Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Article in English | LILACS | ID: biblio-1402025

ABSTRACT

The middle ear is important from an anatomical and clinical point of view, seeing that it contains and allows the passages of structures, in addition to establishing relations with other regions of the head. However, the middle ear is small and difficult to dissect, making difficult the study in cadavers and understanding. In this context, professors and students from Universidade Estadual do Oeste do Paraná developed an anatomical model of the middle ear, showing its main bones, membranes, muscles and nerves. The model was developed with acrylic plates joined to form a cube, each side representing one of the middle ear's walls. The tympanic membrane and the secondary tympanic membrane were represented by an elastic fabric, which covered openings on the membranous wall and the labyrinthic wall, respectively. The auditory ossicles, the muscles and the nerves were made from polymer clay and positioned inside the cube, according to their characteristics and anatomical position in the middle ear. Furthermore, the auditory tube was represented by a plastic cone projecting from the carotid wall. The use of these low-cost anatomical models is an alternative to enable and improve learning. These initiatives favor the teaching of Human Anatomy, increasing understanding, the establishment of clinical correlations, and improving the academic education of health professionals (AU)


A orelha média é importante do ponto de vista anatômico e clínico, pois contém e permite a passagem de estruturas, além de estabelecer relações com outras regiões da cabeça. Porém, a orelha média é pequena e dissecação, o que dificulta seu estudo em cadáveres e a compreensão por parte dos alunos. Nesse contexto, docentes e discentes da Universidade Estadual do Oeste do Paraná desenvolveram um modelo anatômico da cavidade timpânica, apresentando seus principais componentes membranáceos, ósseos, musculares e nervosos. Para a confecção da maquete, placas de acrílico transparente foram unidas formando um cubo, com cada placa representando uma das paredes da cavidade timpânica (exceto a parede tegmental). Tecidos elásticos foram colocados em orifícios feitos nas paredes membranácea e labiríntica para representação da membrana timpânica e da membrana timpânica secundária, respectivamente. Os ossículos da audição, músculos e nervos foram confeccionados em biscuit e posicionados no espaço interno do cubo, observando-se as características e a posição anatômica dessas estruturas na orelha média. A tuba auditiva foi representada pela colocação de um cone plástico projetando-se a partir da parede carótica. A confecção de modelos didáticos é uma alternativa de baixo custo para facilitar o ensino e a compreensão da Anatomia Humana. O aprendizado de conceitos básicos favorece o entendimento das correlações anatomoclínicas, melhorando a formação acadêmica dos profissionais de saúde (AU)


Subject(s)
Teaching , Ear, Middle/anatomy & histology , Education, Medical , Models, Anatomic
2.
Fisioter. pesqui ; 22(1): 54-60, Jan-Mar/2015. tab, graf
Article in English | LILACS | ID: lil-744389

ABSTRACT

Manipulation of the spinal column is a manual therapeutic resource characterized by passive thrust of a given joint at a high velocity and low amplitude within the limits of anatomic integrity. The objective of the present study was to assess the immediate effects of upper thoracic manipulation on skin temperature in the vertebral region in healthy women. Thus, a randomized controlled blind trial was realized in the university community. Twenty-six healthy women were randomly allocated into an experimental group (n=13) and a placebo group (n=13). A single session of upper thoracic spine manipulation (segment T3) was performed. Infrared thermography was used to determine changes in skin temperature in the vertebral region. Images were taken prior to, immediately after and both five and 10 minutes after manipulation. Two-way repeated measures analysis of variance with post hoc Bonferroni test was used for inter and intragroup comparisons. The level of significance was set to 5%. No significant differences were found between the different evaluation times in either group (p>0.05). In the intergroup analysis, no statistically significant differences were found in any of the comparisons (p>0.05). Based on the method employed, thoracic spine manipulation of the T3 vertebral segment does not promote changes in skin surface temperature in the region manipulated in asymptomatic individuals.


A manipulação da coluna vertebral é um recurso da terapia manual caracterizado por um impulso passivo de alta velocidade e baixa amplitude dentro dos limites de integridade anatômica de uma articulação (thrust). O objetivo do presente estudo foi avaliar os efeitos imediatos da manipulação torácica alta sobre a temperatura superficial cutânea da região vertebral em mulheres saudáveis. Para tal, foi realizado um estudo clínico randomizado cego na comunidade universitária. Vinte e seis voluntárias saudáveis foram alocadas de forma randomizada em um grupo experimental (n=13) e um grupo placebo (n=13). Uma sessão de manipulação torácica alta (segmento T3) foi realizada. Foi empregada a termografia infravermelha para determinar alterações na temperatura cutânea na região vertebral. Imagens foram capturadas antes, imediatamente após, cinco e dez minutos após a manipulação. Foi usada análise de variância com medidas repetidas (dois critérios) seguida do teste de Bonferroni para as comparações inter e intragrupos. Adotou-se um nível de significância de 5%. Não foi encontrada diferença significativa nas diferentes avaliações ao longo do tempo (p>0,05). Na análise intergrupos, não foi constatada diferença significativa nas comparações realizadas (p>0,05). Com base na metodologia empregada, a manipulação torácica do segmento vertebral T3 não promoveu alterações na temperatura superficial cutânea na região manipulada.


La manipulación de la espina dorsal es un recurso de terapia manual que se caracteriza por un impulso pasivo de alta velocidad y baja amplitud de los límites de integridad anatómica de una articulación (thrust). Esta investigación tuvo por objetivo evaluar los efectos inmediatos de la alta manipulación torácica de la temperatura superficial de la piel en la región vertebral en mujeres sanas. Para eso, se ha realizado un estudio clínico aleatorizado ciego en la comunidad universitaria. Veintiséis voluntarias han sido puestas de forma aleatorizada en un grupo experimental (n=13) y un grupo placebo (n=13). Ha sido realizada una sesión de manipulación torácica alta (segmento T3). Se ha empleado el término infrarrojo para determinar alteraciones en la temperatura de la piel en la región vertebral. Se han capturado imágenes antes, inmediatamente después, cinco y diez minutos tras la manipulación. Se ha hecho un análisis de los cambios con medidas repetidas (dos criterios) seguido de la prueba de Bonferroni para las comparaciones inter e intragrupal. Se ha adoptado un nivel de significancia de 5%. No ha sido encontrado diferencias significativas en las diferentes evaluaciones al largo del tiempo (p>0,05). En el análisis intergrupal, no ha sido constatado diferencias significativas en las comparaciones realizadas (p>0,05). Basándose en la metodología empleada, la manipulación torácica del segmento vertebral T3 no cambió la temperatura superficial de la piel en la región estudiada.


Subject(s)
Humans , Female , Young Adult , Manipulation, Spinal , Skin Temperature , Spine , Thermography/methods , Randomized Controlled Trials as Topic , Single-Blind Method
3.
Acta sci., Health sci ; 36(1): 5-10, jan.-jun. 2014. tab
Article in English | LILACS | ID: biblio-833416

ABSTRACT

This study investigated and compared the effects of low-level laser therapy (LLLT) and microcurrent in the burn healing process in Wistar rats. We conducted a randomized controlled study with 30 rats divided into 3 groups (n = 10); control group (CG), laser group (LG) and microcurrent group (MG). After thermal damage, 10 applications of 660 nm diode laser were performed in GL and 10 applications of 60 Hz microcurrent (160 µA) in MG. The semi-quantitative histological analysis was done using scores (0­3), in sections stained by hematoxylin and eosin and Masson's trichrome. The results indicated a significant improvement in the fibroblasts proliferation, collagen fibers deposition, neoangiogenesis, and cutaneous appendages regeneration in MG and LG. When microcurrent and LLLT were compared, no difference was detected, except the regeneration and formation of new cutaneous appendages, observed in MG. Despite the similar effects, GM showed faster tissue repair with the formation of skin appendages.


Este trabalho teve por objetivo investigar e comparar os efeitos da laserterapia de baixa intensidade (LTBI) e microcorrente no processo de reparo de queimadura em ratos Wistar. Foi realizado um estudo randomizado controlado com 30 ratos divididos em 3 grupos (n = 10); grupo controle (GC), grupo laser (GL) e grupo microcorrente (GM). Após lesão térmica, 10 aplicações de laser InGaAlP de 660 nm foram submetidas ao GL e 10 aplicações de microcorrente de 60 Hz (160 µA) ao GM. Foi realizada análise semi-quantificativa dos dados histológicos através de escores (0-3), em cortes corados por hematoxilina e eosina e tricrômico de Masson. Os resultados indicaram que houve melhora significativa na proliferação de fibroblastos, deposição de fibras colágenas, neoangiogênese e regeneração de apêndices cutâneos no GM e GL. Quando a microcorrente e a LTBI foram comparados, não houve diferença, exceto na regeneração e formação de apêndices cutâneos, observada no GM. O laser e a microcorrente produziram melhora no reparo tecidual de queimaduras em ratos. Embora possua efeitos semelhantes, o GM apresentou reparação tecidual mais rápida com o aparecimento de apêndices cutâneos.


Subject(s)
Rats , Wound Healing , Electric Stimulation Therapy , Low-Level Light Therapy
4.
Fisioter. pesqui ; 20(1): 24-30, mar. 2013. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-674296

ABSTRACT

Este estudo teve o objetivo de investigar se há diferenças entre as terapias associadas e isoladas do laser e microcorrentes no reparo de lesão por queimadura em ratos. Um total de 40 animais foi dividido aleatoriamente em quatro grupos: grupo controle (GC); grupo microcorrente (GM), grupo laser (GL) e grupo laser/microcorrente (GLM), tratados com laser associado a microcorrentes. Após lesões térmicas induzidas no dorso do animal, foi realizado um total de dez dias de tratamento. Amostras do tecido foram coletadas para estudo histopatológico semiquantitativo com Hematoxilina Eosina e Tricrômico de Masson. Foram utilizados os testes de Kruskal-Wallis e post-hoc de Dunn. Houve diferença significativa entre os grupos para a produção de fibroblastos (p=0,0003), colágeno (p=0,0153), neoangiogênese (p=0,0031) e anexos cutâneos (p=0,0004). Na análise histológica semiquantitativa, o GLM apresentou valores menores nos parâmetros histológicos de presença de colágeno, número de fibroblastos e anexos cutâneos (p<0,05) em relação às terapias isoladas, exceto para a neoangiogênese, cujos valores da terapia associada foram semelhantes aos grupos de terapia com modalidade única. Apesar do laser e da microcorrente separadamente terem efeitos benéficos para a cicatrização tecidual, a associação das modalidades parece ter diminuído a ação de reparo. No entanto, sugere-se que a associação destes recursos parece diminuir os efeitos do tratamento quando se comparam os grupos de modalidade única.


This study aimed to investigate if there are differences between the associated and isolated therapies from the laser and micro current on healing of burn wound healing in rats. A total of 40 male rats were randomly allocated into four groups: control group (CG), micro current group (MG), laser group (LG) and laser/micro current group (LMG), treated with associated laser and micro current. Thermal damage was done on the back of the animal and a total of ten days therapy was performed. After treatment samples were taken from the lesions to perform semi quantitative histopathological study using Hematoxylin Eosin and Masson Trichrome. The Kruskal-Wallis and Dunn's Test were used for statistical analyses. We observed a significant difference between groups for production of fibroblasts (p=0.0003), collagen (p=0.0153), neoangiogenesis (p=0.0031) and skin annexes (p=0.0004). In semi-quantitative histological analysis, the LMG showed lower values in presence of collagen, fibroblasts and number of skin appendages, only for neoangiogenesis, the associated therapy showed similar values to single modality therapy groups. Laser and microcurrent have beneficial effects on tissue healing. However, it is suggested that the association of these two therapies reduces the effectiveness of the treatment when compared to single mode treatment.


Este estudio tiene el objetivo de investigar si hay diferencias entre las terapias asociadas y aisladas del láser y microcorrientes en la reparación de lesión por quemadura en ratas. Un total de 40 animales fueron divididos aleatoriamente en cuatro grupos: grupo control (GC), grupo microcorriente (GM), grupo láser (GL) y grupo láser/microcorriente (GLM), tratados con láser asociado a microcorrientes. Después de inducidas las lesiones térmicas en el dorso del animal, fueron realizados en total diez días de tratamiento. Las muestras de tejido fueron recolectadas para el estudio histopatológico semicuantitativo usando Hematoxilina Eosina y Tricómico de Masson. Fueron utilizados los tests de Kruskal-Wallis y post-hoc de Dunn's. Hubo diferencia significativa entre los grupos para la producción de fibroblastos (p=0,0003), colágeno (p=0,0153), neoangiogénesis (p=0,0031) y anexos cutáneos (p=0,0004). En el análisis histológico semicuantitativo, el GLM presentó valores menores en los parámetros histológicos de presencia de colágeno, número de fibroblastos y anexos cutáneos (p<0,05) en relación a las terapias aisladas, excepto para la neoangiogénesis, cuyos valores de la terapia asociada fueron semejantes a los grupos de terapia con modalidad única. A pesar de que el láser y la microcorriente de forma aislada tienen efectos benéficos para la cicatrización del tejido, la asociación de las modalidades parece haber disminuido la acción de la reparación. El láser y las microcorrientes son efectivos en acelerar el proceso de reparación del tejido. Sin embargo, se sugiere que la asociación de estos recursos parece disminuir los efectos del tratamiento cuando son comparados con los grupos de modalidad única.


Subject(s)
Animals , Rats , Combined Modality Therapy , Electric Stimulation , Laser Therapy , Burns/therapy , Wound Healing
SELECTION OF CITATIONS
SEARCH DETAIL