Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Dental press j. orthod. (Impr.) ; 28(5): e23spe5, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1520819

ABSTRACT

ABSTRACT Introduction: Although uncommon in dentistry, the concept of the life cycle holds great importance for dental professionals in identifying crucial intervention opportunities and determining the optimal timing for treatments and procedures. Objective: To carry out a review of the literature on life cycle classifications and their distinct phases, evaluating their applicability in healthcare. Methods: A literature review was performed, searching for articles in PubMed, SciELO, National Health Library (BvB), and Google Scholar databases, as well as relevant books. The keywords "life cycle," "life stages," "human development," "age groups," and "biological age" were used. Relevant articles were selected by analyzing their titles and abstracts, and read in full to confirm their inclusion in the research. Results: Nine distinct life cycle classifications were found, each with unique criteria. Conclusion: Based on the comprehensive literature review, a novel classification was proposed (The 10-phase Life Cycle), which encompasses dental, growth, physiological aging, sociocultural, and behavioral characteristics, aiming to enhance communication among healthcare professionals, particularly those engaged in the growth, development, and aging processes of human beings.


RESUMO Introdução: Embora incomum na Odontologia, o conceito de ciclo vital é de grande importância para ajudar os profissionais dessa área a identificar oportunidades cruciais para intervenções e para determinar o momento ideal para tratamentos e procedimentos. Objetivo: Realizar uma revisão da literatura sobre as classificações do ciclo vital e suas distintas fases, avaliando sua aplicabilidade na área da saúde. Métodos: Foi realizada uma revisão da literatura, buscando artigos nas bases de dados PubMed, SciELO, Biblioteca Nacional de Saúde (BvB) e Google Acadêmico; além de livros relevantes. Foram utilizadas as palavras-chave "ciclo vital", "estágios de vida", "desenvolvimento humano", "faixas etárias" e "idade biológica". Os artigos relevantes foram selecionados por meio da análise de seus títulos e resumos e lidos na íntegra para confirmar sua inclusão na pesquisa. Resultados: Nove classificações distintas de ciclo vital foram encontradas, cada uma com critérios únicos. Conclusão: Com base nessa revisão abrangente da literatura, é proposta uma nova classificação (o ciclo vital de 10 fases) que engloba características dentárias, de crescimento, envelhecimento fisiológico, socioculturais e comportamentais, com o objetivo de melhorar a comunicação entre os profissionais da área de saúde, particularmente aqueles envolvidos nos processos de crescimento, desenvolvimento e envelhecimento do ser humano.

2.
Dental press j. orthod. (Impr.) ; 26(2): e21spe2, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1249702

ABSTRACT

ABSTRACT Introduction: This paper reviews the history of women scientists in the 'Western world', whilst highlighting the persistent socio-structural issues that have led to the hiding and masking of the participation of women in Science. Further, a reflection is made of the situation of Dentistry, specifically in the field of Orthodontics in Brazil. The difference between genders is discussed, with the intention to map the progress of women in management and leadership positions, in both the academic and professional fields. Description: In Brazil, within Dentistry and Orthodontics, despite being in a numerical majority, women are still underrepresented in the area of professional leadership. This is true for Research Groups and Research Productivity; an example being the relatively low authorship of publications in a Brazilian journal of Orthodontics. They are also underrepresented as lead presenters at professional meetings, whilst there are also few female Presidents of professional organizations and associations. Conclusion: Despite being in a numerical majority, it is also important that women act in a more co-ordinated and consistent manner to achieve greater representation in these areas. The necessary changes in the structure in order to achieve this are not only of women and for women, but they must also involve the whole of society so that leadership, rights and duties are equally distributed between the genders.


RESUMO Objetivo: Este estudo objetivou resgatar a história de mulheres cientistas nos principais períodos históricos do mundo ocidental, para realçar a questão socioestrutural persistente que "invisibiliza" e mascara a participação das mulheres na Ciência. A partir disso, realizou-se uma reflexão sobre a situação da Odontologia, especificamente na área de Ortodontia no Brasil, no que tange à diferença de gêneros, com a finalidade de mapear a atuação das mulheres nos cargos de gestão e liderança nos âmbitos acadêmico e profissional. Descrição: No Brasil, na área de Odontologia e Ortodontia, apesar de serem maioria numérica, as mulheres ainda são minoria na liderança de Grupos de Pesquisa, Produtividade em Pesquisa, na autoria de artigos em um periódico nacional da área de Ortodontia, palestrantes de congressos e na presidência de Associações de Classe. Conclusão: Apesar de apresentar maioria numérica, é importante que as mulheres atuem de maneira mais consistente. As mudanças necessárias na estrutura não são apenas da mulher e para a mulher, mas devem envolver toda a sociedade para que direitos e deveres sejam distribuídos de forma igualitária entre os sexos.


Subject(s)
Humans , Male , Female , Orthodontics , Physicians, Women , Authorship , Brazil , Leadership
3.
Dental press j. orthod. (Impr.) ; 23(6): 42-47, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-975034

ABSTRACT

ABSTRACT Objective: This clinical study was conducted in order to evaluate force decay over time of latex and non-latex orthodontic intraoral elastics. Methods: Patients (n = 15) were evaluated using latex and non-latex elastics in the periods of : 0, 1, 3, 12 and 24 hours. The rubber bands were transferred to the testing machine (EMIC DL-500 MF), and force values were recorded after stretching the elastic to a length of 25mm. Paired t test was applied and analysis of variance (ANOVA) was used to evaluate the variation of force generated. LSD (Fisher's least significant difference) post-hoc test was thus employed. Results: As regards the initial forces (zero time), the values of force for non-latex elastic were slightly higher than for the latex elastic. In the subsequent times, the forces generated by the latex elastic showed higher values. Regarding the material degradation, at the end of 24 hours the highest percentage was observed for non-latex elastic. Conclusions: The latex elastics had a more stable behavior during the studied period, compared with non-latex.


RESUMO Objetivo: o objetivo deste estudo clínico foi avaliar e comparar o comportamento dos elásticos de látex e não látex quanto à perda de força ao longo do tempo. Método: os pacientes (n = 15) foram avaliados usando ambos os tipos de material (látex e não látex) em cada tempo: 0, 1, 3, 12 e 24 horas. Os elásticos foram transferidos para a máquina de ensaios mecânicos (EMIC DL-500 MF) e os valores de força foram registrados após a distensão dos elásticos a uma distância de 25 mm. Foi aplicado o teste t pareado, e a análise de variância (ANOVA) foi realizada para verificar a variação das forças geradas em todos os tempos estudados. Em seguida, o teste post-hoc LSD (Fisher's least significant difference) foi aplicado. Resultados: quanto às forças iniciais (tempo zero), os valores de força dos elásticos não látex foram ligeiramente maiores do que dos elásticos de látex. Nos tempos subsequentes, as forças geradas pelos elásticos de látex apresentaram valores superiores às geradas pelos elásticos não látex. Em relação à degradação do material, ao fim do período de 24 horas, o maior percentual foi observado pelos elásticos não látex. Conclusões: os elásticos de látex apresentaram comportamento mais estável durante o período de estudo, em comparação aos não látex.


Subject(s)
Humans , Adult , Young Adult , Orthodontic Appliances , Rubber/chemistry , Dental Materials/chemistry , Latex/chemistry , Silicone Elastomers/chemistry , Stress, Mechanical , Tensile Strength , Materials Testing , Analysis of Variance , Orthodontic Appliance Design , Dental Stress Analysis/methods , Elasticity , Mechanical Phenomena
4.
Dental press j. orthod. (Impr.) ; 22(6): 74-85, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-891113

ABSTRACT

ABSTRACT This case report describes the treatment of a severe anterior and lateral open bite combined with multiple congenitally missing teeth. A 10-year-old girl presented with an open gonial angle, absence of lip sealing, and soft tissue pogonion retrusion. She had an open bite of 8.5 mm, agenesis of the upper right and left lateral incisors and the upper left first premolar, and transverse maxillary deficiency. Nonsurgical treatment was planned aiming at controlling the vertical pattern, establishing the correct overbite, and closing the spaces on the upper arch, to provide satisfactory occlusion and facial and dental esthetics.


RESUMO O presente caso clínico descreve o tratamento de uma mordida aberta anterior e lateral associada à ausência congênita de dentes permanentes. Paciente com 10 anos de idade, apresentava ângulo goníaco aberto, ausência de selamento labial passivo e retrusão do pogônio mole. Além disso, foi diagnosticada uma mordida aberta de 8,5 mm, agenesia de incisivos laterais superiores direito e esquerdo e de primeiro pré-molar superior esquerdo, além de deficiência transversa da maxila. O planejamento do caso envolveu um tratamento não cirúrgico, com controle vertical do crescimento, obtenção de correta sobremordida e fechamento dos espaços superiores. O caso foi finalizado com uma boa intercuspidação, contemplando a estética facial e dentária.


Subject(s)
Humans , Female , Child , Open Bite/complications , Open Bite/therapy , Malocclusion, Angle Class II/complications , Malocclusion, Angle Class II/therapy , Anodontia/complications , Anodontia/therapy , Orthodontic Appliances , Time Factors , Vertical Dimension , Bicuspid/abnormalities , Follow-Up Studies , Treatment Outcome , Open Bite/diagnostic imaging , Models, Dental , Esthetics, Dental , Facial Asymmetry/etiology , Facial Asymmetry/therapy , Facial Asymmetry/diagnostic imaging , Incisor/abnormalities , Incisor/diagnostic imaging , Malocclusion, Angle Class II/diagnostic imaging , Maxilla/abnormalities , Anodontia/diagnostic imaging
5.
Dental press j. orthod. (Impr.) ; 19(1): 77-85, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-709635

ABSTRACT

OBJECTIVE: To evaluate, in vitro, the shear bond strength presented by three brands of polycrystalline ceramic brackets and one brand of metallic bracket; verify the adhesive remnant index (ARI) after the tests, and analyze, through scanning electron microscopy (SEM) the enamel surface topography after debonding, detecting the release of mineral particles. METHODS: Sixty bovine lower incisors were used. Three ceramic brackets (Allure(r), InVu(r), and Clarity(r)) and one metallic bracket (Geneus(r)) were bonded with Transbond XT(r). Kruskal-Wallis's test (significance level set at 5%) was applied to the results of share bond and ARI. Mann Whitney's test was performed to compare the pairs of brackets in relation to their ARI. Brown-Forsythe's test (significance level set at 5%) was applied to the results of enamel chemical composition. Comparisons between groups were made with Games-Howell's and the Post-hoc tests. RESULTS: No statistically significant difference was observed in relation to the shear bond strength loads. Clarity(r) brackets were the most affected in relation to the surface topography and to the release of mineral particles of enamel (calcium ions). CONCLUSION: With regard to the ARI, there was a prevalence of score 4 (40.4%). As for enamel surface topography, the Geneus(r) bracket was the only one which did not show superficial tissue loss. The InVu(r) and Clarity(r) ones showed cohesive fractures in 33.3% and the Allure(r) in 50%, the latter being the one that presented most fractures during removal. .


OBJETIVO: avaliar, in vitro, a resistência ao cisalhamento apresentada por três marcas de braquetes ortodônticos cerâmicos policristalinos e uma marca de braquete metálico, verificando os índices de resina remanescentes (IRA) após os ensaios, e analisar, por meio de microscopia eletrônica de varredura, as topografias superficiais do esmalte após a descolagem, detectando o desprendimento de partículas minerais desse. MÉTODOS: foram utilizados 60 incisivos inferiores bovinos. Os braquetes cerâmicos (Allure, InVu e Clarity) e metálico (Geneus) foram colados utilizando-se o adesivo Transbond XT. Para os resultados referentes ao cisalhamento e ao IRA, foi utilizado o teste de Kruskal-Wallis, com nível de significância de 5%. A prova de Mann-Whtiney foi utilizada para comparar os diferentes tipos de braquetes aos pares, quanto ao IRA. Para a análise dos resultados referentes às composições químicas do esmalte, aplicou-se o teste de Brown-Forsythe, com significância de 5%. As comparações entre os grupos foram realizadas utilizando os testes Post Hoc e de Games-Hoewell. RESULTADOS: não foram observadas diferenças significativas quanto às cargas de cisalhamento. O Clarity foi o mais afetado em relação à topografia e ao desprendimento de partículas minerais do esmalte (íons Ca). CONCLUSÃO: em relação ao IRA, foi confirmada a prevalência do escore 4, com um percentual de 40,4%. Em relação à topografia superficial do esmalte, o Geneus foi o único que não apresentou perda de tecido . O InVu e o Clarity apresentaram fraturas coesivas de 33,3% de suas amostras, e o Allure de 50%, sendo o que mais fraturou durante a remoção. .


Subject(s)
Animals , Cattle , Ceramics/chemistry , Dental Bonding , Dental Alloys/chemistry , Dental Enamel/ultrastructure , Dental Materials/chemistry , Orthodontic Brackets , Adhesiveness , Calcium/analysis , Dental Enamel/chemistry , Dental Stress Analysis/instrumentation , Electron Probe Microanalysis , Equipment Failure , Materials Testing , Microscopy, Electron, Scanning , Orthodontic Appliance Design , Resin Cements/chemistry , Shear Strength , Spectrometry, X-Ray Emission , Stress, Mechanical , Surface Properties
6.
Dental press j. orthod. (Impr.) ; 19(1): 69-76, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-709644

ABSTRACT

OBJECTIVE: This research aimed at comparing the qualitative chemical compositions and the surface morphology of fracture regions of eight types of Nickel (Ni) Titanium (Ti) conventional wires, superelastic and heat-activated (GAC, TP, Ormco, Masel, Morelli and Unitek), to the wires with addition of copper (CuNiTi 27oC and 35oC, Ormco) after traction test. METHODS: The analyses were performed in a scanning electronic microscope (JEOL, model JSM-5800 LV) with EDS system of microanalysis (energy dispersive spectroscopy). RESULTS : The results showed that NiTi wires presented Ni and Ti as the main elements of the alloy with minimum differences in their composition. The CuNiTi wires, however, presented Ni and Ti with a significant percentage of copper (Cu). As for surface morphology, the wires that presented the lowest wire-surface roughness were the superelastic ones by Masel and Morelli, while those that presented the greatest wire-surface roughness were the CuNiTi 27oC and 35oC ones by Ormco, due to presence of microcavity formed as a result of pulling out some particles, possibly of NiTi. 4 The fracture surfaces presented characteristics of ductile fracture, with presence of microcavities. The superelastic wires by GAC and the CuNiTi 27oC and the heat-activated ones by Unitek presented the smallest microcavities and the lowest wire-surface roughness with regard to fracture, while the CuNiTi 35oC wires presented inadequate wire-surface roughness in the fracture region. CONCLUSION: CuNiTi 35oC wires did not present better morphologic characteristics in comparison to the other wires with regard to surfaces and fracture region. .


OBJETIVO: objetivou-se nessa pesquisa comparar as composições químicas qualitativas e as morfologias das superfícies e das regiões de fratura, após ensaios de tração, de oito tipos de fios de NiTi superelásticos e termoativados convencionais (GAC, TP, Ormco, Masel, Morelli e Unitek) aos fios com adição de cobre (CuNiTi 27°C e 35°C, da Ormco). MÉTODOS: as análises foram realizadas em microscópio eletrônico de varredura (JEOL, modelo JSM-5800 LV) com sistema de microanálise EDS (energy dispersive spectroscopy). RESULTADOS: os resultados mostraram que os fios de NiTi ensaiados apresentaram Ni e Ti como os principais elementos da liga, com diferenças mínimas em suas composições. Os fios de CuNiTi, por sua vez, apresentaram Ni e Ti, com percentual significativo de cobre (Cu). Em relação às morfologias das superfícies, os fios que apresentaram os melhores acabamentos foram os superelásticos da Masel e Morelli, e os que apresentaram os piores acabamentos foram os de CuNiTi 27°C e 35°C, da Ormco, graças à presença de microcavidades formadas devido ao arrancamento de partículas, possivelmente de NiTi 4 . As superfícies de fratura apresentaram características de fratura dúctil, com a presença de microcavidades. Os fios superelásticos da GAC e de CuNiTi 27°C, bem como os termoativados da Unitek, apresentaram as menores microcavidades e os melhores acabamentos à fratura, enquanto os fios de CuNiTi 35° apresentaram acabamentos inadequados das regiões de fratura. CONCLUSÃO: os fios de CuNiTi 35°C não apresentaram características morfológicas mais adequadas das superfícies e das regiões de fratura em relação aos demais fios. .


Subject(s)
Humans , Copper/chemistry , Dental Alloys/chemistry , Nickel/chemistry , Orthodontic Wires , Titanium/chemistry , Corrosion , Elasticity , Electron Probe Microanalysis , Hot Temperature , Materials Testing , Mechanical Phenomena , Metallurgy , Microscopy, Electron, Scanning , Spectrometry, X-Ray Emission , Stress, Mechanical , Surface Properties
7.
Dental press j. orthod. (Impr.) ; 18(6): 31-37, Nov.-Dec. 2013. ilus, tab
Article in English | LILACS | ID: lil-697728

ABSTRACT

INTRODUCTION: A wide variety of orthodontic wires made of different alloys is available to be used in orthodontic practice and may produce different clinical responses during tooth movement. OBJECTIVE: This research evaluated the alignment and leveling of lower dental arches after the use of three types of orthodontic wires. METHODS: A sample of 36 patients was randomly divided into 3 groups: stainless steel, multistranded steel and superelastic nickel-titanium, according to the first leveling arches used. In order to observe differences in tooth position and axial inclination of the lower incisors, all patients had lateral cephalometric radiographs taken before the insertion of the first arches and 2 months later. The irregularity index and the curve of Spee were measured, compared between groups and considered influential on the proclination of incisors during the initial phase of alignment and leveling. The Reflex microscope was used to measure the irregularity index, whereas the ANOVA analysis of variance was used to verify differences between groups with regard to the degree of dental alignment and leveling. RESULTS: There were significant differences between groups only at T2 for the irregularity index. CONCLUSION: The NiTi and multistranded steel wires showed greater aligning capacity when compared with stainless steel wires.


INTRODUÇÃO: uma grande variedade de fios ortodônticos, compostos por diferentes ligas, está disponível para utilização ortodôntica, podendo gerar respostas clínicas diversas, durante a movimentação dentária. OBJETIVO: este trabalho visa a avaliar o alinhamento e nivelamento das arcadas dentárias inferiores, após a utilização de três tipos de fios ortodônticos. MÉTODOS: uma amostra de 36 pacientes foi aleatoriamente dividida em três grupos, de acordo com os primeiros arcos utilizados para o alinhamento e nivelamento: aço inoxidável convencional, aço multifilamentado e de níquel-titânio superelástico. Para se avaliar as diferenças relacionadas ao posicionamento dentário e inclinação axial dos incisivos inferiores, foram obtidas radiografias cefalométricas de perfil, de todos os pacientes, em duas fases do tratamento: antes da inserção dos primeiros arcos e dois meses após a inserção dos mesmos. O índice de irregularidade dentária (IID) e a profundidade inicial de curva de Spee, fatores influentes sobre a projeção de incisivos durante a fase inicial de alinhamento e nivelamento, foram avaliados e comparados intra- e intergrupos. Para a medição do IID, foi utilizado o Reflex Microscope, possibilitando a mensuração do grau de alinhamento e nivelamento dentário em terceira dimensão. A análise de variância (ANOVA) foi utilizada para se avaliar as diferenças intergrupos em relação ao grau de alinhamento e nivelamento dentário. RESULTADOS: diferenças estatisticamente significativas intergrupos somente foram encontradas em T2, em relação ao índice de irregularidade dentária, já que os fios de NiTi e aço multifilamentado apresentaram maior capacidade de alinhamento do que os fios de aço inoxidável convencionais.


Subject(s)
Adolescent , Female , Humans , Male , Dental Alloys/chemistry , Orthodontic Appliance Design , Orthodontic Wires , Tooth Movement Techniques/instrumentation , Cephalometry/methods , Dental Arch/pathology , Elasticity , Follow-Up Studies , Incisor/pathology , Malocclusion/pathology , Malocclusion/therapy , Mandible/pathology , Nickel/chemistry , Patient Care Planning , Surface Properties , Stainless Steel/chemistry , Treatment Outcome , Titanium/chemistry
8.
Dental press j. orthod. (Impr.) ; 18(4): 35-42, July-Aug. 2013. ilus, tab
Article in English | LILACS | ID: lil-695118

ABSTRACT

OBJECTIVE: This research aimed to compare, through traction tests, eight types of superelastic and heat-activated NiTi archwires, by six trade companies (GAC, TP, Ormco, Masel, Morelli and Unitek) to those with addition of copper (CuNiTi 27ºC and 35ºC, Ormco). METHODS: The tests were performed in an EMIC mechanical testing machine, model DL10000, capacity of 10 tons, at the Military Institute of Engineering (IME). RESULTS: The results showed that, generally, heat-activated NiTi archwires presented slighter deactivation loadings in relation to superelastic. Among the archwires that presented deactivation loadings biologically more adequate are the heat-activated by GAC and by Unitek. Among the superelastic NiTi, the CuNiTi 27ºC by Ormco were the ones that presented slighter deactivation loadings, being statistically (ANOVA) similar, to the ones presented by the heat-activated NiTi archwires by Unitek. When compared the CuNiTi 27ºC and 35ºC archwires, it was observed that the 27ºC presented deactivation forces of, nearly, ⅓ of the presented by the 35ºC. CONCLUSION: It was concluded that the CuNiTi 35ºC archwires presented deactivation loadings biologically less favorable in relation to the other heat-activated NiTi archwires, associated to lower percentage of deformation, on the constant baselines of deactivation, showing less adequate mechanical behavior, under traction, in relation to the other archwires.


OBJETIVO: o objetivo dessa pesquisa foi comparar, por meio de ensaios de tração, oito tipos de fios de NiTi superelásticos e termoativados, de seis empresas comerciais (GAC, TP, Ormco, Masel, Morelli e Unitek) àqueles com adição de cobre (CuNiTi 27ºC e 35ºC, da ORMCO). MÉTODOS: os ensaios foram realizados em máquina de ensaios mecânicos, da marca EMIC, modelo DL10000, de 10 toneladas de capacidade, no Instituto Militar de Engenharia (IME). RESULTADOS: os resultados mostraram que, de forma geral, os fios de NiTi termoativados apresentaram cargas mais suaves de desativação que os superelásticos. Entre os fios que apresentaram as cargas de desativação biologicamente mais adequadas, estão os termoativados da GAC e da Unitek. Entre os fios de NiTi superelásticos, os de CuNiTi 27ºC da Ormco foram os que apresentaram as cargas mais suaves de desativação, sendo estatisticamente semelhantes (ANOVA) às apresentadas pelos fios de NiTi termoativados da Unitek. Quando comparados os fios de CuNiTi 27ºC aos de 35ºC, observou-se que os primeiros apresentaram forças de desativação de, aproximadamente, ⅓ das apresentadas pelos últimos. CONCLUSÃO: conclui-se que os fios de CuNiTi 35ºC apresentaram cargas de desativação biologicamente menos favoráveis em relação aos demais fios de NiTi termoativados, sendo associadas a percentuais inferiores de deformação, nos patamares constantes de desativação, demonstrando comportamento mecânico, sob tração, menos adequado em relação aos demais fios.


Subject(s)
Copper/chemistry , Dental Alloys/chemistry , Dental Stress Analysis/methods , Nickel/chemistry , Orthodontic Wires , Stress, Mechanical , Titanium/chemistry , Analysis of Variance , Elasticity , Hot Temperature , Materials Testing
9.
Dental press j. orthod. (Impr.) ; 18(3): 159-163, May-June 2013. ilus, tab
Article in English | LILACS | ID: lil-690013

ABSTRACT

The use of a standardized terminology in the medical sciences is essential for both clinical practice and scientific research. In addition to facilitating communication between professionals, it enhances the reliability of comparisons made between studies from different areas, thereby contributing to a higher level of scientific evidence. Examples of attempts made to standardize the terminology in other areas dedicated to the study of craniofacial morphology can be found in the literature. On the other hand, one can find in the orthodontic literature a variety of terms that render the consensus and communication between orthodontists and other researchers even more problematic. As an example, one could cite the use of the terms brachyfacial, mesofacial and dolichofacial, which form part of a cranial index terminology used to describe facial types. Thus, a reflection on the origin and differences of the terms used to describe the human facial phenotype may pave the way toward a consensus regarding the meaning that best represents the craniofacial patterns.


A padronização da nomenclatura utilizada nas ciências médicas é fundamental tanto para a prática clínica quanto para a pesquisa científica. Além de facilitar a comunicação entre os profissionais, aumenta a confiabilidade da comparação entre trabalhos de diferentes áreas, favorecendo um melhor nível de evidência científica. Exemplos de esforços, em áreas também voltadas ao estudo da morfologia craniofacial, no sentido de uniformização da terminologia podem ser encontrados na literatura médica. Por outro lado, observa-se na literatura ortodôntica uma diversidade de termos que torna mais difícil o consenso e a comunicação entre ortodontistas e demais pesquisadores. Como exemplo, pode-se citar o uso dos termos braquifacial, mesofacial e dolicofacial, terminologia relativa ao índice craniano utilizada para descrever o tipo facial. Sendo assim, a reflexão sobre a origem e diferenças dos termos utilizados para descrever o fenótipo facial humano pode ser útil ao consenso do significado que melhor representa o padrão craniofacial.


Subject(s)
Humans , Cephalometry/standards , Face/anatomy & histology , Maxillofacial Development , Skull/anatomy & histology , Terminology as Topic , Classification , Facial Bones/anatomy & histology , Interdisciplinary Communication , Somatotypes
10.
Dental press j. orthod. (Impr.) ; 18(2): 8-16, Mar.-Apr. 2013. ilus
Article in English | LILACS | ID: lil-683174
11.
Rev. Clín. Ortod. Dent. Press ; 11(1): 40-48, fev.mar. - 2012. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-855867

ABSTRACT

Este relato de caso descreve o tratamento de um paciente do sexo feminino, com 10 anos e 6 meses de idade, que apresentava síndrome de Turner do tipo mosaico e queixa principal de protrusão dos incisivos superiores. Ela apresentava má oclusão dentária e esquelética de Classe II, sobressaliência de 9mm e sobremordida de 6mm. A erupção dos dentes permanentes estava adiantada, apresentava, ainda, apinhamento moderado na região anterior da mandíbula, diastemas anteriores na arcada superior e uma inclinação vestibular acentuada dos incisivos superiores. O plano de tratamento consistiu no controle de crescimento vertical e anteroposterior com ancoragem extrabucal, alinhamento e nivelamento das arcadas, retração dos incisivos superiores e o estabelecimento de uma oclusão estável. Uma vez que meninas portadoras de síndrome de Turner têm o crescimento atrasado ou reduzido, com ausência de surto de crescimento, e o crescimento é imprevisível, durante o tratamento ortodôntico uma terapia com hormônios foi iniciada e isso, provavelmente, ajudou na terapia de controle de crescimento, uma vez que houve uma redução de 4º do ângulo ANB e uma relação dentária de Classe I foi atingida em 4 meses. Isso demonstra que a terapia com hormônios em pacientes com síndrome de Turner é de grande valor quando empregada durante a infância e adolescência. O tratamento proveu um sorriso agradável para a paciente e uma oclusão bem estabelecida, com corretas sobressaliência e sobremordida, uma oclusão de Classe I e um alinhamento dentário satisfatório.


Subject(s)
Humans , Female , Child , Growth and Development , Hormone Replacement Therapy , Malocclusion, Angle Class II/therapy , Orthodontic Appliances , Patient Care Planning , Turner Syndrome
12.
Dental press j. orthod. (Impr.) ; 17(1): 52-61, Jan.-Feb. 2012. ilus
Article in English | LILACS | ID: lil-623173

ABSTRACT

OBJECTIVE: To investigate the ability of undergraduate students in diagnosing Angle Class II malocclusion and evaluate the clinical approach of these students toward a patient displaying this condition. METHODS: The sample consisted of 138 students attending the last semester of 10 dental schools in the State of Rio de Janeiro/Brazil assessed by questionnaires with closed questions. They were presented with photographs and dental casts of a patient in the mixed dentition, with Angle Class II malocclusion, increased overjet and overbite, deviated dental midlines and anterior diastemas in the upper arch. RESULTS: It was found that students easily identified increased overjet (92% of students), followed by the presence of diastemas (89%), midline deviation (84.7%) and increased overbite (77.3%). Conversely, approximately half the sample (n=70 or 51% of the students) were able to identify bilateral Angle Class II malocclusion. Nearly all agreed on the need for treatment and that it should be provided by a specialist (n=131 or 95%), but found it difficult to determine the ideal moment to start orthodontic treatment: 48.9% of the sample would begin treatment at the end of the mixed dentition, 41.7% would indicate treatment during deciduous dentition and 7.9% during permanent dentition. CONCLUSIONS: On completion of their undergraduate courses, students encounter difficulties in diagnosing Class II and even find it hard to articulate ideas about a basic treatment protocol to correct this malocclusion.

13.
Dental press j. orthod. (Impr.) ; 16(6): 33-35, nov.-dez. 2011. tab
Article in Portuguese | LILACS | ID: lil-614656

ABSTRACT

INTRODUÇÃO: o dimensionamento adequado da amostra estudada e a análise apropriada do erro do método são passos importantes na validação dos dados obtidos em determinado estudo científico, além das questões éticas e econômicas. OBJETIVO: esta investigação tem o objetivo de avaliar, quantitativamente, com que frequência os pesquisadores da ciência ortodôntica têm empregado o cálculo amostral e a análise do erro do método em pesquisas publicadas no Brasil e nos Estados Unidos. MÉTODOS: dois importantes periódicos, de acordo com a Capes (Coordenação de Aperfeiçoamento de Pessoal de Nível Superior), foram analisados, a Revista Dental Press de Ortodontia e Ortopedia Facial (Dental Press) e o American Journal of Orthodontics and Dentofacial Orthopedics (AJO-DO). Apenas artigos publicados entre os anos de 2005 e 2008 foram analisados. RESULTADOS: a maioria das pesquisas publicadas em ambas as revistas emprega alguma forma de análise do erro do método, quando essa metodologia pode ser aplicada. Porém, apenas um número muito pequeno dos artigos publicados nesses periódicos apresenta qualquer descrição de como foram dimensionadas as amostras estudadas. Essa proporção, já pequena (21,1 por cento) na revista editada nos Estados Unidos (AJO-DO), é significativamente menor (p=0,008) na revista editada no Brasil (Dental Press) (3,9 por cento). CONCLUSÃO: os pesquisadores e o corpo editorial, de ambas as revistas, deveriam dedicar uma maior atenção ao exame dos erros inerentes à ausência de tais análises na pesquisa científica, em especial aos erros inerentes a um dimensionamento inadequado das amostras.


INTRODUCTION: Reliable sample size and an appropriate analysis of error are important steps to validate the data obtained in a scientific study, in addition to the ethical and economic issues. OBJECTIVE: To evaluate, quantitatively, how often the researchers of orthodontic science have used the calculation of sample size and evaluated the method error in studies published in Brazil and in the United States of America. METHODS: Two major journals, according to CAPES (Brazilian Federal Agency for Support and Evaluation of Graduate Education), were analyzed through a hand search: Revista Dental Press de Ortodontia e Ortopedia Facial and the American Journal of Orthodontics and Dentofacial Orthopedics (AJO-DO). Only papers published between 2005 and 2008 were examined. RESULTS: Most of surveys published in both journals employed some method of error analysis, when this methodology can be applied. On the other hand, only a very small number of articles published in these journals have any description of how sample size was calculated. This proportion was 21.1 percent for the journal published in the United States (AJO-DO), and was significantly lower (p= 0.008) for the journal of orthodontics published in Brazil (3.9 percent). CONCLUSION: Researchers and the editorial board of both journals should drive greater concern for the examination of errors inherent in the absence of such analyses in scientific research, particularly the errors related to the use of an inadequate sample size.


Subject(s)
Biometry , Statistics as Topic , Orthodontics
14.
Ortodontia ; 44(3): 254-259, maio.-jun. 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-713804

ABSTRACT

Com o objetivo de avaliar os contatos oclusais de pacientes tratados ortodonticamente, foram selecionados 30 pacientes com intercuspidação oclusal estática satisfatória eboa finalização ortodôntica. Esses pacientes foram moldados imediatamente após a remoçãodos aparelhos superior e inferior e seus modelos montados em articuladores semiajustáveis nas posições de relação cêntrica e máxima intercuspidação. Avaliou-se a presença de deslizeentre estas duas posições nos sentidos anteroposterior, vertical e sagital; a presença de contatos prematuros na posição de relação cêntrica; o tipo de guia de desoclusão; a presençade prematuridades no lado de não trabalho. Dos 30 pacientes analisados, apenas três apresentaram as posições de relação cêntrica e máxima intercuspidação coincidentes. Os outrosmostraram diferenças quando avaliados nos sentidos anteroposterior, vertical e sagital, Foram identificados contatos prematuros em todos os pacientes, sendo que os segundos molares foram os responsáveis pela maior parte destes contatos prematuros. Quanto à análise dos guias de desoclusão, a maior parte desses pacientes apresentou guia anterior e apenas três pacientes apresentaram contato no lado de não trabalho. Torna-se evidente a necessidade de uma avaliação em longo prazo para determinar as mudanças que podem ocorrer no que diz respeito aos contatos oclusais, em pacientes tratados ortodonticamente, para se decidirquanto à necessidade de um ajuste oclusal.


With the aim of evaluating the occlusal contacts of patients that weresubmitted to orthodontic treatment, it was selected thirty patients with a good orthodontic treatment outcome. It was done the study casts immediately after the appliance removal and those casts were mounted in the semi-adjustable articulator in the centric relation andin the maximal intercuspation position. It was evaluated if there was any difference between those positions in the antero-posterior, vertical or lateral way; if there was any premature contact in the centric relation position; the type of desocclusion guidance and if there wasany premature contact in the non-working side. Of the thirty patients analyzed, only threedidn't show any difference between centric relation and maximal intercuspation. It wasidentified premature contacts in ali patients and in most of them the second molars causedit. Most patients presented an anterior guidance and only three patients had contacts inthe non-working side. It becomes clear the need of a long term evaluation to determine thechanges that may occur with those occlusal contacts so it can be decided if there is anyneed of an occlusal adjustment.


Subject(s)
Humans , Adolescent , Centric Relation , Dental Occlusion , Functional Laterality
15.
Dental press j. orthod. (Impr.) ; 16(1): 48-56, jan.-fev. 2011. tab
Article in Portuguese | LILACS | ID: lil-580314

ABSTRACT

OBJETIVO: o presente estudo avaliou clinicamente as condições periodontais de um grupo teste e um grupo controle utilizando-se os seguintes três sistemas de indexação periodontal: índice de biofilme, índice de sangramento e profundidade de sondagem. MÉTODOS: o grupo teste foi composto por 20 indivíduos com média etária de 13,5 anos, submetido ao tratamento ortodôntico fixo, que recebeu duas formas de ligaduras: a elastomérica e a de aço inoxidável. Os resultados foram comparados entre si e com um grupo controle, sem tratamento ortodôntico, composto de 15 indivíduos com média etária de 15,3 anos. As mensurações foram realizadas previamente ao tratamento ortodôntico (T1) e seis meses após a colocação do aparelho ortodôntico fixo (T2); e, no grupo controle, após seis meses da mensuração inicial (T2). Ambos os grupos foram orientados quanto à higiene bucal, segundo a técnica de Bass, antes do início do tratamento. RESULTADOS E CONCLUSÕES: os resultados das análises das faces dentárias demonstraram um aumento estatisticamente significativo nos índices de biofilme (P=0,000), sangramento gengival (P=0,000) e profundidade de sondagem (P=0,000), quando T1 e T2 e os grupos foram comparados; entretanto, não foram encontradas diferenças estatisticamente significativas entre as ligaduras elastoméricas e de aço inoxidável na avaliação desses índices periodontais.


OBJECTIVE: This study aimed to conduct a clinical evaluation of the periodontal conditions of a test group and a control group using three periodontal indexing systems, namely: dental biofilm index (DBI), bleeding index (BI) and pocket probing depth (PPD). METHODS: The test group consisted of 20 subjects with a mean age of 13.5 years undergoing fixed orthodontic treatment involving the use of two types of ligature: elastomeric ligature (EL) and stainless steel ligature (SSL). The results were compared with a control group without prior orthodontic treatment, comprising 15 subjects with a mean age of 15.3 years. The measurements were performed prior to orthodontic treatment (T1) and six months after placement of a fixed orthodontic appliance (T2); and in the control group, six months after the initial measurement (T2). Both groups were instructed about oral hygiene, according to the Bass technique, before treatment. RESULTS AND CONCLUSIONS: Dental surfaces showed a statistically significant increase in levels of biofilm (P=0.000), gingival bleeding (P=0.000) and probing depth (P=0.000). When the T1 and T2 groups were compared, however, no statistically significant differences were found between EL and SSL in terms of these periodontal indexes.


Subject(s)
Humans , Stainless Steel , Orthodontic Appliances/adverse effects , Orthodontic Appliances/statistics & numerical data , Orthodontic Appliances , Periodontal Diseases , Dental Plaque/etiology , Dental Plaque/therapy , Orthodontics , Periodontics
16.
Dental press j. orthod. (Impr.) ; 15(6): 61-70, nov.-dez. 2010.
Article in Portuguese | LILACS | ID: lil-578682

ABSTRACT

OBJETIVOS: o objetivo desse estudo foi buscar na literatura informações consistentes sobre a qualidade de vida relacionada à saúde bucal, permitindo aos clínicos acessar e compreender sua influência no processo de busca e tratamento de seus pacientes. MÉTODOS: foram pesquisadas as bases de dados eletrônicas MEDLINE, LILACS, BBO e Cochrane Controlled Trials, entre 1980 e 2010. Foram encontrados 158 estudos que discutiam a qualidade de vida relacionada à saúde bucal. RESULTADOS: foram selecionados 30 estudos, sendo dois prospectivos longitudinais, duas revisões sistemáticas, cinco casos-controle, doze estudos epidemiológicos, cinco estudos transversais e três revisões de literatura, além da declaração da Organização Mundial da Saúde. A seleção baseou-se no objetivo de descrever os indicadores de qualidade de vida, e na metodologia utilizada nos estudos. CONCLUSÕES: o uso de indicadores de qualidade de vida na pesquisa odontológica e na clínica ortodôntica é de grande importância e auxílio no diagnóstico e planejamento; todavia, esses não substituem os índices normativos, devendo ser usados em caráter complementar.


OBJECTIVES: The purpose of this study was to survey reliable information about quality of life as it relates to oral health in the literature, allowing clinicians to access and understand its influence on the process of finding and treating their patients. METHODS: The MEDLINE, LILACS, BBO and Cochrane Controlled Trials electronic databases were researched between 1980 and 2010 and 158 studies were found that discuss quality of life related to oral health. RESULTS: Thirty studies were selected: two prospective longitudinal studies, two systematic reviews, five case-control studies, twelve epidemiological studies, five cross-sectional studies and three reviews of literature, in addition to the Statement of the World Health Organization (WHO). The selection was based on the goal of describing the indicators of quality of life and the methodology used in the studies. CONCLUSIONS: The use of quality of life indicators in dental research and clinical orthodontics are extremely important and helpful in diagnosis and planning but do not replace standard indexes and should be used in a strictly complementary manne.


Subject(s)
Malocclusion , Orthodontics , Quality of Life
17.
Rev. Clín. Ortod. Dent. Press ; 9(3): 88-94, jun.-jul. 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-562642

ABSTRACT

A erupção ectópica e a impacção de caninos superiores são achados relativamente comuns em Ortodontia e Odontopediatria. O diagnóstico e planejamento do tratamento normalmente envolve exames radiográficos complementares no intuito de avaliar o posicionamento dos caninos e o possível grau de reabsorção nos elementos adjacentes. Modelos virtuais tridimencionais gerados a partir de tomografia computadorizada podem ser úteis, já que geram informações precisas e intuitivas em relação à morfologia dentária e sua localização espacial. O objetivo deste relato de caso foi descrever como a utilização dessa tecnologia auxiliou no diagnóstico de reabsorção radicular decorrente da erupção ectópica de caninos superiores em gêmeos monozigóticos.


Subject(s)
Humans , Male , Child , Tooth, Impacted/diagnosis , Diagnostic Imaging , Imaging, Three-Dimensional , Radiography, Panoramic , Root Resorption/diagnosis , Tomography, Spiral Computed , Cuspid , Twins, Monozygotic
18.
Dental press j. orthod. (Impr.) ; 15(3): 121-124, jun. 2010. ilus
Article in English, Portuguese | LILACS | ID: lil-550670

ABSTRACT

Frequentemente, estudos que utilizam populações são questionados quanto à homogeneidade de suas amostras em relação à raça e etnia. Esses questionamentos procedem, pois a heterogeneidade amostral pode aumentar a variabilidade dos resultados e mascará-los. Esses dois conceitos (raça e etnia) são confundidos inúmeras vezes, mas existem diferenças sutis entre ambos: raça engloba características fenotípicas, como a cor da pele, e etnia também compreende fatores culturais, como a nacionalidade, afiliação tribal, religião, língua e as tradições de um determinado grupo. A despeito da ampla utilização do termo "raça", cresce entre os geneticistas a definição de que raça é um conceito social, muito mais que científico.


Studies involving populations are often questioned as to the homogeneity of their samples relative to race and ethnicity. Such questioning is justified because sample heterogeneity can increase the variability of and even mask results. These two concepts (race and ethnicity) are often confused despite their subtle differences. Race includes phenotypic characteristics such as skin color whereas ethnicity also encompasses cultural factors such as nationality, tribal affiliation, religion, language and traditions of a particular group. Despite the widespread use of the term "race", geneticists are increasingly convinced that race is much more a social than a scientific construct.

19.
Dental press j. orthod. (Impr.) ; 15(1): 101-106, jan.-fev. 2010. ilus
Article in English, Portuguese | LILACS | ID: lil-552067

ABSTRACT

A seleção de métodos apropriados para a análise estatística pode parecer complexa, principalmente para estudantes de pós-graduação e pesquisadores no início da carreira científica. Por outro lado, a apresentação em PowerPoint é uma ferramenta comum para estudantes e pesquisadores. Assim, um tutorial de Bioestatística desenvolvido em uma apresentação em PowerPoint poderia estreitar a distância entre ortodontistas e a Bioestatística. Esse guia proporciona informações úteis e objetivas a respeito de vários métodos estatísticos empregando exemplos relacionados à Odontologia e, mais especificamente, à Ortodontia. Esse tutorial deve ser empregado, principalmente, para o usuário obter algumas respostas a questões comuns relacionadas ao teste mais apropriado para executar comparações entre grupos, examinar correlações e regressões ou analisar o erro do método. Também pode ser obtido auxílio para checar a distribuição dos dados (normal ou anormal) e a escolha do gráfico mais adequado para a apresentação dos resultados. Esse guia* pode ainda ser de bastante utilidade para revisores de periódicos examinarem, de forma rápida, a adequabilidade do método estatístico apresentado em um artigo submetido à publicação.


Selecting appropriate methods for statistical analysis may be difficult, especially for the students and others in the early phases of the research career. On the other hand, PowerPoint presentation is a very common tool to researchers and dental students, so a statistical guide based on PowerPoint could narrow the gap between orthodontist and the Biostatistics. This guide provides objective and useful information about several statistical methods using examples related to the dental field. A Power-Point presentation is employed to assist the user to find answers to common questions regarding Biostatistics, such as the most appropriate statistical test to compare groups, to make correlations and regressions or to look for systematic error for a specific method. Assistance to check normality distribution and to choose the most suitable graphics is also presented. This guide (downloadable in www.dentalpress.com.br) could be even used by reviewers in a quick assessment to check the appropriated statistical methodology into a specific study.


Subject(s)
Biostatistics , Data Display , Health Statistics , Interactive Tutorial , Data Interpretation, Statistical
20.
Rev. dent. press ortodon. ortopedi. facial ; 14(6): 144-157, nov.-dez. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-533073

ABSTRACT

A grande variedade de fios ortodônticos presente no mercado pode gerar dúvidas quanto à melhor escolha para situações clínicas. Assim, o conhecimento das propriedades mecânicas dos mesmos facilita a escolha para aplicação do movimento ortodôntico na dependência da fase em que o tratamento se encontra. A evolução da tecnologia de manufatura dos fios e a elaboração de novas técnicas ortodônticas geraram a busca por uma melhor qualidade das ligas, a fim de torná-los biologicamente mais efetivos no que diz respeito aos dentes e tecidos de suporte. O presente artigo resume as principais características dos fios utilizados em Ortodontia, em relação ao histórico, propriedades mecânicas e aplicação clínica, de acordo com fases específicas de tratamento.


The huge variety of orthodontic wires brands available in market might generate confusion as regard to the best choice for clinical application. Therefore mechanical properties knowledge about wires would help the professional to apply the best orthodontic technique depending on the treatment phase. The wires manufacturing evolution and the new orthodontic techniques proposed guided the market into the search for better quality alloys, in order to make them biologically more effective to teeth and support tissues. This paper aims to summarize some main characteristics of orthodontic wires related to their history, mechanical properties and clinical application as regard to individual phase of treatment.


Subject(s)
Orthodontic Wires/history , Orthodontic Wires , Orthodontics
SELECTION OF CITATIONS
SEARCH DETAIL