Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Year range
1.
Article in English | WPRIM | ID: wpr-1044826

ABSTRACT

Objective@#This study aimed to determine the predictive performance of non-contrast CT (NCCT) signs for hemorrhagic growth after intracerebral hemorrhage (ICH) when stratified by onset-to-imaging time (OIT). @*Materials and Methods@#1488 supratentorial ICH within 6 h of onset were consecutively recruited from six centers between January 2018 and August 2022. NCCT signs were classified according to density (hypodensities, swirl sign, black hole sign, blend sign, fluid level, and heterogeneous density) and shape (island sign, satellite sign, and irregular shape) features. Multivariable logistic regression was used to evaluate the association between NCCT signs and three types of hemorrhagic growth: hematoma expansion (HE), intraventricular hemorrhage growth (IVHG), and revised HE (RHE). The performance of the NCCT signs was evaluated using the positive predictive value (PPV) stratified by OIT. @*Results@#Multivariable analysis showed that hypodensities were an independent predictor of HE (adjusted odds ratio [95% confidence interval] of 7.99 [4.87–13.40]), IVHG (3.64 [2.15–6.24]), and RHE (7.90 [4.93–12.90]). Similarly, OIT (for a 1-h increase) was an independent inverse predictor of HE (0.59 [0.52–0.66]), IVHG (0.72 [0.64–0.81]), and RHE (0.61 [0.54– 0.67]). Blend and island signs were independently associated with HE and RHE (10.60 [7.36–15.30] and 10.10 [7.10–14.60], respectively, for the blend sign and 2.75 [1.64–4.67] and 2.62 [1.60–4.30], respectively, for the island sign). Hypodensities demonstrated low PPVs of 0.41 (110/269) or lower for IVHG when stratified by OIT. When OIT was ≤ 2 h, the PPVs of hypodensities, blend sign, and island sign for RHE were 0.80 (215/269), 0.90 (142/157), and 0.83 (103/124), respectively. @*Conclusion@#Hypodensities, blend sign, and island sign were the best NCCT predictors of RHE when OIT was ≤ 2 h. NCCT signs may assist in earlier recognition of the risk of hemorrhagic growth and guide early intervention to prevent neurological deterioration resulting from hemorrhagic growth.

2.
China Pharmacist ; (12): 156-158, 2017.
Article in Chinese | WPRIM | ID: wpr-507990

ABSTRACT

Objective:To establish a method for the determination of three optical isomers in bortezomib. Methods: An HPLC method was used with a ChiralPAKAY-H normal phase chiral column (250 mm × 4. 6 mm, 5 μm). The mobile phase was n-hexane-ethanol-methanol-trifluoroaceticacid (90 ∶7. 5∶2. 5∶0. 1) and the flow rate was 0. 8 ml·min-1 . The detection wavelength was set at 270 nm. The column temperature was 40℃ and the injection volume was 5 μl. Results: The separation of bortezomib from the three optical isomers was more than 2. 0. The linear range of the three optical isomers was 0. 6-20μg·ml-1(r≥0. 999 7). The average re-covery was 104. 1%, 105. 5% and 92. 0% with RSD of 2. 3%, 2. 4% and 2. 7%, respectively (n=9). The limit of quantification and detection limit was 3 ng and 1 ng, respectively. Conclusion:The method is rapid and accurate, and can be used for the determi-nation of optical isomers in bortezomib.

3.
China Pharmacist ; (12): 1959-1960, 2016.
Article in Chinese | WPRIM | ID: wpr-503315

ABSTRACT

Objective:To establish an HPLC method to determine the content of carfilzomib for injection. Methods:The chroma-tographic column was a Waters symmetry C18(250 mm ×4.6 mm, 5 μm)column, the sample solvent was methanol, the mobile phase was 0. 05% trifluoroacetic acid-acetonitrile(57 ∶43) at a flow rate of 1. 0 ml · min-1 , the detection wavelength was 210 nm, the col-umn temperature was 25℃ and the injection volume was 10 ml. Results:The linear range of carfilzomib was 120-600 μg·ml-1 ( r=0. 999 7). The average recovery was 100. 4%( RSD=0. 24%,n=9). Conclusion:The method is rapid and effective, which can be used for the content determination of carfilzomib for injection.

4.
China Pharmacist ; (12): 582-584, 2016.
Article in Chinese | WPRIM | ID: wpr-487351

ABSTRACT

Objective: To establish a determination method for the enantiomer in safinamide mesilate. Methods: A Chiralpak ASH (250 mm ×4. 6 mm, 5 μm) column was used with the mobile phase of n-hexane-ethanol-diethylamine (75 ∶ 25 ∶ 0. 1). The flow rate was 1. 0 ml·min-1 . The wavelength was set at 225 nm. The column temperature was 35℃. Results: The resolution of safinamide mesilate and the enantiomer was above 2. 0. The linear range of them was 1. 007-2 517. 500 μg·ml-1 and 0. 909-2273. 200 μg·ml-1 ,respectively(r = 0. 999 0). The average recovery of the enantionmer was 104. 9% with RSD of 2. 3% (n = 9). Conclusion: The method is accurate and rapid, and suitable for the determination of the enantiomer in safinamide mesilate.

5.
China Pharmacist ; (12): 1094-1095,1101, 2016.
Article in Chinese | WPRIM | ID: wpr-604346

ABSTRACT

Objective:To establish an HPLC method for the determination of optical isomers in carfilzomib .Methods:The sample was separated on a Chiralpak OX-H column.The mobile phase consisted of n-hexane∶isopropanol∶alcohol (89 ∶5 ∶6, v/v/v) with a flow rat of 1.0 ml· min-1 .The detection wavelength was 220 nm.Results:The linear rang of enantiomer , diastereomer Ⅰand di-astereomer Ⅱwas 0.54-2.14 μg· ml -1,0.11-1.80 μg· ml-1 and 0.11-1.81 μg· ml-1(r≥0.998), respectively.The lower limit of quantification was 0.07-0.27 μg· ml-1 .The recoveries of optical isomers were within the range of 99.6%-100.9% with RSD of 1.13%-1.59%(n=9).Conclusion:The method is sensitive, simple, fast, accurate and specific, and suitable for the study of opti-cal isomers in carfilzomib .

6.
China Pharmacist ; (12): 1629-1631, 2014.
Article in Chinese | WPRIM | ID: wpr-475808

ABSTRACT

Objective:To establish a method for the determination of enantiomer in rivaroxaban by HPLC. Methods:A Chiralpak IA column (250 mm × 4. 6 mm, 5 μm) was used with the mobile phase of 100% methanol. The flow rate was 1. 0 ml·min-1 . The detection wavelength was set at 250 nm and the column temperature was 40℃. Results:The resolution of rivaroxaban and the enanti-omer was above 2. 0. The linear range of them was 0. 5-1 000. 00 μg·ml-1(r=0. 999 9). The detection limit of the enantiomer was 0. 17ng and the average recovery was 102. 9% with RSD of 1. 54%(n=6). Conclusion:The method is accurate and rapid, and suit-able for the determination of the enantiomer in rivaroxaban.

7.
China Pharmacist ; (12): 188-190, 2014.
Article in Chinese | WPRIM | ID: wpr-452838

ABSTRACT

Objective:To establish the determination method for four lurasidone hydrochloride enantiomers by HPLC. Methods:Lurasidone hydrochloride enantiomers were separated on a CHIRALPAK AD-H column (250 mm × 4. 6 mm, 5μm). The mobile phase consisted of hexane-ethanol-diethylamine ( 90∶10∶0. 1) at a flow rate of 1. 0 ml·min-1 and the column temperature was at 40℃. The detection wavelength was 230nm. Results:The resolution of lurasidone hydrochloride enantiomers was above 2. 0. The linear calibra-tion curves were obtained over the range of 5-120 μg· ml-1 for all the enantiomers (r=0. 999 9). The recovery was above 99. 0%with RSD below 0. 5%. The detection limits were 5ng. Conclusion:The method is simple, accurate and rapid, and suitable for the de-termination and quality control.

8.
China Pharmacy ; (12)1991.
Article in Chinese | WPRIM | ID: wpr-524220

ABSTRACT

OBJECTIVE:To determine the dissolution of ibuprofen and paracetamol in soft capsules.METHODS:Phos?phate buffer(pH=7.2)was taken as a solvent with the rotating speed set at75/min,and sample taken time was45minutes.The dissolution degree of ibuprofen and paracetamol in soft capsules were determined by a RP-HPLC method.The chro?matographic column was CN column;the mobile phase was phosphate buffer(pH=6.6)-methanol(60∶40)with a flow rate of1.0ml/min,the detection wavelength at223nm and the column temperature at30℃.RESULTS:The linear calibration curves were obtained with a range of0.17~100.14?g/ml for paracetamol(r=0.9999,n=9)and0.21~124.86?g/ml for ibuprofen(r=0.9999,n=9)respectively;the average recoveries of the two compounds were99.62%(RSD=0.36%)and99.79%(RSD=0.49%)respectively.CONCLUSION:The determination method is simple,rapid,accurate and reliable,which can be applied to measure the dissolution content of ibuprofen and paracetamol in soft capsules satisfactorily.

SELECTION OF CITATIONS
SEARCH DETAIL