Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J. pediatr. (Rio J.) ; 95(5): 519-530, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1040353

ABSTRACT

Abstract Objective: To identify, using a systematic review and meta-analysis of observational studies, which risk factors are significantly associated with neonatal mortality in Brazil, and to build a comprehensive national analysis on neonatal mortality. Sources: This review included observational studies on neonatal mortality, performed between 2000 and 2018 in Brazilian cities. The MEDLINE, Elsevier, Cochrane, LILACS, SciELO, and OpenGrey databases were used. For the qualitative analysis, the Newcastle-Ottawa Scale was used. For the quantitative analysis, the natural logarithms of the risk measures and their confidence intervals were used, as well as the DerSimonian and Laird method as a random effects model, and the Mantel-Haenszel model for heterogeneity estimation. A confidence level of 95% was considered. Summary of findings: The qualitative analysis resulted in six studies of low and four studies of intermediate-low bias risk. The following exposure factors were significant: absence of partner, maternal age ≥35 years, male gender, multiple gestation, inadequate and absent prenatal care, presence of complications during pregnancy, congenital malformation in the assessed pregnancy, Apgar < 7 at the fifth minute, low and very low birth weight, gestational age ≤ 37 weeks, and caesarean delivery. Conclusion: The most significant risk factors presented in this study are modifiable, allowing aiming at a real reduction in neonatal deaths, which remain high in the country.


Resumo: Objetivo: Identificar, através de uma revisão sistemática e da metanálise de estudos observacionais, quais fatores de risco associam-se significativamente com a mortalidade neonatal no Brasil e construir uma análise nacional abrangente sobre a mortalidade neonatal. Fontes: Foram avaliados os estudos observacionais sobre mortalidade neonatal realizados entre 2000 e 2018 em cidades brasileiras. Usaram-se as bases MEDLINE, Elsevier, Cochrane, LILACS, SciELO e OpenGrey. Para a análise qualitativa, foi usada a Escala Newcastle-Ottawa. Para a análise quantitativa, foram utilizados os logaritmos naturais das medidas de risco e de seus intervalos de confiança, o método de DerSimonian e Laird como modelo de efeitos aleatórios e o modelo de Mantel-Haenszel para estimativa da heterogeneidade. Considerou-se nível de confiança de 95%. Resumo dos achados: A análise qualitativa resultou em seis estudos de baixo e quatro estudos de intermediário-baixo risco de viés. Foram significativos os seguintes fatores de exposição: ausência de companheiro, idade materna ≥ 35 anos, sexo masculino, gestação múltipla, pré-natal inadequado e ausente, presença de intercorrências durante a gestação, de malformação congênita na gestação em estudo, Apgar < 7 no quinto minuto, baixo e muito baixo peso ao nascer, idade gestacional ≤ 37 semanas e parto cesariano. Conclusão: Os fatores de risco mais significativos apresentados neste estudo são modificáveis, o que possibilita almejar uma redução real das mortes neonatais, que ainda permanecem elevadas no país.


Subject(s)
Humans , Female , Pregnancy , Infant , Infant Mortality , Pregnancy Complications , Socioeconomic Factors , Brazil/epidemiology , Infant, Low Birth Weight , Infant, Premature , Risk Factors , Risk Assessment , Observational Studies as Topic
3.
Revista Brasileira de Hipertensão ; 26(1): 13-16, 20190310.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1378337

ABSTRACT

A hipertensão arterial sistêmica (HAS) é uma doença multifatorial caracterizada por níveis elevados e sustentados de pressão arterial (PA). Vários são os fatores de risco implicados em sua expressão clínica, dentre eles: herança genética, idade, gênero, etnia, excesso de peso, ingestão excessiva de sal e de álcool, sedentarismo, entre outras. Nesta revisão são abordadas as modificações no estilo de vida (MEV) como fatores associados não apenas à prevenção, mas ao próprio tratamento de uma moléstia muito prevalente na população geral, de grande impacto socioeconômico e responsável por significativa morbimortalidade cardiovascular


Systemic arterial hypertension (SAH) is a multifactorial disease characterized by elevated and sustained blood pressure (BP) levels. There are several risk factors involved in its clinical expression, among them: genetic inheritance, age, gender, ethnicity, excess weight, excessive intake of salt and alcohol, sedentary lifestyle, among others. In this review, lifestyle modifications are addressed as factors associated not only with prevention, but also with the treatment of a very prevalent disease in the general population, with a high socioeconomic impact and responsible for significant cardiovascular morbidity and mortality.

4.
Rev. Col. Bras. Cir ; 46(6): e20192269, 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1057180

ABSTRACT

RESUMO Convencionalmente, a associação de anestésicos locais com vasoconstritores é evitada em extremidades pelo risco de isquemia. Entretanto, estudos recentes sugerem haver segurança no uso de vasoconstritor em extremidades. Procuramos, assim, avaliar a efetividade e segurança do uso de vasoconstritores combinados com anestésicos locais no bloqueio de nervos digitais em comparação ao uso de anestésicos plenos, através de uma revisão sistemática com metanálise de ensaios clínicos randomizados. Pesquisamos, até maio de 2019, nas bases de dados MEDLINE, LILACS, SciELO, ScienceDirect, Scopus, ClinicalTrials.gov e literatura cinzenta, sem restrições de data ou idioma, os descritores: bloqueio digital, vasoconstritor e isquemia. Foram incluídos ensaios clínicos randomizados nos quais houve a utilização de anestésicos locais associados ou não a vasoconstritores em bloqueios digitais. Nas variáveis primárias foram analisadas a ocorrência de complicações isquêmicas e a duração da anestesia, e nas variáveis secundárias foram observadas necessidade de reaplicação anestésica, de controle de sangramento e latência. Dez estudos foram incluídos nesta revisão. Não foi observada a ocorrência de isquemia, independente do uso ou não de vasoconstritores. O uso de vasoconstritores na concentração de 1:100.000 ou menor esteve associado a maior duração da anestesia (P<0,00001), menor necessidade de reaplicação anestésica (P=0,02), menor necessidade de controle de sangramento (P=0,00006) e menor latência (P<0,00001). Pudemos concluir que uso de vasoconstritores associados a anestésicos locais no bloqueio digital mostrou-se uma técnica segura e efetiva.


ABSTRACT Conventionally, the association of local anesthetics with vasoconstrictors is avoided at extremities due to the risk of ischemia. However, recent studies suggest that there is safety in the use of vasoconstrictors at extremities. Thus, we sought to evaluate the effectiveness and safety of vasoconstrictor use combined with local anesthetics in digital nerve block compared to the use of anesthetics without vasoconstrictors, through a systematic review with meta-analysis of randomized clinical trials. Until May 2019 we searched MEDLINE, LILACS, SciELO, ScienceDirect, Scopus, ClinicalTrials.gov, and gray literature databases, without date or language restrictions. The keywords were the following: digital block, vasoconstrictor, and ischemia. We included randomized clinical trials in which there was the use of local anesthetics with associated or not with vasoconstrictors in digital blocks. In the primary variables, the occurrence of ischemic complications and the duration of anesthesia were analysed; in the secondary variables, the need for anesthetic reapplication, bleeding control, and latency were observed. Ten studies were included in this review. The occurrence of ischemia was not observed, regardless of the use of vasoconstrictors or not. The use of vasoconstrictors at a concentration of 1:100,000 or less was associated with longer anesthesia duration (P<0.00001), lower need for anesthetic reapplication (P=0.02), lower need for bleeding control (P=0.00006), and lower latency (P<0.00001). We could conclude that the use of vasoconstrictors associated with local anesthetics in digital block proved to be a safe and effective technique.


Subject(s)
Humans , Vasoconstrictor Agents/administration & dosage , Anesthetics, Local/administration & dosage , Nerve Block/methods , Vasoconstrictor Agents/adverse effects , Anesthetics, Local/adverse effects , Nerve Block/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL