Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
ImplantNewsPerio ; 3(1): 38-44, jan.-fev. 2018. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-881423

ABSTRACT

Objetivo: verificar a variação das medidas lineares em função de angulações distintas dos implantes e dos alinhamentos diferentes das imagens de TCFC. Material e métodos: três mandíbulas artificiais de polietileno receberam 18 implantes dentários, com seis implantes em cada mandíbula, sendo: 1) dois angulados no sentido distal no lado direito posterior, 2) um angulado para vestibular e outro para lingual na região anterior, e 3) dois angulados no sentido mesial na região posterior esquerda. Com a mandíbula apoiada na mentoneira do equipamento e paralela ao plano horizontal, foram realizadas três aquisições tomográficas padronizadas, (voxel de 0,133 mm, FOV 6 x 8 cm, 89kV, 10 mA). Depois, foram realizadas uma medida perpendicular (da plataforma do implante ao rebordo mandibular) e outra inclinada (da plataforma do implante ao longo eixo do rebordo) nos cortes coronais e sagitais. As medidas foram realizadas com a base de mandíbula paralela ao plano horizontal e também após o volume ser rotacionado para o inferior no plano sagital. Os implantes foram numerados de um a seis e divididos em duplas. As medidas foram comparadas antes e após o alinhamento das imagens através do programa OnDemand3D. Resultados: foram observadas diferenças estatisticamente significantes entre as medidas realizadas nos implantes 1 e 2. Conclusão: as medidas lineares sofreram alteração em decorrência do posicionamento mandibular quando manipulado em software.


Objective: to verify the linear measure variation according to the distinct implants angulations and the different alignment from CBCT images. Material and methods: three polyethylene artifi cial models received 18 dental implants, 6 in each jaw, being: 1) two angled to distal on the right posterior side, 2) one angled to vestibular and another to lingual on the anterior region, 3) two angled to mesial way on the left posterior region. Each jaw was supported at a chinstrap of the equipment and parallel to the horizontal plane, and three standardized tomographic acquisitions were taken, (voxel size 0.133 mm, FOV 6 x 8 cm, 89kV, 10 mA). A perpendicular measure was made after the tomographic acquisitions (from the implant platform to the jaw border) and another inclined measure (from the implant platform to border long axis) both on coronal and sagittal acquisitions. Measurements were taken with the jaw base parallel to the horizontal plane and also when the volume was rotated to inferior on the sagittal plane. The implants were numbered from one to six and divided into couples. The measures were compared before and after image alignment by the OnDemand3D software. Results: statistically signifi cant differences were observed between the measurements performed on implants 1 and 2. Conclusion: the linear measurement values change in consequence of the jaw position when manipulated by the software.


Subject(s)
Humans , Cone-Beam Computed Tomography , Data Interpretation, Statistical , Dental Implantation/instrumentation , Radiography, Panoramic , Technology, Dental
2.
ImplantNewsPerio ; 2(6): 1061-1068, nov.-dez. 2017. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-880965

ABSTRACT

Objetivo: avaliar o grau de conhecimento dos cirurgiões-dentistas que atuam na atenção básica do município de Patos (PB) sobre os bifosfonatos e sua repercussão no tratamento odontológico. Material e métodos: neste estudo observacional transversal, 34 cirurgiões-dentistas responderam ao questionário sobre conhecimentos gerais dessa medicação. Resultados: os resultados do estudo evidenciaram um baixo conhecimento acerca dos bifosfonatos (52,9%). De modo geral, o estudo apontou o desconhecimento acerca da droga e sua repercussão no tratamento odontológico pelos cirurgiões-dentistas do município de estudo. Conclusão: é necessária a aquisição de conhecimentos por parte dos profi ssionais da Odontologia em relação a esses fármacos, a fi m de oferecerem aos seus pacientes um tratamento mais amplo e completo, com todas as informações e alternativas necessárias


Objective: to evaluate the degree of dental surgeons knowledge who work in the basic care of the municipality of Patos (PB) on bisphosphonates and its repercussion in dental treatment. Material and methods: in this cross-sectional observational study, 34 dental surgeons answered the questionnaire about the general knowledge of this medication. Results: the results of the study showed low knowledge about bisphosphonates (52.9%). In general, the study pointed out the unknowledge about the drug and its repercussion on dental treatment by the dental surgeons of the study municipality. Conclusion: it is necessary to acquire knowledge from dental professionals in relation to these drugs, so that they can offer their patients a wider and complete treatment, with all the necessary information and alternatives.


Subject(s)
Humans , Male , Female , Bisphosphonate-Associated Osteonecrosis of the Jaw , Diphosphonates/adverse effects , Diphosphonates/therapeutic use , Health Knowledge, Attitudes, Practice , Osteoporosis , Primary Health Care
3.
ImplantNewsPerio ; 2(2): 234-241, mar.-abr. 2017. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-847145

ABSTRACT

Objetivo: comparar as medidas de altura e largura em sítios ósseos edêntulos, através de um software (OnDemand3D), em diferentes regiões da cavidade bucal utilizando TCFC. Material e métodos: a amostra do estudo foi composta de 100 sítios edêntulos divididos em quatro grupos. Grupo A: 25 sítios para a região posterossuperior; grupo B: 25 sítios para a região anterossuperior; grupo C: 25 sítios para a região posteroinferior; e grupo D: 25 sítios para a região anteroinferior. As medidas foram realizadas por três observadores em dois tempos, com intervalo de 15 dias. Para facilitar as medidas, cada observador mediu a altura e a largura de cada sítio, orientado a medir na sua maior extensão, utilizando a ferramenta de medida do software. Após o término, as medidas foram tabuladas para aplicação dos testes estatísticos. Foram comparadas as medidas intra e interexaminadores: para os dados intraexaminadores, foram aplicados os testes t de Student para amostras pareadas mais ICC; e para os dados interexaminadores, utilizou-se a análise de variância (Anova) para medidas repetidas mais a correlação interclasse (ICC), todos com nível com significância de 95%. Resultados: houve algumas diferenças, principalmente em relação à largura, quando utilizados os testes t de Student e Anova. Quando utilizado o teste ICC, que mede a concordância, não houve diferenças estatísticas, tanto intra quanto interexaminadores. Conclusão: independentemente da região analisada, houve uma boa concordância intra e interexaminadores, apresentando pequenas diferenças para as medidas de largura.


Objective: to compare height and width measurements in edentulous bone sites using software (OnDemand3D) in different regions of the oral cavity after CBCT. Material and methods: the studied sample was consisted of 100 edentulous sites divided into 4 groups. Group A: 25 sites for the posterossuperior region; group B: 25 sites for the anterosuperior region; group C: 25 sites for the posterolateral region; and group D: 25 sites for the anteroinferior region. The measurements were performed by three observers at two times intervals of 15 days. To facilitate the measurements, each observer measured (height and width) of each site oriented to measure to its greatest extent, using the software tool of measurement. After completion, the measurements were tabulated for statistical tests. Intra and inter-examiner measurements were compared: intra-examiner data were applied t-student tests for paired samples plus ICC and for the inter-examiner data the analysis of variance (Anova) was used for repeated measures plus interclass correlation ICC), all with a level of 95% signifi cance. Results: the results demonstrated the existence of some differences mainly with respect to the width when the t-Student and Anova tests were used. When using the ICC test, which measures agreement, there were no statistical differences either intra- or inter-examiner. Conclusion: regardless of the region analyzed, there was a good intra and inter-examiner agreement, with small differences in width measurements.


Subject(s)
Humans , Cone-Beam Computed Tomography , Dental Implantation , Surgery, Oral , Technology, Dental
SELECTION OF CITATIONS
SEARCH DETAIL