ABSTRACT
Objective To evaluate the diagnostic value of 99Tcm-MIBI SPECT/CT imaging and 99Tcm-MIBI planar imaging semi-quantitative analysis in primary hyperparathyroidism (PHPT).Methods A total of 89 patients were enrolled into this retrospective study.The diagnostic efficiencies of 99Tcm-MIBI SPECT/CT were compared with 9Tcm-MIBI planar scintigraphy and ultrasound,while the surgical pathology and the clinical follow-up results were considered as the standard.The region of interest extraction technique was used to measure and calculate the tumour to normal tissue ratios (T/NT) in the early and delayed phase of the planar scintigraphy,and the correlation between pathological type,PTH concentration and T/NT ratios was analyzed.Results The sensitivities and specificities of SPECT/CT,99Tcm-MIBI planar scintigraphy and ultrasound were 98.08%,88.46%,78.43%;82.93%,82.93%,58.82% respectively.There were statistically significant correlations between the pathological type and PTH concentration,early phase T/NT and delayed phase T/NT,and the correlation coefficients r were 0.741,0.642 and 0.729,respectively.Conclusions 99Tcm-MIBI SPECT/CT imaging is an effective method for diagnosis of PHPT,with higher clinical application value than 99Tcm-MIBI planar scintigraphy and ultrasound.The semi-quantitative analysis of 99Tcm-MIBI planar scintigraphy provides a new method for the differential diagnosis of PHPT.
ABSTRACT
Objective To evaluate the additional role of 99mTc-MIBI SPECT-CT imaging before parathyroidectomy (PTX) for secondary hyperparathyroidism (SHPT) patients.Methods A total of 359 SHPT patients from the First Affiliated Hospital of Nanjing Medical University were enrolled in the study from April 2011 to January 2016.Patients were divided into two groups according to the difference of 99mTc-MIBI imaging techniques preoperatively.Patients in group A had dual-phase 99mTc-sestamibi parathyroid scintigraphy performed only.Patients in group B had SPECT-CT parathyroid scintigraphy added in the early phase.With the parathyroid glands confirmed by pathology after operation being the referencc,scnsitivity,specificity,consistency and surgical success rates of the patients in two groups were compared.Results 359 patients (166 men and 193 women) were enrolled,among which 339 on hemodialysis and 20 on peritoneal dialysis.The average age of those patients was (45.90± 11.20) years and median dialysis age was 84 (60.0,120.0) months.Total detection sensitivity,specificity,consistency in group A (169 patients) were 65.54%,56.52%,65.24% and in group B (190 patients) were 73.84%,84.62%,74.21% respectively.Total sensitivity and consistency were higher in group B than those in group A (P < 0.01),while no difference in total specificity was observed between two groups (P=0.055).In group A,detection sensitivity of parathyroid glands were 47.56%,77.44%,57.14% and 79.88% in right upper gland (RU),right lower gland (RL),left upper gland (LU) and left lower gland (LL) respectively.Consistency in group A were 48.52%,77.51%,56.21% and 78.70% respectively.In group B,sensitivity were 58.33%,83.78%,69.78% and 82.89% in RU,RL,LU and LL respectively.Consistency in group B were 59.47%,84.21%,70.53% and 82.63% respectively.Sensitivity and consistency of upper glands were lower than lower glands in both groups (P < 0.01).When SPECT-CT was added,sensitivity and consistency of upper glands for both sides were higher in group B than those in group A,while no difference of surgical success rates was found between two groups (87.57% vs 92.63%,P=0.107).Conclusion 99mTc-MIBI SPECT-CT can be combined with anatomic image effectively and increase the sensitivity and consistency of total and upper parathyroid glands.It can also make the accurate location of the lesions,which improves the efficiency of the operation.
ABSTRACT
BACKGROUND AND OBJECTIVES: Accurate preoperative localization of abnormal parathyroid gland is essential for successful parathyroidectomy. The aim of this study was to evaluate the accuracy of a localization test for hyperparathyroidism including ultrasonography (US), computed tomography (CT) and 99mTc-sestamibi scan. SUBJECTS AND METHOD: We studied 47 patients with hyperparathyroidism who underwent parathyroidectomy from January 2003 through December 2010, retrospectively. 99mTc-sestamibi scan, US and CT were carried out as a preoperative localization test and their accuracy were analyzed according to the size, location and pathology of parathyroid lesions. RESULTS: The accuracy of 99mTc-sestamibi scan, US and CT were 93%, 77% and 65%, respectively. The accuracy of 99mTc-sestamibi scan and CT combined was 94% and US and CT 73%. The accuracy of combination of US and 99mTc-sestamibi scan was 96%, which was not different depending on size, location and pathology of parathyroid lesions. CONCLUSION: The combination of 99mTc-sestamibi scan and US is the most effective method for preoperative detection and the localization of hyperparathyroidism.
Subject(s)
Humans , Hyperparathyroidism , Parathyroid Glands , Parathyroidectomy , Retrospective Studies , Technetium Tc 99m SestamibiABSTRACT
Myocardial ischemia may occur during an exercise session in cardiac rehabilitation programs. However, it has not been established whether it is elicited when exercise prescription is based on heart rate corresponding to the anaerobic threshold as measured by cardiopulmonary exercise testing. Our objective was to determine the incidence of myocardial ischemia in cardiac rehabilitation programs according to myocardial perfusion SPECT in exercise programs based on the anaerobic threshold. Thirty-nine patients (35 men and 4 women) diagnosed with coronary artery disease by coronary angiography and stress technetium-99m-sestamibi gated SPECT associated with a baseline cardiopulmonary exercise test were assessed. Ages ranged from 45 to 75 years. A second cardiopulmonary exercise test determined training intensity at the anaerobic threshold. Repeat gated-SPECT was obtained after a third cardiopulmonary exercise test at the prescribed workload and heart rate. Myocardial perfusion images were analyzed using a score system of 6.4 at rest, 13.9 at peak stress, and 10.7 during the prescribed exercise (P < 0.05). The presence of myocardial ischemia during exercise was defined as a difference ≥2 between the summed stress score and summed rest score. Accordingly, 25 (64 percent) patients were classified as ischemic and 14 (36 percent) as nonischemic. MIBI-SPECT showed myocardial ischemia during exercise within the anaerobic threshold. The 64 percent prevalence of ischemia observed in the study should not be looked on as representative of the whole population of patients undergoing exercise programs. Changes in patient care and exercise programs were implemented as a result of our finding of ischemia during the prescribed exercise.
Subject(s)
Aged , Female , Humans , Male , Middle Aged , Anaerobic Threshold/physiology , Exercise Test/adverse effects , Heart Rate/physiology , Myocardial Ischemia/etiology , Coronary Angiography , Coronary Artery Disease/rehabilitation , Myocardial Ischemia/physiopathology , Myocardial Ischemia , Radiopharmaceuticals , Risk Factors , Tomography, Emission-Computed, Single-PhotonABSTRACT
Pre-operative localization of abnormal parathyroid tissue helps in deciding whether surgery begins with a neck or mediastinal exploration. In this study we aimed to evaluate the usefulness of parathyroid scintigraphy in pre-operative localization of parathyroid adenomas and treatment. From February 2006 to October 2008, patients with signs and symptoms of hyperparathyroidism were recruited to join the study. The study group consisted of 3 males and 8 females. All subjects had a pre-operative parathyroid scintigraphy with Tc99m Sestamibi followed by parathyroidectomy. Ten patients had a positive scintigraphic finding which correlated to the actual location of the adenoma determined during the operation. Almost all patients (10 out of 11) underwent minimally invasive parathyroidectomy (MIP) while only one patient underwent bilateral neck dissection. The average incision length was 3.73 + 0.65 cm. Only one patient had an adverse event (transient hypocalcemia and bleeding necessitating a drain) which resolved later. The average hospital stay was 2.5 + 0.7 days. Parathyroid Tc99m-sestamibi scan is a reliable, non-invasive, and cost effective imaging modality in pre-operative localization of parathyroid adenomas for first time parathyroidectomy. This can help and guide surgeons to perform focused parathyroid surgery with minimal incision, successful localization, less complications, and shorter hospital stays.
Subject(s)
Humans , Male , Female , Adenoma , Hyperparathyroidism , Hypocalcemia , Length of Stay , Neck Dissection , Parathyroid Glands , Parathyroid Neoplasms , Parathyroidectomy , Surgeons , Technetium Tc 99m Sestamibi , Endocrine Gland NeoplasmsABSTRACT
A osteomalácia oncogênica hipofosfatêmica (OOH) é uma síndrome paraneoplásica induzida por tumor, de tecidos mole ou ósseo. Apresenta-se com dor e fraturas, acompanhada de hipofosfatemia, hiperfosfatúria e concentrações plasmáticas de 1,25(OH)2D3 inapropriadamente normais/diminuídas. Após a remoção do tumor, a completa resolução das anormalidades clínicas e bioquímicas é sua maior característica. Uma mulher de 44 anos de idade é descrita no caso com dificuldade para caminhar por causa de dores nos membros inferiores, fraqueza muscular generalizada e hipofosfatemia com relativa hiperfosfatúria. A cintilografia de corpo total com sestamibi-99mTc mostrou acúmulo do radiofármaco no terço superior de coxa esquerda onde pequeno tumor foi detectado no exame pelo ultra-som. Com a retirada do tumor, um lipoma, os sintomas melhoraram após um mês, com recuperação completa ao redor do quarto mês. Neste caso, a cintilografia de corpo inteiro com sestamibi-99mTc foi decisiva na localização do tumor causador da osteomalácia oncogênica.
Oncogenic osteomalacia is a paraneoplastic syndrome usually induced by bone or soft tissue tumors. It is presented by the development of pain and fractures with hypophosphatemia, hyperphosphaturia, and inappropriate normal/low plasma 1,25(OH)2D3 concentration. After the removal of the tumor the complete resolution of all biochemical and clinical abnormalities is the main characteristic. A case of a 44-year-old female with difficulty in walking due to leg pain and generalized muscle weakness and hypophosphatemia, with relative hyperphosphaturia, is described. A whole-body 99mTc-sestamibi scintigraphy showed accumulation in the left thigh region, and a small tumor was detected by ultrasound examination. By removal of the tumor, a lipoma, the symptoms improved significantly after a month, with complete recovery by the fourth month. In this case, 99mTc-sestamibi scintigraphy was useful in identifying the location of the tumor, which caused oncogenic osteomalacia.
Subject(s)
Adult , Female , Humans , Osteomalacia , Peripheral Nervous System Neoplasms , Radiopharmaceuticals , Hypophosphatemia/pathology , Mesoderm/pathologyABSTRACT
PURPOSE: 99mTc-sestamibi (MIBI) and 99mTc-tetrofosmin have been used as substrates for P-glycoprotein (Pgp) and multidrug resistance associated protein (MRP), which are closely associated with multidrug resistance of the tumors. To understand different handling of radiotracers in cancer cell lines expressing Pgp and MRP, we compared cellular uptakes of 99mTc-MIBI and 99mTc-tetrofosmin. The effects of cyclosporin A (CsA), well-known multidrug resistant reversing agent, on the uptake of both tracers were also compared. MATERIALS AND METHODS: HCT15/CL02 human colorectal cancer cells for Pgp expressing cells, and human non-small cell lung cancer A549 cells for MRP expressing cells, were used for in vitro and in vivo studies. RT-PCR, western blot analysis and immunohistochemistry were used for detection of Pgp and MRP. MDR-reversal effect with CsA was evaluated at different drug concentrations after incubation with MIBI or tetrofosmin. Radioactivities of supernatant and pellet were measured with gamma well counter. Tumoral uptake of the tracers were measured from tumor bearing nude mice treated with or without CsA. RESULTS: RT-PCR, western blot analysis of the cells and immunochemical staining revealed selective expression of Pgp and MRP for HCT15/CL02 and A549 cells, respectively. There were no significant difference in cellular uptakes of both tracers in HCT15/CL02 cells, but MIBI uptake was slightly higher than that of tetrofosmin in A549 cells. Co-incubation with CsA resulted in a increase in cellular uptakes of MIBI and tetrofosmin. Uptake of MIBI or tetrofosmin in HCT15/CL02 cells was increased by 10- and 2.4-fold, and by 7.5 and 6.3-fold in A549 cells, respectively. Percentage increase of MIBI was higher than that of tetrofosmin with CsA for both cells (p< 0.05). In vivo biodistribution study showed that MIBI (114% at 10 min, 257% at 60 min, 396% at 240 min) and tetrofosmin uptake (110% at 10 min, 205% at 60 min, 410% at 240 min) were progressively increased by the time, up to 240 min with CsA. But increases in tumoral uptake were not significantly different between MIBI and tetrofosmin for both tumors. CONCLUSION: MIBI seems to be a better tracer than tetrofosmin for evaluating MDR reversal effect of the modulators in vitro, but these differences were not evident in vivo tumoral uptake. Both MIBI and tetrofosmin seem to be suitable tracers for imaging Pgp- and MRP-mediated drug resistance in tumors.
Subject(s)
Animals , Humans , Mice , Blotting, Western , Carcinoma, Non-Small-Cell Lung , Cell Line , Colorectal Neoplasms , Cyclosporine , Drug Resistance , Drug Resistance, Multiple , Immunohistochemistry , Mice, Nude , Multidrug Resistance-Associated Proteins , ATP Binding Cassette Transporter, Subfamily B, Member 1 , Radioactivity , Technetium Tc 99m SestamibiABSTRACT
BACKGROUND: Cardiovascular disease is known as an important predictor of mortality, not only in patients undergoing dialysis treatment but also in those who are starting dialysis treatment. In addition, it is well known that cardiovascular morbidity is about twice higher in diabetic patients. In this study, MIBI and echocardiography were performed in patients starting dialysis treatment, and a comparison of these findings between diabetic (DM) and non-diabetic (Non-DM) patients was done. METHODS: Among the patients diagnosed as end- stage renal disease (ESRD) and started dialysis treatment at Severance Hospital, 77 patients underwent MIBI and echocardiography when they were clinically stable within 4 weeks after the initiation of dialysis. Clinical characteristics, laboratory findings, MIBI and echocardiographic findings of the 77 patients were analyzed. RESULTS: The mean age of the patients was 58.4+/-10.8 years with sex ratio of 1.1: 1. Of the 77 patients, 52 were DM and 25 were Non-DM. There were 30 patients (39.0%) with abnormal findings on MIBI scan, 26 with reVersible and 4 with fixed defects, and 69 patients (89.6%) with left ventricular hypertrophy (LVH) on echocardiography. DM group showed higher prevalence of myocardial perfusion defect than Non-DM group (48.1% vs. 20.0%, p< 0.05). There were no differences in the prevalence of LVH (92.3% vs. 84.0%) and in left ventricular ejection fraction (LVEF) (56.1+/-13.1% vs. 57.5+/-11.8%) between DM and Non-DM groups. LVEF was significantly lower in patients with abnormal findings on MIBI scan than those with normal MIBI finding. CONCLUSION: The majority of ESRD patients starting dialysis treatment accompanied LVH and myocardial perfusion defect was present in many cases especially in diabetic patients. Therefore, early evaluation and treatment of ischemic heart disease are mandatory in diabetic patients starting dialysis treatment for ESRD.
Subject(s)
Humans , Cardiovascular Diseases , Diabetes Mellitus , Dialysis , Echocardiography , Hypertrophy, Left Ventricular , Kidney Failure, Chronic , Mortality , Myocardial Ischemia , Perfusion , Prevalence , Sex Ratio , Stroke Volume , Technetium Tc 99m Sestamibi , Tomography, Emission-Computed, Single-PhotonABSTRACT
PURPOSE: Cellular uptakes of 99mTc-sestamibi (MIBI) and 99mTc-tetrofosmin into cancer cell lines expressing multidrug resistance (MDR) were investigated and compared. The effects of verapamil and cyclosporin A, well-known multidrug resistant reversing agents, on cellular uptakes of both tracers were also compared. MATERIALS AND METHODS: Doxorubicin-resistant HCT15/CL02 human colorectal cell and doxorubicin-resistant K562 (Adr) and vincristine-resistant K562 (Vcr) human leukemic cells were studied. RT-PCR analysis was used for the detection of mdr1 mRNA expression. MDR-reversal effects with verapamil and cyclosporine A were evaluated at different drug concentrations after incubation with MIBI and tetrofosmin for 1, 15, 30, 45 and 60 min, using single-cell suspensions at 1x10 (6) cells/ml incubated at 37 degrees C. Radioactivity in supernatants and pellets were measured with gamma well counter. RESULTS: The cellular uptakes of MIBI and tetrofosmin in K562 (Adr) and K562 (Vcr) were lower than those of parental K562 cell. In HCT15/CL02 cells and K562 (Adr) cells, there were no significant difference in cellular uptakes of both tracers, but cellular uptake of MIBI was higher than that of tetrofosmin in K562 (Vcr) cells. Coincubation with verapamil resulted in a increase in cellular uptakes of MIBI and tetrofosmin. Verapamil increased cellular uptakes of MIBI and tetrofosmin by HCT15/CL02 cell by 11.9- and 6.8-fold, by K562 (Adr) cell by 14.3- and 8-fold and by K562 (Vcr) cell by 7- and 5.7-fold in maximum, respectively. Cyclosporin A increased cellular uptakes of MIBI and tetrofosmin by HCT15/CL02 cell by 10- and 2.4-fold, by K562 (Adr) cell by 44- and 13-fold and by K562 (Vcr) cell by 18.8- and 11.8-fold in maximum, respectively. CONCLUSION: Taking together, MIBI and tetrofosmin are considered as suitable radiopharmaceuticals for detecting multidrug resistance. However, MIBI seems to be a better tracer than tetrofosmin for evaluating MDR reversal effect of the modulators. Since cellular uptakes of both tracers might differ in different cell types, further experiments regarding differences in cellular uptakes between cell types should be explored.
Subject(s)
Humans , Cell Line , Cyclosporine , Drug Resistance, Multiple , Parents , Radioactivity , Radiopharmaceuticals , RNA, Messenger , Suspensions , Technetium Tc 99m Sestamibi , VerapamilABSTRACT
BACKGROUND: Lung-to-heart uptake ratio (LHR) in (201) Tl-chloride myocardial perfusion scan is believed to be a reliable marker for left ventricular (LV) dysfunction, but the clinical value of LHR is controversial for 99mTc-MIBI imaging. Furthermore, most of results suggesting lung uptake of 99mTc-MIBI as a potential marker for LV dysfunction used immediate post-stress images, instead of routine images acquired 1 hour after tracer injection. The goal of our study was to investigate whether LHR evaluated with routine gated 99mTc-MIBI imaging can reflect the degree of perfusion defect or left ventricular performance. SUBJECTS AND METHODS: 241 patients underwent exercise 99mTc-MIBI myocardial SPECT were classified into normal myocardial perfusion (NP, n=135) and abnormal myocardial perfusion (AP, n=106) group according to the presence of perfusion defect. LHR was calculated from anterior projection image taken at 1-hour after injection. Two regions of interest (ROIs) were placed on left lung above LV and on myocardium showing the highest radioactivity. Subjects were classified by left ventricular ejection fraction (LVEF), as Gr-I: > 50%, Gr-II: 36-50%, Gr-III: 13, LHR was compared among these groups. RESULTS: In NP group (n=135), LHR, were higher in men than women (men: 0.311+/-0.03, women: 0.296+/-0.03, p or = 0.38, women> or = 0.37) of the LHR of the subject with normal perfusion. Increased LHR were observed more frequently in subjects with lower LVEF (Gr-I: 11.1%, Gr-II: 27.0%, Gr-III: 36.4%, p< 0.05) and higher SSS (Gr-A: 14.0%, Gr-B: 6.7%, Gr-C: 18.2%, Gr-D: 40.7%, p< 0.05). CONCLUSIONS: LHRs obtained from routine 99mTc-MIBI gated SPECT images were weakly correlated with LVEF and perfusion defect. Although significant overlaps were observed between normal and abnormal perfusion group, LHRs could be used as an indirect marker of severe perfusion defect or reduced left ventricular function.
Subject(s)
Female , Humans , Male , Lung , Myocardium , Perfusion , Radioactivity , Stroke Volume , Technetium Tc 99m Sestamibi , Tomography, Emission-Computed, Single-Photon , Ventricular Function, LeftABSTRACT
BACKGROUND AND OBJECTIVES: Reverse redistribution pattern (RRP), that is defined as the worsening of the perfusion defect at rest image, can be observed in 99mTC-sestamibi (methoxy isobutyl isonitrile) myocardial scan with standard stress-rest protocol. This study was prepared to evaluate the prevalence and clinical characteristics of RRP in stress 99mTc-sestamibi myocardial scan. MATERIALS AND METHODS: We retrospectively reviewed 1304 images of 99mTC-sestamibi myocardial perfusion scan performed between January 1995 and June 1997, and scintigraphic findings were compared with clinical and angiographic data. RESULTS: The prevalence of RRP was 5.2%(68 of 1,304). RRP was noted in 6.0% (41 of 679) of the adenosine study and 4.3% (27 of 625) of the exercise study. The mean coronary artery stenosis at RRP territory was 51.5+/-38.9%. However, normal coronary artery at RRP territory was noted in 45.8% (11 of 24). There was no significant differences in luminal narrowing of coronary arteries, TIMI flow grade and LV wall motion between the patient with RRP positive and RRP negative at the infarct related artery territory. CONCLUSION: Reverse redistribution pattern on 99mTC-sestamibi myocardial SPECT does not seem to indicate the presence of significant coronary artery disease or patency of the infarct related arteries in the patients with acute MI.
Subject(s)
Humans , Adenosine , Arteries , Coronary Artery Disease , Coronary Stenosis , Coronary Vessels , Perfusion , Phenobarbital , Prevalence , Retrospective Studies , Technetium Tc 99m Sestamibi , Tomography, Emission-Computed, Single-PhotonABSTRACT
PURPOSE: Tc-99m-tetrofosmin(TF) is a recently proposed myocardial imaging agent which has similar biokinetic characteristics to Tc-99m-sestamibi(MIBI). The aim of this study was to compare TF and MIBI myocardial perfusion SPECTs in detecting coronary artery disease. MATERIALS AND METHODS: One hundred and sixty patients(l0l males, 59 females, mean age 57+/-9 yr) who had undergone both myocardial perfusion SPECT (M- SPECT) and coronary angiography within 1 month were studied. M-SPECT was performed using TF in 115 patients and MIBI in 45 patients. Stress-rest one day protocol was used in all patients A coronary stenosis was considered significant when the luminal diameter > or =50% was compromised. The chi square test was used to compare, differences in sensitivity and specificity between the two groups. RESULTS: There was no difference in age and diseased coronary artery branches between the two groups. There were more male patients in TF group: Male-to-female ratios of TF and MIBI groups were 78:37 and 23:22, respectively (p<0.05). The overall sensitivity of TF study was 92% and specificity 36%. The overall, sensitivity and specificity of MIBI study were 93% and 30% respectively. There was no difference between TF and MIBI groups in identifying individual diseased coronary artery branches. CONCLUSION: One day stress-rest myocardial SPECT using either TF or MIBI was comparable and was a very sensitive test in detecting coronary artery disease.