Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Braz. oral res. (Online) ; 37: e017, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420944

ABSTRACT

Abstract The aim of this study was to evaluate the effect of different die materials used in the indirect resin composite restorative technique on the fracture resistance and failure mode of restored molars and compare it with the direct resin composite restorative technique. Two flexible die silicone materials for dental models (Die Silicone - Voco and Scan die - Yller) and a type IV dental stone material (Fujirock EP - GC) were evaluated. Sixty third molars were selected and divided into four groups: indirect resin composite restoration - Die silicone (IRCR-DS); indirect resin composite restoration - Scan die (IRCR-SD); indirect resin composite restoration - Fujirock EP (IRCR-FR), and direct resin composite restoration (DRCR). Class II MOD cavities were prepared with 5 mm of buccolingual width and depth. The specimens were restored and subjected to an axial compression load until fracture, and the data were analyzed by one-way ANOVA and Tukey's HSD test (α=.05). The fracture mode was classified into restorable and unrestorable fractures. Fracture resistance values were influenced by the die material used for the IRCR fabrication and by the restorative technique (p<.001). Fracture resistance mean values and standard deviation were: IRCR-DS: 1835.5 ± 324.0 A; IRCR-SD: 1732.5 ± 384.1 AB; IRCR-FR: 1419.3 ± 318.8 BC; and DRCR: 1100.6 ± 224.9 C. Restorable fracture was more prevalent. IRCR with flexible die casts promoted higher fracture resistance and lower prevalence of unrestorable fractures.

2.
RGO (Porto Alegre) ; 68: e20200055, 2020. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1136055

ABSTRACT

ABSTRACT Objective To compare dimensions of natural maxillary anterior teeth and several denture teeth molds and also address differences between genders. Methods A single examiner with a digital caliper measured dental casts of 41 males and 55 females in order to determine CIW (central incisor width), CIL (central incisor length) and WS (width of anterior teeth on a straight line). In addition, WC (width of anterior teeth on a curve) was measured with a flexible ruler. These parameters were also observed on three denture teeth mold charts: Premium Pala, Vivodent and Trilux. The comparison between genders was analyzed using Student's t-test (?=.05), while absolute frequencies within several ranges were used to compare natural and denture teeth. Results CIW, CIL, WS and WC obtained from males were significantly higher than those found for females (p<0.05). CIW of nearly half of natural and denture teeth were within 8.0-8.5 mm. Almost half of natural teeth presented CIL values within 10.6-11 mm, while the highest frequency of denture teeth was observed within 9.6-10 mm. The majority of natural and denture teeth presented WS values within 42 to 49 mm. Only one denture teeth chart described WC values, which were mainly observed within 44-51 mm, while the majority of WC values obtained from natural teeth ranged from 48 to 55 mm. Conclusion Some commercially available denture teeth present dimensions not observed in natural teeth. Teeth dimensions in function of gender differences must be considered when selecting denture teeth.


RESUMO Objetivo Comparar as dimensões dos dentes anteriores superiores naturais e de diversos dentes artificiais para próteses e também abordar as diferenças entre os gêneros. Métodos Um único examinador mediu com um paquímetro digital dentes naturais de 41 homens e 55 mulheres para determinar CIW (largura do incisivo central), CIL (comprimento do incisivo central) e WS (largura dos dentes anteriores superiores em linha reta). Adicionalmente, CC (largura dos dentes anteriores em uma curva) foi aferida com uma régua flexível. Esses parâmetros também foram observados em três cartas moldes de dentes artificiais para prótese: Premium Pala, Vivodent e Trilux. A comparação entre os sexos foi analisada pelo teste t de Student (?=0,05), enquanto frequências absolutas foram usadas para comparar medidas dos dentes naturais e artificiais. Resultados CIW, CIL, WS e WC obtidos de homens foram significativamente maiores do que aqueles encontrados para mulheres (p<0,05). CIW de quase metade de dentes naturais e artificiais estavam entre 8,0-8,5 mm. Quase metade dos dentes naturais apresentaram valores CIL entre 10,6-11 mm, enquanto a maior frequência de dentes artificiais foi observada entre 9,6-10 mm. A maioria dos dentes naturais e artificiais apresentaram valores WS entre 42-49 mm. Apenas uma carta molde de dentes artificiais descreveu os valores de WC, que foram observados principalmente entre 44-51 mm, enquanto a maioria dos valores de WC obtidos em dentes naturais variaram de 48 a 55 mm. Conclusão Alguns dentes artificiais para próteses disponíveis comercialmente apresentam dimensões não observadas nos dentes naturais. As dimensões dos dentes em função das diferenças de gênero devem ser consideradas na seleção dos dentes artificiais.

3.
Rev. Bras. Odontol. Leg. RBOL ; 6(1): 2-12, jan-abr 2019.
Article in English | LILACS | ID: biblio-997167

ABSTRACT

Introduction: Physical violence became an important global problem in the last decades. This scenario is reflected in the increasing jurisprudence. In specific situations, perpetrators and victims of physical violence may inflict an especial patterned injury named bitemark. Knowing the case characteristics in lawsuits involving human bites and bitemarks is important to understand and encourage the role of Forensic Dentists as expert witness for bitemark analysis in Court. Objectives: The present study aimed to assess the jurisprudence to screen lawsuits that involve human bites and bitemarks in order to extract characteristics that could support research and practice of bitemark analysis. Material and methods: A systematic search was conducted in an open access jurisprudence system with the keywords "bite" and "bitemark". Full-texts of lawsuits were selected and underwent data extraction. Results: A total of 2488 lawsuits were detected, from which 1125 were eligible in the present study. The lawsuits dated between 1997 (n=13, 1.15%) and 2015 (n=202, 17.95%). Forensic expertises were performed in 641 (56.97%) lawsuits, but the identity of suspects was investigated only in 3 (0.26%) cases. Conclusions: An increasing trend of lawsuits involving human bites and bitemarks was observed. Forensic Dentists must be aware of the current bitemark scenario as well the limitations inherent to bitemark analysis to face casework in the field. The present study provides evidence to encourage major education in bitemark analysis.


Introdução: Ao longo dos anos a violência física vem se tornando um grande problema global que tem mostrado seu reflexo no aumento do número de jurisprudências envolvendo o assunto. Em alguns casos o agressor e a vítima podem produzir o mesmo padrão de injúria física, como a marca de mordida. Sabendo que as marcas de mordida e mordeduras humanas podem estar presentes em casos que envolvam ações judiciais é muito importante entender e incentivar a atuação do perito odontolegista para análise das marcas de mordida em processos judiciais. Objetivo: Analisar acórdãos que estivessem relacionados às marcas de mordidas e que pudessem subsidiar a rotina de marcas de mordida e a prática de análise dessas marcas. Materiais e métodos: Foi realizada uma busca sistematizada de acórdãos no Tribunal de Justiça de São Paulo utilizando as seguintes palavras-chave: mordida, dentada e mordedura. Apenas os acórdãos que estavam disponíveis em inteiro teor foram avaliados para captação dos dados que foram tabulados em uma planilha própria da pesquisa. Resultados: Foram detectados 2488 acórdãos, dos quais 1125 foram compatíveis com os critérios de elegibilidade, e datados entre os anos de 1997 a 2015. A análise pericial foi realizada em 641 (56,97%) casos, sendo o agressor identificado pela mordida em apenas 3 (0,26%) casos. Conclusão: Houve um significativo aumento em processos judiciais envolvendo marcas de mordida. Os odontolegistas devem estar cientes da ocorrência das marcas de mordida no cenário das agressões físicas bem como as limitações inerentes à análise dessas marcas frente ao campo de atuação dos peritos odontolegistas. O presente estudo fornece evidências para incentivar o aumento do estudo da análise das marcas de mordida.

4.
RGO (Porto Alegre) ; 66(3): 267-273, July-Sept. 2018. graf
Article in English | LILACS | ID: biblio-984900

ABSTRACT

ABSTRACT Cranioencephalic trauma which results in extensive edema and / or bruising usually requires surgical treatment through a greater withdrawal of the bone portion. Thus, the absence of bone tissue implies the lack of protection of the brain tissue or even compromises the esthetics especially when located in the frontal or frontoparietal region. The purpose of this case report is to describe a treatment option for head trauma, through the prefabricated part by obtaining the skull model. These bone faults can be reconstructed either by the direct method using polymethylmethacrylate directly on the defects or by means of pre-made pieces such as prototyping or from the skull model. Although other techniques have many good points, some show certain drawbacks, from storage conditions below abdominal fat, preheating due to the release of heat during the high polymerization reaction or the high cost when they are prototyped. The technique described in this work reports its simple performance, eliminating the risk of local heating, allows prior sterilization in autoclave, it is biocompatible, allows perfect anatomical recovery, easy placement, low cost, also highlighs the advantage of the bucomaxillofacial surgeon's performance due to the familiarization with the relevant head and neck procedures. Clinical and tomographic examination after 24 months of treatment showed stability of the polymethylmethacrylate plate, adhesions to the bone margins, and absence of tissue alterations.


RESUMO Os traumatismos cranioencefálicos que resultam em extensos edemas e ou hematomas normalmente, requerem tratamentos cirúrgicos por meio de uma retirada maior de porção óssea. Deste modo, a ausência do tecido ósseo implica na falta de proteção do tecido cerebral ou até mesmo comprometer a estética especialmente, quando localizadas na região frontal ou frontoparietal. O objetivo deste relato de caso é descrever uma opção de tratamento para os traumatismos cranioencefálicos, por meio da peça pré-fabricada mediante a obtenção do modelo do crânio. Estas falhas ósseas podem ser reconstruídas tanto pelo método direto utilizando o polimetilmetacrilato diretamente sobre as falhas ou por meio das peças pré-confeccionadas como a prototipagem ou a partir do modelo do crânio. Embora outras técnicas apresentem muitos pontos positivos, algumas mostram determinados inconvenientes, desde condição de armazenamento abaixo da gordura abdominal, aquecimento prévio devido a liberação de calor durante a reação de alto polimerização ou o alto custo quando são prototipadas. A técnica neste trabalho descrita relata sua facilidade de execução, elimina o risco do aquecimento local, permite a prévia esterilização em autoclave, é biocompatível, permite a perfeita recuperação anatômica, fácil colocação, baixo custo, ressaltando ainda a vantagem da atuação do cirurgião bucomaxilofacial devido sua familiarização com os procedimentos pertinentes a cabeça e pescoço. Em exame clínico e tomográfico após 24 meses do tratamento, observa-se estabilidade da placa de polimetilmetacrilato, aderências às margens ósseas, e ausência de alterações tissulares.

5.
ROBRAC ; 26(76): 1-6, jan./mar. 2017. graf
Article in Portuguese | LILACS | ID: biblio-875289

ABSTRACT

Introdução: O boxplot é um recurso gráfico usado regularmente na pesquisa científica para sumarizar e analisar dados quantitativos. Objetivo: Descrever didaticamente a estrutura, interpretação, construção, modificações e aplicações deste recurso visual. Resultados: O boxplot tradicional exibe medidas de tendência central não-paramétrica (mediana), de dispersão (quartis), forma de distribuição ou simetria da amostra (valores pontuais mínimo e máximo), valores atípicos (outliers) e extremos. Modificações podem ser incorporadas para possibilitar a inserção de parâmetros como média, desvio padrão e intervalo de confiança. As aplicações incluem análise exploratória dos dados, detecção de outliers e comparação entre grupos (equivalência). Conclusão: O boxplot é um recurso gráfico aperfeiçoado que cumpre com a análise exploratória e até mesmo inferencial dos dados e pode substituir o uso de tabelas em casos específicos.


Introduction: The boxplot is a graphics feature used regularly in this scientific research in various statistical software. Objective: To describe didactically the structure, interpretation, modifications and applications of this graphic feature. Results: The traditional boxplot displays the central trend data nonparametric (median), dispersion (quartiles), the form of distribution or symmetry (point maximum and minimum values) of the sample, and outlier. The boxplot has been modified with a view to inclusion of other properties such as the arithmetic mean and confidence interval. Applications can be compiled for exploratory data analysis, outlier detection, comparison between groups (equivalence) and multivariate data analysis. Conclusion: The boxplot is a graph feature that can replace the use of tables in specific cases.

6.
J. appl. oral sci ; 24(5): 509-517, Sept.-Oct. 2016. tab, graf
Article in English | LILACS, BBO | ID: lil-797983

ABSTRACT

ABSTRACT Tooth bleaching is a technique of choice to obtain a harmonious smile, but bleaching agents may damage the dental pulp. Objective: This study evaluated the inflammatory responses of human dental pulp after the use of two bleaching techniques. Material and Methods: Pulp samples were collected from human third molars extracted for orthodontic reasons and divided into three groups: control - no tooth bleaching (CG) (n=7); at-home bleaching with 15% carbamide peroxide (AH) (n = 10), and in-office bleaching with 38% hydrogen peroxide (IO) (n=12). Pulps were removed and stained with hematoxylin-eosin for microscopic analysis of inflammation intensity, collagen degradation, and pulp tissue organization. Immunohistochemistry was used to detect mast cells (tryptase+), blood vessels (CD31+), and macrophages (CD68+). Chi-square, Kruskal-Wallis, and Mann Whitney tests were used for statistical analysis. The level of significance was set at p<.05. Results: The inflammation intensity and the number of macrophages were significantly greater in IO than in AH and CG (p<0.05). The results of CD31+ (blood vessels per mm2) were similar in CG (61.39±20.03), AH (52.29±27.62), and IO (57.43±8.69) groups (p>0.05). No mast cells were found in the pulp samples analyzed. Conclusion: In-office bleaching with 38% hydrogen peroxide resulted in more intense inflammation, higher macrophages migration, and greater pulp damage then at-home bleaching with 15% carbamide peroxide, however, these bleaching techniques did not induce migration of mast cells and increased the number of blood vessels.


Subject(s)
Humans , Pulpitis/chemically induced , Tooth Bleaching/adverse effects , Dental Pulp/drug effects , Tooth Bleaching Agents/toxicity , Peroxides/toxicity , Pulpitis/pathology , Time Factors , Tooth Bleaching/methods , Urea/analogs & derivatives , Urea/toxicity , Blood Vessels/drug effects , Blood Vessels/pathology , Immunohistochemistry , Antigens, Differentiation, Myelomonocytic , Random Allocation , Antigens, CD , Cell Count , Collagen/drug effects , Statistics, Nonparametric , Platelet Endothelial Cell Adhesion Molecule-1 , Dental Pulp/pathology , Hydrogen Peroxide/toxicity
7.
Biosci. j. (Online) ; 32(5): 1422-1427, sept./oct 2016. ilus, tab
Article in English | LILACS | ID: biblio-965773

ABSTRACT

Objective: The present study aimed to investigate the potential of permanent canines for sexual dimorphism in a Brazilian population. Methods: The sample consisted of 172 dental casts from females (n=102) and males (n=70) aged between 13 and 49 years old. Each dental cast underwent mesiodistal (MD) and buccolingual (BL) measurement of the permanent canines using a digital caliper and a bow compass. MD and BL dimensions were compared between sex groups using Student's t-test for independent samples. Results: Statistically significant differences were observed comparing the odontometric information between females and males (p<0.05). Conclusion: These findings indicate that permanent canines have metric characteristics to enable sexual dimorphism, becoming useful for Brazilian forensic services.


Objetivo: O presente estudo objetivou avaliar o potencial de caninos permanentes para dimorfismo sexual aplicado à prática forense. Métodos: A amostra consistiu de 172 modelos de gesso odontológicos de pacientes do sexo feminino (n=102) e masculino (n=70) de idades entre 13 e 49 anos. Cada modelo odontológico foi submetido à mensuração dos diâmetros mesiodistal (MD) e bucolingual (BL) utilizando um paquímetro digital e um compasso de ponta seca. Os valores obtidos para cada diâmetro foram comparados entre sexos por meio do teste T de Student para amostras independentes. Resultados: Diferenças com significância estatística foram observadas comparando os achados obtidos para os sexos feminino e masculino (p<0.05). Conclusão: Estes resultados indicam que os caninos permanentes apresentam características morfométricas capazes de diferenças sexos, sendo uma ferramenta útil para os serviços de Odontologia e Antropologia Forense do Brasil.


Subject(s)
Sex Characteristics , Forensic Anthropology , Cuspid , Forensic Dentistry , Odontometry
8.
ImplantNews ; 12(2): 235-243, 2015. ilus
Article in Portuguese | LILACS | ID: lil-757851

ABSTRACT

O objetivo deste caso clínico foi relatar o tratamento de uma discrepância maxilomandibular de 5 mm através de enxertos da calota craniana para futura colocação de implantes dentários. Uma paciente de 65 anos de idade queixava-se da dificuldade de mastigar e do suporte labial inadequado com sua prótese total superior. Após a anamnese, exames intra e extraoral e por imagem, oito blocos ósseos foram removidos da calota craniana e fixados na região vestibular do rebordo alveolar. Depois, seis implantes (3,5-4,5 mm x 8-11 mm) foram colocados na maxila, porém, com a prótese provisória ficando suportada apenas por dois implantes provisórios (2,5 x 18 mm) para aguardar o tempo de consolidação do enxerto e dos implantes definitivos. Após cinco anos de acompanhamento, esta estratégia clínica se mostrou efetiva na estabilidade da correção do suporte labial e da discrepância maxilomandibular...


The aim of this clinical case was to report the treatment of a 5 mm maxillomandibular discrepancy using calvarial bone grafts for further dental implant placement. A 65-years-old patient had claims of poor mastication and inadequate lip support with her complete denture. After clinical and tomographic exams, 8 bone blocks were harvested from the calvarium region and secured at the buccal aspect of the alveolar maxillary ridge. After, six implants (3.5-4.5 mm x 8-11 mm) were installed; however, the provisional prosthesis was supported only by two provisional implants (2.5 x 18 mm) allowing for proper graft consolidation and implant osseointegration. After fi ve years of follow-up, this clinical strategy proved to be efficient to stabilize the lip support and the maxillomandibular discrepancy...


Subject(s)
Humans , Female , Aged , Bone Transplantation , Dental Implants , Mouth Rehabilitation , Transplantation, Autologous , Maxilla
9.
Braz. dent. j ; 19(3): 209-213, 2008. ilus, graf
Article in English | LILACS | ID: lil-495974

ABSTRACT

The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment. The castings were made on a vacuum-pressure machine, under vacuum and argon atmosphere. Each group was subdivided in three, corresponding to 0.25 mm, 0.50 mm and 0.75 mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. The specimens were subjected to an insertion/removal test and data was analyzed statistically to compare CP Ti and Co-Cr alloy in the same undercut (Student's t-test for independent samples) and each material in different undercuts (one-way ANOVA) (p=0.05). Comparisons between materials revealed significant differences (p=0.017) only for the 0.50-mm undercut. No significant differences (p>0.05) were found when comparing the same material for the undercuts. It may be concluded that for different undercuts, both Co-Cr alloy and CP Ti had no significant differences for T-bar clasps; CP Ti showed the lowest retention force values when compared to Co-Cr alloy in each undercut, but with significant difference only for the 0.50-mm undercut; and both materials maintained the retentive capacity during the simulation test.


O objetivo deste estudo foi avaliar a força de retenção de grampos tipo barra T confeccionados em titânio cp e liga de Co-Cr, através do ensaio de simulação de uso de estruturas metálicas por um período de 5 anos. Sobre modelos de revestimento que simulavam uma extremidade livre unilateral, foram fundidas 36 estruturas em titânio cp (n=18) e em Co-Cr (n=18) utilizando padrões pré-fabricados. As fundições foram feitas em máquina de vácuo-pressão sob vácuo e atmosfera inerte de argônio. Cada grupo foi subdividido em três correspondendo às retenções de 0,25 mm, 0,50 mm e 0,75 mm, respectivamente. Para manter a uniformidade dos grampos, não foram realizados procedimentos de polimento. Os corpos-de-prova foram submetidos ao teste de inserção e remoção e os dados foram analisados estatisticamente (p=0,05) para comparar Ti cp e Co-Cr na mesma retenção (teste T de Student para amostras independentes) e cada material nas diferentes retenções (análise de variância a um fator). A comparação entre os materiais revelou diferença significativa apenas para retenção de 0,50 (p=0,017). Não foram encontradas diferenças quando se comparou o mesmo material nas diferentes retenções (p>0,05). Pode-se concluir que para as diferentes retenções, grampos barra T confeccionados em liga de Co-Cr e titânio não apresentaram diferença estatisticamente significante; o titânio apresentou menores valores de retenção quando comparado à liga de Co-Cr em cada uma das retenções, mas diferença estatisticamente significante só foi encontrada para a retenção 0,50-mm; e ambos materiais mantiveram a capacidade retentiva durante o teste de simulação de uso.


Subject(s)
Humans , Chromium Alloys/chemistry , Dental Clasps , Denture Design , Denture Retention , Denture, Partial, Removable , Dental Materials/chemistry , Titanium/chemistry , Argon/chemistry , Dental Polishing , Materials Testing , Pressure , Stress, Mechanical , Surface Properties , Vacuum
10.
RGO (Porto Alegre) ; 55(2): 181-189, abr.-jun. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-466453

ABSTRACT

Em virtude de propriedades como excelente biocompatibilidade, alta resistência à corrosão e baixo peso específico, o titânio tem se tornado um material de grande interesse para a odontologia, sendo largamente utilizado nos implantes e nas cirurgias ortognáticas. Recentemente, o titânio vem sendo considerado uma alternativa viável para a confecção de estruturas metálicas em próteses parciais removíveis, tanto na sua forma pura (99,75% puro), como sob a forma de ligas (Ti-6Al-4V; Ti-6Al-7Nb). Baseado numa revisão de literatura, o presente trabalho estudou o uso do titânio na confecção de estruturas metálicas em próteses parciais removíveis, destacando as vantagens, desvantagens e características desse metal. Pode-se concluir que o uso do titânio é uma opção conveniente para reabilitação de arcos parcialmente desdentados com resultados clínicos bastante satisfatórios e promissores. Contudo, a necessidade de laboratórios altamente equipados eleva o custo, impedindo sua utilização em larga escala


Subject(s)
Dental Alloys , Denture, Partial, Removable , Titanium
11.
Ciênc. odontol. bras ; 9(3): 32-40, jul.-set. 2006. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-457447

ABSTRACT

Um dos maiores obstáculos para o sucesso das eabilitações sobre implantes consiste na obtenção de boa adaptaçãomarginal dos componentes protéticos. Não está claro na literatura quais níveis de desajuste são considerados clinicamente aceitáveis, mas sabe-se que desadaptações protéticas podem provocar problemas mecânicos e biológicos. O presente estudo tem como objetivo utilizar testes classicamente empregados nas pesquisas científicas para calcular e propor a obtenção de diferentes parâmetros de adaptação marginal. Para tanto, analisou-se estruturas metálicas simulando barras para próteses fixas tipo protocolo fundidas em diferentes materiais, mensurando as desadaptações entre as estruturas e ospilares intermediários em microscópio ótico, com o teste de único parafuso, com aperto bilateral alternado nos implantes distais 1 e 5, e com todos os parafusos apertados com um torque de 10Ncm. Esses dados possibilitaram a obtenção de diferentes parâmetros de adaptação marginal: passividade, passividade média, desajuste vertical, redução de desajuste e percentual de redução de desajuste. De acordo com a análise estatística dos resultados (p<0,05), não houve diferenças entre os dados de passividade com aperto em 1 e em 5 para nenhum dos metais utilizados (Ti p=0,421; Co-Cr p=0,635;Ni-Cr-Ti p=0,260). Contudo, houve diferenças significantes entre os valores de passividade e os valores de desajustevertical para todos os metais empregados (p=0,000), demonstrando que existe uma redução de desadaptação que deve ser levada em consideração. Pode-se concluir que a adaptação marginal deve ser estudada sob diferentes parâmetros, os quais podem possibilitar uma análise mais profunda e detalhada dos problemas relacionados aos desajustes protéticos.


Subject(s)
Dental Marginal Adaptation , Dental Prosthesis, Implant-Supported , Evaluation Study , Dental Implants
SELECTION OF CITATIONS
SEARCH DETAIL