Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
ImplantNews ; 04(06): 610-613, Nov./Dez.2007.
Article in Portuguese | LILACS, BBO | ID: biblio-850891

ABSTRACT

Realizou-se revisão da literatura sobre osseopercepção em Implantologia. Foi verifi cado que os trabalhos concordam sobre a existência de um mecanismo de osseopercepção provenientes de mecanorreceptores com localização ainda não bem defi nida.


Subject(s)
Osseointegration , Perception , Sensation Disorders
2.
Rev. ABO nac ; 14(6): 368-372, dez. 2006-jan. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-544425

ABSTRACT

Dentre os vários fatores que podem acarretar fracassos em próteses parciais fixas na região anterior, a fratura de dentes suporte pode ser considerada uma das mais graves, pois, na maioria das vezes, impossibilita a reconfecção do trabalho. Aspectos oclusais funcionais estáticos e dinâmicos estão inseridos nesse contexto como um dos principais fatores etiológicos que aumentam a possibilidade de fraturas quando associados a fatores secundários como a desvitalidade do dente suporte, a utilização incorreta de pinos e núcleos protéticos e a presença de parafunção, dentre outros. Desse modo, este trabalho tem por objetivo avaliar como a presença desses fatores etiológicos, tanto principais como secundários , poderão interferir no prognóstico final dessas próteses, bem como propor métodos de observação para que seja possível diminuir a incidência desse tipo de fracasso.


Among the various aspects that can cause failures in fixed partial dentures in the anterior regions, the fracture of the abutment teeth, is considered as the serious one, because, in the majority cases, become impossible the replacement of this prosthesis. Occlusal functional aspects static and dynamics are inserts in this context as one of the principal etiologic factors, that, when associate to secondary factors, with abutment teeth nonvital, incorrect use of prosthetics posts and cores, parafunction, and others, increase the possibility of fractures. Therefore, the aim of this article was to value with the presence of this etiologic factors, principals as much secondary, might interfere in final prognostic of this prosthesis, like this, propose observation methods in order to decrease the incidence of these failures.


Subject(s)
Humans , Adult , Dental Occlusion , Denture, Partial, Fixed , Tooth Fractures/etiology
3.
Rev. odontol. UNESP ; 34(1): 25-30, jan.-mar. 2005. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-519049

ABSTRACT

O objetivo deste estudo foi avaliar a resistência da união metal/cerâmica entreduas ligas à base de Ni-Cr (com ou sem Be) e três sistemas cerâmicos por meio de um testede cisalhamento. Diante dos resultados (kgf) analisados estatisticamente pelo teste ANOVA e,posteriormente, pelo Tukey a 5%, foi possível concluir que: o sistema cerâmico Williams associadoà liga Durabond apresentou os maiores valores de resistência ao cisalhamento (59,78), diferindoestatisticamente dos demais sistemas avaliados (P < 0,05); não houve diferença estatisticamentesignificante entre os grupos confeccionados pela associação dos sistemas metal/cerâmica Durabond/Vita VMK (53,39), Litecast/Vita VMK (53,21) e Litecast/Willians (46,58) (P > 0,05); o sistemacerâmico Noritake apresentou os menores valores de resistência ao cisalhamento independente daliga utilizada (Durabond/Noritake - 32,36; Litecast/Noritake - 30,09) (P < 0,05).


The aim of this study was to evaluate the bond strength metal/ceramic betweentwo Ni-Cr ûbased alloys (with or without beryllium) and three ceramics systems using a sheartest. In front of results (kgf) analyzed statistically by ANOVA test and, subsequently by TukeyÆstest 5%, was possible concluded that: for Williams ceramic system associate to Durabond alloyshowed the greatest values of shear bond strength (59.78), differing statistically of the otherssystems evaluated (P < 0.05); there isnÆt difference statistically significant among the groupsmanufacturing by association to metal/ceramic systems Durabond/Vita VMK (53.39), Litecast/VitaVMK (53.21) e Litecast/Willians (46.58) (P > 0.05); the Noritake ceramic system showed the leastvalues of shear bond strength independent of alloy used (Durabond/Noritake - 32.36; Litecast/Noritake - 30.09) (P < 0.05).


Subject(s)
Metal Ceramic Alloys , Shear Strength
4.
Rev. bras. odontol ; 62(1/2): 52-54, 2005. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-427962

ABSTRACT

O objetivo deste artigo é descrever situações clínicas que podem ocorrer em prótese parcial fixa quando são utilizados dentes suportes intermediários. Dependendo da localização destes, problemas como dificuldade de higienização, fratura da linha de cimentação, intrusão ou ação deles como fulcro podem ocorrer. Uma alternativa para minimizar os problemas mecânicos é a utilização de conectores semi-rígidos que possibilitem uma movimentação individual das unidades que compõe a prótese frente aos esforços mastigatórios


Subject(s)
Dental Abutments , Denture, Partial, Fixed
5.
Rev. odontol. UNESP ; 33(2): 95-99, abr.-jun. 2004. ilus
Article in Portuguese | LILACS, BBO | ID: lil-510859

ABSTRACT

Este estudo teve por objetivo avaliar a resistência de união metalocerâmica entre uma liga seminobre de paládio/prata, ante diferentes tempos de oxidação prévia à aplicação de trêssistemas cerâmicos. Foi utilizado um teste de cisalhamento e, diante dos resultados analisados estatisticamente pelo teste ANOVA e, posteriormente, pelo TUKEY a 5%, foi possível concluir que: para a cerâmica Duceram, não houve diferenças estatisticamente significantes entre os tempos deoxidação prévia da liga; para a cerâmica da Williams, o grupo em que não houve oxidação prévia apresentou os menores valores (58,04), e a oxidação por 5 minutos proporcionou a maior média devalores entre os grupos estudados (88,25); para a cerâmica da Noritake, não houve diferenças de resultados em relação aos tratamentos, porém, a mesma apresentou as menores médias de todos os grupos.


Subject(s)
Dental Alloys , Metal Ceramic Alloys , Shear Strength
6.
JBC j. bras. clin. odontol. integr ; 7(37): 14-19, jan.-fev. 2003. ilus
Article in Portuguese | LILACS, BBO | ID: lil-391752

ABSTRACT

As restaurações em resina composta são o grande advento da época, sendo várias as suas técnicas de aplicação. Os corantes à base de resina podem ser usados para dar características mais naturais ao dente restaurado. Neste artigo, apresentamos sua composição e as principais formas de utilização, dependendo de cada caso, exemplificando através de casos clínicos a simplicidade da aplicação da técnica e os resultados satisfatórios obtidos


Subject(s)
Humans , Female , Adolescent , Color , Coloring Agents , Composite Resins , Esthetics, Dental , Dental Restoration, Permanent/methods
SELECTION OF CITATIONS
SEARCH DETAIL