Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add filters








Year range
1.
Japanese Journal of Cardiovascular Surgery ; : 321-324, 2010.
Article in Japanese | WPRIM | ID: wpr-362036

ABSTRACT

We report a case of tricuspid infective endocarditis with peripheral pulmonary artery aneurysm. A 31-year-old man with a history of intravenous drug abuse was admitted to our institution. Echocardiography showed severe tricuspid valve insufficiency and large vegetation (10 mm) attached to the tricuspid valve. Computed tomography (CT) revealed a right peripheral pulmonary artery aneurysm. We operated because of the large amount of vegetation. Before the operation, we performed coil embolization for peripheral pulmonary aneurysm. During the operation, we removed the posterior leaflet with vegetation, and performed tricuspid valve repair. The postoperative course was uneventful. Postoperative echocardiography did not show any tricuspid valve insufficiency or vegetation.

2.
Japanese Journal of Cardiovascular Surgery ; : 34-36, 2010.
Article in Japanese | WPRIM | ID: wpr-361970

ABSTRACT

Infectious endocarditis associated with <i>Streptococcus bovis</i>, which is rare in Japan, is a frequently reported complication of gastrointestinal tumors, especially in colon cancer. We report a patient who was successfully treated for the <i>S. bovis</i>-induced infectious endocarditis complication in colon cancer. A 60-year-old man was admitted to our hospital for detailed examination of high fever of unknown origin, that had lasted for 2 months. <i>S. bovis </i>was identified in the venous blood culture. An echocardiogram showed severe aortic valve regurgitation of the third degree and vegetation on the aortic valve. We therefore diagnosed infectious endocarditis. Colonoscopy revealed sigmoid colon cancer. After endoscopic mucosal resection of the lesion, the aortic valve was replaced. The postoperative course was uneventful and he was discharged from the hospital 36 days post operatively.

3.
Japanese Journal of Cardiovascular Surgery ; : 34-36, 2010.
Article in Japanese | WPRIM | ID: wpr-376885

ABSTRACT

Infectious endocarditis associated with <i>Streptococcus bovis</i>, which is rare in Japan, is a frequently reported complication of gastrointestinal tumors, especially in colon cancer. We report a patient who was successfully treated for the <i>S. bovis</i>-induced infectious endocarditis complication in colon cancer. A 60-year-old man was admitted to our hospital for detailed examination of high fever of unknown origin, that had lasted for 2 months. <i>S. bovis </i>was identified in the venous blood culture. An echocardiogram showed severe aortic valve regurgitation of the third degree and vegetation on the aortic valve. We therefore diagnosed infectious endocarditis. Colonoscopy revealed sigmoid colon cancer. After endoscopic mucosal resection of the lesion, the aortic valve was replaced. The postoperative course was uneventful and he was discharged from the hospital 36 days post operatively.

4.
Japanese Journal of Cardiovascular Surgery ; : 180-184, 2005.
Article in Japanese | WPRIM | ID: wpr-367070

ABSTRACT

We performed entry closure for the chronic type B dissecting aneurysms by open surgical procedure or endovascular stent-graft placement. The purpose of this study is to evaluate the mid-term results of these patients with respect to mortality, morbidity, change of aneurysm diameter and outcome of the false lumen. From 1996 to 2003, entry closure was performed on 8 patients with chronic dissecting aortic aneurysm with an entry site in the descending aorta and visceral arteries that originated from the true lumen. The study population consisted of 4 men and 4 women with a mean age of 63.8±10.9 years. One patient had a DeBakey type III a and 7 patients had a DeBakey type III b dissecting aneurysm. Five patients underwent surgical entry closure and 3 patients underwent endovascular stent-graft placement. The mean follow-up period was 40±29 months. No operative mortalities, complications of paraplegia or visceral ischemia occurred. A leak was identified in 3 patients, 1 patient underwent an open repair with descending aortic replacement and 1 patient required additional stent-grafting. In the follow-up period, 1 patient died of cancer, but there were no dissection-related mortalities or re-operations for increase in size. With the exception of 1 case with a graft replacement, complete thrombosis of the thoracic aortic false lumen was achieved in 6 cases. There were no significant differences in the pre- and postoperative aortic diameter. Overall, complete thrombosis of the thoracic aortic false lumen was achieved with a high rate of success without a dissection-related mortality. Long-term follow-up, however, is necessary because a reduction in size did not occur in some cases.

5.
Japanese Journal of Cardiovascular Surgery ; : 299-301, 2004.
Article in Japanese | WPRIM | ID: wpr-366992

ABSTRACT

A 63-year-old woman was admitted to our hospital for combined valvular disease with tricuspid valve stenosis. Aortic and mitral valves were replaced with artificial valves and tricuspid valve were replaced with a biological valve. We chose artificial valves for the aortic and mitral valves because the patient was younger than 70, while a biological valve was used for the tricuspid valve to avoid possible thromboembolism. The postoperative course was excellent. We propose that it is better to use a biological valve for the tricuspid valve, even if artificial valves are used in other sites.

6.
Japanese Journal of Cardiovascular Surgery ; : 77-80, 2004.
Article in Japanese | WPRIM | ID: wpr-366949

ABSTRACT

Although the pressure gradient (PG) and the effective orifice area (EOA) have been used as indices of prosthetic valve function, these values show correctly neither energy loss, nor increased workload. This study aimed to evaluate the prosthetic valve function using echocardiography and PG, EOA and energy loss index, a new index advocated by Garcia et al. These were calculated for 40 patients with aortic prosthetic valve replacement by SJM valve (19HP, 6 cases; 21mm, 16 cases; 23mm, 14 cases; 25mm, 4 cases). Preoperative and postoperative echocardiographic measurements and their variations were analyzed and compared according to the size of implanted valve. In the comparison before and after aortic valve replacement, left ventricular mass (383±151g vs 288±113g, <i>p</i><0.01), SV1+RV5 on ECG (5.07±1.73mV vs 3.83±1.5mV, <i>p</i><0.01), and diastolic left ventricular posterior wall thickness (14.4±3.7mm vs 12.9±2.8mm, <i>p</i><0.05) decreased significantly after the operation. However, there was no significant difference according to the size of the prosthetic valve in these reduction rates caluculated by (preoperative value-postoperative value)/preoperative value. Small size prosthetic valves were used for patients with small diameter of left ventricular outflow tract (LVOT) (19HP, 18±2mm; 21mm, 21±2mm; 23mm, 23±4mm; 25mm, 27±3mm; <i>p</i><0.01) and small body surface area (19HP, 1.5±0.2m<sup>2</sup>; 21mm, 1.5±0.2m<sup>2</sup>; 23mm, 1.7±0.1m<sup>2</sup>; 25mm, 1.8±0.1m<sup>2</sup>; <i>p</i><0.01) in our study. There was a signifcant difference in EOA (19HP, 1.2±0.4cm<sup>2</sup>; 21mm, 1.9±0.7cm<sup>2</sup>; 23mm, 2.2±0.9cm<sup>2</sup>; 25mm, 3.5±1.1cm<sup>2</sup>; <i>p</i><0.01), but not in ELI (19HP, 1.01±0.41cm<sup>2</sup>/m<sup>2</sup>; 21mm, 1.87±1.03cm<sup>2</sup>/m<sup>2</sup>; 23mm, 1.83±1.09cm<sup>2</sup>/m<sup>2</sup>; 25mm, 3.08±1.21cm<sup>2</sup>/m<sup>2</sup>; <i>p</i>=0.055) according to the size of the prosthetic valve. Small size prosthetic valves had small EOA, but showed satisfactory valve function in decreasing left ventricular hypertrophy and reducing LVM and ELI of small size was similar to that of large size.

7.
Japanese Journal of Cardiovascular Surgery ; : 30-33, 2004.
Article in Japanese | WPRIM | ID: wpr-366923

ABSTRACT

The total arch replacement protocol using the open-style stent-graft placement is frequently performed for type A aortic dissection to obtain complete closure of entry sites. However the open-style stent-graft placement must be carefully planned when the entry site is in the descending aorta and extends beyond the level of the tracheal bifurcation, because spinal cord ischemia can be caused due to occlusion of lower thoracic intercostal arteries. We report an alternative to total arch replacement for type A aortic dissection with entry in the ascending aorta and aneurysmal re-entry in the descending aorta, beyond the level of the tracheal bifurcation. We inserted a guide-wire from the dissected area of the aortic arch towards the normal region beyond the re-entry in the descending aorta, with confirmation by direct ultrasonography and already incised half, introduced a graft into the descending aorta using the wire as a guide and performed anastomosis at the level of the transverse aortotomy in the inclusion method. This operation has the advantage of preventing spinal cord ischemia because the re-entry site in the descending aorta is confirmed by direct ultrasonography and the distal anastomosis does not reach the lower thoracic intercostal arteries. In this method, by which the prosthesis is introduced through the descending aorta and anastomosed in the inclusion method, is not needed troublesome treatment in the descending aorta and less invasive than conventional single-stage total arch replacement and applicable with the great safe for aortic dissection that had shown difficulty in application of open-style stent-graft placement.

8.
Japanese Journal of Cardiovascular Surgery ; : 61-64, 2002.
Article in Japanese | WPRIM | ID: wpr-366732

ABSTRACT

A 30-year-old man with a fever, cough, and dyspnea, was admitted to our hospital. A ruptured aneurysm of the Valsalva sinus (Konno classification, type I) was diagnosed associated with infective endocarditis of the aortic valve accompanied by aortic regurgitation (AR, grade II), and a ventricular septal defect (VSD, subarterial type). The operation was performed as follows: the removal of the aortic and pulmonary valves involved with endocarditis, the resection of the right aneurysm of the Valsalva sinus, and the myectomy of the fragile tissue of the right ventricle around the VSD. As a result, the large deficit region with the VSD and the resected right Valsalva sinus was patched with double sheets of equine pericardium. Aortic valve replacement (a prosthetic valve, ATS 18 AP) was anastomozed to the closed patch with the aid of the sheet as a part of the aortic valvular ring, and pulmonary valve replacement (a prosthetic valve, ATS 23 A) was done to the native pulmonary valvular site. During the 13 months after the surgery, under strict control of warfarin administration, the patient's clinical outcome has been favorable without infection and congestive heart failure. This case had AR accompanied with the subarterial type VSD, and aneurysmal formation of the Valsalva sinus and its rupture, and also revealed progressive infective endocarditis of the aortic and pulmonary valves, which resulted in severe cardiac failure. Early and appropriate surgical treatment for the ruptured aneurysm of the Valsalva sinus is required for a better prognosis prior to prevent exacerbation leading to infective endocarditis and critical heart failure.

9.
Japanese Journal of Cardiovascular Surgery ; : 55-57, 2002.
Article in Japanese | WPRIM | ID: wpr-366730

ABSTRACT

A 52-year-old woman who had been treated for miliary pulmonary tuber culosis complained of left flank pain. Abdominal aortic angiography revealed a saccular type aneurysm in the supra-renal abdominal aorta. We resected the aneurysm and reconstructed the aorta by arificial graft patch under partial extracorporeal circulation. The left renal artery was reconstructed by an artificial graft. During the operation, the superior mesenteric artery and the bilateral renal arteries were perfused by blood from the extracorporeal circuit. On pathological examination, it was shown that the aneurysm was caused by tuberculosis.

10.
Japanese Journal of Cardiovascular Surgery ; : 276-278, 2000.
Article in Japanese | WPRIM | ID: wpr-366595

ABSTRACT

A 79-year-old man underwent aortic valve replacement by xenografts for active infective endocarditis with aortic regurgitation. Two months later, he developed congestive heart failure and uncontrolled infective endocarditis. The second operation was performed 3 months later, with an aortic valve translocation procedure because of aortic regurgitation due to aortic root abscess and prosthetic valve endocarditis. Six months after the second operation, the saphenous vein graft (SVG) to the left coronary artery (LAD) revealed a severe stenotic lesion at the proximal site. The stenotic vein graft fed almost the entire left coronary circulation. The third operation was performed via left thoracotomy, under hypothermic circulatory arrest with cardiopulmonary bypass. A new radial artery (RA) graft was anastomosed between the descending thoracic artery and the old SVG for LAD. The patient recovered without any major complications and postoperative angiography showed that the new RA graft was patent.

11.
Japanese Journal of Cardiovascular Surgery ; : 264-267, 2000.
Article in Japanese | WPRIM | ID: wpr-366592

ABSTRACT

There are few reports on the long term efficacy of surgery for endocardial cushion defect (ECD) in elderly patients. We report a case with a successful course after ECD operation. A 70-year-old man was admitted with incomplete ECD, grade III mitral and tricuspid regurgitation, pulmonary hypertension and atrial fibrillation. The operative procedures included direct closure of the mitral cleft, pericardial patch closure for the ostium primum defect, direct closure of the tricuspid cleft and tricuspid annuloplasty. Pulmonary hypertension was improved after the operation, and he was discharged on the 41st day after the operation. Now, 3 years and 6 months after the operation, he has maintained an improved quality of life (QOL) with an uneventful postoperative course. The present report may suggest one solution for the long term effective treatment by operation for elderly patients who suffer from ECD, especially to achieve better QOL.

12.
Japanese Journal of Cardiovascular Surgery ; : 17-20, 2000.
Article in Japanese | WPRIM | ID: wpr-366540

ABSTRACT

DeBakey IIIb aortic dissection associated with thoracic aneurysm was successfully operated upon in a 59-year-old man. The patient had sudden onset of severe back pain and pain in the left lower extremity and dissection associated with thoracic aneurysm was diagnosed. During the operation, we used partial cardiopulmonary bypass support with cannulation of the pulmonary and femoral artery. The entry of the dissection was in a true aneurysm of the descending aorta, and it was replaced with a 22mm Hemashield prosthetic graft. Aortic dissection, with entry in the true aneurysm is rare and is of high risk for rupture.

13.
Japanese Journal of Cardiovascular Surgery ; : 243-246, 1999.
Article in Japanese | WPRIM | ID: wpr-366496

ABSTRACT

Renal function, hemolysis and hematologic parameters after transfusion using a cell-separation (CS) device were retrospectively evaluated during abdominal aortic aneurysm repair. Fifty-eight patients were divided into two groups, that is, the CS group (<i>n</i>=39) who received autologous retransfusion using the CS device and the non-CS group (<i>n</i>=19) who were operated before 1989, when we started to use CS device in our operating theater. Hematologic parameters and levels of GOT, GPT, LDH, BUN and creatinine were assessed before and 1, 2, 3, 4 and 7 days after the operation. Mean transfused homologous blood was 1.3±1.8 units in the CS groups and 4.9±3.1 units in the non-CS group (<i>p</i><0.05). Peak levels of LDH and GPT were significantly higher in the CS group than the non-CS group (<i>p</i><0.05) after the operation (GOT, CS group: 60.4±29.1IU/<i>l</i> vs non-CS group: 34.8±12.3IU/<i>l</i>, LDH, CS group: 643±324IU/<i>l</i> vs non-CS group: 446±108IU/l). There was no significant difference in the levels of BUN and creatinine levels between the two groups. Hemoglobin levels decreased gradually after the operation in CS group patients who did not receive a homologous blood transfusion. These data suggested that mild hemolysis occurred after retransfusion of autologous blood, but that the hemolysis due to the CS device had no effect on the renal function of the patients.

14.
Japanese Journal of Cardiovascular Surgery ; : 170-174, 1995.
Article in Japanese | WPRIM | ID: wpr-366123

ABSTRACT

We evaluated the efficacy of evoked spinal potential (ESP) monitoring during thoracoabdominal aortic replacement to prevent intra-operative spinal ischemia. Nine patients underwent intraoperative ESP monitoring. The ESP was unchanged in 5 patients and decreased in 4 patients. However, ESP recovered in 2 of them by the following techniques: (1) perfusion of intercostal arteries, (2) elevation of distal bypass perfusion pressure, (3) slight hypothermia. Postoperative paraplegia occurred only 1 patient of the 2 whose ESP was not restored. The sensitivity and specificity of the efficacy of ESP monitoring were 100% and 87.5%, respectively. We concluded that ESP is the most useful monitoring for prevention of operative spinal ischemia during thoracoabdominal aortic replacement.

SELECTION OF CITATIONS
SEARCH DETAIL