Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Rev. bras. ortop ; 37(5): 201-203, maio 2002. ilus
Article in Portuguese | LILACS | ID: lil-334668

ABSTRACT

The authors present the results obtained in surgical treatment of spontaneous tendon rupture in patient with chronic renal failure. Revision of the literature shows that the surgical treatment of such a kind of tendon rupture is required in order to obtain a good final result


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Renal Insufficiency, Chronic/complications , Palpation , Tendon Injuries/surgery , Rupture, Spontaneous , Tendon Injuries/diagnosis
2.
Rev. bras. ortop ; 35(10): 419-421, out. 2000. ilus
Article in Portuguese | LILACS | ID: lil-339725

ABSTRACT

The authors present a case of a 27 year-old female patient with Von Willebrand's disease and submitted to surgical arthroscopy of the right knee. She developed a neurological condition of intense migraine due to cerebral hemorrhage after subdural anesthesia. The authors discuss the probable etiology of the illness, the evolution of the case, and the possible association with the subdural anesthesia.


Subject(s)
Humans , Female , Adult , Anesthesia , Arthroscopy , von Willebrand Diseases
3.
Rev. bras. ortop ; 35(1/2): 23-28, jan.-fev. 2000. ilus, graf
Article in Portuguese | LILACS | ID: lil-335745

ABSTRACT

Os autores estudaram, em laboratório, o comportamento mecânico do sistema clássico de fixaçäo externa de Ilizarov para o tratamento de uma fratura diafisária de ossos longos, em montagens ortogonais, de máxima estabilidade mecânica, e anatômicas, pertinentes aos corredores de segurança anatômicos da tíbia. Utilizaram um corpo de prova de polietileno em configuraçäo tubular e submeteram as montagens a cargas axiais centrais e excêntricas de 0 a 100kgf. Observaram que, do ponto de vista mecânico, o fixador externo de Ilizarov funciona como um sistema de associaçäo de molas em paralelo, possuindo grande resistência axial elástica capaz de retornar toda deformaçäo sofrida pelo sistema à exata posiçäo inicial após o retorno da força axial aplicada a zero


Subject(s)
Humans , Bone Lengthening , Diaphyses/injuries , External Fixators , Ilizarov Technique , Biomechanical Phenomena
4.
Rev. bras. ortop ; 34(3): 193-6, mar. 1999. ilus, tab
Article in Portuguese | LILACS | ID: lil-275158

ABSTRACT

Os autores apresentam os resultados obtidos no tratamento profilático das contraturas secundárias ao alongamento da tíbia em 12 pacientes, oito homens e quatro mulheres, utilizando técnicas associadas de tenotomia percutânea trifocal do tendäo do gastrocnêmico e estabilizaçäo do calcâneo. Correlacionam com a literatura, relatando resultados superiores àqueles obtidos pelos métodos profiláticos tradicionais.


Subject(s)
Humans , Animals , Male , Female , Child , Adolescent , Adult , Middle Aged , Bone Lengthening , Tibia/surgery , Bone Lengthening/adverse effects , Ilizarov Technique
5.
Rev. bras. ortop ; 34(2): 134-138, fev. 1999. ilus, graf
Article in Portuguese | LILACS | ID: lil-360898

ABSTRACT

Foi estudado em laborat¢rio, comparativamente, o comportamento mecânico de cinco montagens do fixador externo AO/ ASIF: AO simples, AO dupla barra, AO transfixante uniplanar, AO transfixante biplanar e AO biplanar half pin (delta). As montagens foram instaladas em um corpo de prova de polietileno que simula um osso diafisário longo e submetidas às forças de compressão axial central e excêntrica. Foram avaliados os deslocamentos radiais de seus segmentos, a distância máxima observada entre estes nos planos perpendiculares ao axial e os movimentos em flexão dos segmentos do corpo de prova. Os resultados obtidos permitem afirmar que os fixadores externos que utilizaram apenas pinos de fixação do tipo half pin se apresentaram menos estáveis que os que usaram pinos transfixantes. O melhor resultado foi observado na montagem transfixante biplanar, que apresentou grande estabilidade em todos os planos, seguida pela transfixante uniplanar.


Subject(s)
External Fixators , Biomechanical Phenomena
6.
Rev. bras. ortop ; 33(7): 552-6, jul. 1998. ilus, graf
Article in Portuguese | LILACS | ID: lil-224372

ABSTRACT

Foi estudado em laboratório, comparativamente, o comportamento mecânico dos sistemas clássicos de fixaçao externa de plataforma Hoffmann e Hoffmann-Vidal, utilizando-se configuraçoes espaciais freqüentemente aplicadas. As montagens foram instaladas em um corpo de prova de polietileno que simula um osso diafisário longo e submetidos às forças de compressao axial central e excêntrica. Foram avaliados os deslocamentos radiais de seus segmentos, a distância máxima observada entre esses segmentos nos planos perpendiculares ao axial e os movimentos em flexao dos segmentos do corpo de prova. Os resultados obtidos permitem afirmar que os fixadores externos de plataformas que utilizaram pinos de fixaçao do tipo hal pin (pinos de Schanz) apresentaram-se muito menos estáveis que os que usaram pinos transfixantes (pinos de Hoffmann).


Subject(s)
Bone Diseases , External Fixators/statistics & numerical data , Diaphyses , Bone Nails , Polyethylenes
SELECTION OF CITATIONS
SEARCH DETAIL