelo método de fusão na proporção 1:10 (p/p) aumentou significativamente a taxa de dissolução do fármaco. Estudos de difração de raios-X mostraram redução da cristalinidade do fármaco na dispersão sólida. Análise por espectroscopia no infravermelho mostrou interações entre o fármaco e o carreador.


Subject(s)
Solubility , Dissolution/analysis , Amiodarone/analysis , X-Ray Diffraction , Anti-Arrhythmia Agents/pharmacokinetics
3.
Braz. j. pharm. sci ; 51(4): 823-832, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778418

ABSTRACT

abstract A method to ensure that an analytical method will produce reliable and interpretable information about the sample must first be validated, making sure that the results can be trusted and traced. In this study, we propose to validate an analytical high performance liquid chromatography (HPLC) method for the quantitation of meloxicam loaded PEGylated nanocapsules(M-PEGNC). We performed a validation study, evaluated parameters including specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. PEGylated nanocapsules were prepared by interfacial deposition of preformed polymer, and the particle size, polydispersity index, zeta potential, pH value and encapsulation efficiency were characterized. The proposed HPLC method provides selective, linear results in the range of 1.0-40.0 μg/mL; quantification and detection limits were 1.78 μg/mL and 0.59 μg/mL, respectively; relative standard deviation for repeatability was 1.35% and intermediate precision was 0.41% and 0.61% for analyst 1 and analyst 2, respectively; accuracy between 99.23 and 101.79%; robustness between 97.13 and 98.45% for the quantification of M-PEGNC. Mean particle diameters were 261 ± 13 nm and 249 ± 20 nm, polydispersity index was 0.15 ± 0.07 and 0.17 ± 0.06, pH values were 5.0 ± 0.2 and 5.2 ± 0.1, and zeta-potential values were -37.9 ± 3.2 mV e -31.8 ± 2.8 mV for M-PEGNC and placebo(B-PEGNC), respectively. In conclusion, the proposed analytical method is suitable for the quality control of M-PEGNC. Moreover, suspensions showed monomodal size distributions and low polydispersity index indicating high homogeneity of formulations with narrow size distributions, and appropriate pH and zeta potential. The extraction process was efficient for release of meloxicam from nanostructured systems.


resumo Para se assegurar que um método analítico produzirá informação confiável e interpretável sobre a amostra este deve ser inicialmente validado, tornando claro que os resultados podem ser confiados e rastreados. Neste estudo, propomos validar um método de cromatografia líquida de alta eficiência (CLAE) para a quantificação do meloxicam encapsulado em nanocápsulas PEGuiladas (M-PEGNC). Efetuamos a validação, avaliando parâmetros de especificidade, linearidade, limite de quantificação, limite de detecção, exatidão, precisão e robustez. As nanocápsulas PEGuiladas foram preparadas por deposição interfacial do polímero pré-formado e caracterizaram-se o tamanho da partícula, índice de polidispersão, potencial zeta, pH e eficiência de encapsulação. O método de CLAE proposto fornece resultados seletivos e lineares na faixa de 1,0-40,0 mg/mL; limites de quantificação e detecção de 1,78 mg/mL e 0,59 mg/mL, respectivamente; desvio padrão relativo para a repetibilidade de 1,35% e precisão intermediária de 0,41% e 0,61% para o analista 1 e analista 2, respectivamente; exatidão entre 99,23 e 101,79%; robustez entre 97,13 e 98,45% para a quantificação de M-PEGNC. Os diâmetros médios das partículas foram 261 ± 13 nm e 249 ± 20 nm; índice de polidispersão de 0,15 ± 0,07 e 0,17 ± 0,06, valores de pH de 5,0 ± 0,2 e 5,2 ± 0,1 e valores do potencial zeta de -37,9 ± 3,2 mV e -31,8 ± 2,8 mV para o M-PEGNC e o placebo(B-PEGNC), respectivamente. Concluindo, o método analítico proposto é adequado para o controle de qualidade do M-PEGNC. Além disso, suspensões mostraram distribuição de tamanho monomodal e baixo índice de polidispersão, indicando alta homogeneidade das formulações com distribuição estreita de tamanho, pH e potencial zeta apropriados. O processo de extração foi eficiente para a liberação do meloxicam dos sistemas nanoestruturados.


Subject(s)
Chromatography, High Pressure Liquid/methods , Nanocapsules , Polyethylene Glycols , Quality Control , Nanoparticles/analysis
4.
Braz. j. pharm. sci ; 50(2): 423-429, Apr-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-722195

ABSTRACT

The present study describes the development and validation of an in vitro dissolution method for evaluation to release diclofenac potassium in oral suspension. The dissolution test was developed and validated according to international guidelines. Parameters like linearity, specificity, precision and accuracy were evaluated, as well as the influence of rotation speed and surfactant concentration on the medium. After selecting the best conditions, the method was validated using apparatus 2 (paddle), 50-rpm rotation speed, 900 mL of water with 0.3% sodium lauryl sulfate (SLS) as dissolution medium at 37.0 ± 0.5°C. Samples were analyzed using the HPLC-UV (PDA) method. The results obtained were satisfactory for the parameters evaluated. The method developed may be useful in routine quality control for pharmaceutical industries that produce oral suspensions containing diclofenac potassium.


O presente estudo descreve o desenvolvimento e validação de um método de dissolução in vitro para avaliação da liberação de diclofenaco potássico suspensão oral. O teste de dissolução foi desenvolvido e validado de acordo com as diretrizes internacionais. Parâmetros como linearidade, especificidade, precisão e exatidão foram avaliados, bem como a influência da velocidade de rotação e a concentração de tensoativono meio. Depois de selecionar as melhores condições, o método foi validado usando o aparato 2 (pás), velocidade de rotação de 50 rpm, 900 mL de água com 0,3% de lauril sulfato de sódio (LSS) como meio de dissolução a 37,0 ± 0,5 ºC. As amostras foram analisadas pelo método de CLAE-UV (PDA). Os resultados obtidos foram satisfatórios para os parâmetros avaliados. O método desenvolvido pode ser útil na rotina de controle de qualidade para as indústrias farmacêuticas que produzem suspensões orais contendo diclofenaco potássico.


Subject(s)
Diclofenac/classification , Chromatography, High Pressure Liquid/methods , Validation Study , Quality Control , Dissolution/methods
5.
Article in Portuguese | LILACS | ID: lil-677944

ABSTRACT

As farmácias magistrais têm se mostrado uma alternativa quando o paciente procura medicamentos com doses personalizadas ou custos mais baixos, o que resultou em um crescente aumento pela procura de medicamentos manipulados. Porém, apesar das vantagens, estes medicamentos não passam por um rígido controle de qualidade, o que pode colocar o tratamento do paciente em risco. Este trabalho teve como objetivos validar metodologia analítica e avaliar a qualidade das cápsulas de cloridrato de metformina manipuladas por sete farmácias de Santa Maria – RS. O método validado mostrou-se seletivo, linear, preciso, exato e robusto, podendo ser utilizado para a determinação quantitativa de cloridrato de metformina em cápsulas. As cápsulas produzidas pelas farmácias A, B, D, F e G cumpriram com os requisitos mínimos de controle de qualidade e as cápsulas manipuladas pelas farmácias C e E foram reprovadas nos testes de doseamento e uniformidade de doses unitárias.


Compounding pharmacies have proved a useful alternative when patients look for drugs fitted to their needs in dose number and size, or for less expensive drug forms, leading to an increasing demand for compounded drugs. However, despite the advantages, these drugs do not always go through a strict quality control, which may be detrimental to patient care. The aim of the present study is to validate an analytical method and use it to assess the quality of metformin hydrochloride capsules obtained from seven different compounding pharmacies in Santa Maria, RS (Brazil). The validated method proved to be selective, linear, precise, accurate and robust and can be used for the quantitative determination of metformin hydrochloride in capsules. The capsules compounded by pharmacies A, B, D, F and G met the minimum requirements of quality control, while those from pharmacies C and E failed in the assays of dose and uniformity of dosage units.


Subject(s)
Capsules/chemistry , Drug Compounding , Metformin , Quality Control
6.
Braz. j. pharm. sci ; 47(2): 339-350, Apr.-June 2011. ilus, tab
Article in English | LILACS | ID: lil-595822

ABSTRACT

This paper describes the studies performed with the candidate Certified Reference Material (CRM) of captopril, the first CRM of an active pharmaceutical ingredient (API) in Brazil, including determination of impurities (organic, inorganic and volatiles), homogeneity testing, short- and long-term stability studies, calculation of captopril content using the mass balance approach, and estimation of the associated measurement uncertainty.


Este artigo descreve os estudos realizados com o candidato a Material de Referência Certificado (MRC) de captopril, primeiro MRC de fármacos no Brasil, incluindo a determinação de impurezas (orgânicas, inorgânicas e voláteis), testes de homogeneidade, testes de estabilidade de curta e longa duração, cálculo do teor de captopril por balanço de massa e estimativa da incerteza de medição associada ao valor certificado.


Subject(s)
Captopril/analysis , Captopril/pharmacology , Captopril/chemistry , Pharmaceutical Preparations/standards , Chromatography, High Pressure Liquid , Drug Contamination/statistics & numerical data , Evaluation Studies as Topic , Quality Control , Reference Standards
7.
Braz. j. pharm. sci ; 47(2): 351-362, Apr.-June 2011. ilus, tab
Article in English | LILACS | ID: lil-595823

ABSTRACT

This paper describes the validation of a reversed-phase high performance liquid chromatography method (RP-HPLC) with diode array detection (DAD) for determination of related substances (impurities from organic synthesis and degradation products) of captopril according to the Brazilian Pharmacopeia IV. The aim of this study was to guarantee the method accuracy for quantification of related substances, an essential requisite to determine, using the mass balance approach, the captopril content in the first Brazilian certified reference material (CRM) of an active pharmaceutical ingredient (API), developed by Inmetro. The captopril instability in solution is discussed and the captopril content determined by mass balance is compared to the results from titration and differential scanning calorimetry (DSC).


Este artigo descreve a validação de método de cromatografia líquida de alta eficiência em fase reversa (CLAE-RP) com detector de fotodiodos (DAD) para determinação de substâncias relacionadas (impurezas orgânicas de síntese e produtos de degradação) de captopril segundo Farmacopéia Brasileira IV ed. Este estudo teve como objetivo garantir que o método é capaz de quantificar com exatidão o teor de substâncias relacionadas, um requisito essencial para que o teor de captopril seja determinado por balanço de massa no primeiro material de referência certificado (MRC) de fármacos brasileiro, o qual foi desenvolvido pelo Inmetro. A instabilidade do captopril em solução é discutida em detalhes e o teor de captopril determinado por balanço de massa é comparado com aqueles obtidos por titulação e por calorimetria exploratória diferencial (DSC).


Subject(s)
Captopril/analysis , Captopril/pharmacology , Captopril/isolation & purification , Chemical Compounds/methods , Chromatography, High Pressure Liquid/methods , Diagnosis/analysis , Drug Contamination , Quality Control , Chemistry, Pharmaceutical/methods
SELECTION OF CITATIONS
SEARCH DETAIL