Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Arq. bras. med. vet. zootec ; 57(supl.2): 270-272, set. 2005. tab
Article in Portuguese | LILACS | ID: lil-432025

ABSTRACT

The frequency 01 Pteromalidae species lound in Diptera pupae that were collected Irom cattle 'dung in Pandmá, State 01 Goiás, Brazil, between May and December 2003 was studied. The pupae were obtained by the jlotation method and were individually placed in gelatin capsules until the emergence 01 the adultjlies or their parasitoids. The overall percentage 01 parasitism was i4. 7. The percentage 01 parasitismpresented by the parasitoids Pachycrepoideus vindemmiae (Rondani), Spalangia cameroni Perkins,Spalangia drosophilae Ashmead, Spalangia endius Walker, Spalangia nigra Latrielle and Spalangia nigroaenea Curtis were i. 7, iA, 2.4, 0.7, 204 and 6. i, respectively.


Subject(s)
Cattle , Feces/parasitology , Parasites , Parasitic Diseases
2.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.141-142.
Monography in Portuguese | LILACS | ID: lil-236286

ABSTRACT

Um sistema baseado em computador pessoal é usado para a monitorização cardio-respiratória de pacientes, em tempo-real, integrando sinais obtidos de diferentes equipamentos: monitor fisiológico (ECG), espectrômetro de massa respiratória (EMR: frações gasosas) e pneumotacógrafo (fluxo ventilatório). O sistema detecta complexos QRS e ciclos respiratórios, e calcula freqüência cardíaca e vários parâmetros respiratórios. O desempenho dos algoritmos é avaliado com sinais simulados, o MIT-BIH Arrhytmia Database e experimentos in-vivo. O sistema é empregado em pesquisa da fisiologia do exercício


Abstract- A modular system based on a personal computer is used to perform real-time cardio-respiratory monitoring of patients. integrating data from different equipments: a bed side monitor (ECG ), a respiratory mass spectrometer (RMS: gas fractions) and a pneumothacograph (respiratory tlow). The system includes an automatic detection of the QRS complexes and the respiratory cycles and it calculates heart rate and severa! respiratory parameters. The performance of the algorithms is estimated with simulated data. the MIT-BIH Arrhythrnia Database and in rivo experirnents. This system is being used for research in exercise physiology


Subject(s)
Cardiopulmonary Bypass , Exercise/physiology , Monitoring, Ambulatory/methods , Software , Computers
3.
Braz. j. med. biol. res ; 26(1): 37-42, Jan. 1993. ilus, graf
Article in English | LILACS | ID: lil-148671

ABSTRACT

Regional left ventricular myocardial blood flow was studied in an experimental model of pulmonary edema and microembolization (PEM) ventilated with positive end-expiratory pressure (PEEP). The analysis was based on a 3-dimensional extension of the autocorrelation function used to assess the spatial correlation (rspat) of myocardial perfusion. Experiments were performed on 8 premedicated, anesthetized and mechanically ventilated dogs. PEM was induced with oleic acid (0.01 mg/kg) and glass beads. Successive PEEP values of 10, 15 and 20 cm H2O (P20) were applied and norepinephrine (NE, 0.2-1.0 microgram min-1 kg-1) was administered after P20. Regional perfusion was measured with radioactive microspheres. The left ventricle (LV) was dissected into 256 samples. rspat was computed as the correlation of regional perfusions of samples p units apart in the apex-to-base, endo-epicardial and angular directions. Analysis was performed after anesthesia and instrumentation (control, C), P20 and NE. Control values of rspat were around 50 per cent in the apex-to-base and angular directions and the sign was inverted in the endo-epicardial direction. A reduction of rspat to values close to zero was observed in all directions for P20 and NE. This is the typical pattern of independent distribution. Thus, the results indicate that, under the experimental conditions used, there is some degree of neighborhood dependence of regional LV myocardial blood flow. This dependence is not observed under PEM, mechanical ventilation with PEEP and NE


Subject(s)
Animals , Dogs , Ventricular Function, Left/physiology , Pulmonary Edema/physiopathology , Combined Modality Therapy , Disease Models, Animal , Ventricular Function, Left , Norepinephrine/therapeutic use , Positive-Pressure Respiration , Pulmonary Edema/therapy
4.
Rev. bras. anestesiol ; 38(6): 393-7, nov.-dez. 1988. ilus
Article in Portuguese | LILACS | ID: lil-74891

ABSTRACT

O metil-eugenol (C11H14O2), peso molecular igual a 178 g, fraçäo oleosa essencial obtida da planta Caryophyllus aromaticus L, conhecida popularmente como "Craveiro-da-índia", provocou efeitos depressores centrais, com significativa açäo hipnótica e miorrelaxante nas doses de 40 mg.Kg-1 intraperitoneal para ratos e 5 mg.Kg-1 por via venosa para coelhos e cäes. Observamos tempo de induçäo rápido e duraçäo satisfatória do sono (118 ñ 4s e 47 ñ 3 min para ratos, respectivamente) e tempo de sono entre 9 e 12 minutos para coelhos e cäes. A evoluçäo anestésica em cäes mostrou resultados satisfatório, seguido de rápida recuperaçäo, com conseqüente deambulaçäo. O metil-eugenol (20 microng.ml-1) produziu reduçäo de 50% da força de contraçäo da musculatura atrial cardíaca ao final de 15 min, sem alteraçäo da freqüência cardíaca, cujos efeitos näo foram bloqueados pela atropina (25 microng.ml-1) e prontamente revertidos após lavagem. Na preparaçäo nervo frênico-músculo diafragma de rato o metil-eugenol (40 microng.ml-1) foi capaz de bloquear completamente as contraçöes musculares produzidas tanto por estímulo direto quanto por estímulo indireto, semelhantes ao efeito da lidocaína (200 microng.ml-1). Todos os efeitos foram revertidos após lavagem. Os autores concluem que o metil eugenol apresentou resultados significativos e pode vir a ser usado, alternativamente, em experimentos com animais de laboratório


Subject(s)
Dogs , Mice , Rabbits , Rats , Animals , Anesthesia, Intravenous , Muscle Contraction , Diaphragm/drug effects , Eugenol/pharmacology
5.
RBE, Cad. eng. bioméd ; 4(2): 99-110, dez. 1987. ilus, tab
Article in Portuguese | LILACS | ID: lil-57485

ABSTRACT

O sistema experimental utilizado na realizaçäo do teste de lavagem de nitrogênio com respiraçäo única (TN2-RU) compöe-se de vários dispositivos destinados à obtençäo de mediçöes confiáveis de fluxos e volumes respirados. Neste trabalho é apresentado um sistema experimental alternativo baseado em computador que dispensa equipamentos adicionais por possibilitar a correçäo dos erros pelo programa de processamento do teste, utilizando equaçöes que descrevem algums dos erros e determinaçöes experimentais prévias de outros. As mediçöes de fluxo aéreo e fraçöes de N2 säo feitas, respectivamente, com pneumotacógrafo e analisador rápido de gases. Na análise dos erros com origem no pneumotacógrafo considera-se a diferença entre as geometrias do sistema de conduçäo de ar a montante e a jusante do local de mediçäo e as variaçöes na viscosidade do ar respirado durante o teste, propondo-se um algoritmo para correçäo destas variaçöes que utiliza apenas as fraçöes de N2 medidas. Para o analisador de N2, determina-se experimentalmente causas de atrasos entre equipamentos: espaço morto do sistema e tempo de resposta do aparelho. A avaliaçäo do algoritmo para correçäo das variaçöes da viscosidade feita por modelo matemático de trocas gasosas mostra erros inferiores a 0,4% para pulmöes unicompartimentais. Conclui-se pela validade do sistema baseado em computador para realizaçäo do TN2-RU, em indivíduos com pulmöes homogêneos


Subject(s)
Nitrogen/therapeutic use , Respiration , Therapeutic Irrigation , Algorithms , Evaluation Study , Lung Volume Measurements
SELECTION OF CITATIONS
SEARCH DETAIL