Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Arq. bras. cardiol ; 118(4): 756-765, Apr. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1374346

ABSTRACT

Resumo Fundamento Demonstrou-se recentemente que a aplicação de ultrassom de alta energia com microbolhas, técnica conhecida como sonotrombólise, causa a dissolução de trombos intravasculares e aumenta a taxa de recanalização angiográfica no infarto agudo do miocárdio com supradesnivelamento do segmento ST (IAM-CSST). Objetivo Avaliar o efeito da sonotrombólise nos índices de motilidade e perfusão miocárdicas em pacientes com IAM-CSST, utilizando a ecocardiografia com perfusão miocárdica em tempo real (EPMTR). Método Uma centena de pacientes com IAM-CSST foram randomizados em dois grupos: Terapia (50 pacientes tratados com sonotrombólise e angioplastia coronária primária) e Controle (50 pacientes tratados com angioplastia coronária primária). Os pacientes realizaram EPMTR para analisar a fração de ejeção do ventrículo esquerdo (FEVE), o índice de escore de motilidade segmentar (IEMS) e o número de segmentos com defeito de perfusão miocárdica, 72 horas após o IAM-CSST e com 6 meses de acompanhamento. Foi considerado significativo p < 0,05. Resultados Pacientes tratados com sonotrombólise apresentaram FEVE mais alta que o grupo Controle em 72 horas (50 ± 10% vs. 44 ± 10%; p = 0,006), e essa melhora foi mantida em seis meses (53 ± 10% vs. 48 ± 12%; p = 0,008). O IEMS foi similar nos grupos Terapia e Controle em 72 horas (1,62 ± 0,39 vs. 1,75 ± 0,40; p = 0,09), mas tornou-se menor no grupo Terapia em 6 meses (1,46 ± 0,36 vs. 1,64 ± 0,44; p = 0,02). O número de segmentos com defeito de perfusão não foi diferente entre os grupos em 72 horas (5,92 ± 3,47 vs. 6,94 ± 3,39; p = 0,15), mas ficou menor no grupo Terapia em 6 meses (4,64 ± 3,31 vs. 6,57 ± 4,29; p = 0,01). Conclusão A sonotrombólise em pacientes com IAM-CSST resulta na melhora dos índices de motilidade e perfusão ventricular ao longo do tempo.


Abstract Background It has recently been demonstrated that the application of high-energy ultrasound and microbubbles, in a technique known as sonothrombolysis, dissolves intravascular thrombi and increases the angiographic recanalization rate in patients with ST-segment-elevation myocardial infarction (STEMI). Objective To evaluate the effects of sonothrombolysis on left ventricular wall motion and myocardial perfusion in patients with STEMI, using real-time myocardial perfusion echocardiography (RTMPE). Methods One hundred patients with STEMI were randomized into the following 2 groups: therapy (50 patients treated with sonothrombolysis and primary coronary angioplasty) and control (50 patients treated with primary coronary angioplasty). The patients underwent RTMPE for analysis of left ventricular ejection fraction (LVEF), wall motion score index (WMSI), and number of segments with myocardial perfusion defects 72 hours after STEMI and at 6 months of follow-up. P < 0.05 was considered statistically significant. Results Patients treated with sonothrombolysis had higher LVEF than the control group at 72 hours (50% ± 10% versus 44% ± 10%; p = 0.006), and this difference was maintained at 6 months of follow-up (53% ± 10% versus 48% ± 12%; p = 0.008). The WMSI was similar in the therapy and control groups at 72 hours (1.62 ± 0.39 versus 1.75 ± 0.40; p = 0.09), but it was lower in the therapy group at 6 months (1.46 ± 0.36 versus 1.64 ± 0.44; p = 0.02). The number of segments with perfusion defects on RTMPE was similar in therapy and control group at 72 hours (5.92 ± 3.47 versus 6.94 ± 3.39; p = 0.15), but it was lower in the therapy group at 6 months (4.64 ± 3.31 versus 6.57 ± 4.29; p = 0.01). Conclusion Sonothrombolysis in patients with STEMI resulted in improved wall motion and ventricular perfusion scores over time.

2.
Hajjar, Ludhmila Abrahão; Costa, Isabela Bispo Santos da Silva da; Lopes, Marcelo Antônio Cartaxo Queiroga; Hoff, Paulo Marcelo Gehm; Diz, Maria Del Pilar Estevez; Fonseca, Silvia Moulin Ribeiro; Bittar, Cristina Salvadori; Rehder, Marília Harumi Higuchi dos Santos; Rizk, Stephanie Itala; Almeida, Dirceu Rodrigues; Fernandes, Gustavo dos Santos; Beck-da-Silva, Luís; Campos, Carlos Augusto Homem de Magalhães; Montera, Marcelo Westerlund; Alves, Sílvia Marinho Martins; Fukushima, Júlia Tizue; Santos, Maria Verônica Câmara dos; Negrão, Carlos Eduardo; Silva, Thiago Liguori Feliciano da; Ferreira, Silvia Moreira Ayub; Malachias, Marcus Vinicius Bolivar; Moreira, Maria da Consolação Vieira; Valente Neto, Manuel Maria Ramos; Fonseca, Veronica Cristina Quiroga; Soeiro, Maria Carolina Feres de Almeida; Alves, Juliana Barbosa Sobral; Silva, Carolina Maria Pinto Domingues Carvalho; Sbano, João; Pavanello, Ricardo; Pinto, Ibraim Masciarelli F; Simão, Antônio Felipe; Dracoulakis, Marianna Deway Andrade; Hoff, Ana Oliveira; Assunção, Bruna Morhy Borges Leal; Novis, Yana; Testa, Laura; Alencar Filho, Aristóteles Comte de; Cruz, Cecília Beatriz Bittencourt Viana; Pereira, Juliana; Garcia, Diego Ribeiro; Nomura, Cesar Higa; Rochitte, Carlos Eduardo; Macedo, Ariane Vieira Scarlatelli; Marcatti, Patricia Tavares Felipe; Mathias Junior, Wilson; Wiermann, Evanius Garcia; Val, Renata do; Freitas, Helano; Coutinho, Anelisa; Mathias, Clarissa Maria de Cerqueira; Vieira, Fernando Meton de Alencar Camara; Sasse, André Deeke; Rocha, Vanderson; Ramires, José Antônio Franchini; Kalil Filho, Roberto.
Arq. bras. cardiol ; 115(5): 1006-1043, nov. 2020. tab, graf
Article in Portuguese | CONASS, LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1142267
3.
Arq. bras. cardiol ; 109(1): 23-29, July 2017. tab, graf
Article in English | LILACS | ID: biblio-887891

ABSTRACT

Abstract Background: Estimative of left ventricular ejection fraction (LVEF) is a major indication for echocardiography. Speckle tracking echocardiography (STE) allows analysis of LV contraction mechanics which includes global longitudinal strain (GLS) and twist/torsion, both the most widely used. Direct comparison of correlations between these novel parameters and LVEF has never been done before. Objective: This study aims to check which one has the highest correlation with LVEF. Methods: Patients with normal LVEF (> 0,55) and systolic dysfunction (LVEF <0,55) were prospectively enrolled, and underwent echocardiogram with STE analysis. Correlation of variables was performed by linear regression analysis. In addition, correlation among levels of LV systolic impairment was also tested. Results: A total of 131 patients were included (mean age, 46 ± 14y; 43%, men). LVEF and GLS showed a strong correlation (r = 0.95; r2 = 0.89; p < 0.001), more evident in groups with LV systolic dysfunction than those with preserved LVEF. Good correlation was also found with global longitudinal strain rate (r = 0.85; r2 = 0.73; p < 0.001). Comparing to GLS, correlation of LVEF and torsional mechanics was weaker: twist (r = 0.78; r2 = 0.60; p < 0.001); torsion (r = 0.75; r2 = 0.56; p < 0.001). Conclusion: GLS of the left ventricle have highly strong positive correlation with the classical parameter of ejection fraction, especially in cases with LV systolic impairment. Longitudinal strain rate also demonstrated a good correlation. GLS increments analysis of LV systolic function. On the other hand, although being a cornerstone of LV mechanics, twist and torsion have a weaker correlation with LV ejection, comparing to GLS.


Resumo Fundamento: A estimativa da fração de ejeção do ventrículo esquerdo (FEVE) é uma das pincipais indicações para a ecocardiografia. Speckle tracking (ST) permite a análise da mecânica de contração do VE que inclui a deformação (strain) longitudinal global (SLG) e o twist / torção, sendo ambos os mais utilizados. A comparação direta de correlações entre esses novos parâmetros e a FEVE nunca foi feita antes. Objetivo: Verificar qual delas tem a maior correlação com a FEVE. Métodos: Pacientes com FEVE normal (> 0,55) e disfunção sistólica (FEVE < 0,55) foram prospectivamente inscritos e submetidos a ecocardiograma com análise do ST. A correlação das variáveis foi realizada por análise de regressão linear. Além disso, também foi testada a correlação entre os níveis de comprometimento sistólico do VE. Resultados: Foram incluídos 131 pacientes (média de idade de 46 ± 14 anos e 43% de homens). A FEVE e SLG apresentaram forte correlação (r = 0,95; r2 = 0,89; p < 0,001), mais evidente em grupos com disfunção sistólica do VE do que naqueles com FEVE preservada. Também foi encontrada boa correlação com a taxa de deformação (strain rate) longitudinal (SRL) global (r = 0,85; r2 = 0,73; p < 0,001). Comparando-a à SLG, a correlação entre FEVE e mecânica de torção foi mais fraca: twist (r = 0,78; r2 = 0,60; p < 0,001); Torção (r = 0,75, r2 = 0,56, p < 0,001). Conclusão: A SLG do ventrículo esquerdo apresenta alta correlação positiva com o parâmetro clássico de fração de ejeção, principalmente nos casos de comprometimento sistólico do VE. O SRL também demonstrou uma boa correlação. A SLG incrementa a análise da função sistólica do VE. Por outro lado, apesar de ser a pedra angular da mecânica do VE, o twist e a torção têm uma correlação mais fraca com a ejeção do VE, quando comparados ao SLG.


Subject(s)
Humans , Male , Female , Middle Aged , Stroke Volume/physiology , Torsion Abnormality/diagnostic imaging , Ventricular Function, Left , Heart Diseases/diagnostic imaging , Echocardiography , Observer Variation , Prospective Studies , Heart Diseases/physiopathology
5.
ABC., imagem cardiovasc ; 28(1): 30-35, jan.-mar. 2015. tab, ilus
Article in Portuguese | LILACS | ID: lil-747459

ABSTRACT

Introdução: Na cardiomiopatia dilatada (CMD) de origem não isquêmica uma reserva coronariana diminuída estáassociada a maior risco de morte e um dos possíveis mecanismos é o aumento das pressões de enchimento doventrículo esquerdo. Objetivo: Avaliar a reserva de fluxo coronariano (RFC) pela Ecocardiografia Transtorácica (ETT) e comparar com graus de função diastólica.Métodos: Foram estudados 156 pacientes com CMD não isquêmica (101 homens, média etária 53 ± 12 anos) e disfunção sistólica importante. A função diastólica foi avaliada pelo fluxo transvalvar mitral, fluxo venoso pulmonar e Doppler tecidual, e classificada em: normal (Grau 0); alteração de relaxamento (Grau I); padrão pseudonormal (Grau II); restritivo com reversão à manobra de Valsalva (grau III); e restritivo sem reversão à manobra de Valsalva (Grau IV). A RFC foi determinada pelo fluxo obtido com o Doppler pulsado na artéria descendente anterior e calculada como a relação entre a velocidade diastólica máxima durante a hiperemia (dipiridamol, 0,84 mg/Kg) e no basal.Resultados: Todos os pacientes apresentavam disfunção sistólica importante, fração de ejeção média de 25,3 ± 5,7%; 86 pacientes (55%) apresentavam função diastólica grau 0 ou I, enquanto 70 pacientes (45%) apresentavam disfunção diastólicagraus II, III e IV. A exequibilidade da medida de RFC foi de 90,4%. A RFC foi significativamente maior nos pacientes com função diastólica 0 ou I (2,2 ± 0,5) do que nos pacientes com disfunção diastólica graus II, II e IV (1,9 ± 0,5; p < 0,001). Conclusões: A RFC apresenta-se reduzida em pacientes com CMD de origem não isquêmica e graus avançados de disfunção diastólica.


Introduction: In patients with nonischemic dilated cardiomyopathy (DCM), decreased coronary flow reserve is associated with increased risk of death and one of the possible mechanisms is the increased left ventricular filling pressures. Objective: To evaluate the coronary flow reserve (CFR) by transthoracic echocardiography (TTE) and compare it with degrees of diastolicfunction in patients with DCM. Methods: We studied 156 patients with DCM (101 men, mean age 53±12 years) and severe systolic dysfunction. Diastolic function was assessed by mitral inflow, pulmonary venous flow and tissue Doppler, and classified as normal (grade 0), impaired relaxation pattern (Grade 1), pseudonormal pattern (Grade 2), reversible restrictive pattern during Valsalva maneuver (Grade 3) and irreversible restrictive pattern during Valsalva maneuver (Grade 4). The CFR was determined by pulsed Doppler in left anterior descending coronary artery and calculated as the ratio of the maximumdiastolic velocity during hyperemia (dipyridamole, 0.84 mg/kg) and baseline. Results: All patients had significant systolic dysfunction, with mean left ventricular ejection fraction of 25.3±5.7%. 86 patients (55%) had grade 0 or 1 diastolic function while 70 patients (45%) had grades II, III or IV of diastolic dysfunction. The feasibility of CFR obtained by TTE was 90.4%. The CFR was significantly higher in patients with diastolic dysfunction 0 or 1 (2.2±0.5) than in patients with diastolic dysfunction grades II, II or IV (1.9±0.5, p<0.001). Conclusion: CFR is reduced in patients with nonischemic DCM and advanced degrees of diastolic dysfunction.


Subject(s)
Humans , Male , Female , Middle Aged , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/etiology , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/diagnosis , Fractional Flow Reserve, Myocardial , Heart Failure/diagnosis , Heart Failure/mortality , Echocardiography/methods , Data Interpretation, Statistical , Stroke Volume
6.
Rev. bras. ecocardiogr. imagem cardiovasc ; 24(2): 10-15, abr.-jun. 2011. tab, graf
Article in Portuguese | LILACS | ID: lil-583502

ABSTRACT

Introdução: A avaliação de pacientes com dor torácica é muitas vezes problemática. O desafio em diagnosticar corretamente a etiologia da dor torácica é dificultado pela baixa sensibilidade dos métodos diagnósticos disponíveis. Neste estudo, avaliou-se a utilidade diagnóstica da ecocardiografia com contraste miocárdico (MCE) e da cintilografia de perfusão miocárdica sincronizada ao eletrocardiograma (G-SPECT) para detecção de isquemia miocárdica. Métodos e Resultados: Dezoito pacientes atendidos no pronto socorro, para avaliação da dor torácica sugestiva de angina, foram submetidos à MCE e G-SPECT. Para ambos os métodos, a perfusão miocárdica e a mobilidade foram avaliados nos mesmos sete segmentos do ventrículo esquerdo. As imagens foram classificadas como positivas ou negativas para isquemia. Um segmento era considerado positivo na presença de um defeito da perfusão ou uma anomalia do movimento da parede. A cinecoronariografia foi realizada se MCE ou G-SPECT foram classificados como positivos para isquemia. Se ambos os exames foram negativos, o paciente foi submetido ao SPECT de estresse no dia seguinte. Sensibilidade e especificidade para detecção de isquemia miocárdica foram, respectivamente: A) G-SPECT: 1. avaliação de perfusão: 100 por cento e 75 por cento; 2. avaliação de contração: 66 por cento e 91,6 por cento; 3. associação perfusão+contração: 66 por cento e 91,6 por cento. B) MCE: 1. avaliação de perfusão: 20 por cento e 76 por cento; 2. avaliação de contração: 33,3 por cento e 83,3 por cento; 3. associação perfusão...


Subject(s)
Humans , Chest Pain/diagnosis , Chest Pain/etiology , Electrocardiography/methods , Electrocardiography , Myocardial Ischemia/complications , Myocardial Ischemia/diagnosis , Tomography, Emission-Computed, Single-Photon/methods , Tomography, Emission-Computed, Single-Photon
7.
Rev. bras. ecocardiogr. imagem cardiovasc ; 24(2): 23-29, abr.-jun. 2011. tab
Article in Portuguese | LILACS | ID: lil-583504

ABSTRACT

O ecocardiograma é um exame de grande importância do seguimento dos pacientes submetidos a transplante cardíaco. desde o período pós-cirúrgico imediato até o controle ambulatorial, anos após o procedimento. Todas as ferramentas relacionadas à ecocardiografia foram utilizadas e estudadas, no indivíduo transplantado, e constatou-se que há particularidades importantes nesse grupo de pacientes, tanto nos que obtiveram sucesso do procedimento, como naqueles que desenvolveram complicações. Uma das peculiaridades é a ocorrência do fenômeno de rejeição, quadro que ocorre quando o sistema imune do receptor ataca os antígenos do aloenxerto. Essa é uma situação frequente e alta morbimortalidade, e o diagnóstico ainda depende de procedimentos invasivos (biopsia endomiocárdica). Na busca por avaliações não invasiva para pesquisa de rejeição, foram feitos vários estudos que analisaram os dados do Eco-Doppler e, até o momento, os mais promissores, para diagnóstico precoce dessa complicação, foram os indicadores de função diastólica. Esta revisão tem como objetivo avaliar a real importância da detecção de alterações relacionadas à diástole, por meio da ecocardiografia para o screening de rejeição pós-transplante cardíaco, baseando-se nas evidências, atualmente, disponíveis e também nas recomendações das principais sociedades de cardiologia.


Subject(s)
Humans , Ventricular Dysfunction/complications , Ventricular Dysfunction/diagnosis , Echocardiography/methods , Echocardiography , Graft Rejection/complications , Heart Transplantation/trends , Risk Factors
10.
Rev. bras. ecocardiogr ; 17(3): 47-52, jul.-set. 2004. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-397768

ABSTRACT

RESUMO: Objetivo: o ecocardiograma transtorácico tridimensional em tempo real (3D) foi recentemente desenvolvido como método de avaliação da anatomia cardíaca, e por isso necessita de validação. O objetivo deste estudo foi correlacionar a mensuração da área valvar mitral (AVM) em pacientes (pts) com estenose mitral, medida pelo ecocardiograma 3D, pelo ecocardiograma bidimensional (2D) e pelo método do tempo de decaimento de meia-pressão (PHT). Métodos:)1O pts (40 + 11 anos, 6 mulheres) com estenose valvar mitral e 8 controles normais (38+8 anos, 5 mulheres) foramsubmetidos a mensuração da AVM pelo 3D, 2D e PH7: As aferições foram realizadas separadamente por 2 observadores experientes com o emprego do equipamento Philips Sonos 7500. Resultados: no grupo com estenose mitral, a AVM medida pelo 3D variou de 0,61 cm2 a 1,57 cm2, e apresentou correlação com 2D: r- 0,91(p<0,0001), e com PHT: r- 0,92 (p<0,0001). O coeficiente de correlação intraclasse para o 3D foi 0,9084 (95,00 por cento IC,0,6929-0,9761), com concordancia interobservador de 0,9102 (95,00 por cento IC, 0,7723-.0,9712). No grupo controle, a AVM medida pelo 3D variou de 2,1 cm2 a 4 cm2, apresentou correlação com 2D: r-0,98 (p<0,0001), e com o PHT: r-(),99 (p<0,0001). O coeficiente de correlação intraclasse no grupo controle, para a medida da AVM pelo 3D foi 0,9785(95,00 por cento IC, 0,9061-0,9785), com concordáncia interobservador de 0,9002 (95,00 por cento IC, 0,7443-0,9811). Conclusão: este estudo sugere que a aferição da AVM pelo 3D em pts com estenose mitral é fadível e mostrou boa correlação com métodos previamente comprovados, podendo ser considerada no futuro como técnica útil à investigação diagnóstica préoperatória.


Subject(s)
Humans , Male , Female , Adult , Echocardiography, Three-Dimensional/methods , Mitral Valve Stenosis/diagnosis , Mitral Valve/abnormalities
11.
J. bras. pneumol ; 30(1): 78-86, jan.-fev. 2004. ilus
Article in Portuguese | LILACS | ID: lil-360097

ABSTRACT

A adequada avaliação dos níveis de pressão na artéria pulmonar é fundamental para o diagnóstico e manuseio de pacientes com hipertensão arterial pulmonar (HAP) de qualquer etiologia. A ecocardiografia é um método nãoinvasivo, de baixo custo e amplamente disponível, que permite a avaliação anatômica e funcional das cavidades cardíacas direitas e a estimativa das pressões em artéria pulmonar, apresentando boa correlação com dados hemodinâmicos obtidos pelo cateterismo cardíaco. O mais preciso e confiável método utilizado pela ecocardiografia para a estimativa das pressões em artéria pulmonar é baseado na medida da velocidade do fluxo regurgitante da valva tricúspide, embora elas possam também ser estimadas pelo fluxo regurgitante pulmonar ou pela análise do fluxo sistólico pulmonar. Quando a qualidade da imagem obtida pela abordagem transtorácica não permite a avaliação adequada da anatomia cardíaca, a ecocardiografia transesofágica torna-se procedimento extremamente útil para complementar essa avaliação, permitindo, por vezes, a detecção de seus possíveis mecanismos causais. A ecocardiografia pode ser utilizada não só para o diagnóstico da HAP, mas também para orientar a conduta terapêutica e para a avaliação prognóstica desses pacientes. Em casos de tromboembolismo pulmonar agudo, já foi demonstrado que a detecção de disfunção ventricular direita pela ecocardiografia é um dado importante na indicação de terapia trombolítica. Da mesma forma, o método tem seu valor estabelecido para monitorização da resposta terapêutica em pacientes com HAP primária, na avaliação prognóstica de pacientes com doença pulmonar obstrutiva crônica e no acompanhamento de pacientes submetidos a transplante pulmonar.


Subject(s)
Humans , Echocardiography, Doppler , Hypertension, Pulmonary
12.
Radiol. bras ; 31(6): 349-54, dez. 1998. ilus, tab
Article in Portuguese | LILACS | ID: lil-267841

ABSTRACT

Resumo: Este estudo visa fazer a correlaçäo entre a clínica, a ecocardiografia transtorácica (ETT) e a ecocardiografia transesofgica (ETE) no diagnóstico diferencial dos defeitos do septo interatrial (DSIA) e hipertensäo pulmonar (HP) em adultos. Realizamos ETT a ETE em 30 pacientes com diagnóstico de DSIA baseado em critérios de ausculta cardíaca, radiológicos e eletrocardiográficos. Três critérios, em 16 pacientes (grupo B). Foram determinados a sensibilidade, a especificidade, a acurácia e os valores preditivos positivo e negativo para a ETT, admitindo-se os resultados da ETE como ''gold standard''. A sensibilidade da ETT para o diagnóstico de DSIA é baixa 50 (por cento), a especificidade é de 75-90 (por cento), a acurária de 60-66 (por cento), o valor preditivo positivo de 75-83 (por cento), e o valor preditivo negativo de 37-75 (por cento), näo sendo capaz de diagnosticar os DSIAs tipo seio venoso. Catorze pacientes 46,6 (por cento) apresentaram diagnóstico final de HP, näo estando relacionada a DSIA


Subject(s)
Humans , Male , Female , Middle Aged , Adult , Echocardiography , Echocardiography, Transesophageal , Heart Septal Defects, Atrial , Heart Septal Defects, Atrial/diagnosis , Hypertension, Pulmonary/diagnosis
13.
Rev. bras. cir. cardiovasc ; 7(4): 235-42, out.-dez. 1992. ilus, tab
Article in Portuguese | LILACS | ID: lil-164372

ABSTRACT

A ecodopplercardiografia ocupa posiçao de destaque no diagnóstico das valvopatias, pois fornece dados sobre a anatomia valvar, a área estenótica, os gradientes pressóricos e o grau da regurgitaçao. Seu uso na cirurgia cardíaca, com a abordagem epicárdiaca, é bastante conhecido. O advento da abordagem transeofágica, por nao interferir no campo operatório, facilitou a sua utilizaçao. O objetivo deste trabalho foi estudar a utilidade da ETE na cirurgia da valva mitral. De julho de 1991 a janeirode l992, a ecodopplercardiografia transesofágica (ETE) monitorizou 198 cirurgias, das quais 65 foram sobre a valva mitral (VM). A idade variou de 8 a 62 anos e 42 pacientes eram do sexo feminino. A comissurotomia e papilarotomia (CP) foi o procedimento mais freqüente em 28 pacientes (pts), seguido do implante de bioprótese (BP) em 24 e da plastia (PL) em 19. A ETE pré-operatória confirmou o diagnóstico da lesao mitral em todos os pts, tendo acrescentado informaçoes quanto ao grau e direçao da insuficiência mitral (IM) em 8 dos 28 pts submetidos a CP. Modificou a orientaçao da abordagem da valva tricúspide em 9 oportunidades (3 por diagnosticar lesoes nao detectadas e 6 por evitar a abordagem desnecessária por melhor avaliaçao da lesao. Quanto aos pts submetidos a implante de BP, 6 já tinham próteses disfuncionantes, em 12 pts a BP foi implantada de imediato por decisao do cirurgiao e, em 6 pts, a BP foi implantada após a detecçao da presença de IM importante pós-correçao. Quanto ao pts submetidos a PL, 12 tinham prolapso, 6 tinham insuficiência coronária e 1 era pós-operatório tardio de correçao de defeito do septo atrioventricular. Em apenas l pt foi necessária nova CEC para nova plastia. A avaliaçao da IM pós CEC evidenciou 7 pts (lO por cento) com IM importante, sendo necessária nova CEC, e mostrou IM leve em 15 pts, moderada em 8 e importante em l onde nao foi realizada nova CEC. A ETE é um método de grande valor no auxílio do planejamento cirúrgico nas doenças da VM, bem como na avaliaçao imediata dos resultados operatórios possibilitando ao cirurgiao uma adequada análise anatômica e funcional da estrutura abordada.


Subject(s)
Female , Humans , Adolescent , Middle Aged , Child , Adult , Echocardiography, Doppler , Mitral Valve Insufficiency/surgery , Heart Valve Prosthesis , Intraoperative Care , Mitral Valve Insufficiency/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL