Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Braz. J. Anesth. (Impr.) ; 72(6): 720-728, Nov.-Dec. 2022. tab, graf
Article in English | LILACS | ID: biblio-1420615

ABSTRACT

Abstract Background Hydroxyethyl starches are colloids used in fluid therapy that may reduce volume infusion compared with crystalloids, but they can affect renal function in critical care patients. This study aims to assess renal effects of starches using renal biomarkers in the perioperative setting. Methods This prospective, controlled, randomized study compared Hydroxyethyl starch 6% (HES) with Ringer's lactate (RL) in hysterectomy. Each episode of mean arterial pressure (MAP) below 60 mmHg guided the fluid replacement protocol. The RL group received 300 mL bolus of RL solution while the HES group received 150 mL of HES solution. All patients received RL (2 mL.kg−1.h−1) intraoperatively to replace insensible losses. Blood and urine samples were collected at three time points (preoperatively, 24 hours, and 40 days postoperatively) to assess urinary NGAL and KIM-1, as primary outcome, and other markers of renal function. Results Seventy patients were randomized and 60 completed the study. The RL group received a higher crystalloid volume (1,277 ± 812.7 mL vs. 630.4 ± 310.2 mL; p= 0.0002) with a higher fluid balance (780 ± 720 mL vs. 430 ± 440 mL; p= 0.03) and fluid overload (11.7% ± 10.4% vs. 7.0% ± 6.3%; p= 0.04) compared to the HES group. NGAL and KIM-1 did not differ between groups at each time point, however both biomarkers increased 24 hours postoperatively and returned to preoperative levels after 40 days in both groups. Conclusion HES did not increase renal biomarkers following open hysterectomy compared to RL. Moreover, HES provided better hemodynamic parameters using less volume, and reduced postoperative fluid balance and fluid overload.


Subject(s)
Hydroxyethyl Starch Derivatives , Fluid Therapy/methods , Biomarkers , Prospective Studies , Plasma Substitutes , Colloids , Lipocalin-2 , Crystalloid Solutions , Ringer's Lactate , Hysterectomy , Isotonic Solutions , Kidney/physiology
2.
Rev. bras. anestesiol ; 69(2): 184-196, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1003407

ABSTRACT

Abstract Introduction: The importance and benefits of breastfeeding for the babies and mothers are well established and documented in the literature. However, it is frequent that lactating mothers need to undergo general or spinal anesthesia and, due to the lack of information, many of them interrupt breastfeeding after anesthesia. There are limited data available regarding anesthetics transfer to breast milk. This review aims to develop some considerations and recommendations based on available literature. Methods: A systematic search of the literature was conducted by using the following health science databases: Embase, Lilacs, Pubmed, Scopus, and Web of Science. The latest literature search was performed on April 6th, 2018. Additional literature search was made via the World Health Organization's website. We used the following terms for the search strategy: "Anesthesia" and "Breastfeeding", and their derivatives. Results: In this research, 599 registers were found, and 549 had been excluded by different reasons. Fifty manuscripts have been included, with different designs of studies: prospective trials, retrospective observational studies, reviews, case reports, randomized clinical trials, case-control, and website access. Small concentrations of the most anesthetic agents, are transferred to the breast milk; however, their administration seem to be safe for lactating mothers when administered as a single dose during anesthesia and this should not contraindicate the breastfeeding. On the other hand, high-doses, continuous or repeated administration of drugs increase the risk of adverse effects on neonates, and should be avoided. Few drugs, such as diazepam and meperidine, produce adverse effects on breastfed babies even in single doses. Dexmedetomidine seems to be safe if breastfeeding starts 24 h after discontinuation of the drug. Conclusions: Most of the anesthetic drugs are safe for nursing mothers and offer low risk to the breastfed neonates when administered in single-dose. However, high-dose and repeated administration of drugs significantly increase the risk of adverse effects on neonates. Moreover, diazepam and meperidine should be avoided in nursing women. Finally, anesthesiologists and pediatricians should consider individual risk/benefit, with special attention to premature neonates or babies with concurrent diseases since they are more susceptible to adverse effects.


Resumo Introdução: A importância e os benefícios do aleitamento materno para os bebês e para as mães estão bem estabelecidos e documentados na literatura. No entanto, é frequente que mães lactantes precisem se submeter à anestesia geral ou raquianestesia e, devido à falta de informações, muitas delas interrompem a amamentação após a anestesia. Existem poucos dados disponíveis sobre a transferência de anestésicos para o leite materno. O objetivo desta revisão foi desenvolver algumas considerações e recomendações com base na literatura disponível. Métodos: Uma busca sistemática da literatura realizada usando com os seguintes bancos de dados em ciências da saúde: Embase, Lilacs, Pubmed, Scopus e Web of Science. A pesquisa bibliográfica mais recente foi realizada em 6 de abril de 2018. Uma pesquisa bibliográfica adicional foi realizada através do site da Organização Mundial da Saúde. Usamos os seguintes termos para a estratégia de busca: "Anestesia" e "Aleitamento materno" e seus derivados. Resultados: Nesta pesquisa, 599 registros foram encontrados e 549 foram excluídos por diferentes razões. Foram incluídos 50 manuscritos, com diferentes modelos de estudo: estudos prospectivos, estudos observacionais retrospectivos, revisões, relatos de casos, ensaios clínicos randômicos, caso-controle e acesso a sites. Pequenas concentrações da maioria dos agentes anestésicos são transferidas para o leite materno; entretanto, sua administração parece ser segura para mães lactantes quando administrados em dose única durante a anestesia e isso não deve contraindicar o aleitamento materno. Por outro lado, altas doses, administração contínua ou repetida dos fármacos aumentam o risco de efeitos adversos em neonatos e devem ser evitados. Poucas drogas, como diazepam e meperidina, produzem efeitos adversos em bebês amamentados, mesmo quando administradas em doses únicas. Dexmedetomidina parece ser segura se a amamentação começar 24 horas após a interrupção do medicamento. Conclusões: A maioria dos anestésicos é segura para mães que amamentam e oferecem baixo risco para os recém-nascidos amamentados quando a administração é em dose única. No entanto, altas doses e repetidas administrações de drogas aumentam significativamente o risco de efeitos adversos em recém-nascidos. Além disso, diazepam e meperidina devem ser evitados em mulheres que amamentam. Finalmente, anestesiologistas e pediatras devem considerar o risco-benefício individual, com atenção especial para os recém-nascidos prematuros ou bebês com doenças concomitantes, pois são mais suscetíveis a efeitos adversos.


Subject(s)
Humans , Female , Infant, Newborn , Infant , Breast Feeding/methods , Anesthesia/methods , Milk, Human/metabolism , Time Factors , Lactation/psychology , Randomized Controlled Trials as Topic , Dose-Response Relationship, Drug , Anesthesia/adverse effects , Anesthetics/administration & dosage , Anesthetics/adverse effects
3.
Acta cir. bras ; 32(1): 14-21, Jan. 2017. tab, graf
Article in English | LILACS | ID: biblio-837670

ABSTRACT

Abstract Purpose: To evaluate a model for studying the toxicity in nervous tissue and meninges using ultrasound to guide needle insertion into the subarachnoid space of rabbits, with the objective of avoiding injuries triggered by the puncture and by intraneural injection of solutions. Methods: Forty-five adult female rabbits were divided into 3 groups (G): G1 underwent subarachnoid puncture, G2 underwent subarachnoid injection of saline solution and G3 underwent subarachnoid injection of 0.5% hyperbaric bupivacaine. A needle was inserted into the S1-S2 subarachnoid space guided by ultrasound. The sensitivity and motility of the animals were evaluated for 3 days, after which the animals were sacrificed for removal of lumbar and sacral portions of the spinal cord for histological examination by light microscopy and immunohistochemistry. Results: All animals had motor function and pain sensitivity on the evaluation period. No animal had complication during or after the procedures. Conclusion: Ultrasound is a useful and safe method for the correct identification of the subarachnoid space of rabbits.


Subject(s)
Animals , Female , Rabbits , Spinal Puncture/methods , Subarachnoid Space/diagnostic imaging , Ultrasonography, Interventional/methods , Reproducibility of Results , Models, Animal
4.
Clinics ; 69(6): 378-383, 6/2014. tab, graf
Article in English | LILACS | ID: lil-712700

ABSTRACT

OBJECTIVE: Pneumoperitoneum during laparoscopy results in transient oliguria and decreased glomerular filtration and renal blood flow. The presence of oliguria and elevated serum creatinine is suggestive of acute renal injury. Serum cystatin C has been described as a new marker for the detection of this type of injury. In this study, our aim was to compare the glomerular filtration rate estimated using cystatin C levels with the rate estimated using serum creatinine in patients with normal renal function who were undergoing laparoscopic surgery. METHODS: In total, 41 patients undergoing laparoscopic cholecystectomy or hiatoplasty were recruited for the study. Blood samples were collected at three time intervals: first, before intubation (T1); second, 30 minutes after the establishment of pneumoperitoneum (T2); and third, 30 minutes after deflation of the pneumoperitoneum (T3). These blood samples were then analyzed for serum cystatin C, creatinine, and vasopressin. The Larsson formula was used to calculate the glomerular filtration rate based on the serum cystatin C levels, and the Cockcroft-Gault formula was used to calculate the glomerular filtration rate according to the serum creatinine levels. RESULTS: Serum cystatin C levels increased during the study (T1 = T2<T3; p<0.05), whereas serum creatinine levels decreased (T1 = T2>T3; p<0.05). The calculated eGlomerular filtration rate-Larsson decreased, whereas the eGlomerular filtration rate-Cockcroft-Gault increased. There was no correlation between cystatin C and serum creatinine. Additionally, Pearson's analysis showed a better correlation between serum cystatin C and the eGlomerular filtration rate than between serum creatinine and the eGlomerular filtration rate. CONCLUSION: This study demonstrates that serum cystatin C is a more sensitive indicator of changes in the glomerular filtration rate than serum creatinine is in patients with normal ...


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Acute Kidney Injury/diagnosis , Creatinine/blood , Cystatin C/blood , Glomerular Filtration Rate , Vasopressins/blood , Acute Kidney Injury/blood , Biomarkers/blood , Laparoscopy , Sensitivity and Specificity
5.
Rev. Esc. Enferm. USP ; 48(2): 228-235, abr. 2014. tab
Article in English | LILACS, BDENF | ID: lil-711802

ABSTRACT


This study aimed to compare the efficiency of the thermal blanket and thermal mattress in the prevention of hypothermia during surgery. Thirty-eight randomized patients were divided into two groups (G1 – thermal blanket and G2 - thermal mattress). The variables studied were: length of surgery, length of stay in the post-anesthetic care unit, period without using the device after thermal induction, transport time from the operating room to post-anesthetic care unit, intraoperative fluid infusion, surgery size, anesthetic technique, age, body mass index, esophageal, axillary and operating room temperature. In G2, length of surgery and starch infusion longer was higher (both p=0.03), but no hypothermia occurred. During the surgical anesthetic procedure, the axillary temperature was higher at 120 minutes (p=0.04), and esophageal temperature was higher at 120 (p=0.002) and 180 minutes (p=0.03) and at the end of the procedure (p=0.002). The thermal mattress was more effective in preventing hypothermia during surgery.



El objetivo de este estudio fue comparar la eficacia de la manta y el colchón térmico en la prevención de la hipotermia durante el trans-operatorio. Participaron 38 pacientes asignados al azar en dos grupos (G1 – manta térmica y G2 - colchón térmico). Las variables estudiadas fueron: tiempo quirúrgico, tiempo de permanencia en la sala de recuperación post-anestésica (URPA), tiempo sin utilizar el dispositivo térmico después de la inducción anestésica, tiempo de transporte entre el quirófano y la URPA, infusión de fluidos durante el intra-operatorio, tamaño de la cirugía, técnica anestésica, edad, índice de masa corporal, temperatura axilar, esofágica y de la sala quirúrgica. En el G2, el tiempo quirúrgico y la infusión de almidón fueron mayores (ambos p = 0,03), pero no se produjo la hipotermia. Durante la anestesia quirúrgica, la temperatura axilar fue mayor a los 120 minutos (p = 0,04), y la temperatura esofágica fue mayor a los 120 (p = 0,002) y 180 minutos (p = 0,03) y al final de la cirugía (p = 0,002). El colchón térmico fue más eficaz en la prevención de la hipotermia durante la cirugía.
.



O objetivo deste estudo foi comparar a eficiência da manta e colchão térmicos na prevenção da hipotermia no transoperatório. Participaram 38 pacientes randomizados em 2 grupos (G1 – manta térmica e G2 – colchão térmico). As variáveis estudadas foram: tempo cirúrgico, tempo de permanência na sala de recuperação pós-anestésica, tempo sem a utilização do dispositivo térmico após a indução anestésica, tempo de transporte entre a sala cirúrgica e a de recuperação, infusão defluido no intraoperatório, porte cirúrgico, técnica anestésica, idade, índice de massa corpórea, temperatura axilar, esofágica e da sala cirúrgica. No G2, o tempo cirúrgico e a infusão de amido foram maiores (ambos p=0,03), porém, não ocorreu hipotermia. Durante o procedimento anestésico cirúrgico, a temperatura axilar foi maior aos 120 minutos (p=0,04) e a temperatura esofágica foi maior aos 120 (p=0,002), aos 180 minutos (p=0,03) e ao final da cirurgia (p=0,002). O colchão térmico mostrou-se mais eficaz na prevenção da hipotermia no transoperatório.
.


Subject(s)
Female , Humans , Male , Middle Aged , Bedding and Linens , Beds , Hypothermia/prevention & control , Intraoperative Complications/prevention & control , Cross-Sectional Studies , Double-Blind Method , Equipment Design , Prospective Studies , Temperature
6.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 58(2): 248-253, mar.-abr. 2012. ilus, tab
Article in English | LILACS | ID: lil-625065

ABSTRACT

OBJECTIVE: We evaluated whether endotracheal tube (ETT) intracuff alkalinized lidocaine was superior to saline in blunting emergence coughing, postoperative sore throat, and hoarseness in smokers. METHODS: In our prospective, double-blind trial, we enrolled 50 smoking patients undergoing surgery under general anesthesia including nitrous oxide (N2O). Patients were randomly allocated to receive either ETT intracuff 2% lidocaine plus 8.4% sodium bicarbonate (L group), or ETT intracuff 0.9% saline (S group). The ETT cuff was inflated to achieve a cuff pressure that prevented air leak during positive pressure ventilation. Incidence of emergence coughing, sore throat, and hoarseness were analyzed. The volume of inflation solution, the intracuff pressure, the duration of anesthesia, the time elapsed to extubation after discontinuation of anesthesia, and the volume of the inflation solution and the air withdrawn from the ETT cuff were also recorded. RESULTS: Intracuff alkalinized 2% lidocaine was superior to saline in blunting emergence coughing (p < 0.001). The incidence of sore throat was significantly lower in the L group at the post-anesthesia care unit (PACU) (p = 0.02). However, at 24 hours after extubation, sore throat incidence was similar in both groups (p = 0.07). Incidence of hoarseness was similar in both groups. Intracuff pressure in the saline group increased with time while the intracuff pressure in the lidocaine group remained constant. CONCLUSION: The present study demonstrated that the intracuff alkalinized 2% lidocaine was superior to saline in decreasing the incidence of emergence coughing and sore throat during the postoperative period in smokers.


Subject(s)
Female , Humans , Intubation, Intratracheal/methods , Lidocaine/administration & dosage , Smoking , Sodium Chloride/administration & dosage , Anesthesia, General/adverse effects , Cough/etiology , Double-Blind Method , Hoarseness/etiology , Incidence , Pharyngitis/etiology , Postoperative Complications
7.
São Paulo med. j ; 125(6): 322-328, Nov. 2007. graf, tab
Article in English | LILACS | ID: lil-476090

ABSTRACT

CONTEXT AND OBJECTIVE: High intracuff pressure in endotracheal tubes (ETs) may cause tracheal lesions. The aim of this study was to evaluate the effectiveness and safety of endotracheal tube cuffs filled with air or with alkalinized lidocaine. DESIGN AND SETTING: This was a prospective clinical study at the Department of Anesthesiology, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista. METHODS: Among 50 patients, ET cuff pressures were recorded before, 30, 60, 90 and 120 minutes after starting and upon ending nitrous oxide anesthesia. The patients were randomly allocated to two groups: Air, with ET cuff inflated with air to attain a cuff pressure of 20 cmH2O; and Lido, with ET cuff filled with 2 percent lidocaine plus 8.4 percent sodium bicarbonate to attain the same pressure. ET discomfort before tracheal extubation, and sore throat, hoarseness and coughing incidence were studied at the time of discharge from the post-anesthesia care unit, and sore throat and hoarseness were studied 24 hours after anesthesia. RESULTS: Pressures in Lido cuffs were significantly lower than in Air cuffs (p < 0.05). Tracheal complaints were similar for the two groups, except for lower ET discomfort and sore throat incidence after 24 hours and lower systolic arterial pressure at the time of extubation in the Lido group (p < 0.05). CONCLUSION: ET cuffs filled with alkalinized lidocaine prevented the occurrence of high cuff pressures during N2O anesthesia and reduced ET discomfort and postoperative sore throat incidence. Thus, alkalinized lidocaine-filled ET cuffs seem to be safer than conventional air-filled ET cuffs.


CONTEXTO E OBJETIVO: Os tubos traqueais são dispositivos utilizados para manutenção da ventilação. A hiperinsuflação do balonete do tubo traqueal, causada pela difusão do óxido nitroso (N2O), pode determinar lesões traqueais, que se manifestam clinicamente como odinofagia, rouquidão e tosse. A lidocaína, quando injetada no balonete do tubo traqueal, difunde-se através de sua parede, determinando ação anestésica local na traquéia. O objetivo foi avaliar a efetividade e a segurança do balonete do tubo traqueal preenchido com ar comparado com o balonete preenchido com lidocaína, considerando os desfechos: sintomas cardiovasculatórios (HAS, taquicardia); odinofagia, tosse, rouquidão e tolerância ao tubo traqueal. TIPO DE ESTUDO E LOCAL: Estudo clínico prospectivo, realizado no Departamento de Anestesiologia da Faculdade de Medicina da Unesp, campus de Botucatu. MÉTODOS: A pressão do balonete do tubo traqueal foi medida, entre 50 pacientes, antes, 30, 60, 90 e 120 minutos após o início da inalação de N2O anestésico. As pacientes foram distribuídas aleatoriamente em dois grupos: Air, em que o balonete foi inflado com ar para obtenção de pressão de 20 cm H2O, e Lido, em que o balonete foi preenchido com lidocaína a 2 por cento mais bicarbonato de sódio a 8,4 por cento para obtenção da mesma pressão. O desconforto antes da extubação, e manifestações clínicas como dor de garganta, rouquidão e tosse foram registrados no momento da alta da unidade de cuidados pós-anestésicos, e dor de garganta e rouquidão foram avaliadas também 24 horas após a anestesia. RESULTADOS: Os valores da pressão no balonete em G2 foram significativamente menores do que os de Air em todos os tempos de estudo, a partir de 30 minutos (p < 0,001). A proporção de pacientes que reagiu ao tubo traqueal no momento da desintubação foi significantemente menor em Lido (p < 0,005). A incidência de odinofagia foi significantemente menor em Lido no primeiro dia de pós-operatório...


Subject(s)
Adolescent , Adult , Female , Humans , Middle Aged , Young Adult , Anesthetics, Local/administration & dosage , Intubation, Intratracheal/instrumentation , Lidocaine/administration & dosage , Nitrous Oxide/administration & dosage , Pharyngitis/etiology , Administration, Inhalation , Anesthesia, Inhalation , Cough/etiology , Hoarseness/etiology , Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/standards , Oxygen/administration & dosage , Pharyngitis/prevention & control , Prospective Studies , Trachea/injuries , Young Adult
8.
Rev. bras. anestesiol ; 57(2): 223-231, mar.-abr. 2007.
Article in Portuguese | LILACS | ID: lil-444048

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Os fármacos alfa2-agonistas são a cada dia mais utilizados em Anestesiologia, seja como adjuvantes ou como agentes anestésicos únicos. Atualmente, o emprego da dexmedetomidina vem se popularizando devido à sua maior seletividade aos receptores alfa2 e, também, ao seu perfil farmacocinético. O objetivo desta revisão foi fazer uma análise do emprego da dexmedetomidina em neurocirurgia. CONTEUDO: Além das considerações e revisão da literatura quanto ao emprego da dexmedetomidina especificamente em procedimentos neurocirúrgicos, foi realizada descrição dos efeitos do fármaco nos diversos sistemas do organismo. CONCLUSÕES: A dexmedetomidina tem perfil farmacocinético e farmacodinâmico que favorece seu emprego em diversos procedimentos neurocirúrgicos. A utilização clínica em procedimentos cirúrgicos com craniotomia para pinçamento de aneurisma e remoção de tumores é crescente. Além disso, seu uso em intervenções cirúrgicas funcionais é promissor.


BACKGROUND AND OBJECTIVES: The use of alpha2-adrenergic agonists is increasingly more frequent in Anesthesiology, as adjuvant or the sole anesthetic drug. Currently, dexmedetomidine is gaining popularity due to its greater selectivity for the alpha2-adrenergic receptors and its pharmacokinetic profile. The aim of this review was to analyze the use of dexmedetomidine in neurosurgery. CONTENTS: Besides considerations and review of the literature regarding the use of dexmedetomidine, specifically in neurosurgical procedures, its effects on the different organ systems are described. CONCLUSIONS: The pharmacokinetic and pharmacodynamic profile of dexmedetomidine favors its use in several neurosurgical procedures. Its use in craniotomy for the treatment of aneurysms and tumor removal is recent. Besides, its use in functional surgical interventions is promising.


JUSTIFICATIVA Y OBJETIVOS: Los fármacos alfa2-agonistas son cada día más utilizados en Anestesiología, sea como adyuvantes o como agentes anestésicos únicos. Actualmente, el empleo de la dexmedetomidina se ha venido popularizando debido a su mayor selectividad a los receptores alfa2 y, también, a su perfil farmacocinético. El objetivo de esta revisión fue hacer una análisis del empleo de la dexmedetomidina en Neurocirugía. CONTENIDO: Además de las consideraciones y de la revisión de la literatura en cuanto al empleo de la dexmedetomidina específicamente en procedimientos neuro-quirúrgicos, fue realizada una descripción de los efectos del fármaco en los diversos sistemas del organismo. CONCLUSIONES: La dexmedetomidina tiene un perfil farmacocinético y farmacodinámico que favorece su empleo en diversos procedimientos neuro-quirúrgicos. La utilización clínica en procedimientos quirúrgicos con craneotomia para el pinzamiento de aneurisma y la retirada de tumores va en aumento. Además, su uso en intervenciones quirúrgicas funcionales es promisorio.


Subject(s)
Dexmedetomidine/administration & dosage , Dexmedetomidine/pharmacokinetics , Anesthesia/methods , Neurosurgery/instrumentation
9.
Rev. bras. anestesiol ; 56(2): 189-199, mar.-abr. 2006. ilus
Article in Portuguese | LILACS | ID: lil-431064

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Descrever as principais causas de rouquidão após intubação traqueal. CONTEUDO: A rouquidão após intubação traqueal é um dos sintomas mais freqüentes no pós-operatório, podendo apresentar durações variáveis, dependendo dos fatores causais e da gravidade do comprometimento das estruturas da laringe. Foi realizada uma breve revisão das estruturas anatômicas da laringe, em que foram descritas as principais lesões traumáticas desse órgão, decorrentes da intubação traqueal e salientou-se a importância dos seus cuidados, bem como do diagnóstico e tratamento precoces. CONCLUSÕES: As lesões traumáticas das estruturas da laringe durante a intubação são causas freqüentes de rouquidão, sendo importante o diagnóstico precoce e a adoção de medidas preventivas.


Subject(s)
Humans , Postoperative Complications/etiology , Voice Disorders/etiology , Intubation, Intratracheal/adverse effects , Hoarseness/etiology
10.
Rev. bras. anestesiol ; 56(1): 28-33, jan.-fev. 2006. tab, graf
Article in English, Portuguese | LILACS | ID: lil-426141

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: O uso espinhal de opióides pode causar alguns efeitos indesejáveis, dentre os quais, o mais freqüente é o prurido que, apesar de sua baixa morbidade, pode proporcionar desconforto intenso ao paciente e prolongar o período de internação. O objetivo deste estudo foi avaliar diversas opções terapêuticas no tratamento profilático do prurido após administração de sufentanil por via subaracnóidea. MÉTODO: Foram distribuídos de maneira aleatória, por sorteio, 100 pacientes a serem submetidos à intervenção cirúrgica não-obstétricas em cinco grupos, de acordo com o tratamento utilizado: controle (ausência de tratamento - C); droperidol 2,5 mg (D); nalbufina 10 mg (N); associação dos medicamentos anteriores (DN) e ondansetron 8 mg (O). O prurido foi avaliado quantitativamente 30 minutos, 1, 2, e 3 horas após a administração subaracnóidea de sufentanil. RESULTADOS: Os grupos C e O apresentaram incidência significativamente maior de prurido em relação aos grupos D, N e DN. Entretanto, não houve diferença significativa na necessidade de tratamento específico com naloxona entre os grupos tratados. CONCLUSÕES: O tratamento profilático do prurido neste estudo, independentemente do fármaco utilizado, diminuiu sua intensidade e limitou a necessidade de tratamento específico com naloxona.


Subject(s)
Humans , Adolescent , Adult , Middle Aged , Aged , Pruritus/drug therapy , Sufentanil/adverse effects , Ondansetron/therapeutic use , Droperidol/therapeutic use , Nalbuphine/therapeutic use , Drug Combinations
12.
Rev. bras. anestesiol ; 54(6): 755-768, nov.-dez. 2004. tab, graf
Article in English, Portuguese | LILACS | ID: lil-392834

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A incidência e causas de parada cardíaca (PC) durante a anestesia variam e são difíceis de comparar diante dos diversos métodos usados nos estudos. A pesquisa teve como objetivo estudar todas as PC ocorridas no intra e pós-operatório, durante um período de sete anos, de 1996 a 2002, em hospital de ensino de atendimento terciário para determinar incidência e causas da PC. MÉTODO: A incidência prospectiva de PC ocorrida durante a anestesia em 40.941 pacientes consecutivos foi identificada, utilizando-se um Banco de Dados. Todos os casos de PC e óbito foram revisados por uma Comissão, para determinar o fator desencadeante da PC ou óbito. A incidência de PC foi calculada em relação à idade, sexo, estado físico, segundo a classificação da ASA, tipo de atendimento, fatores desencadeantes, como alteração do estado físico do paciente e complicações cirúrgicas e anestésicas, tipo de anestesia e evolução para óbito. RESULTADOS: Ocorreram 138 PC (33,7:10.000), sendo a maioria em recém-nascidos, crianças até um ano e idosos, no sexo masculino (65,2 por cento), em pacientes com estado físico ASA III ou superior, em atendimento de emergência e durante anestesia geral. Alterações do estado físico foram o principal fator de PC (23,9:10.000), seguidas de complicações cirúrgicas isoladamente (4,64:10.000) ou associadas a alterações do estado físico (2,44:10.000) e da anestesia isoladamente (1,71:10.000) ou associadas a alterações do estado físico (0,98:10.000). O risco de óbito relacionado à anestesia como fator principal ou contributivo foi igual para ambos (0,49:10.000). As principais causas da mortalidade associada à anestesia foram os problemas ventilatórios (45,4 por cento), eventos relacionados à medicação empregada (27,3 por cento), aspiração pulmonar (18,2 por cento) e hidratação excessiva (9,1 por cento). CONCLUSÕES: A incidência de PC durante a anestesia ainda continua elevada. A maioria das PC e óbitos associados à anestesia foi relacionada ao manuseio das vias aéreas e à administração de medicamentos e anestésicos.


Subject(s)
Humans , Postoperative Care/methods , Tertiary Healthcare , Preoperative Care/methods , Heart Arrest/epidemiology , Anesthesia , Epidemiology, Descriptive , Incidence , Prospective Studies
13.
Rev. bras. anestesiol ; 53(6): 802-807, nov.-dez. 2003. graf
Article in Portuguese | LILACS | ID: lil-352234

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A sedação de dependentes de álcool e drogas em Unidades de Terapia Intensiva (UTI) é um desafio pela elevada incidência de tolerância às drogas sedativas e da elevada freqüência de síndromes de abstinência. O objetivo deste relato é mostrar um caso de paciente jovem admitido na UTI que desenvolveu síndrome de abstinência alcoólica e tolerância às drogas sedativas, solucionadas somente após o uso de clonidina. RELATO DO CASO: Paciente do sexo masculino, 18 anos, dependente de álcool, tabaco, cocaína e maconha, vítima de acidente por arma de fogo, foi admitido na UTI no 1º dia de pós-operatório de enterectomia, após aspiração de conteúdo gástrico durante reintubação traqueal. Evolução clínica: drogas vasoativas até o 4º dia de internação e broncopneumonia bilateral com derrame pleural e necessidade de ventilação artificial até o 15º dia. O esquema de sedação inicial utilizado foi a associação de midazolam e fentanil. A partir do 4º dia, o paciente apresentou vários episódios de agitação psicomotora, mesmo com a associação de lorazepam no 6º dia. No 9º dia, o paciente recebeu as maiores doses dos fármacos, mas permanecia agitado. Optou-se pela associação de dexmedetomidina, que reduziu as doses das outras drogas em 35 por cento e diminuiu a agitação. No 12º dia, o midazolam e a dexmedetomidina foram substituídos pela infusão de propofol, com piora do quadro. No 13º dia, foi associada clonidina ao esquema de sedação, com resolução do quadro de agitação. No 14º dia, o propofol foi suspenso, sendo mantida a infusão de fentanil e reintroduzida a infusão de midazolam, com doses respectivamente 75 por cento e 65 por cento menores em relação ao pico de uso destas drogas. No 15º dia, o paciente foi extubado e teve alta da UTI. CONCLUSÕES: A droga de escolha para o tratamento da síndrome de abstinência alcoólica é o benzodiazepínico...


BACKGROUND AND OBJECTIVES: Sedation of patients with past history of alcohol and drug abuse in Intensive Care Units (ICU) is a challenge due to the high incidence of sedative drugs tolerance and withdrawal syndromes. This report aimed at describing a case of a young patient admitted to the ICU who developed alcohol withdrawal syndrome and tolerance to sedatives, resolved only after clonidine administration. CASE REPORT: Male patient, 18 years old, alcohol, tobacco, cocaine and marijuana abuser, victim of firearm accident, who was admitted to the ICU in the first post-enterectomy day, after gastric content aspiration during tracheal re-intubation. Clinical evolution was: vasoactive drugs up to the 4th day; bilateral bronchopneumonia with pleural effusion and need for artificial ventilation up to the 15th day. Initial sedation scheme was the association of midazolam and fentanyl. As from the 4th day, patient presented with several psychomotor agitation episodes, even after the association of lorazepam in the 6th day. In the 9th day, patient received the largest doses but remained agitated. Dexmedetomidine was associated, which has decreased other drug doses in 35% and has improved agitation. In the 12th day, midazolam and dexmedetomidine were replaced by propofol infusion with worsening of agitation. In the 13th day, clonidine was associated to the sedation scheme with total resolution of agitation. Propofol was withdrawn in the 14th day, fentanyl was maintained and midazolam infusion was restarted, with doses 75% and 65% lower as compared to peak doses of such drugs. Patient was extubated in the 15th day and was discharged from ICU. CONCLUSIONS: Benzodiazepines should remain the drugs of choice for the treatment of acute alcohol withdrawal syndrome...


JUSTIFICATIVA Y OBJETIVOS: La sedación de dependientes de alcohol y drogas en Unidades de Terapia Intensiva (UTI) es un desafío por la elevada incidencia de tolerancia a las drogas sedativas y de la elevada frecuencia de síndromes de abstinencia. El objetivo de este relato es mostrar un caso de un paciente joven admitido en la UTI que desarrolló síndrome de abstinencia alcohólica y tolerancia a las drogas sedativas, solucionadas solamente después del uso de clonidina. RELATO DEL CASO: Paciente del sexo masculino, 18 años, dependiente de alcohol, tabaco, cocaína y mariguana, víctima de accidente por arma de fuego, fue admitido en la UTI en el 1º día de post-operatorio de enterectomía, después de aspiración de contenido gástrico durante reintubación traqueal. Evolución clínica: drogas vasoactivas hasta el 4º día de internación y broncopneumonia bilateral con derrame pleural y necesidad de ventilación artificial hasta el 15º día. El esquema de sedación inicial utilizado fue la asociación de midazolan y fentanil. A partir del 4º día, el paciente presentó varios episodios de agitación psicomotora, mismo con la asociación de loracepam en el 6° día. En el 9° día, el paciente recibió las mayores dosis de los fármacos, más permanecía agitado. Se optó por la asociación de dexmedetomidina, que redujo las dosis de las otras drogas en 35% y diminuyó la agitación. En el 12° día, el midazolan y la dexmedetomidina fueron substituidos por la infusión de propofol, con empeoramiento del cuadro. En el 13° día, fue asociada clonidina al esquema de sedación, con resolución del cuadro de agitación. En el 14° día, el propofol fue suspenso, siendo mantenida la infusión de fentanil y reintroducida la infusión de midazolan, con dosis respectivamente 75% y 65% menores en relación al pico de uso de estas drogas. En el 15° día, el paciente fue extubado y tuvo alta de la UTI. CONCLUSIONES: La droga escogida para el tratamiento del síndrome de abstinencia alcohólico es el benzodiazepínico...


Subject(s)
Humans , Male , Adolescent , Alcoholism/drug therapy , Clonidine/therapeutic use , Substance Withdrawal Syndrome/drug therapy
14.
Rev. bras. anestesiol ; 53(5): 561-572, set.-out. 2003. ilus, tab
Article in Portuguese, English | LILACS | ID: lil-350898

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Dados da literatura sugerem que a clonidina, um agonista alfa2-adrenérgico, em associação com a bupivacaína, na anestesia subaracnóidea alta pode aumentar a incidência de hipotensão e bradicardia. O objetivo desta pesquisa foi verificar o potencial sinergismo entre diferentes doses de clonidina, de 45 e 75 'g, e bupivacaína hiperbárica nas características e nos efeitos hemodinâmicos do bloqueio subaracnóideo alto (T4). MÉTODO: Em estudo aleatório e duplamente encoberto, foram avaliados 60 pacientes estado físico ASA I, submetidos à cirurgia do abdômen inferior e membros inferiores. Os pacientes foram submetidos à anestesia subaracnóidea, com bupivacaína hiperbárica a 0,5 por cento (17,5 mg - 3,5 ml) mais a associação das seguintes drogas: grupo Controle (n = 20) - solução fisiológica (0,5 ml); grupo Clon 45 (n = 20) - clonidina, na dose de 45 'g (0,3 ml), associada à solução fisiológica (0,2 ml); grupo Clon 75 (n = 20) - clonidina, na dose de 75 'g (0,5 ml). A cirurgia somente foi realizada quando o nível do dermátomo atingido pelo bloqueio analgésico foi de T4. RESULTADOS: A latência dos bloqueios analgésico e motor da anestesia subaracnóidea não diferiu significativamente entre os grupos (p > 0,05). Ambas as doses de clonidina prolongaram, de maneira significativa, a duração do bloqueio analgésico em T8 e do bloqueio motor grau 3 (determinado pela escala modificada de Bromage) (p < 0,05). A incidência de hipotensão arterial no per-operatório foi evidente somente no grupo Clon 75, em relação ao grupo Controle (p < 0,05), com o Clon 45 apresentando incidência intermediária entre os demais grupos. Não houve diferença significante entre os grupos em relação à bradicardia (p > 0,05)...


BACKGROUND AND OBJECTIVES: Published data suggest that clonidine, an a2-adrenergic agonist, in association with bupivacaine, may increase the incidence of intraoperative hypotension and bradycardia during high-level spinal anesthesia. This study aimed at determining the synergistic potential of two clonidine doses (45 and 75 µg) and hyperbaric bupivacaine on characteristics and hemodynamic effects of high-level (T4) spinal anesthesia. METHODS: Participated in this randomized double-blind study, 60 ASA I patients scheduled for lower abdominal and limb surgery. Spinal anesthesia was induced with 17.5 mg (3.5 ml) of 0.5% hyperbaric bupivacaine plus the association of the following drugs: Control group (n = 20) - 0.5 ml isotonic saline solution; Clon 45 group (n = 20) - 45 µg (0.3 ml) clonidine + 0.2 ml isotonic saline solution; and Clon 75 (n = 20) - 75 µg (0.5 ml) clonidine. Surgery was only started when high-level (T4) analgesia was consistently obtained. RESULTS: Sensory and motor block onset did not significantly differ among groups (p > 0.05). Both clonidine doses significantly prolonged analgesic block at T8 and motor block level 3 duration (determined by modified Bromage scale) (p < 0.05). Intraoperative arterial hypotension was observed only in Clon 75 group as compared to Control group (p < 0.05), while Clon 45 group had intermediate incidence between both groups. There was no significant difference among groups in bradycardia (p > 0.05)...


JUSTIFICATIVA Y OBJETIVOS: Los datos de la literatura sugieren que la clonidina, un agonista a2-adrenérgico, en asociación con la bupivacaína, en la anestesia subaracnoidea alta puede aumentar la incidencia de hipotensión y bradicardia. El objetivo de esta pesquisa fue verificar el potencial sinergismo entre dosis diferentes de clonidina, de 45 y 75 µg, y bupivacaína hiperbárica en las características y en los efectos hemodinámicos del bloqueo subaracnoideo alto (T4). MÉTODO: En estudio aleatorio y duplamente encubierto, fueron evaluados 60 pacientes estado físico ASA I, sometidos a cirugía del abdomen inferior y miembros inferiores. Los pacientes fueron sometidos a anestesia subaracnoidea, con bupivacaína hiperbárica a 0,5% (17,5 mg - 3,5 ml) más la asociación de las siguientes drogas: grupo Control (n = 20) - solución fisiológica (0,5 ml); grupo Clon 45 (n = 20) - clonidina, en la dosis de 45 µg (0,3 ml), asociada a la solución fisiológica (0,2 ml); grupo Clon 75 (n = 20) - clonidina, en la dosis de 75 µg (0,5 ml). La cirugía solamente fue realizada cuando el nivel del dermátomo atingido por el bloqueo analgésico fue de T4. RESULTADOS: A latencia de los bloqueos analgésico y motor de la anestesia subaracnóidea no discordó significativamente entre los grupos (p > 0,05). Ambas dosis de clonidina prolongaron, de manera significativa, la duración del bloqueo analgésico en T8 y del bloqueo motor grado 3 (determinado por la escala modificada de Bromage) (p < 0,05). La incidencia de hipotensión arterial en el per-operatorio fue evidente solamente en el grupo Clon 75, en relación al grupo Control (p < 0,05), con el Clon 45 presentando incidencia intermediaria entre los demás grupos. No hubo diferencia significativa entre los grupos en relación a la bradicardia (p > 0,05)...


Subject(s)
Humans , Anesthesia, Conduction/methods , Bupivacaine/administration & dosage , Clonidine/administration & dosage , Drug Therapy, Combination , Hemodynamics
15.
Rev. bras. anestesiol ; 51(1): 17-27, jan.-fev. 2001. ilus, tab, graf
Article in Portuguese, English | LILACS | ID: lil-278481

ABSTRACT

Justificativa e Objetivos: A hiperrinsuflaçäo do balonete do tubo traqueal, causada pela rápida passagem do óxido nitroso, pode causar lesöes traqueais. O objetivo deste trabalho é comparar as pressöes em balonetes de tubos traqueais, contendo ou näo válvula reguladora da pressäo, durante anestesia com óxido nitroso. Método: Foram medidas as pressöes nos balonetes dos tubos traqueais de 40 pacientes adultos, estado físico ASA I e II, durante anestesia com óxido nitroso (60 por cento) em oxigênio (40 por cento), como segue: G1 (n= 20), pacientes intubados com tubos traqueais convencionais com balonetes de baixa pressäo (Portex Blue-Line, Inglaterra); G2 (n = 20), pacientes intubados com tubos traqueais dotados de válvula reguladora de pressäo de Lanz (Mallinckrodt, EUA) Em ambos os grupo, a insuflaçäo dos balonetes foi feita com ar, até a pressäo de 25 cm H2O. A medida da pressäo no balonete foi realizada através de manômetro (Mallinckrodt, EUA) antes e após 30, 60, 90 e 120 minutos do início da inalaçäo de óxido nitroso. Resultados: Após a administraçäo de óxido nitroso, as pressöes nos balonetes dos tubos traqueais aumentaram somente em G1, ultrapassando o valor crítico de 30 cm H2O para o fluxo sangüíneo da mucosa traqueal, já aos 30 minutos do estudo. Em G2, as pressöes nos balonetes diminuíram significativamente aos 30 minutos, permanecendo estáveis nos momentos seguintes, acima de 20 cm H2O (p<0,002). Houve diferença significante entre os grupos em todos os tempos estudados (p<0,0001)


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/instrumentation , Pressure , Anesthesiology/instrumentation , Monitoring, Physiologic/instrumentation
16.
São Paulo med. j ; 117(6): 243-7, Nov. 1999.
Article in English | LILACS | ID: lil-252286

ABSTRACT

CONTEXT: High compliance endotracheal tubes cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage. OBJECTIVE: We tested the hypothesis that endotracheal tube cuff pressures are routinely high (above 40 cmH2O) in the Post Anesthesia Care Unit (PACU) or Intensive Care Units (ICU). DESIGN: Cross-sectional study. SETTING: Post anesthesia care unit and intensive care unit. PARTICIPANTS: We measured endotracheal tubes cuff pressure in 85 adult patients, as follows: G1 (n = 31) patients from the ICU; G2 (n = 32) patients from the PACU, after anesthesia with nitrous oxide; G3 (n = 22) patients from the PACU, after anesthesia without nitrous oxide. Intracuff pressure was measured using a manometer (Mallinckrodt, USA). Gas was removed as necessary to adjust cuff pressure to 30 cmH2O. MAIN MEASUREMENTS: Endotracheal tube cuff pressure. RESULTS: High cuff pressure (> 40 cmH2O) was observed in 90.6 percent patients of G2, 54.8 percent of G1 and 45.4 percent of G3 (P < 0.001). The volume removed from the cuff in G2 was higher than G3 (P < 0.05). CONCLUSION: Endotracheal tubes cuff pressures in ICU and PACU are routinely high and significant higher when nitrous oxide is used. Endotracheal tubes cuff pressure should be routinely measured to minimize tracheal trauma


Subject(s)
Humans , Male , Female , Middle Aged , Intubation, Intratracheal/adverse effects , Nitric Oxide/administration & dosage , Pressure , Trachea/injuries , Cross-Sectional Studies , Postanesthesia Nursing , Sex Distribution , Intensive Care Units , Intubation, Intratracheal/instrumentation
17.
Rev. bras. oftalmol ; 58(2): 129-132, fev. 1999. tab
Article in Portuguese | LILACS | ID: lil-246915

ABSTRACT

Säo relatados 6 pacientes portadores de carcinima basocelular (CBC) localizado no canto medial e que apresentavam invasäo orbitária. Todos os pacientes apresentavam idade superior a 65 anos e apresentavam o tumor há mais de 1 ano. A lesäo possuía mais do que 4,0cm de tamanho e era recidivante em 50,0 por cento dos pacientes. Após exerese tumoral e tratamento radioterápico, houve recidiva em 22,0 por cento em segmento de no mínimo 1 ano. Os autores concluem que o tratamento dos portadores de CBC do canto interno deve ser adequado e o follow-up bem feito devido ao risco de invasäo orbitária


Subject(s)
Humans , Female , Male , Aged , Carcinoma, Basal Cell , Eyelid Neoplasms/radiotherapy
SELECTION OF CITATIONS
SEARCH DETAIL