Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Arq. bras. cardiol ; 119(6): 931-937, dez. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1420121

ABSTRACT

Resumo Fundamento A estenose coronária pode ser causada por de novo aterosclerose, reestenose intra-stent e neoaterosclerose intra-stent, três entidades que se desenvolvem a partir de diversos meios fisiopatológicos. Objetivos Este estudo tem como objetivo investigar, por meio da tomografia de coerência óptica (OCT), se as lesões coronarianas relacionadas a esses processos diferem em seu perfil inflamatório local. Métodos Análise retrospectiva de pacientes com lesões coronárias diagnosticadas ou suspeitas que realizaram exames de OCT por motivos clínicos. Macrófagos e neovascularização intraplaca foram avaliados por OCT e utilizados como marcadores de inflamação local. O nível de significância < 0,05 foi adotado como estatisticamente significante. Resultados Das 121 lesões, 74 eram de novo , 29 eram reestenose e 18 eram neoaterosclerose. Neovascularização foi encontrada em 65,8% das de novo , 10,3% na reestenose e 94,4% na neoaterosclerose (p<0,01 para todos). O volume de neovascularização foi diferente entre os tipos de lesão (950 vs. 0 vs. 6.220, respectivamente [valores medianos em 1000 x µm 3 /mm]; p<0,01 para todos), sendo significativamente maior na neoaterosclerose e menor na reestenose. A presença de macrófagos diferiu entre as lesões (95,9% em de novo vs. 6,9% em reestenose vs. 100% em neoaterosclerose [p<0,01 para todos]). Além disso, a intensidade da infiltração macrofágica foi diferente entre os tipos de lesão (2,5 vs. 0,0 vs. 4,5, respectivamente [valores medianos do escore de macrófagos]; p<0,01 para todos), significativamente maior na neoaterosclerose e menor na reestenose. Conclusões Quando comparados pela OCT coronariana, de novo , reestenose intra-stent e neoaterosclerose apresentaram fenótipos inflamatórios marcadamente diferentes.


Abstract Background Coronary stenosis can be caused de novo atherosclerosis, in-stent restenosis, and in-stent neoatherosclerosis, three entities that develop from a diverse pathophysiological milieu. Objective This study aims to investigate, using optical coherence tomography (OCT), whether or not coronary lesions related to these processes differ in their local inflammatory profile. Methods Retrospective analysis of patients with diagnosed or suspected coronary lesions who had undergone OCT imaging for clinical reasons. Macrophage and intra-plaque neovascularization were assessed by OCT and used as surrogates of local inflammation. A significance level of < 0.05 was adopted as statistically significant. Results From the 121 lesions, 74 were de novo, 29 were restenosis, and 18 were neoatherosclerosis. Neovascularization was found in 65.8% of de novo, 10.3% in restenosis, and 94.4% in neoatherosclerosis (p<0.01 for all). The volume of neovascularization was different among lesion types (950 vs. 0 vs. 6220, respectively [median values in 1000 x µm3/mm]; p<0.01 for all), which were significantly higher in neoatherosclerosis and lower in restenosis. The presence of macrophages differed among the lesions (95.9% in de novo vs. 6.9% in restenosis vs. 100% in neoatherosclerosis [p<0.01 for all]). Moreover, the intensity of macrophagic infiltration was different among lesion types (2.5 vs. 0.0 vs. 4.5, respectively [median values of macrophage score]; p<0.01 for all), significantly higher in neoatheroscleosis and lower in restenosis. Conclusion When compared using coronary OCT, de novo atherosclerosis, in-stent restenosis, and neoatherosclerosis presented markedly different inflammatory phenotypes.

2.
Arq. bras. cardiol ; 118(6): 1085-1096, Maio 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1383690

ABSTRACT

Resumo Fundamento: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. Objetivo: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. Método: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. Resultados: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. Conclusão: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.


Abstract Background: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. Objective: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. Methods: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. Results: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. Conclusion: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.

4.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 29(4): 350-355, out.-dez. 2019. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1047208

ABSTRACT

Cardiologistas intervencionistas são expostos a riscos ocupacionais, que incluem a ocorrência de catarata, malignidades e lesões ortopédicas. A intervenção coronária percutânea (ICP) assistida por robô pode reduzir esses riscos ocupacionais, além de oferecer grande precisão e controle fino da manipulação de dispositivos médicos, podendo conferir benefícios ao paciente. O objetivo desta revisão é descrever as vantagens e as limitações da ICP assistida por robótica, os dados clínicos mais recentes e as futuras aplicações da tecnologia robótica


Interventional cardiologists are exposed to occupational hazards, including cataract, malignancies and orthopedic injuries. Robot-assisted percutaneous coronary intervention (PCI) can reduce these occupational hazards and offer great precision and fine-grained control over the handling of medical devices, potentially benefitting the patients. The aim of this review is to describe the advantages and limitations of robot-assisted PCI, the latest clinical data and future applications of robotic technology


Subject(s)
Robotics/methods , Angioplasty/methods , Percutaneous Coronary Intervention/methods , Technology , Occupational Risks , Cardiology , Stents
5.
Res. Biomed. Eng. (Online) ; 32(1): 35-43, Jan.-Mar. 2016. tab, graf
Article in English | LILACS | ID: biblio-829457

ABSTRACT

Abstract Introduction: Intravascular optical coherence tomography (IVOCT) is an in-vivo imaging modality based on the introduction of a catheter in a blood vessel for viewing its inner wall using electromagnetic radiation. One of the most developed automatic applications for this modality is the lumen area segmentation, however on the evaluation of these methods, the slices inside bifurcation regions, or with the presence of complex atherosclerotic plaques and dissections are usually discarded. This paper describes a fully-automatic method for computing the lumen area in IVOCT images where the set of slices includes complex atherosclerotic plaques and dissections. Methods The proposed lumen segmentation method is divided into two steps: preprocessing, including the removal of artifacts and the second step comprises a lumen detection using morphological operations. In addition, it is proposed an approach to delimit the lumen area for slices inside bifurcation region, considering only the main branch. Results Evaluation of the automatic lumen segmentation used manual segmentations as a reference, it was performed on 1328 human IVOCT images, presenting a mean difference in lumen area and Dice metrics of 0.19 mm2 and 97% for slices outside the bifurcation, 1.2 mm2 and 88% in the regions with bifurcation without automatic contour correction and 0.52 mm2 and 90% inside bifurcation region with automatic contour correction. Conclusion This present study shows a robust lumen segmentation method for vessel cross-sections with dissections and complex plaque and bifurcation avoiding the exclusion of such regions from the dataset analysis.

6.
In. Kalil Filho, Roberto; Fuster, Valetim; Albuquerque, Cícero Piva de. Medicina cardiovascular reduzindo o impacto das doenças / Cardiovascular medicine reducing the impact of diseases. São Paulo, Atheneu, 2016. p.43-63.
Monography in Portuguese | LILACS | ID: biblio-971527
8.
Rev. bras. cardiol. invasiva ; 20(2): 133-139, abr.-jun. 2012. tab
Article in English, Portuguese | LILACS | ID: lil-649563

ABSTRACT

Introdução: Magic TouchTM é um balão recoberto com nanopartículas carreadoras de sirolimus. Objetivamos encontrar a dose excipiente: fármaco com a maior capacidade de inibição da proliferação neointimal 28 dias após o uso desse balão pós-implante de stent não-farmacológico em artérias coronárias porcinas. Métodos: Foram avaliados 14 porcos com implante coronário de stent não-farmacológico seguido por dilatação(60 segundos) com balões com relação excipiente: sirolimus 1:1, 0,5:1, 0,25:1 e 1:0 ou balão controle. Após 28 dias a hiperplasia neointimal foi estudada por tomografia de coerência óptica e histopatologia. Resultados: A hiperplasia neointimal porcentual (%) avaliada pela tomografia de coerência óptica e pela histomorfometria foi de 32,2 e 35,1, 28,1 e 33,4, 17,3 e20,9, 28,6 e 30,2, e 37,9 e 42,3 nos grupos excipiente: sirolimus 0,25:1, 0,5:1, 1:1, 1:0 e balão controle, respectivamente (P = 0,03 para excipiente: sirolimus 1:1 vs. balão controle). A espessura (mm) da neoíntima inter-hastes foi de 0,23, 0,30, 0,16, 0,24 e 0,30 nos grupos excipiente: sirolimus 0,25:1,0,5:1, 1:1, 1:0 e balão controle, respectivamente (P < 0,01para excipiente: sirolimus 1:1 vs. balão controle). Os escores de inflamação, injúria e deposição de fibrina foram baixos e sem diferenças significantes entre os grupos. Conclusões: Ocorreu gradual aumento da eficácia inibitória da proliferação neointimal à medida que a concentração do excipiente aumentou; amenor eficácia ocorreu com a formulação excipiente: sirolimus 0,25:1 e a mais intensa inibição foi observada com a formulação excipiente: sirolimus 1:1, a qual reduziu significantemente a proliferação neointimal em comparação com o grupo controle, com baixos índices de inflamação e injúria.


Subject(s)
Animals , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon, Coronary , Animal Experimentation , Coronary Restenosis/complications , Sirolimus/administration & dosage , Stents
9.
Rev. bras. cardiol. invasiva ; 20(2): 161-165, abr.-jun. 2012. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-649567

ABSTRACT

Introdução: Atualmente são ainda desconhecidas as implicaçõesprognósticas tardias da doença arterial coronária (DAC) estável em pacientes jovens. O objetivo deste trabalho foiavaliar o prognóstico de pacientes adultos jovens com diagnóstico de DAC estável, tratados por meio de intervenção coronária percutânea (ICP) e acompanhados por até 10 anos.Métodos: A população do estudo foi constituída por pacientes jovens (idade abaixo do 10o percentil) de um grupo de 1.394 pacientes consecutivos tratados para DAC estável por via percutânea.As características dos pacientes foram coletadas prospectivamente. Após o procedimento foi realizado seguimentoambulatorial, com análise do prontuário hospitalar eletrônico e contato telefônico, quando necessário. O desfecho primário foi a mortalidade geral e o desfecho secundário, a mortalidade cardiovascular. Resultados: Foram selecionados 140 pacientes, com média de idade de 43,7 ± 4 anos (mínimo de 26 anos e máximo de 48 anos), predominantemente do sexo masculino (76,4%). Diabetes melito estava presente em aproximadamenteum quinto dos pacientes e metade apresentava infarto prévio. Os pacientes foram seguidos por uma média de 94,6 ±36,2 meses e a mortalidade geral no seguimento de 10 anos foi de 6%, com mortalidade cardíaca de 5,3%. Todos ospacientes que morreram obtiveram sucesso no procedimento inicial e apenas um dos casos não apresentava infarto prévio. Conclusões: Em nossa prática clínica, pacientes jovens com coronariopatia crônica tratados com ICP mostraram ter bom prognóstico tardio.


Subject(s)
Humans , Male , Female , Middle Aged , Angioplasty/methods , Angioplasty , Coronary Disease/complications , Coronary Disease/diagnosis , Risk Factors , Prognosis
10.
Rev. bras. cardiol. invasiva ; 19(3): 298-302, set. 2011. tab, ilus, graf
Article in Portuguese | LILACS | ID: lil-607267

ABSTRACT

Introdução: A imagem de placas ateroscleróticas em território extracardíaco, por meio do ultrassom das carótidas, tem sido proposta como forma indireta para estimar o risco coronário. Considerou-se a hipótese de que a avaliação isolada do tronco da artéria coronária esquerda (TCE) pudesse predizer diretamente a carga aterosclerótica no restante da árvore coronária. Métodos: O estudo incluiu pacientes com diagnóstico de doença arterial coronária com indicação de intervenção coronária percutânea (ICP), que apresentassem TCE sem estenose significativa. Durante a ICP, realizou-se ultrassom intracoronário (USIC) do TCE e das três artérias coronárias em que foram mensuradas as áreas luminal, da membrana elástica externa e da placa e a carga de placa em cada vaso. Resultados: Foram incluídos 17 pacientes com média de idade de 56 ± 8,9 anos, 71% do sexo masculino e 41% diabéticos. Apesar de nenhum paciente apresentar estenose significativa no TCE à angiografia ou ao ultrassom, observou-se, no TCE, evidência de aterosclerose com área de placa de 8,4 ± 2,7 mm2 e carga de placa de 33,5 ± 8,9%. Correlação significativa entre o TCE e o restante das coronárias foi observada para todos os parâmetros ultrassonográficos avaliados: área luminal (r = 0,5), área da membrana elástica externa (r = 0,7), área de placa (r = 0,6) e carga de placa (r = 0,4). Conclusões: Nesta análise piloto, a carga aterosclerótica coronária global pôde ser estimada a partir da avaliação isolada do TCE por USIC. Essa associação é relevante para a construção de escores de predição de risco coronário, como marcador substituto da carga de aterosclerose global da árvore coronária.


BACKGROUND: Non-cardiac atherosclerotic imaging, including carotid ultrasound, has been proposed as an indirect way to estimate coronary risk. The authors hypothesize that the isolated assessment of the left main coronary artery (LMCA) could predict the atherosclerotic burden in the remainder of the coronary tree. METHODS: The study included patients with a diagnosis of coronary artery disease with an indication for percutaneous coronary intervention (PCI), without significant LMCA stenosis. During PCI, LMCA and three-vessel intravascular ultrasound (IVUS) examination was performed and the lumen area, external elastic membrane area, plaque area, and plaque burden were measured. RESULTS: A total of 17 patients were included with mean age of 56 ± 8.9 years, 71% male, and 41% diabetics. Although none of the patients had LMCA stenosis by angiography or IVUS, evidence of atherosclerosis was observed with a plaque area of 8.4 ± 2.7 mm² and plaque burden of 33.5 ± 8.9%. A significant correlation between the LMCA and the rest of the coronary arteries was observed for all IVUS parameters: lumen area (r = 0.5), external elastic membrane area (r = 0.7); plaque area (r = 0.6), and plaque burden (r = 0.4). CONCLUSIONS: In this pilot study, the coronary atherosclerotic burden could be estimated from the isolated assessment of the LMCA by IVUS. Such an association is relevant for the development of future coronary risk scores, as a surrogate marker of the global coronary tree atherosclerotic burden.


Subject(s)
Humans , Male , Female , Middle Aged , Coronary Artery Disease/complications , Coronary Artery Disease/diagnosis , Ultrasonography/methods , Ultrasonography , Risk Factors
11.
Rev. bras. cardiol. invasiva ; 19(3): 303-307, set. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-607268

ABSTRACT

Introdução: A doença arterial coronária (DAC) é sabidamente difusa, podendo acometer múltiplos segmentos arteriais. No entanto, quando se analisa a angiografia coronária, é comum a concomitância, em um mesmo paciente, da presença de lesão em um segmento e da ausência de obstrução em outros. Por se tratar de um luminograma, a angiografia apresenta limitações para o diagnóstico da DAC. Neste estudo utilizou-se o ultrassom intracoronário com histologia virtual (USIC-HV) para avaliar a presença e a composição de placas ateroscleróticas em segmentos angiograficamente normais e com lesões em pacientes com DAC estabelecida. Métodos: No total, 17 pacientes com DAC obstrutiva encaminhados para realização de angioplastia foram submetidos a USIC-HV dos três grandes vasos epicárdicos. Após análise minuciosa da angiografia, foram selecionados 32 segmentos angiograficamente normais, os quais foram comparados a outros 19 segmentos coronários com estenose luminal > 70%. Resultados: A carga de placa média em segmentos sem lesão angiográfica foi de 47,3 ± 15,1%, enquanto em segmentos com estenose angiográfica foi de 76,2 ± 8,8% (P < 0,01). A composição da placa diferiu entre os segmentos. Placas nos segmentos angiograficamente normais apresentavam maior componente fibrolipídico (17 ± 11% vs. 11,4 ± 12%; P = 0,045) e menor componente necrótico (13,1 ± 13% vs. 20,2 ± 12%; P = 0,03). Conclusões: Nesta análise piloto, em pequeno grupo de pacientes portadores de DAC, observou-se que segmentos angiograficamente normais frequentemente apresentam placa aterosclerótica. A composição da placa em segmentos angiograficamente normais, entretanto, diferiu daquela em segmentos com lesão, sugerindo a coexistência de estágios distintos do processo aterosclerótico em um mesmo paciente.


BACKGROUND: Coronary artery disease (CAD) is known to be diffuse and can affect multiple arterial segments. However, findings of concomitant lesions in a single segment and no obstructions in other segments of the same patient are not unusual when assessing coronary angiographies. Because it is a luminogram, angiography has limitations for the diagnosis of CAD. In this study, intravascular ultrasound and virtual histology (IVUS-VH) were used to assess the presence and composition of atherosclerotic plaques in angiographically normal segments and in segments with lesions of patients with established CAD. METHODS: A total of 17 patients with obstructive CAD referred for angioplasty were submitted to IVUS-VH of the three major epicardial coronary arteries. After careful angiographic analysis, 32 angiographically normal segments were selected and compared to 19 segments with luminal stenosis > 70%. RESULTS: Mean plaque burden in angiographically normal segments was 47.3 ± 15.1%, whereas in segments with angiographic stenosis it was 76.2 ± 8.8% (P < 0.01). Plaque composition differed among segments. Plaques in angiographically normal segments had higher percentage of fibrofatty component (17 ± 11% vs. 11.4 ± 12%; P = 0.045) and lower percentage of necrotic component (13.1 ± 13% vs. 20.2 ± 12%; P = 0.03). CONCLUSIONS: In this pilot study, in a small group of patients with CAD, it was observed that angiographically normal segments often have atherosclerotic plaque. However, plaque composition was different in angiographically normal segments and those with angiographic stenosis, suggesting the coexistence of distinct stages of the atherosclerotic process in the same patient.


Subject(s)
Humans , Male , Female , Middle Aged , Angiography/methods , Angiography , Coronary Artery Disease , Risk Factors , Stents
12.
Rev. bras. cardiol. invasiva ; 19(2): 138-144, jul. 2011. tab, ilus
Article in Portuguese | LILACS | ID: lil-595226

ABSTRACT

Introdução: Está em desenvolvimento em nosso meio o stent InspironTM, um stent nacional metálico de cobalto-cromorecoberto com uma mistura de polímeros bioabsorvíveis exclusivamente em sua face abluminal e com liberação de sirolimus. O objetivo deste estudo foi comparar, em um modelo experimental, os achados da tomografia de coerência óptica dos stents InspironTM e BioMatrixTM. Métodos: Os stents foram implantados em artérias coronárias porcinas. Cada indivíduo recebeu os dois tipos de stent, um em cada artéria (artérias descendente anterior e circunflexa), e após 28 dias foi realizado novo estudo angiográfico e empregada a tomografia de coerência óptica para avaliação da hiperplasia neointimal. Resultados: Sete porcos receberam 7 stents InspironTM e 7 stents BioMatrixTM. O diâmetro de referência dos vasos tratados foi de 2,16 + 0,37 mm e a relação balão de implante do stent/artéria foi de 1,17 + 0,16 atm, sem diferença entre os grupos. A perda tardia intrastent foi de 0,53 + 0,56 mm e de 0,32 + 0,37 mm (P = 0,43) para os stents InspironTM e BioMatrixTM, respectivamente. Ocorreu um caso de reestenose angiográfica no grupo stent InspironTM (14% vs. 0; P = 0,2). A tomografia de coerência óptica evidenciou área neointimal intrastent no stent InspironTM de 1,61 + 0,57 mm² e no stent BioMatrixTM de 1,36 + 0,66 mm² (P = 0,47). A área neointimal porcentual foi de 31% no stent InspironTM vs. 23% no stent BioMatrixTM (P = 0,21). Conclusões: Após 28 dias de implante em artérias coronárias porcinas o stent InspironTM apresentou grau de hiperplasia neointimal intrastent semelhante ao do stent BioMatrixTM.


Background: InspironTM, a chrome-cobalt sirolimus-eluting stent covered by a mixture of bioabsorbable polymers on its abluminal side is being developed in Brazil. Our objective was to compare in an experimental study the findings ofoptical coherence tomography for the InspironTM and BioMatrix™ stents. Methods: Stents were implanted in porcine coronary arteries. Each individual received two types of stents, one in each artery (left anterior descending and left circumflex artery). After 28 days, a new angiography was performed and optical coherence tomography was used to assess neointimal hyperplasia. Results: Seven Inspiron™ stents and 7 BioMatrixTM stents were implanted in 7 domestic pigs. The reference diameter of the treated vessels was 2.16 + 0.37 mm and the balloon to artery ratio was 1.17 + 0.16 atm, with no statisticaldifference between groups. In-stent late loss was 0.53 + 0.56 mm and 0.32 + 0.37 mm (P = 0.43) for the InspironTMand BioMatrixTM stents, respectively. There was one case of angiographic restenosis in the InspironTM group (14% vs 0; P = 0.2). Optical coherence tomography showed an instent neointimal area of 1.61 + 0.57 mm² for the InspironTM stent and 1.36 + 0.66 mm² for the BioMatrixTM stent (P = 0.47). The percentage of neointimal area was 31% for the InspironTM stent vs 23% for the BiomatrixTM stent (P = 0.21). Conclusions: Twenty-eight days after implantation in porcine coronaryarteries the InspironTM stent showed a similar degree of neointimal hyperplasia as the BiomatrixTM stent.


Subject(s)
Animals , Drug-Eluting Stents , Tomography, Optical Coherence/methods , Tomography, Optical Coherence
13.
Rev. bras. cardiol. invasiva ; 19(1): 47-52, mar. 2011.
Article in Portuguese | LILACS | ID: lil-591718

ABSTRACT

Introdução: Há alguns anos estudos demonstraram que stents de cromo-cobalto, com hastes mais finas, reduziram de forma expressiva a reestenose coronária, comparativamente aos stents convencionais de aço inoxidável disponíveis na época. Desde então, stents com hastes < 100 µm e diferentes ligas metálicas estão disponíveis para uso clínico. O objetivo deste estudo foi avaliar a existência de diferenças nos resultados clínicos de pacientes submetidos a intervenção coronária percutânea (ICP) com stents de hastes finas e diferentes ligas metálicas. Métodos: Registro unicêntrico, em que foram comparados os resultados de pacientes submetidos a ICP com stent de aço inoxidável (n = 135) vs. stent de cromo-cobalto (n = 181). O desfecho primário foi a ocorrência de eventos cardíacos adversos maiores (ECAM), definidos pela ocorrência de óbito, infarto agudo do miocárdio (IAM) ou revascularização do vaso-alvo (RVA) no seguimento tardio. Resultados: A média de idade dos pacientes foi de 64 ± 11 anos, com 32,6% de diabéticos e 65,5% com síndrome coronária aguda à admissão, sem diferenças na maioria das características clínicas e angiográficas avaliadas entre os grupos. Na comparação das características do procedimento, a estratégia de implante direto do stent foi mais frequente no grupo cromo-cobalto (30,3% vs. 40,2%; P = 0,04). Ao final de mediana de 500 dias de seguimento, não houve diferenças significativas entre os grupos para a ocorrência de ECAM (15,5% vs. 16,5%; P = 0,6), óbito (4,6% vs. 6,8%; P = 0,29), IAM (2,7% vs. 4,1%; P = 0,41) ou RVA (10,4% vs. 10,1%; P = 0,97). Conclusões: Nessa população do mundo real os stents de cromo-cobalto apresentaram eficácia e segurança semelhantes às dos stents de aço inoxidável, porém com menor necessidade de instrumentação coronária.


Background: Years ago studies demonstrated that the use of cobalt-chromium stents with thinner struts significantly reduced coronary restenosis when compared to conventional stainless steel stents available at the time. Since then, stents with struts < 100 μm and different metal alloys are available for clinicaluse. The objective of this study was to assess differences in the clinical outcomes of patients undergoing percutaneous coronary intervention (PCI) with thin strut stents and differentmetal alloys. Methods: Single center registry comparing the results of patients undergoing PCI with stainless steel stents (n = 135) vs. cobalt-chromium bare metal stents (n = 181).The primary endpoint was the occurrence of major adverse cardiac events (MACE), defined by death, acute myocardial infarction (AMI) or target vessel revascularization (TVR) in thelate follow-up. Results: Mean patient age was 64 ± 11 years, 32.6% were diabetic and 65.5% had acute coronary syndrome at admission, with no differences for most of the clinical andangiographic characteristics assessed between groups. The use of direct stenting was more frequent in the cobalt-chromium group (30.3% vs. 40.2%; P = 0.04). After a median of500 days of follow up, there was no statistically significant difference between groups for the occurrence of MACE (15.5% vs. 16.5%; P = 0.6), death (4.6% vs. 6.8%; P = 0.29),AMI (2.7% vs. 4.1%; P = 0.41) or TVR (10.4% vs. 10.1%; P = 0.97). Conclusions: In this real world population, cobaltchromiumstents had similar efficacy and safety when compared to stainless steel stents, but with less coronary instrumentation.


Subject(s)
Humans , Male , Coronary Artery Disease/diagnosis , Coronary Restenosis , Stents , Aspirin/administration & dosage
15.
Clinics ; 64(7): 675-682, 2009. graf, tab
Article in English | LILACS | ID: lil-520801

ABSTRACT

BACKGROUND: Non-invasive detection of atherosclerosis is critical for its prevention. Objective: To correlate non-invasively detectable indicators of coronary atherosclerosis, or Coronary Artery Disease (i.e., classical risk factors, hs-CRP test results, carotid intima-media thickness, endothelial function, ankle-brachial index and calcium score by computed tomography) with the extent of coronary disease assessed by the Friesinger index from conventional coronary angiography. METHODS: We conducted a prospective study of 100 consecutive patients, mean age 55.1 ± 10.7 years, 55% men and 45% women. Patients with acute coronary syndrome, renal dialytic insufficiency, collagen disease and cancer were not included. All patients were subjected to clinical evaluation and laboratory tests. Endothelial function of the brachial artery and carotid artery were evaluated by high-resolution ultrasound; ankle-brachial index and computed tomography for coronary determination of calcium score were also performed, and non-HDL cholesterol and TG/HDL-c ratio were calculated. All patients were subjected to coronary angiography at the request of the assistant physician. We considered patients without an obstructive lesion (< 29% stenosis) demonstrated by coronary angiography to be normal. RESULTS: Univariate analysis showed that calcium score, HDL-c, TG/HDL ratio and IMT were significantly correlated with the Friesinger index. However, multivariate analysis indicated that only calcium score and low HDL-c levels correlated significantly with the extension of CAD. On the other hand, hs-CRP, LDL-c, flow-mediated dilation, and Framingham score did not correlate with the Friesinger index. ROC analysis showed that calcium score, HDL-c and TG-HDL ratio accurately predicted extensive CAD in a statistically significant manner...


Subject(s)
Female , Humans , Male , Middle Aged , Atherosclerosis/diagnosis , Calcium/analysis , Coronary Artery Disease/diagnosis , Biomarkers/blood , C-Reactive Protein/analysis , Coronary Angiography , Calcium/metabolism , Cholesterol, HDL/blood , Hypertension/diagnosis , Multivariate Analysis , Predictive Value of Tests , Prospective Studies , Tomography, X-Ray Computed , Triglycerides/blood
16.
Arq. bras. cardiol ; 87(2): 99-105, ago. 2006. tab, graf
Article in Portuguese | LILACS | ID: lil-433995

ABSTRACT

OBJETIVO: Certas características geométricas angiográficas de lesões coronarianas foram descritas como preditoras independentes de um futuro infarto do miocárdio. O objetivo deste estudo foi correlacionar esses marcadores com achados do ultra-som intracoronariano sabidamente associados com maior vulnerabilidade à ruptura de placa. MÉTODOS: Estudou-se 30 pacientes com síndromes coronarianas estáveis e lesões de novo (31 lesões) com angiografia e ultra-som intracoronariano. Para cada lesão as características geométricas angiográficas (grau de simetria, grau de estenose, comprimento da lesão e ângulo de saída) foram correlacionadas com as variáveis ultra-sonográficas: tipo de placa (mole, fibrosa, mista ou calcificada), área porcentual de placa e índice de remodelamento. RESULTADOS: O comprimento médio da lesão foi de 9,2 ± 4,4 mm, o porcentual de estenose foi de 50,0 por cento a 89,0 por cento (média 67,7 ± 12,1 por cento), ângulos de entrada variaram de 8,48° a 48,78° (média 24,0 ± 11,4°), ângulos de saída variaram de 8,30° a 53,03° (média 23,8 ± 11,7°) e o índice de simetria variou de 0 a 1 (média 0,56 ± 0,32). A avaliação com ultra-som intracoronariano, freqüência de placas moles ou calcificadas, remodelamento positivo e magnitude da área porcentual de placa não foram associados com nenhuma característica geométrica angiográfica (p > 0,05 para todas as análises). CONCLUSÃO: Características geométricas angiográficas que predis-põem à oclusão aguda não se correlacionam com achados morfológicos e quantitativos do ultra-som intracoronariano associados com a vulnerabilidade da placa.


Subject(s)
Female , Humans , Male , Middle Aged , Coronary Angiography , Coronary Artery Disease , Coronary Vessels/pathology , Myocardial Infarction/etiology , Angina, Unstable/pathology , Angina, Unstable , Angina, Unstable , Coronary Artery Disease/pathology , Coronary Artery Disease , Coronary Artery Disease , Coronary Vessels , Predictive Value of Tests , Syndrome
SELECTION OF CITATIONS
SEARCH DETAIL