Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Emergency Medicine ; (12): 944-947, 2022.
Article in Chinese | WPRIM | ID: wpr-954522

ABSTRACT

Objective:To discuss the essentials of anesthesia management and treatment strategies for emergency transcatheter aortic valve replacement (TAVR), and to provide standardized recommendations for the development of emergency TAVR technology in China.Methods:This study retrospectively analyzed the relevant data of patients undergoing emergency TAVR surgery in the Second Affiliated Hospital of Zhejiang University School of Medicine from March 2019 to February 2021, including baseline patient characteristics, perioperative echocardiography data, prognosis and 30-day follow-up. Post-operative data were compared with pre-operative data using paired-sample test.Results:Thirteen patients, aged (75.62±9.63) years, underwent emergency TAVR surgery, and 6 of them were male. Eleven patients were New York Heart Association class Ⅳ. The preoperative Society of Thoracic Surgeons score was (20.31±15.15)%. The trans-aortic valve differential pressure was significantly reduced after surgery [(68.92±30.66)mmHg vs. (2.70±2.36)mmHg, P<0.01]. Two patients died within 30 days after surgery, one patient developed a new third degree atrioventricular block, one patient had a stroke, and 4 patients developed pulmonary infection. Conclusions:Emergency TAVR surgery is a feasible and effective rescue strategy for patients with aortic stenosis in critical condition. The establishment of anesthesia standard operation procedure process for TAVR surgery helps ensure homogenized medical behavior and good teamwork.

2.
Journal of Biomedical Engineering ; (6): 632-636, 2008.
Article in Chinese | WPRIM | ID: wpr-342775

ABSTRACT

Hemolysis in blood pumps has been measured by various in vitro tests, in which normalized index of hemolysis (NIH) was established. As NIH is complicated and difficult to calculate, erythrocyte fragment count (EFC) is proposed in the present study to predict hemolysis in roller pumps. Five paired in vitro tests were conducted using the POLYSTAN pediatric pump (group A) and COBE pump (group B). Ten whole blood samples (400ml) were circled in the roller pump for 16 hours. Erythrocyte fragments count and plasma-free hemoglobin (FHb) were measured before pumping and every 2 hours through circulation after 4 hours pumping. The morphological changes of erythrocyte were observed by scanning electron microscope. Simple linear regression analysis showed the two groups' EFC and FHb levels increased linearly during a long period of pumping, and the coefficient of determination (R2) was 0.64. These data suggested that Erythrocyte fragments count could be used as an index in evaluating the in vitro hemolytic properties of blood pumps.


Subject(s)
Humans , Erythrocyte Deformability , Erythrocytes , Heart-Lung Machine , Hemoglobins , Hemolysis , Physiology , Microscopy, Electron, Scanning , Osmotic Fragility , Time Factors
3.
Journal of Biomedical Engineering ; (6): 419-422, 2002.
Article in Chinese | WPRIM | ID: wpr-357012

ABSTRACT

To observe the erythrocyte fragility and morphological changes of erythrocytes caused by roller pump. Ten tests were divided into two groups, Polystan pediatric pump group A (n = 5) and COBE pump group B (n = 5). Ten whole blood samples (each 400 ml) were circulated in the roller pump for 16 h. Erythrocyte fragility and free hemoglobin were measured before pumping and at every 2 hours during pumping. The possible morphological changes of erythrocytes caused by roller pump were observed by scanning electron microscope. The electron microscopic observation was made before pumping and at every 4 hours throughout pumping. Results showed that the erythrocyte fragility of two groups was not increased during a long period of pumping. The number of acanthocytes of two groups was 1.77/1.81% in the samples before pumping and 6.12/7.13, 9.18/8.73, 13.21/12.89, 16.53/17.21% at 4 h, 8 h, 12 h, and 16 h respectively. The free hemoglobin level of two groups was increased linearly during a long duration of pumping and the index of hemolysis of two groups was 0.296 mg/L/h and 0.3993 mg/L/h respectively. The result shows: 1. the erythrocyte fragility was not increased during a long period of pumping; 2. the erythrocyte membrane was injured or broken by roller pump directly; 3. the morphological changes of erythrocytes would be the basis of post operative hemolysis.


Subject(s)
Humans , Erythrocyte Deformability , Heart-Lung Machine , Hemoglobins , Hemolysis , In Vitro Techniques , Osmotic Fragility , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL