Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Arq. bras. oftalmol ; 78(4): 220-223, July-Aug. 2015. ilus
Article in English | LILACS | ID: lil-759259

ABSTRACT

ABSTRACTPurpose:To evaluate the influence of size and shape of neodymium:yttrium aluminum- Garnet (Nd:YAG) laser capsulotomy on visual acuity and refraction.Methods:We retrospectively evaluated 85 eyes of 67 patients treated with Nd:YAG laser posterior capsulotomy for posterior capsule opacification (PCO). The mean age of included patients was 57.57 ± 9.26 (mean ± standard deviation, 38-75 years). The mean interval between surgery and Nd:YAG laser capsulotomy was 26.09 ± 7.08 (10-38) months. Patients were divided into four groups according to the shape and size of capsulotomy. Groups comprised patients with cruciate shape capsulotomies with openings of less than or equal to 3.5 mm (Group 1) or greater (Group 2) and patients with circular shape capsulotomies with openings of less than or equal to 3.5 mm (Group 3) or greater (Group 4).Results:The mean number and energy of laser firings were significantly higher in Group 4 (p=0.00), and significantly lower in Group 1 (p=0.00), compared with that in other groups. Pre-procedural and post-procedural mean spherical equivalent (SE) values were significantly higher in Group 1 (p=0.026 and p=0.011, respectively). No statistical difference in best-corrected visual acuities (BCVA) or intraocular pressures (IOP) were observed between groups before (p=0.44 and p=0.452, respectively) or after capsulotomy (p=0.108 and p=0.125, respectively). A significantly higher number of patients in Group 4 (p=0.001), and a significantly lower number of patients in Group 1 (p=0.001), reported floating bodies compared with that in other groups. No significant changes in SE or intraocular pressure were observed after capsulotomy in any group (p=0.074 and p=0.856, respectively). Best-corrected visual acuity was significantly improved following capsulotomy in all groups (p<0.01).Conclusion:Cruciate shape capsulotomy with an opening of 3.5 mm or less provides the greatest improvement in visual function with minimal complications.


RESUMOObjetivo:Avaliar a influência do tamanho e forma da capsulotomia a laser de Neodímio: Ítrio-Alumínio-Granada (Nd:YAG) na acuidade visual e refração.Métodos:Oitenta e cinco olhos de 67 pacientes, com opacificação de cápsula posterior (PCO), que tinham sido submetidos a capsulotomia por laser de Nd:YAG, foram avaliadas retrospectivamente. A idade foi 57,57 ± 9,26 (média ± desvio padrão), variação 38-75 anos. O intervalo médio entre a cirurgia e a capsulotomia a laser de Nd:YAG foi 26,09 ± 7,08 (variação 10-38) meses. Os pacientes foram divididos em 4 grupos de acordo com a forma e o tamanho da capsulotomia. O grupo 1 incluiu pacientes com forma cruzada e tamanho igual ou menor do que 3,5 mm de abertura capsulotomia, Grupo 2, forma cruzada e tamanho maior do que 3,5 mm, Grupo 3, forma circular e tamanho igual ou menor do que 3,5 mm e Grupo 4, forma circular e tamanho superior a 3,5 mm.Resultados:A quantidade média de energia utilizada e tiros aplicadas foram significativamente maiores no Grupo 4 (p=0,00) e significativamente menores no grupo 1 (p=0,00). O equivalente esférico (SE), antes e após o procedimento, foi significativamente mais elevado no Grupo 1 (p=0,026, p=0,011). Não houve diferença estatística entre os grupos em relação à acuidade visual melhor corrigida (BCVA) e pressão intraocular (IOP) antes do procedimento (p=0,44, p=0,452) e após o procedimento (p=0,108, p=0,125). O número de pacientes com sintomas de moscas volantes foi significativamente maior no grupo 4 (P=0,001) e significativamente inferior no grupo 1 (p=0,001). SE e IOP após o procedimento não foram estatisticamente diferentes daqueles antes do procedimento (p=0,074, p=0,856, respectivamente) em todos os grupos. BCVA após o procedimento foi significativamente melhor do que antes do procedimento (p=0,00) em todos os grupos.Conclusões:Em conclusão, para complicações mínimas e máximas funções visuais, o tamanho ótimo capsulotomia deve ser igual a ou menor do que 3,5 mm e deve ser em forma cruzada.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Cataract Extraction/adverse effects , Lasers, Solid-State/therapeutic use , Posterior Capsulotomy/methods , Cataract/pathology , Lens Capsule, Crystalline , Lens Implantation, Intraocular , Postoperative Complications , Refraction, Ocular , Retrospective Studies , Visual Acuity
3.
Arq. bras. oftalmol ; 77(5): 280-284, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-730377

ABSTRACT

Purpose: To compare the subfoveal choroidal thickness (SFCT) of patients with different severities of obstructive sleep apnea/hypopnea syndrome (OSAHS) and normal controls via enhanced depth imaging optical coherence tomography (EDI-OCT). Methods: In this retrospective, case-control study, 49 eyes from 49 patients that had undergone polysomnography were included. SFCT of the horizontal and vertical line scans were manually measured for all eyes based on EDI-OCT images. Two separate analyses were performed according to different apnea/hypopnea index (AHI) groupings. Initial testing was conducted using non-OSAHS, mild OSAHS (5≤AHI<15), moderate OSAHS (15≤AHI<30), and severe OSAHS (AHI≥30) patient groupings, while secondary testing used non-OSAHS, mild OSAHS (5≤AHI<15), and moderate/severe OSAHS (AHI≥15) patient groupings. Results: The mean SFCT was 314.5 μm in the non-OSAHS patients (n=14), 324.5 μm in the mild OSAHS patients (n=15), 269.3 μm in the moderate OSAHS patients (n=11), and 264.3 μm in the severe OSAHS patients (n=9). SFCT between the four groups revealed no significant differences despite a trend towards slight thinning in the severe group (P=0.08). When the moderate and severe groups were merged and compared with the mild OASHS and non-OSAHS groups, SFCT of the moderate/severe group was found to be significantly thinner than that of the mild group (P=0.016). A negative significant correlation was found between SFCT and AHI in OSAHS patients (r=0.368, P=0.033). Conclusions: In patients with moderate/severe OSAHS, EDI-OCT revealed a thinned SFCT. Other accompanying systemic or ocular diseases may induce perfusion and oxygenation deficiency in eyes of OSAHS patients. Further studies are required in order to determine the exact relationships between ocular pathologies and clinical grades of OSAHS. .


Objetivo: Comparar a espessura da coróide subfoveal (subfoveal choroidal thickness - SFCT) de pacientes com diferentes gravidades de síndrome de apnéia/hipopnéia obstrutiva do sono (obstructive sleep apnea/hypopnea syndrome - OSAHS) e controles normais por meio da tomografia de coerência óptica com profundidade de imagem aprimorada (enhanced depth imaging optical coherence tomography - EDI-OCT). Métodos: Neste estudo retrospectivo caso-controle, foram incluídos 49 olhos de 49 pacientes submetidos a polissonografia. A espessura da coroide subfoveal nas linhas horizontais e verticais de rastreamento foi medida manualmente em todos os olhos, com base nas imagens de EDI-OCT. De acordo com o índice de apnéia/hipopnéia (AHI), duas análises separadas foram realizadas: com dados de pacientes sem OSAHS, com OSAHS leve (5≤AHI<15), com OSAHS moderado (15≤AHI<30) e com OSAHS grave (AHI≥30) e com dados de pacientes sem OSAHS, com OSAHS leve (5≤AHI<15) e com OSAHS moderada e grave (AHI≥15). Resultados: A média de SFCT foi de 314,5 μm nos pacientes sem OSAHS (n=14), 324,5 μm em pacientes com OSAHS leve (n=15), 269,3 μm em pacientes com OSAHS moderada (n=11) e 264,3 μm em pacientes com OSAHS grave (n=9). Não houve diferença significativa entre a SFCT dos quatro grupos, apesar do discreto afinamento no grupo severo (p=0,08). Quando os grupos moderados e graves foram fundidos e comparados com os grupos sem OSAHS e com OSAHS leves, SFCT do grupo moderado/ grave foi significativamente mais fino do que o do grupo leve (p=0,016). Foi encontrada uma correlação negativa significativa entre SFCT e AHI em pacientes com OSAHS (r=0,368, p=0,033). Conclusões: Em pacientes com OSAHS moderada/grave, a EDI-OCT revelou um SFCT afinado. Outras doenças sistêmicas ou oculares associadas podem induzir a deficiência ...


Subject(s)
Humans , Sleep Apnea Syndromes , Choroid/pathology , Tomography, Optical Coherence , Tonometry, Ocular , Polysomnography
4.
Arq. bras. oftalmol ; 77(3): 148-151, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-723842

ABSTRACT

Purpose: To investigate choroidal thickness in healthy pregnant women during different trimesters using enhanced depth imaging optical coherence tomography (EDI-OCT). Methods: This prospective study included 90 healthy pregnant women in their first, second, or third trimester (groups 1, 2, and 3, respectively) and 30 non-pregnant healthy women (group 4). The age range for all groups was 18-40 years. Spectral domain optical coherence tomography scans were obtained to estimate the average choroidal thickness. Using EDI-OCT, we measured choroidal thickness manually from the outer border of the retinal pigment epithelium to the inner scleral border at the subfovea, 3 mm temporal, and 3 mm nasal to the fovea. Differences among groups were analyzed by one-way ANOVA. Results: We found a statistically significant difference between groups 2 and group 4 for subfoveal, temporal, and nasal mean choroidal thickness (p=0.007, p<0.001, p=0.026, respectively). The mean choroidal thickness for group 2 was 395 ± 80 µm, 338 ± 74 µm, and 233 ± 61 µm at the regions subfoveal, temporal, and nasal to the fovea, respectively. In comparison, the mean choroidal thickness for group 4 was 335 ± 86 µm, 274 ± 54 µm, and 200 ± 53 µm at the regions subfoveal, temporal, and nasal to the fovea, respectively. No statistically significant differences were found for choroidal thickness among groups 1-4 (p=0.214, p=0.177, p=0.094, respectively) and between groups 3-4 (p=0.105, p=0.261, p=0.695, respectively) for all measured points. Conclusion: Our results suggest that choroidal thickening can occur at the regions subfoveal, temporal, and nasal to the fovea in the second trimester. .


Objetivo: Investigar a espessura da coroide em gestantes saudáveis durante os diferentes trimestres utilizando tomografia de coerência óptica com profundidade de imagem aprimorada (EDI-OCT). Métodos: Este estudo prospectivo incluiu 90 gestantes saudáveis nos primeiro, segundo e terceiro trimestres da gravidez (grupos 1, 2 e 3, respectivamente) e 30 mulheres saudáveis não-gestantes (grupo 4) com faixa etária de 18-40 anos de idade. Foi realizada tomografia de coerência óptica espectral para estimar a espessura média da coroide. A espessura da coroide foi medida manualmente da borda externa do epitélio pigmentar da retina até o limite interno da esclera nas regiões subfoveal, 3 mm temporal e 3 mm nasal à fóvea utilizando EDI-OCT. As diferenças entre os grupos foram analisadas com o teste ANOVA unicaudal. Resultados: Houve diferença estatística significativa na espessura média da coroide entre os grupos 2 e 4 nas regiões subfoveal, temporal e nasal à fóvea (p=0,007; p<0,001; p=0,026, respectivamente). A espessura média da coroide no grupo 2 foi: 395 ± 80 µm, 338 ± 77 µm e 233 ± 61 µm nas regiões subfoveal, temporal e nasal à fóvea, respectivamente. Em comparação, a espessura média da coroide no grupo 4 foi de: 335 ± 86 µm, 275 ± 54 µm e 200 ± 53 µm, nas regiões subfoveal, temporal e nasal à fóvea, respectivamente. Não foi encontrada diferença estatística significativa entre os grupos 1-4 (p=0,214, p=0,177, p=0,094, respectivamente) e os grupos 3-4 (p=0,105, p=0,261, p=0,695 respectivamente), para todas as medidas. Conclusão: Nossos resultados sugerem que há espessamento da coroide nas regiões subfoveal, temporal e nasal à fóvea no segundo trimestre gestacional. .


Subject(s)
Adolescent , Adult , Female , Humans , Pregnancy , Young Adult , Choroid/anatomy & histology , Tomography, Optical Coherence/methods , Analysis of Variance , Blood Pressure/physiology , Gestational Age , Organ Size , Pregnancy Trimesters , Prospective Studies , Reference Values , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL