Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Acta Academiae Medicinae Sinicae ; (6): 300-304, 2021.
Article in Chinese | WPRIM | ID: wpr-878736

ABSTRACT

Intracranial intradural chondroma is a rare disorder,the imaging findings of which have been rarely reported.The current study reported a case of intracranial extra-cerebral chondroma and described the detailed CT and magnetic resonance imaging findings,which would provide valuable imaging evidence for the diagnosis of intracranial extra-cerebral chondroma.


Subject(s)
Humans , Brain Neoplasms/diagnostic imaging , Chondroma/diagnostic imaging , Magnetic Resonance Imaging , Tomography, X-Ray Computed
2.
Acta Academiae Medicinae Sinicae ; (6): 57-62, 2021.
Article in Chinese | WPRIM | ID: wpr-878699

ABSTRACT

Objective To investigate the intra-and inter-observer reproducibility of iodine concentrations of abdominal parenchymal organs based on spectral CT.Methods The water-free iodine images of the venous phase were retrospectively obtained from 50 patients with abdominal dynamic spectral CT scans.The iodine concentrations were measured in the left,right and caudate lobes of liver,spleen,pancreas and bilateral kidneys.Intraclass correlation coefficient(ICC)and Bland-Altman plot were employed to analyze the intra-and inter-observer reproducibility.Results The intra-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.938(0.894,0.965),0.932(0.884,0.961),0.939(0.895,0.965),0.947(0.909,0.970),0.912(0.851,0.949),0.946(0.906,0.969)and 0.907(0.842,0.946),which indicated good intra-observer reproducibility.The inter-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.947(0.909,0.970),0.927(0.875,0.958),0.943(0.902,0.968),0.956(0.924,0.975),0.934(0.887,0.962),0.927(0.875,0.958)and 0.892(0.818,0.937),which indicated good inter-observer reproducibility.Bland-Altman plots presented that more than 95% points of the intra-observer differences located within 95% CI of limits of agreement for the caudate lobe of liver,spleen,pancreas and bilateral kidneys,which was same as inter-observer differences of the caudate lobe of liver,spleen and right kidney.Conclusion The iodine concentration measurement based on the spectral CT presented good intra-and inter-observer reproducibility for the caudate lobe of liver and spleen.


Subject(s)
Humans , Iodine , Observer Variation , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed
3.
Acta Academiae Medicinae Sinicae ; (6): 776-780, 2020.
Article in Chinese | WPRIM | ID: wpr-878677

ABSTRACT

Objective To identify the optimal mono-energetic enhanced spectral CT for renal cortex in cortical phase based on the iodine concentration. Methods Fifty patients with normal renal function received the abdominal enhanced spectral CT examination.The iodine concentration and CT values of the multiple mono-energetic spectral images were measured on renal cortex in cortical phase,and the correlation between the iodine concentration and the CT values and the coefficient of variation(CV)were analyzed. Results The correlation analysis demonstrated that the correlation coefficient was 0.994,0.994,0.993,0.987,0.976,0.960,and 0.938 between mono-energetic spectral CT images(40-100 keV with interval 10 keV,respectively)and iodine concentration(all


Subject(s)
Humans , Contrast Media , Iodine , Kidney Cortex/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL