Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. Assoc. Med. Bras. (1992) ; 68(3): 356-361, Mar. 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1376117

ABSTRACT

SUMMARY OBJECTIVE: The aim of this study was to evaluate the relationship between the range of motion and lower-limb hemodynamic indices in the tibiotarsal joint of individuals with diabetic neuropathy. METHODS: Twenty volunteers of both sexes, with a mean age of 61.45±7.05 years, were diagnosed with type 2 diabetes mellitus and diabetic peripheral neuropathy. Arterial blood flow was assessed using Doppler ultrasound, and the variables such as average velocity, pulsatility index, and resistivity index were also evaluated. A range of dorsiflexion and plantar flexion joint movements were assessed using digital goniometry before and after exercise. Data distribution was assessed using the Shapiro-Wilk test, followed by Pearson's correlation for normal data and Spearman's correlation for non-normal data, in order to verify the association between variables. RESULTS: A moderate correlation was found between dorsiflexion and pulse rate on two occasions before (rs=0.497) and after initial evaluation (rs=0.511). A low correlation was found between plantar flexion and mean velocity (rs=-0.357), pulsatility index (rs=0.439), and resistivity index (rs=0.328); dorsiflexion and mean velocity (rs=0.374), pulse rate (rs=0.332), and resistance index (rs=0.327) before evaluation, and peak (rs=0.346) was observed after the evaluation of blood circulation. CONCLUSION: There is a correlation between the range of motion of the tibiotarsal joint and the blood circulation of diabetics, ranging from moderate to poor for the different variables evaluated.

2.
ABC., imagem cardiovasc ; 35(4): eabc349, 2022. ilus
Article in Portuguese | LILACS | ID: biblio-1434566

ABSTRACT

A endomiocardiofibrose é uma doença negligenciada e predominante em países subdesenvolvidos. Apesar de sua frequência, ainda é considerada rara. Assim, a doença é marcada pelos seguintes achados: distorção arquitetural, alterações no enchimento ventricular e alterações da mobilidade segmentar. Ela afetando não só a dinâmica diastólica e sistólica, como também as funções das válvulas cardíacas. Em uma condição mais avançada da doença, pode haver formação de trombos apicais. Neste relato de caso, revisitamos a endomiocardiofibrose, apresentando um caso desafiador de paciente do sexo feminino de 52 anos, com clínica de insuficiência cardíaca classe funcional IV da New York Heart Association. A eletrocardiografia de repouso revelou ritmo sinusal com sobrecarga do ventrículo esquerdo com vetores de alta voltagem, infradesnivelamento retificado do segmento ST e onda T negativa em região anterolateral, podendo ser compatível com padrão de strain. Já na avaliação de imagens ecocardiográficas, revelou dilatação acentuada do átrio esquerdo, com ventrículos sem dilatações e imagem de ocupação apical hiperrefringente no interior do ventrículo esquerdo, sugerindo grande trombo séssil sobreposto à capa fibrosa endocárdica. Embora a conduta cirúrgica seja a mais apoiada em literatura em tais situações, a paciente aqui apresentada recebeu tratamento com anticoagulação oral por 1 mês e 24 dias. Ela evoluiu clinicamente bem, com melhora da classe funcional da New York Heart Association e, em ecocardiografia realizada 2 meses após o início da anticoagulação oral, houve demonstração da regressão da imagem de trombo apical, apoiada com a técnica de contraste endocavitário.(AU)


Endomyocardial fibrosis (EMF) is a neglected but prevalent disease in underdeveloped countries. Despite its frequency, it is still considered a rare disease. It is marked by the following findings: architectural distortion, ventricular filling changes, and segmental mobility changes affecting not only diastolic and systolic dynamics but also heart valve function. Apical thrombi can be formed in more advanced disease. In this case report, we revisit EMF and present the challenging case of a 52-year-old woman with New York Heart Association (NYHA) functional classification (FC) IV heart failure. Resting electrocardiography revealed sinus rhythm with left ventricular (LV) overload, high voltage vectors, rectified ST-segment depression, and a negative T-wave in the anterolateral region compatible with the strain pattern. The evaluation of echocardiographic images showed marked left atrial dilation, no ventricular dilatation, and hyper-refringent apical occupation within the LV suggestive of a large sessile thrombus superimposed on the endocardial fibrous layer. Although surgery is the most supported approach in the literature in such situations, this patient was treated with oral anticoagulants (OAC) for 1 month and 24 days. The patient progressed well with an improved NYHA FC. Endocavitary contrast echocardiography performed 2 months after OAC initiation showed regression of the apical thrombus image. (AU)


Subject(s)
Humans , Female , Middle Aged , Thrombosis/diagnostic imaging , Endomyocardial Fibrosis/complications , Endomyocardial Fibrosis/drug therapy , Echocardiography/methods , Magnetic Resonance Spectroscopy/methods , Heart Ventricles/physiopathology , Anticoagulants/administration & dosage , Anticoagulants/therapeutic use
3.
ABC., imagem cardiovasc ; 34(4): eabc258, 2021. tab, ilus
Article in Portuguese | LILACS | ID: biblio-1361250

ABSTRACT

Introdução: A ecocardiografia é uma ferramenta diagnóstica de crescente utilização na prática clínica, aplicada a diversos cenários médicos. Os cuidados e os processos de manutenção preventiva ou corretiva dos equipamentos são ainda pouco padronizados. O objetivo do presente estudo foi descrever o processo de manutenção atualmente aplicado a equipamentos ecocardiográficos em um laboratório. Descrever o processo inclui a caracterização de danos e aplicações de manutenção preventiva ou corretiva. Métodos: Estudo observacional descritivo e exploratório realizado em centro único. As informações de dados do processo de manutenção de equipamentos ecocardiográficos foram obtidas de arquivos eletrônicos do sistema de gestão de equipamentos de um laboratório de médio porte de um hospital público de nível terciário com características de ensino, no período de 2003 a 2018. Resultados: Foram identificados dez tipos de avarias mais comuns, como dano a programas (23,8%), peças (23,1%) e relacionadas à queda de energia e de acessórios (13,8%). Após a implementação do processo de manutenção preventiva, houve significativa redução dos custos de manutenções (US$ 44.472,10 versus US$ 25.807,59; p= 0,029). Mesmo após a manutenção preventiva, os custos de manutenção corretiva em equipamentos aplicados à ecocardiografia transesofágica (US$ 7.789,17) foram maiores que aqueles a equipamentos aplicados a outras modalidades (US$ 3.184,37 em ecocardiografia transtorácica e US$1.813,00 em estresse). Conclusão: O processo de manutenção de equipamentos ecocardiográficos foi descrito. Danos a equipamentos ecocardiográficos estão relacionados a altos custos, principalmente naqueles aplicados a modalidades especiais, como ecocardiografia transesofágica. As manutenções preventivas reduziram significativamente os custos de manutenção. (AU)


Introduction: Echocardiography is a diagnostic tool that is increasingly used in clinical practice in different medical scenarios; however, the preventive (PM) or corrective maintenance (CM) care and processes for this equipment are still poorly standardized. To describe the maintenance process currently implemented for echocardiographic equipment (ECHO) in a medium-sized laboratory in a tertiary-level public teaching hospital. The description of the process includes damage characterization and MP and MC implementation. Methods: This was a descriptive and exploratory single-center observational study. Data on the maintenance process of echocardiographic equipment were obtained from electronic files from the hospital's equipment management system between 2003 and 2018. Results: Together with the description of the equipment maintenance process, the ten most common types of malfunctions were identified, including software (23.8%), parts (23.1%), and power outage and accessory damage (13.8%). The implementation of the PM process significantly decreased the maintenance costs (USD 44,472.10 vs USD 25,807.59, p = 0.029). Even after the MP, the CM costs related to transesophageal echocardiography equipment (TEE) (USD 7,789.17) were higher than those with other equipment modalities (USD 3,184.37 for transthoracic echocardiography equipment (TTE) and USD 1,813.00 for stress testing). Conclusion: The maintenance process for ECHO equipment was described. ECHO equipment damage has high costs, especially in special modalities such as TEE. PM significantly reduced maintenance costs. (AU)


Subject(s)
Humans , Echocardiography/economics , Equipment Maintenance/methods , Cost-Benefit Analysis/statistics & numerical data , Health Care Economics and Organizations , Equipment and Supplies/economics , Time Factors , Echocardiography, Transesophageal/statistics & numerical data , Ambulatory Care Facilities/organization & administration , Hospitals, Teaching/organization & administration
SELECTION OF CITATIONS
SEARCH DETAIL