Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Journal of Pharmaceutical Analysis ; (6): 69-74, 2018.
Article in Chinese | WPRIM | ID: wpr-700355

ABSTRACT

Five different quorum sensing peptides (QSP) were iodinated using different iodination techniques. These iodinated peptides were analyzed using a C18 reversed phase HPLC system, applying a linear gradient of water and acetonitrile containing 0.1% (m/v) formic acid as mobile phase. Electrospray ionization (ESI) ion trap mass spectrometry was used for the identification of the modified peptides, while semi-quan-tification was performed using total ion current (TIC) spectra. Non-iodinated peptides and mono-and di-iodinated peptides (NIP, MIP and DIP respectively) were well separated and eluted in that order. De-pending on the used iodination method, iodination yields varied from low (2%) to high (57%).

2.
Journal of Pharmaceutical Analysis ; (6): 27-32, 2015.
Article in Chinese | WPRIM | ID: wpr-672143

ABSTRACT

The sample preparation of samples containing bovine serum albumin (BSA), e.g., as used in transdermal Franz diffusion cell (FDC) solutions, was evaluated using an analytical quality-by-design (QbD) approach. Traditional precipitation of BSA by adding an equal volume of organic solvent, often successfully used with conventional HPLC-PDA, was found insufficiently robust when novel fused-core HPLC and/or UPLC-MS methods were used. In this study, three factors (acetonitrile (%), formic acid (%) and boiling time (min)) were included in the experimental design to determine an optimal and more suitable sample treatment of BSA-containing FDC solutions. Using a QbD and Derringer desirability (D) approach, combining BSA loss, dilution factor and variability, we constructed an optimal working space with the edge of failure defined as Do0.9. The design space is modelled and is confirmed to have an ACN range of 8373%and FA content of 170.25%.

3.
Journal of Pharmaceutical Analysis ; (6): 169-181, 2015.
Article in Chinese | WPRIM | ID: wpr-671990

ABSTRACT

Peptides are becoming an important class of molecules in the pharmaceutical field. Closely related peptide-impurities in peptides are inherent to the synthesis approach and have demonstrated to potentially mask biomedical experimental results. Quorum sensing peptides are attracting high interest in R&D and therefore a representative set of quorum sensing peptides, with a requested purity of at least 95.0%, was evaluated for their purity and nature of related impurities. In-house quality control (QC) revealed a large discrepancy between the purity levels as stated on the supplier’s certificate of analysis and our QC results. By using our QC analysis flowchart, we demonstrated that only 44.0% of the peptides met the required purity. The main compound of one sample was even found to have a different structure compared to the desired peptide. We also found that the majority of the related impurities were lacking amino acid(s) in the desired peptide sequence. Relying on the certificates of analysis as provided by the supplier might have serious consequences for peptide research, and peptide-researchers should implement and maintain a thorough in-house QC.

4.
Journal of Pharmaceutical Analysis ; (6): 37-52, 2014.
Article in Chinese | WPRIM | ID: wpr-672128

ABSTRACT

A highly selective and stability-indicating HPLC-method, combined with appropriate sample preparation steps, is developed for β-artemether assay and profiling of related impurities, including possible degradants, in a complex powder for oral suspension. Following HPLC conditions allowed the required selectivity: a Prevail organic acid (OA) column (250 mm×4.6 mm, 5μm), flow rate set at 1.5 mL/min combined with a linear gradient (where A ? 25 mM phosphate buffer (pH 2.5), and B ? acetonitrile) from 30% to 75% B in a runtime of 60 min. Quantitative UV-detection was performed at 210 nm. Acetonitrile was applied as extraction solvent for sample preparation. Using acetonitrile-water mixtures as extraction solvent, a compartmental behaviour by a non-solving excipient-bound fraction and an artemether-solubilising free fraction of solvent was demonstrated, making a mobile phase based extraction not a good choice. Method validation showed that the developed HPLC-method is considered to be suitable for its intended regulatory stability-quality characterisation of β-artemether paediatric formulations. Furthermore, LC-MS on references as well as on stability samples was performed allowing identity confirmation of the β-artemether related impurities. MS-fragmentation scheme of β-artemether and its related substances is proposed, explaining the m/z values of the in-source fragments obtained.

5.
Journal of Pharmaceutical Analysis ; (6): 303-315, 2014.
Article in Chinese | WPRIM | ID: wpr-672115

ABSTRACT

Pharmaceutical excipients for topical use may contain impurities, which are often neglected from a toxicity qualification viewpoint. The possible impurities in the most frequently used topical excipients were evaluated in-silico for their toxicity hazard. Acetol, an impurity likely present in different topical pharmaceutical excipients such as propylene glycol and glycerol, was withheld for the evaluation of its health risk after dermal exposure. An ex-vivo in-vitro permeation study using human skin in a Franz Diffusion Cell set-up and GC as quantification methodology showed a significant skin penetration with an overall Kp value of 1.82 ? 10 ? 3 cm/h. Using these data, limit specifications after application of a dermal pharmaceutical product were estimated. Based on the TTC approach of Cramer class I substances, i.e. 1800 mg/(day?person), the toxicity-qualified specification limits of acetol in topical excipients were calculated to be 90 mg/mL and 180 mg/mL for propylene glycol and glycerol, respectively.

6.
Journal of Pharmaceutical Analysis ; (6): 330-334, 2013.
Article in Chinese | WPRIM | ID: wpr-672153

ABSTRACT

As part of the method development, the injection volume as a critical quality attribute in fast fused-core chromatography was evaluated. Spilanthol, a pharmaceutically interesting N-alkylamide currently under investigation in our laboratory, was chosen as the model compound. Spilanthol was dissolved in both PBS and MeOH/H2O (70/30, v/v) and subsequently analyzed using a fused-core system hereby selecting five chromatographic characteristics (retention time, area, height, theoretical plates and symmetry factor) as responses. We demonstrated that the injection volume significantly influenced both the qualitative and quantitative performance of fused-core chromatography, a phenomenon which is confounded with the nature of the used sample solvent. From 2 mL up to 100 mL injection volume with PBS as solvent, the symmetry factor decreased favorably by 20%. Moreover, the theoretical plates and the quantitative parameters (area and height) increased up to 30%. On the contrary, in this injection volume range, the theoretical plates for the methanol-based samples decreased by more than 60%, while the symmetry factor increased and the height decreased, both by 30%. The injection volume is thus a critical and often overlooked parameter in fused-core method description and validation.