Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Rio de Janeiro; s.n; 2012. 89 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-866830

ABSTRACT

Esta investigação objetivou a eficácia antimicrobiana de agentes desinfetantes utilizados na desinfecção dos instrumentos endodônticos, durante o período transoperatório do tratamento endodôntico. A atividade antimicrobiana dos desinfetantes álcool isopropílico, acetona e ácido peracético (PAA) foi avaliada sobre microrganismos planctônicos através de teste de contato (time kill assay), utilizando inóculo de 9,9 X 109 a 1,2 X 1012 unidades formadoras de colônia (UFC) e por determinação da concentração bactericida mínima (CBM), usando inóculo de aproximadamente 106 UFC. Os agentes químicos também foram avaliados sobre Enterococcus faecalis (E. faecalis) ATCC 29212 cultivada em matriz de dentina (ex vivo) visando a formação de biofilme. O biofilme (organismos sésseis) microbiano foi removido com limas tipo Kerr (LK), até as lâminas estarem visualmente preenchidas. As LK contaminadas foram usadas como carreadores (logo após a contaminação ou secas dentro de uma câmara de fluxo laminar por 10 minutos). As LK carreadoras foram imersas em álcool isopropílico ou acetona ambos a 80%, ou em Ácido peracético 2%, por 30 ou 60 segundos. As limas foram posteriormente colocadas em tubos de ensaio contendo caldo Enterococcosel para observar o crescimento dos enterococos viáveis. Depois, os experimentos in vivo foram realizados com LK contaminadas por material necrótico pulpar da região cervical de dentes indicados para tratamento endodôntico. As LK contaminadas foram imersas, por 30 ou 60 segundos, em 80% de acetona ou 80% de álcool isopropílico ou 2% de PAA. As limas foram então inoculadas em tubos de ensaio contendo meio tioglicolato. Os organismos que cresceram, foram identificados após o tratamento com PAA. A corrosão mediada pelos agentes químicos também foi testada, após a incubação de LK de aço inoxidável e de NiTi por 60 minutos, medindo o peso das LK antes e depois da imersão e por microscopia eletrônica de varredura (MEV). Todos os agentes ...


This investigation aimed to evaluate the antimicrobial efficacy of disinfectant agents used to maintain the disinfection of endodontic instruments during the transoperatory period in endodontic treatment. The antimicrobial activity of disinfectants isopropyl alcohol, acetone and peracetic acid were evaluated upon planktonic micro-organisms by time kill assay (contact test) using inoculums from 9,9 X 109 to 1,2 X 1012 colony forming units (CFU) and determination of minimal bactericidal concentration (MBC), using inoculums of 106 CFU. Chemical agents were also evaluated upon Enterococcus faecalis (E. faecalis) ATCC 29212 strain grown on matrix dentin (ex vivo) for biofilm formation. Biofilm (sessile organisms) were removed with Kerr files until the blades were visually filled and contaminated K files used as carriers (shortly after contamination or dried inside a flow chamber for 10 minutes). K files carriers were immersed in 80% isopropyl alcohol, 80% acetone or in 2% peracetic acid for 30 or 60 seconds. The files were subsequently dispensed into test tubes containing Enterococcosel broth to observe the growth of viable enterococci. Thereafter, in vivo experiments were performed with K files contaminated with pulp necrotic material from cervical region of teeth indicated to endodontic treatment. The contaminated K files were immersed for 30 or 60 seconds in 80% acetone, 80% isopropyl alcohol and 2% peracetic acid. The files were then inoculated into test tubes containing tioglycolate medium. The organisms that grew after peracetic acid treatment were identified. The corrosion mediated by the chemical agents was also tested after incubation of stainless steel and NiTi K files for 60 minutes, by measuring the weight of K-files before and after immersion, and by scanning electron microscopy (SEM). All chemical agents were capable to eliminate or reduce bacterial viability of planktonic Gram-negative and Gram-positive species, though the activity ...


Subject(s)
Acetone , Disinfectants , Disinfection/methods , Endodontics/instrumentation , Peracetic Acid , Biofilms , Culture Media , Efficacy , Enterococcus faecalis , Microscopy, Electron, Scanning
2.
Rio de Janeiro; s.n; 2012. 89 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: lil-712805

ABSTRACT

Esta investigação objetivou a eficácia antimicrobiana de agentes desinfetantes utilizados na desinfecção dos instrumentos endodônticos, durante o período transoperatório do tratamento endodôntico. A atividade antimicrobiana dos desinfetantes álcool isopropílico, acetona e ácido peracético (PAA) foi avaliada sobre microrganismos planctônicos através de teste de contato (time kill assay), utilizando inóculo de 9,9 X 109 a 1,2 X 1012 unidades formadoras de colônia (UFC) e por determinação da concentração bactericida mínima (CBM), usando inóculo de aproximadamente 106 UFC. Os agentes químicos também foram avaliados sobre Enterococcus faecalis (E. faecalis) ATCC 29212 cultivada em matriz de dentina (ex vivo) visando a formação de biofilme. O biofilme (organismos sésseis) microbiano foi removido com limas tipo Kerr (LK), até as lâminas estarem visualmente preenchidas. As LK contaminadas foram usadas como carreadores (logo após a contaminação ou secas dentro de uma câmara de fluxo laminar por 10 minutos). As LK carreadoras foram imersas em álcool isopropílico ou acetona ambos a 80%, ou em Ácido peracético 2%, por 30 ou 60 segundos. As limas foram posteriormente colocadas em tubos de ensaio contendo caldo Enterococcosel para observar o crescimento dos enterococos viáveis. Depois, os experimentos in vivo foram realizados com LK contaminadas por material necrótico pulpar da região cervical de dentes indicados para tratamento endodôntico. As LK contaminadas foram imersas, por 30 ou 60 segundos, em 80% de acetona ou 80% de álcool isopropílico ou 2% de PAA. As limas foram então inoculadas em tubos de ensaio contendo meio tioglicolato. Os organismos que cresceram, foram identificados após o tratamento com PAA. A corrosão mediada pelos agentes químicos também foi testada, após a incubação de LK de aço inoxidável e de NiTi por 60 minutos, medindo o peso das LK antes e depois da imersão e por microscopia eletrônica de varredura (MEV). Todos os agentes ...


This investigation aimed to evaluate the antimicrobial efficacy of disinfectant agents used to maintain the disinfection of endodontic instruments during the transoperatory period in endodontic treatment. The antimicrobial activity of disinfectants isopropyl alcohol, acetone and peracetic acid were evaluated upon planktonic micro-organisms by time kill assay (contact test) using inoculums from 9,9 X 109 to 1,2 X 1012 colony forming units (CFU) and determination of minimal bactericidal concentration (MBC), using inoculums of 106 CFU. Chemical agents were also evaluated upon Enterococcus faecalis (E. faecalis) ATCC 29212 strain grown on matrix dentin (ex vivo) for biofilm formation. Biofilm (sessile organisms) were removed with Kerr files until the blades were visually filled and contaminated K files used as carriers (shortly after contamination or dried inside a flow chamber for 10 minutes). K files carriers were immersed in 80% isopropyl alcohol, 80% acetone or in 2% peracetic acid for 30 or 60 seconds. The files were subsequently dispensed into test tubes containing Enterococcosel broth to observe the growth of viable enterococci. Thereafter, in vivo experiments were performed with K files contaminated with pulp necrotic material from cervical region of teeth indicated to endodontic treatment. The contaminated K files were immersed for 30 or 60 seconds in 80% acetone, 80% isopropyl alcohol and 2% peracetic acid. The files were then inoculated into test tubes containing tioglycolate medium. The organisms that grew after peracetic acid treatment were identified. The corrosion mediated by the chemical agents was also tested after incubation of stainless steel and NiTi K files for 60 minutes, by measuring the weight of K-files before and after immersion, and by scanning electron microscopy (SEM). All chemical agents were capable to eliminate or reduce bacterial viability of planktonic Gram-negative and Gram-positive species, though the activity ...


Subject(s)
Acetone , Disinfectants , Disinfection/methods , Endodontics/instrumentation , Peracetic Acid , Biofilms , Culture Media , Efficacy , Enterococcus faecalis , Microscopy, Electron, Scanning
3.
Rev. bras. odontol ; 68(1): 20-24, jan.-jun. 2011. tab
Article in Portuguese | LILACS, BBO | ID: lil-642767

ABSTRACT

Este estudo objetivou o isolamento e caracterização bioquímica de Enterococcus sp de canais radiculares portadores de necrose pulpar de 70 pacientes. Foram isoladas 35 amostras de Enterococcus sp em 50% dos pacientes (n = 35) com a seguinte prevalência: 33 amostras Enterococcus faecalis (94,28%), 1 amostra Enterococcus faecium (2,85%) e 1 amostra Enterococcus durans (2,85%). Dos dentes com cultura positiva, 20 apresentaram sintomatologia dolorosa. Odor fétido e secreção purulenta foram observados em três dentes (8,57%). Dos 35 pacientes com cultura positiva, quatro apresentaram edema no momento da coleta e apenas um paciente apresentou fístula. A espécie E. faecalis foi majoritária, estando relacionada aos sinais e sintomas.


Subject(s)
Humans , Endodontics , Enterococcus/isolation & purification , Gram-Positive Bacterial Infections/microbiology , Pulpitis/microbiology
4.
Rev. flum. odontol ; 17(35): 48-54, jan.-jun. 2011. tab
Article in Portuguese | LILACS, BBO | ID: lil-638417

ABSTRACT

O objetivo deste trabalho foi avaliar in vitro a eficácia dos localizadores apicais Root ZX II e NovAPEX em canais mesiovestibulares de molares inferiores nas medidas 0,5mm e 1mm aquém do forame apical. Vinte molares foram acessados coronalmente e a porção cervical dos canais foi alargada com brocas Gates Glidden e irrigados com hipoclorito de sódio 5,25%. Foram feitas 120 medições divididas em 6 grupos. As medidas reais dos canais foram tomadas com a introdução de uma lima tipo K#15 até que a ponta da lima atingisse o forame apical. Dessa medida foram subtraídos 1mm e 0,5mm e os valores registrados. Grupo 1 (n=20) medida real a 1mm aquém do ápice, Grupo 2 (n=20) medida real a 0,5mm aquém, Grupo 3 (n=20) localizador Root ZX II a 1mm aquém, Grupo 4 (n=20) localizador Root ZX II a 0,5mm aquém, Grupo 5 (n=20) localizador NovAPEX a 1mm aquém, Grupo 6 (n=20) localizado NovAPEX a 0,5mm aquém, localizadores apicais foram programados de acordo com as instruções dos fabricantes para a medição dos canais a 0,5mm e 1mm aquém do ápice, sendo que as medidas obtidas foram registradas e comparadas com as medidas reais. O teste estatístico T Student foi aplicado aos resultados e observou-se que não houve diferença estatisticamente significativa (p>0.05) entre ambos os localizadores apicais, e que os dois foram eficazes para se medir o comprimento de trabalho de canais radiculares. As porcentagens de confiabilidade dos aparelhos foram 96% para o localizador apical Root ZX II a 1mm, 98,4% a 0,5mm e 96% para o localizador apical NovAPEX a 1mm e 91,2% a 0,5mm.


The objective of the current study was to evaluate in vitro the accuracy of Root ZX II and NovAPEX apex locators in mesical buccal root canals of mandibular molars in measures 0.5 mm and 1 mm from the apical foramen. Twenty molars were coronally accessed and cervical portion of the root canals was enlarged with Gates Glidden drills and irrigated with sodium hypochlorite 5.25%. It was done 120 measurements divided into six groups. Reals measurements of the canals were taken with the introduction of a K file # 15 until the file tip reached the apical foramen. This measure were subtracted 1 mm and 0.5 mm and the values recorded. Group 1 (n = 20) the real measure 1 mm from the apex, Group 2 (n = 20) measured 0.5 mm below the real, Group 3 (n = 20) locator Root ZX II to 1mm below, Group 4 (n = 20) locator Root ZX II to 0.5 mm below, Group 5 (n = 20) locator NovAPEX to 1mm below, Group 6 (n = 20) locator NovAPEX to 0.5 mm below, apex locators were programmed according to manufacturers’ instructions for measuring cannals to 0.5 mm and 1 mm from the apex, and the measurements were recorded and compared with actual measurements. The statistical T test was applied and the results showed that there was no statistically significant difference (p> 0.05) between the two apex locators, and that both were effective for measuring the working length of root canals. The percentages of reliability of the devices were 96% for the apex locator Root ZX II to 1 mm, 98.4% to 0.5 mm and 96% for the apical NovAPEX 1 mm and 91.2% to 0.5mm.


Subject(s)
Endodontics , Odontometry
5.
Rev. flum. odontol ; 16(34): 29-35, jul.-dez. 2010. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-605628

ABSTRACT

O objetivo deste estudo foi avaliar a presença de resíduos de material obturador nas paredes dos canais radiculares após sua desobturação com a utilização de dois solventes distintos: óleo de casca de laranja e eucaliptol, com auxílio das limas manuais e do microscópio óptico. Foram utilizados 20 caninos instrumentados pela técnica Crown-Down, e posteriormente obturados com guta-percha e cimento Endofill pela técnica Híbrida de Tagger modificada. As amostras foram divididas, aleatoriamente, em dois grupos iguais, de acordo com o solvente utilizado: Grupo I – óleo de laranja e Grupo II – eucaliptol. Os canais foram desobturados com brocas Gates Glidden e limas endodônticas tipo Kerr com o auxílio dos solventes e do microscópio óptico. Clivadas as raízes, ambas as hemissecções, foram fotografadas e observadas, sendo avaliadas por três observadores calibrados, atribuindo escores a cada uma delas de acordo com a quantidade de resíduo encontrado no interior dos canais. Durante a análise fotográfica verificou-se a presença de resíduos remanescentes de material obturador nas paredes dos canais radiculares em ambos os grupos. Os resultados foram analisados através do teste de aderência e do teste U de Mann-Whitney. Não foi evidenciado uma diferença estatística significante (a nível de > 0,05), entre os dois solventes. Pôde-se concluir que o óleo de laranja e o eucaliptol mostraram-se eficazes na remoção de resíduos de material obturador nas paredes dos canais radiculares.


The aim of this study was to evaluate the presence of debris from fillings material on the canal walls, after the desobturation with the use of two solvents: orange oil and eucalyptol, with aid of the manual endodontic files and optic microscope. Twenty canines were prepared through Crown-down technique, and after obturated with gutta-percha and endofill cement through modified Hybrid of Tagger technique. The sample were divided, randomly, into two equal groups in accordance with the solvent used: group I – orange oil and group II – eucalyptol. The root canal obturations were removed with endodontic drills Gates Glidden and endodontic files type Kerr with the AID of the solvents and the optic microscope. Divided the roots in two, both pieces, were photographed and observed, being evaluated for three calibrated observers, attributing scores to each one of them in accordance of the amount of residue found in the inside of the canals. During the photographic analysis was verified the remaining presence of debris from filling material on the root canal walls in both groups. The result were analised through adherence tests and U the Mann-Whitney tests. Were evidenced a not-significant statistical differences between two solvents. Was concluded that orange oil and eucalyptol have proved effective in the removal of debris from fillings material on the root canal walls.


Subject(s)
Dental Pulp Cavity , Endodontics
6.
Pesqui. bras. odontopediatria clín. integr ; 10(2): 265-269, maio-ago. 2010.
Article in Portuguese | LILACS, BBO | ID: lil-568488

ABSTRACT

Objetivo: Analisar a contaminacao na superficie dos cones de guta-percha de diferentes fabricantes disponiveis no mercado nacional e identificar os microrganismos isolados. Metodo: 34 cones de guta-percha acessorios, provenientes de caixas lacradas ou manipuladas, foram analisados. Trinta cones foram divididos, aleatoriamente, em 6 grupos experimentais com 5 cones cada, diferenciados segundo o fabricante e a sua proveniencia (caixas lacradas ou manipuladas). Quatro cones oriundos de caixas lacrada ou manipulada foram utilizados como controles positivo (contaminado com saliva fresca) e negativo (imerso em solucao de hipoclorito de sodio a 5,25% por 1 minuto). As analises microbiologicas foram realizadas submergindo os cones em tubos contendo caldo Brain-Heart Infusion (BHI) e, posteriormente, semeando uma aliquota deste caldo em Agar sangue. A leitura foi realizada atraves da visualizacao de turvacao no caldo ou crescimento de colonias no meio solido. Os dados obtidos foram analisados pelos testes Kruskal-Wallis e Qui-Quadrado com nivel de significancia de 5%. Resultados: Observou-se crescimento bacteriano em 2 amostras. Os generos encontrados foram Staphylococcus e Bacillus. Os resultados indicaram que 6,67% dos cones de guta-percha de embalagens lacradas ou manipuladas estavam contaminados, mas nao houve diferenca estatistica entre os grupos experimentais. Conclusao: Existe um risco de contaminacao dos cones de guta-percha. Portanto estes materiais devem ser desinfetados a fim de garantir a seguranca necessaria para o sucesso do tratamento endodontico.


Objective: To analyze the contamination on the surface of gutta-percha cones from different manufacturers available in the national market and to identify the isolated microorganisms. Method: Thirty-four accessory gutta-percha cones obtained from sealed or violated packages were analyzed. Thirty cones were randomly divided in 6 experimental groups with 5 cones each, according to their manufacturer and origin (sealed or violated packages). Four cones obtained from sealed or violated packages were used as positive (contaminated with fresh saliva) and negative (immersed in 5.25% sodium hypochlorite solution for 1 minute) controls. The microbiological analyses were performed by submerging the cones in tubes containing Brain-Heart Infusion (BHI) broth, and then seeding an aliquot of this broth in agar blood. The analysis was based on the turbidity of the medium or growth of colonies in the solid medium. Data were analyzed by the Kruskal-Wallis and chi-square tests at 5% significance level. Results: There was bacterial growth in 2 samples. Staphylococcus and Bacillus genera were found. The results indicate that 6.67% of the gutta-percha cones from sealed or violated packages were contaminated without statistically significant difference between the experimental groups. Conclusion: There is a risk of contamination of gutta-percha cones. Therefore, these materials must be disinfected to ensure the safety necessary for the success of endodontic treatment.


Subject(s)
Environmental Pollution/prevention & control , Sterilization/instrumentation , Gutta-Percha , Chi-Square Distribution , Statistics, Nonparametric
7.
Rev. odontol. Univ. Cid. Sao Paulo ; 22(2): 94-103, maio-ago. 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-563875

ABSTRACT

Introdução: O objetivo deste trabalho é avaliar a eficácia, em dois períodos de tempo, do hipoclorito de sódio e da clorexidina na desinfecção de cones de guta-percha. Métodos: Foram utilizados 50 cones de gutapercha previamente contaminados com cepas de bactérias do gênero Enterococcus faecalis (ATCC 29212), em culturas puras. Para o processo de descontaminação, os cones foram divididos em quatro grupos, contendo 10 amostras cada: G1- hipoclorito de sódio (NaOCl) a 5,25% por 30 segundos; G2 - NaOCl a 5,25% por 1 minuto; G3 - clorexidina a 4% por 30 segundos; G4 - clorexidina a 4% por 1 minuto. Após esse período, os cones foram introduzidos individualmente em tubos de ensaio contendo caldo de BHI, mantidos em estufa bacteriológica a 37ºC por 72 horas, quando foi avaliada a presença de contaminação através da turvação do meio. Para o grupo-controle positivo, empregaram-se 2 cones, que foram contaminados e colocados em tubos de ensaio e, para o controle negativo, 8 cones foram apenas descontaminados, sendo colocados 2 cones em cada uma das soluções desinfetantes, por 30 segundos e por 1 minuto. Resultados: Verificou-se a ausência de crescimento bacteriano nos grupos 1, 2, 3 e 4, em todos os períodos experimentais. No controle positivo, houve 100% de contaminação e, no controle negativo, ausência de crescimento bacteriano. Conclusão: As soluções de NaOCl a 5,25% e de clorexidina a 4%, por períodos de tempo de 30 segundos e de 1 minuto, possuem efetividade antimicrobiana contra o Enterococcus faecalis, podendo ser utilizadas na desinfecção de cones de guta-percha nos tempos testados.


Introduction: The aim of this study is to evaluate the efficacy, in two period of time, of sodium hypochlorite and chlorhexidine in disinfection gutta-percha cones. Methods: 50 gutta-percha cones were used, previously contaminated with bacteria of the genus Enterococcus faecalis (ATCC 29212), in pure cultures. For the decontamination process, the cones were divided into four groups, containing 10 samples each: G1- sodium hypochlorite 5,25% for 30 seconds; G2 - sodium hypochlorite 5,25% for 1 minute; G3 - chlorhexidine 4% for 30 seconds; G4 - chlorhexidine 4% for 1 minute. After this period, all cones were immersed individually in test tubes containing Brain Heart Infusion, maintained in bacteriological incubator at 37ºC for 72 hours, when was evaluated the presence of contamination through the turbidity of BHI solution. For the positive control groups, were used 2 gutta-percha cones that were contaminated and placed directly in test tubes and for the negative control group 8 cones were just decontaminated, being placed 2 cones in each disinfectant solution, for 30 seconds and for 1 minute. Results: There was the absence of bacterial growth in groups 1, 2, 3 and 4, in all experimental periods. In the positive control group were verified 100% of contamination and in the negative control tubes wasn't verified the presence of bacterial growth. Conclusion: The solutions of 5,25% sodium hypochlorite and 4% chlorhexidine for 30 seconds and 1 minute have antimicrobial effectiveness against Enterococcus faecalis, which can be used in the disinfection of gutta-percha cones in the time tested.


Subject(s)
Chemical Compounds/classification , Disinfection/methods , Gutta-Percha/pharmacology
8.
Rev. flum. odontol ; 15(32): 15-19, jul.-dez. 2009. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-589610

ABSTRACT

O objetivo deste estudo foi avaliar a possível contaminação dos cones de guta-percha, previamente desinfectados, com hipoclorito de sódio à 5,25% por um minuto e utilizados durante a prova do cone. Foram utilizados 90 cones de guta-percha, sendo que para cada paciente foram empregados 3 cones de guta-percha, divididos em três Grupos (n=30): Grupo 1 – Controle, Grupo 2 – cone deixado na bandeja de atendimento clínico, sem ter sido introduzido no canal, Grupo 3 – cone introduzido no canal e desprezado por não ter se ajustado ao conduto. Todos os cones foram incubados individualmente em tubos contendo Tioglicolato por 7 dias à 37oC. A turvação do meio foi observada a cada 48 horas sendo esse meio semeado em placas de petri contendo meio de cultura Agar – sangue. Para análise estatística dos resultados utilizou-se o Teste de Krushal-Wallis. Pôde-se concluir que a contaminação ocorrida em um dos cones do Grupo 2 não foi estatisticamente significante e não houve contaminação nos cones do Grupo1 e nem do Grupo 3.


The aim of this study was to evaluate the possible contamination of gutta-percha cones, previously disinfecteds, with sodium Hypochlorite 5,25% for 1 minute and used during the cone test. 90 gutta-percha cones were used, and for each patient were used 3 gutta-percha cones, divided in three groups (n=30): Group 1 – Control, Group 2 – cone left in the clinical tray, without having been introduced in the root canal, Group 3 – cone introduced in the root canal and rejected for not having if adjusted exactly. All the cones were incubated individually in tubes containing thioglycolate for 7 days at 37oC. The turbidity of solution was observed to each 48 hours being sown in Petri plates containing environment of Agar-blood culture. The Krushal-Wallis test was used for the statisics of the results. Was concluded that contamination in one of the cones of Group 2 was not statistically significant and no contamination in cones of Group 1 and Group 3.


Subject(s)
Decontamination , Gutta-Percha , Sodium Hypochlorite
9.
Rev. flum. odontol ; 15(31): 44-49, jan.-jun. 2009.
Article in Portuguese | LILACS, BBO | ID: lil-589627

ABSTRACT

A terapia endodôntica em dentes decíduos é fundamental para a preservação do elemento dentário na arcada dentária infantil. A presente revisão de literatura tem como objetivo abordar alguns aspectos referentes ao diagnóstico e tratamento endodôntico em dentes decíduos dando ênfase aos medicamentos utilizados nas diferentes abordagens.


Endodontics therapy for deciduous teeth is extremely important for teeth maintenance in dental arcade of infants and depends on factors like level of cooperation from the patient, so that the procedures can be successful. Our study has the objective of reviwing the advantages of maintaining deciduous teeth in dental arcades and evaluate whether the medicaments used in pulpotomies solve its problems. We concluded that, on the contrary of what used to happen years ago, current techniques are safe when dental germs preservation is concerned. It has not yet been established an ideal medicament to be used in pulpotomies, and new studies are necessary.


Subject(s)
Dental Pulp , Endodontics , Pediatric Dentistry , Tooth, Deciduous
10.
Pesqui. bras. odontopediatria clín. integr ; 7(3): 217-222, set.-dez. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-873392

ABSTRACT

Objetivo: Comparar a qualidade e a homogeneidade da massaobturadora dos canais radiculares obtida através de duas diferentestécnicas de obturação, a Condensação Lateral e a técnica Híbridade Tagger.Método: Foram utilizados vinte caninos humanos que ficaramarmazenados em solução de Timol a 1% durante uma semana paraque permanecessem hidratados. Após a instrumentação pelatécnica Crown-Down modificada pela Universidade FederalFluminense, (utilizando como solução irrigadora o Hipoclorito deSódio a 5,25 por cento e irrigação final com EDTA 17 por cento por cinco minutos),os dentes foram divididos em dois grupos. O Grupo 1 foi obturadopela técnica da Condensação Lateral e o Grupo 2 pela técnicaHíbrida de Tagger. Em ambos os grupos o cone principal utilizadofoi o de número 50. Após obturação os dentes passaram peloprocesso de diafanização, o que os tornou transparentespossibilitando a visualização da massa obturadora. Os dentesdiafanizados foram fotografados com câmera digital acoplada aoMicroscópio Operador com aumento de 8X, 12,5X, 20X. Trêsexaminadores calibrados analisaram as fotografias após estasterem sido reveladas e atribuíram escores às amostras. Os escoresvariavam de 1 a 3 de acordo com a qualidade e homogeneidade damassa obturadora. Os resultados foram tabulados e levados paraanálise estatística pelo teste não paramétrico U de Mann-Whitney.Resultados: Foi constatado haver diferença estatística significativaentre as amostras testadas ao nível de 1%.Conclusão: A técnica Híbrida de Tagger proporcionou umaobturação mais homogênea com menos bolhas e falhas quandocomparada à técnica da Condensação Lateral.


Subject(s)
Humans , Dental Pulp Cavity , Endodontics , Gutta-Percha , Root Canal Preparation , Statistics, Nonparametric
11.
Pesqui. bras. odontopediatria clín. integr ; 6(2): 111-116, Mai.-Ago.2006. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: biblio-853700

ABSTRACT

Objetivo: Verificar qual das três marcas comerciais Tanari,Diadent ou Dentsply apresenta o diâmetro D0 ou D1coincidente com as limas manuais de aço inoxidável de mesmocalibre. Método: Para isso foi utilizado um perfilômetro,analisando-se 90 cones de guta-percha, divididos em três grupos: Grupo 1 (marca Dentsply) composto por 10 cones de calibre 30, 10 de calibre 35, 10 de calibre 40; Grupo 2 (marcaTanari) e Grupo 3 (marca Diadent), divididos da mesma forma que o Grupo 1. O Grupo 4 foi o controle, composto por 3 limas flexofile (marca Maillefer, Dentsply) de números 30, 35 e 40.Resultados: Após análise estatística e avaliação dos resultados, o valor médio, dos desvios dos calibres, obtido paraGrupo1 (Dentsply) foi 0,17643 ± 0,12165; para o Grupo 2(Tanari) foi 0,04503 ± 0,0564 e para o Grupo 3 (Diadent) foi0,06297 ± 0,10007. Conclusão: Pode-se concluir que a melhor relação entre calibre de instrumento e diâmetros D0 ou D1 doscones de guta-percha correspondeu ao Grupo 2.


Subject(s)
Dental Pulp Cavity , Endodontics/methods , Gutta-Percha/chemistry , Dental Instruments , Analysis of Variance
SELECTION OF CITATIONS
SEARCH DETAIL