Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Rev. ADM ; 80(4): 190-196, jul.-ago. 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1525858

ABSTRACT

Introducción: la adaptación marginal e interna de nuestras restauraciones fabricadas por fundición sistemas de fresado y sinterización láser es uno de los factores clínicos más importantes para el éxito de las prótesis fijas, previniendo el riesgo de microfiltración y enfermedad periodontal. Objetivo: evaluar la adaptación marginal e interna de cofias metálicas en aleación Cr-Co confeccionadas por técnicas convencionales, CAD/ CAM de fresado y sinterizado por láser. Material y métodos: estudio de tipo experimental, comparativo e in vitro. Se imprimió un modelo maestro en Cr-Co, proveniente del escaneo de un premolar preparado para corona completa, sobre el cual se diseñaron 30 cofias divididas en tres grupos: el primero que corresponde al grupo cofias fundidas fresadas en disco de cera A (A = 10), el segundo grupo cofias fresadas en disco de metal presinterizado B (B = 10) y el tercer grupo cofias impresas por sinterización láser C (C = 10). Se empleó la réplica de silicona, colocando silicona al interior de cada cofia, sobre el modelo maestro, simulando al cemento, mediante una máquina de ensayo universal se realizó una compresión de 50 N. Luego de retirar cada cofia se rellenaron con silicona pesada de adición, obteniendo una réplica de silicona. Se efectuaron dos cortes transversales en sentido vestíbulolingual y mesiodistal. Se observó el espesor de silicona VPS (vinil poliéter silicona) mediante un estereomicroscopio (Nikon SMZ745T), obteniendo valores en micrómetros. Para el análisis estadístico se utilizó el software SPSS 25 con el fin de realizar la prueba de normalidad y ANOVA de dos vías bajo un nivel de confianza del 95%. Resultados: el menor gap lo obtuvo el grupo de fresadas, seguido de las impresas y por último las fundidas por métodos convencionales. ANOVA de dos vías reveló diferencias estadísticamente significativas entre los tres grupos (p < 0.0001). Conclusiones: se encontró que el gap varía con cada método de fabricación, la técnica convencional de fundido mostró un mayor gap, ninguna excediendo el rango clínicamente aceptable (AU)


Introduction: the marginal and internal adaptation of our restorations manufactured by casting, milling systems and laser sintering is one of the most important clinical factors for the success of fixed prostheses, preventing the risk of microleakage and periodontal disease. Objective: evaluate the marginal and internal adaptation of metal copings in Cr-Co alloy made by conventional techniques, CAD/CAM milling and laser sintering. Material and methods: an experimental, comparative and in vitro study, a Cr-Co master model was printed from the scan of a premolar prepared for a full crown. An experimental, comparative and in vitro study, a Cr-Co master model was printed from the scan of a premolar prepared for a full crown, on which 30 caps divided into three groups were designed; the first group corresponds to the cast copings milled on a wax disc A (A = 10), the second group milled copings on a presintered metal disc B (B = 10) and the third group printed by laser sintering copings C (C = 10). The silicone replica was used, placing silicone inside each coping, on the master model, simulating cement, using a universal testing machine, a 50 N compression was performed. After removing each coping, they were filled with heavy addition silicone, obtaining a silicone replica. Two cross-sections were made in the buccolingual and mesiodistal direction., observing the thickness of the VPS (vinyl polyeter silicone) silicone using a stereomicroscope (Nikon SMZ745T), obtaining values in micrometers. For the statistical analysis, the SPSS 25 software was used in order to perform the normality and two-way ANOVA tests under a 95% confidence level. Results: the smallest gap was obtained by the milled group, followed by the printed ones and finally those cast by conventional methods. Two-way ANOVA revealed statistically significant differences between the three groups (p < 0.0001). Conclusions: the gap was found to vary with each fabrication method, the conventional casting technique showed a larger gap, none exceeding the clinically acceptable range (AU)


Subject(s)
Chromium Alloys , Computer-Aided Design , Dental Marginal Adaptation , Crowns , Lasers , In Vitro Techniques , Analysis of Variance
2.
Rev. Asoc. Odontol. Argent ; 111(1): 2-2, feb. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1431217

ABSTRACT

Resumen Objetivos: a) Comparar la fuerza de ruptura (FR), adaptación marginal externa (AME) y angulación intracuspídea (AI) entre carillas oclusales confeccionadas con composite, cerámica híbrida y feldespática obtenidas con sistemas CADCAM fijadas con distintos medios cementantes y b) evaluar si el medio cementante, la AME y la AI influyen en la FR. Materiales y métodos: 50 premolares conformaron 6 grupos de acuerdo a la combinación de los materiales Cp, omposite Paradigm MZ100 (P), Cerámica híbrida VitaEnamic (VE), Cerámica feldespática Vitablocks Mark II (F) con los cementos Variolink N curado dual (VN) o resina compuesta Z100 calentada (RC): Grupo 1 (n=10) P-VN, Grupo 2 (n=10) P-RC, Grupo 3 (n=10) VE-RC, Grupo 4 (n=10) VE-VN, Grupo 5 (n=5) F-VN, Grupo 6 (n=5) F-RC. Los dientes preparados y acondicionados recibieron carillas confeccionadas utilizando el Sistema Cerec 3. Luego, fueron sometidas a fuerzas compresivas en una máquina de ensayos universal, aplicando una carga con una velocidad de desplazamiento igual a 0,5 mm/ minuto hasta el cese por fractura catastrófica. Previo a realizar los ensayos se midió la AME en sus cuatro caras y la AI. Resultados: Se obtuvieron valores de mayor FR para los Grupos 1 y 2, que se diferenciaron significativamente de los otros 4 grupos (p<0,05). El medio cementante no influyó sobre la FR (p>0,05). Hubo diferencias con relación a los materiales y la AME favoreciendo al Grupo 1 (p<0,05). Conclusiones: Las carillas oclusales confeccionadas en composite con sistemas CAD-CAM (Paradigm MZ100) necesitaron mayor fuerza para provocar su ruptura y registraron menores desadaptaciones.


Abstract Aims: a)To compare the breaking strength (BS), external marginal adaptation (EMA) and intracuspid angulation (ID) between occlusal veneers made with composite, hybrid ceramic and feldspathic obtained with CAD-CAM systems fixed with different cementing medium and b) to evaluate the effect that the cement, the EMA and ID have on the BS. Materials and methods: 50 premolars formed 6 groups according to the combination of the Composite Paradigm MZ100 (P), VitaEnamic hybrid ceramic (VE), Vitablocks Mark II feldspathic ceramic (F) with the dual-cured Variolink N (VN) or Z100 Heated Composite Resin (RC): Group 1 (n10) P-VN, Group 2 (n10) P-RC, Group 3 (n10) VERC, Group 4 (n10) VE-VN, Group 5 (n5) F-VN, Group 6 (n5) F-RC. The teeth received a preparation and were conditioned, subsequently, they received occlusal veneers using the Cerec 3 System. They were then subjected to compressive forces in a Testing Machine, applying a load with a speed of movement equal to 0.5 mm/ minute until it stopped due to catastrophic fracture. Before carrying out the tests, the EAM was registered in four faces and the ID was measured. Results: Higher BS were obtained for Groups 1 and 2, which differed significantly from Groups 3,4,5 and 6 (p<0.05). The cementing medium did not influence the BS (p>0.05). There were differences in relation to the materials and the EMA favoring Group 1 (p<0.05). Conclusions: The occlusal veneers made in composite with CAD-CAM systems (Paradigm MZ100) required greater force to cause their rupture and registered less misadaptations.

3.
Odontol. sanmarquina (Impr.) ; 24(2): 5-11, abr.-jun. 2021.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1178061

ABSTRACT

Objetivo. El objetivo de este estudio fue evaluar la adaptación marginal de coronas de disilicato de litio obtenidas mediante técnicas de escaneo (CAD/CAM), antes y des- pués de la cristalización, a través de análisis in vitro con microscopía confocal (MC). Métodos. Fueron confeccionadas 16 réplicas en poliuretano a partir de la pieza 1.4, de modelo typodont, tallada para corona total. Las réplicas fueron divididas en dos gru- pos, de acuerdo a la técnica de escaneo: Técnica Indirecta (Grupo IND, n=08), donde modelos de yeso fueron escaneados con escáner de laboratorio (inEos X5, Sirona Den- tal Systems) y Técnica Directa (Grupo DIR, n=08), donde modelos typodont fueron escaneados con escáner intraoral (CEREC BlueCam, Sirona Dental Systems). A seguir, se fresaron (inLab MC XL, Sirona Dental Systems) coronas en disilicato de litio (IPS e.max CAD, Ivoclar Vivadent) y se adaptaron a las réplicas. Se evaluó la adaptación marginal con análisis de MC en dos momentos, antes y después de la cristalización del disilicato de litio. Los datos fueron analizados con la prueba de Mann-Whitney, t de Student y Wilcoxon (α= 0,05). Resultados. Hubo una diferencia estadísticamente significativa en la adaptación marginal horizontal entre los grupos IND y DIR después de la cristalización (p=0,05). En el grupo IND, la comparación de la adaptación mar- ginal vertical antes y después de la cristalización mostró una diferencia estadísticamente significativa (p=0,038). Conclusiones. Las coronas de disilicato de litio obtenidas me- diante escaneo directo (CAD/CAM) presentaron menor desajuste marginal vertical. La etapa de cristalización afectó la adaptación marginal de las coronas.


Objective. This study aimed to evaluate lithium disilicate marginal adaption on crowns by scanning techniques (CAD/CAM), before and after crystallization, through confocal microscopy (CM) in vitro analysis. Methods. Sixteen polyurethane replicas were per- formed from tooth 1.4, of a typodont model, prepared for a full crown. The replicas were divided into two groups, according to the scanning technique: Indirect Technique (Group IND, n=08), where dental stone models were scanned with a laboratory scanner (inEos X5, Sirona Dental Systems) and Direct Technique (Group DIR, n=08), where typodont models were scanned with an intraoral scanner (CEREC BlueCam, Sirona Dental Systems). Then, the lithium disilicate crowns (IPS e.max CAD, Ivoclar Vivadent) were milled (inLab MC XL, Sirona Dental Systems) and adapted to the replicas. Margin- al adaptation was evaluated with CM analysis before and after lithium disilicate crystalli- zation. Data were analyzed with the Mann-Whitney, t test, and Wilconxon test (α=0.05). Results. There was a statistically significant difference in horizontal marginal adaptation between IND and DIR groups after crystallization (p=0.05). In IND group, the compar- ison of vertical marginal adaptation before and after crystallization showed a statistically significant difference (p=0.038). Conclusions. Lithium disilicate crowns obtained by direct scanning technique (CAD/CAD) showed less vertical marginal maladjustment. The crystallization stage affected the crown's marginal adaptation.

4.
Rev. Ateneo Argent. Odontol ; 64(1): 77-82, 2021.
Article in Spanish | LILACS | ID: biblio-1252984

ABSTRACT

A pesar de los avances e innovaciones de los materiales dentales, la microfiltración marginal y la contracción durante la polimerización continúan siendo una de las causas principales del fracaso de los tratamientos en odontología restauradora. Un sellado marginal correcto será posible cuando las fuerzas de adhesión superen las fuerzas generadas por la contracción de polimerización y las fuerzas generadas por los cambios dimensionales térmicos posteriores a la polimerización, por lo que investigaciones previas demostraron que estas limitaciones pueden ser superadas con el uso de resinas Bulk Fill como material de relleno de cavidades extensas y profundas de dientes posteriores. Estas resinas. de relleno masivo, están recibiendo atención, principalmente porque se pueden colocar, a diferencia de las resinas convencionales, en incrementos de 4 mm sin afectar la contracción de la polimerización, la adaptación de la cavidad o el grado de conversión. El objetivo de la presente revisión bibliográfica es describir la contracción de polimerización y la consecuente filtración marginal que sufren las resinas compuestas para el sector posterior Bulk Fill con base de datos de la literatura (AU)


Despite advances and innovations in dental materials, marginal microfiltration and shrinkage during polymerization continue to be one of the main causes of treatment failure in Restorative Dentistry. A correct marginal seal will be possible when the adhesion forces exceed the forces generated by polymerization contraction and the forces generated by post-polymerization thermal dimensional changes, for which previous research has shown that these limitations can be overcome with the use of Bulk Fill resins as filling material for large and deep posterior tooth cavities, these massive filling resins are receiving attention mainly because they can be placed, unlike conventional resins, in 4 mm increments without affecting polymerization shrinkage. , cavity adaptation or degree of conversion. The objective of the present bibliographic review is to describe the polymerization contraction and consequent marginal filtration suffered by Composite Resins for the Bulk Fill posterior sector with a literature database (AU)


Subject(s)
Humans , Dental Marginal Adaptation , Composite Resins , Dental Leakage , Polymerization , Materials Testing , Dental Cavity Preparation , Dental Restoration, Permanent/instrumentation
5.
Int. j. odontostomatol. (Print) ; 14(1): 60-66, mar. 2020. tab, graf
Article in English | LILACS | ID: biblio-1056502

ABSTRACT

ABSTRACT: The objective of the study was to evaluate marginal adaptation of Class II mesial-occlusal-distal (MOD) restorations before and after thermo-mechanical loading and volumetric shrinkage of the bulk-fill vs conventional composite resin. For marginal adaptation assessment, 24 Class II MOD cavities with cervical margins extending 1.0 mm below (distal) and 1.0 mm beyond (mesial) the cement-enamel junction were prepared in extracted human molars. The teeth were filled as follows: Group A - bulk-fill with SureFil SDR flow (first increment, 4 mm; second increment, 2 mm); Group B - bulk-fill with SureFil SDR flow as a base (first increment, 4 mm) and covered with the conventional nanohybrid composite Esthet-X HD (second increment, 2 mm); and Group C - incrementally filled with Esthet-X HD. Marginal adaptation was evaluated by scanning electron microscopy before and after thermomechanical loading (240,000 loading cycles and simultaneous 600 thermal cycles). To evaluate volumetric polymerization shrinkage, a semi-spherical mold was filled with the tested composites and placed in an AccuVol device after light curing. Both before and after loading, marginal adaptation in cervical dentin was superior (p < 0.05) for Groups A and B compared with Group C. In cervical enamel, Group B showed better marginal adaptation than Group C, and Group A presented intermediary results, between Groups B and C. Furthermore, bulk-fill flow resulted in greater shrinkage than Esthet-X HD. A significant improvement of marginal adaptation was observed when bulkfill flow was used instead of conventional composite resin both before and after thermomechanical loading. However, the bulk-fill flow presented higher volumetric polymerization shrinkage than the conventional composite.


RESUMEN: El objetivo de este trabajo consistió en evaluar la adaptación marginal de las restauraciones mesiales-oclusales-distales (MOD) de Clase II antes y después de la carga termo-mecánica y la contracción volumétrica de la carga compuesta de resina "bulk-fill" en comparación con resina convencional. Para la evaluación de adaptación, se prepararon 24 cavidades MOD de Clase II en molares humanos extraídos, los que se restauraron de la siguiente manera: Grupo A: restaurado con resina fluida Bulk-Fill SureFilSDR (primer incremento, 4 mm; segundo incremento, 2 mm); Grupo B: restaurado con resina fluida Bulk-Fill SureFil SDR (primer incremento, 4 mm) y cubierto con resina compuesta nanohíbrida Esthet-X HD (segundo incremento, 2 mm); y Grupo C - rellenado incrementalmente con Esthet-X HD. La adaptación marginal se evaluó mediante microscopía electrónica de barrido antes y después de la carga termomecánica (240.000 ciclos de carga y 600 ciclos térmicos simultáneos). Para evaluar la contracción volumétrica de la polimerización, se llenó un molde semiesférico con los compuestos probados y se colocó en un dispositivo AccuVol después del fotopolimerización. Tanto antes como después de la carga, la adaptación marginal en la dentina cervical fue superior (p <0,05) para los grupos A y B en comparación con el grupo C. En el esmalte cervical, el grupo B mostró una mejor adaptación marginal que el grupo C, y el grupo A presentó resultados intermedios, entre Grupos B y C. Se observó una mejora significativa de la adaptación marginal al utilizar la resina fluida Bulk-Fill en lugar de resina compuesta convencional tanto antes como después de la carga termomecánica. Sin embargo, la resina fluida 'Bulk-Fill' presentó una mayor contracción volumétrica de polimerización que el compuesto convencional.


Subject(s)
Humans , Dental Marginal Adaptation , Composite Resins , Dental Cavity Preparation/instrumentation , Dental Restoration, Permanent/methods , Malocclusion, Angle Class II , Stress, Mechanical , Ethics Committees , Dental Restoration Wear , Dental Cavity Preparation/standards , Polymerization
6.
Odontología (Ecuad.) ; 22(1): 66-81, 2020.
Article in Spanish, English, Portuguese | LILACS | ID: biblio-1050508

ABSTRACT

No se han establecido estándares para el tratamiento de cavidades cervicales no cariosas; un biomaterial adecuado permitirá buena adaptación y longevidad de la restauración. Objetivo: Determinar la microfiltración en cavidades clase V no cariosas restauradas con ionómero de vidrio y resina nanoparticulada. Materiales y métodos: Cavidades clase V realizadas en la superficie vestibular de 80 premolares sanos (1,5 mm de pro-fundidad x 3 mm de altura en sentido ocluso- gingival x 2 mm de ancho en sentido mesio-distal) se restauraron aleatoriamente con dos biomateriales (n = 40): 1) ionómero de vidrio y 2) resina de nano relleno. Después, los especímenes fueron aislados con barniz y sumergidos en azul de metileno por 24 horas. Posteriormente, las muestras se sometieron 500 ciclos de termociclado por 8 horas y 45 minutos con cambios térmicos de 37°, 72° y 75°C, cada ciclo con una duración de 17 segundos. Las muestras fueron lavadas con agua destilada y seccionadas longitudinalmente para determinar el grado de microfiltración utilizando un estereoscopio (Leica M60, Biosystems). Los datos categóricos se analizaron con el test Chi2 en SPSS 24®. Resultados: Se pudo apreciar que la filtración es significativamente menor en resina que con ionómeros de vidrio (p < 0,001). Sin embargo, ninguno de los materiales de restauración probados fue capaz de sellar los márgenes o las paredes de los dientes completamente. Conclusión: como resultado del presente experimento se determina que las restauraciones de clase V obturadas con resina de nano relleno presentan menor microfiltración marginal que las restauradas con ionómero de vidrio.


No standards have been established for the treatment of non-carious cervical cavities; a suitable biomaterial will allow good adaptation and longevity of the restoration. Objective: To determine microfiltration in non-car-ious class V cavities restored with glass ionomer and nanoparticulate resin. Materials and methods: Class V cavities made on the vestibular surface of 80 healthy premolars (1.5 mm deep x 3 mm high in the occlusion-gin-gival direction x 2 mm wide in the mesio-distal direction) were randomly restored with two biomaterials (n = 40): 1) glass ionomer and 2) nano-filled resin. Then, the specimens were isolated with varnish and immersed in methylene blue for 24 hours. Subsequently, the samples were subjected to 500 cycles of thermocycling for 8 hours and 45 minutes with thermal changes of 37°, 72° and 75° C, each cycle with a duration of 17 seconds. The samples were washed with distilled water and sectioned longitudinally to determine the degree of micro-filtration using a stereoscope (Leica M60 Biosystems). Categorical data were analyzed with the Chi2 test in SPSS 24®. Results: It was observed that filtration is significantly lower in resin than in those restored with glass ionomers (p < 0.001). However, none of the restoration materials tested were able to seal the margins or walls of the teeth completely. Conclusion: As a result of the present experiment, it is determined that class V resto-rations sealed with nano-filled resin have less marginal microfiltration than those restored with glass ionomer.


Ainda não foram estabelecidos padrões para o tratamento de cavidades cervicais não cariosas; um biomate-rial adequado permitirá boa adaptação e longevidade da restauração. Objetivo: Determinar a microfiltração em cavidades não cariosas da classe V restauradas com ionômero de vidro e resina nanoparticulada. Materi-ais e métodos: Cavidades de classe V feitas na superfície vestibular de 80 pré-molares saudáveis (1,5 mm de profundidade x 3 mm de altura na direção oclusão-gengival x 2 mm de largura na direção mesio-distal) foram restaurados aleatoriamente com dois biomateriais (n = 40): 1) ionômero de vidro e 2) resina nano-híbrida. Em seguida, as amostras foram isoladas com verniz e imersas em azul de metileno por 24 horas. Posteriormente, as amostras foram submetidas a 500 ciclos de termociclagem por 8 horas e 45 minutos com alterações tér-micas de 37°, 72° e 75° C, cada ciclo com duração de 17 segundos. As amostras foram lavadas com água destilada e seccionadas longitudinalmente para determinar o grau de microfiltração usando um estereoscópio (Leica M60, Biosystems). Os dados categóricos foram analisados com o teste Chi2 no SPSS 24®. Resul-tados: Observou-se que a filtração é significativamente menor na resina do que nos ionômeros de vidro (p <0,001). No entanto, nenhum dos materiais de restauração testados foram capazes de selar completamente as margens ou paredes dos dentes. Conclusão: como resultado do presente experimento, determina-se que restaurações de classe V seladas com resina nano-preenchida possuem menos microfiltração marginal do que aquelas restauradas com ionômero de vidro.


Subject(s)
Composite Resins , Dental Cavity Lining , Dental Leakage , Dental Marginal Adaptation , Dental Cementum
7.
Rev. estomatol. Hered ; 29(4): 253-266, oct.-dic 2019. ilus, tab
Article in Spanish | LILACS-Express | LILACS, BBO | ID: biblio-1144584

ABSTRACT

Las nuevas tecnologías digitalizadas han permitido migrar de la técnica de cera perdida colada por centrifugación (CPC) a la fabricación sustractiva por CAD/CAM como la técnica de fresado de bloque blando (SMB). Objetivo: El propósito de este estudio fue comparar las adaptaciones marginales e internas en cofias metálicas de Co-Cr sobre dos líneas de terminación: chamfer y bisel confeccionadas mediante dos técnicas: CPC y SMB. Material y Métodos: Se confeccionaron dos modelos maestros de Co-Cr con terminación chamfer y bisel, se formaron 4 grupos de estudio y se fabricaron 13 cofias por grupo. Para la evaluación de las adaptaciones marginal e interna se usó el método de la réplica en silicona, luego con un estéreo microscopio se evaluó las discrepancias marginales e internas. Resultados: Para la discrepancia marginal entre las dos técnicas, para la terminación bisel sólo se observó diferencias estadísticamente significativas (p<0,05) en los puntos A1 y A2 y en la terminación chamfer se observó diferencias estadísticamente significativas (p<0,05) en los puntos A1 y F1. En la adaptación interna comparando ambas técnicas en la terminación bisel se obtuvo diferencias estadísticamente significativas (p<0,05) en los puntos E1, E2, D1, C2 y D2. En la terminación chamfer los resultados mostraron diferencias estadísticamente significativas (p<0,05) en todos los puntos. Conclusiones: Las cofias que presentaron mejor adaptación marginal fueron las confeccionadas por SMB con la línea de terminación chamfer, en la línea de terminación bisel no se pudo concluir cuál de las dos técnicas es mejor en adaptación marginal. Las que presentaron mejor adaptación interna en ambas líneas de terminación, en la zona axial fueron las cofias realizadas mediante la técnica CPC y en la zona oclusal presentaron mejor adaptación interna el SMB.


The new digitized technologies have allowed to migrate from the technique of lost cast wax by centrifugation (CPC) to the subtractive manufacturing by CAD / CAM as the technique of soft-block milling (SMB). Objective: The purpose of this study was to compare the marginal and internal adaptations in metal Co-Cr copes on two termination lines: chamfer and bevel made by two techniques: CPC and SMB. Material and Methods: Two Co-Cr master models with chamfer and bevel termination were made, 4 study groups were formed and 13 copings were made per group. For the evaluation of the marginal and internal adaptations the replication method was used in silicone, then with a stereomicroscope the marginal and internal discrepancies were evaluated. Results: For the marginal discrepancy between the two techniques, only statistically significant differences were observed for the bevel termination (p <0.05) in points A1 and A2 and in the chamfer termination statistically significant differences were observed (p <0.05) in points A1 and F1. In the internal adaptation comparing both techniques in the bevel termination, statistically significant differences were obtained (p <0.05) in points E1, E2, D1, C2 y D2. And in the chamfer termination, the results showed statistically significant differences (p <0.05) in all the points. Conclusions: The copes that presented better marginal adaptation were those made by SMB with the chamfer termination line, in the bevel termination line it was not possible to conclude which of the two techniques is better in marginal adaptation. The ones that presented better internal adaptation in both lines of termination, in the axial zone were the copings made using the CPC technique and in the occlusal area the SMB had better internal adaptation.

8.
Rev. estomatol. Hered ; 29(1): 39-48, ene.-mar. 2019. ilus, tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1014044

ABSTRACT

Nuevas técnicas nos están permitiendo migrar de la técnica de cera perdida colado por centrifugado convencional (CPCC) a técnicas como la cera perdida colado por inducción (CPCI). Objetivos: Comparar la discrepancia marginal e interna de cofias unitarias de aleación Cobalto-Cromo (Co-Cr) sobre una línea de terminación chamfer, confeccionadas con dos técnicas: CPCC y CPCI, determinando cual técnica tuvo mejor adaptación marginal e interna. Material y Métodos: Se fabricaron13 cofias metálicas unitarias de aleación Co-Cr para cada técnica a evaluar. Se utilizó la réplica de silicona para evaluar las discrepancias marginales e internas, cada muestra fue seccionada en cruz en sentido vestíbulo-palatino y en sentido mesio-distal, luego con un estéreomicroscopio se evaluó la zona cervical, axial y oclusal. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk. Los análisis estadísticos fueron la prueba t de Student y U Mann-Whitney. La CPCI obtuvo una menor discrepancia marginal e interna en comparación con la CPC pero no se encontró diferencias estadísticamente significativas (p>0,05) entre ambas técnicas. Conclusiones: Aunque en la mayoría de los puntos de evaluación las cofias realizadas mediante la CPCI presento mejores valores de adaptación marginal e interna en comparación con la CPCC estos resultados sólo son valores descriptivos que no fueron concluyentes, ya que en la mayoría de los puntos evaluados no existió diferencia estadísticamente significativa (p>0,05). Observamos que la mayoría de los valores de ambas técnicas se encuentran dentro del rango clínicamente aceptable.


New techniques are allowing us to migrate from the technique of lost wax cast by conventional centrifugation (CPCC) to techniques such as lost wax cast by induction (CPCI). Objectives: To compare the marginal and internal discrepancy of cobalt-chromium (Co-Cr) alloy unit copes on a chamfer termination line, made with two techniques: CPCC and CPCI, determining which technique had better marginal and internal adaptation. Material and Methods: 13 Co-Cr alloy unit copings were fabricated for each technique to be evaluated. Silicon replication was used to evaluate the marginal and internal discrepancies. Each sample was cross-sectioned in the vestibular-palatine and mesio-distal directions, then the cervical, axial and occlusal zones were evaluated with a stereomicroscope. Results: 13 unitary Co-Cr alloy metal cops were manufactured for each technique to be evaluated. The silicone replica was used to evaluate the marginal and internal discrepancies, each sample was cross-sectioned in the vestibulo-palatal direction and in the mesio-distal sense, then with a stereomicroscope, the cervical, axial and occlusal areas were evaluated. Conclusions: The assumptions of normality were evaluated with the Shapiro-Wilk test. The statistical analyzes were Student s t test and U Mann-Whitney test. The CPCI obtained a lower marginal and internal discrepancy compared to the CPC, but no statistically significant differences were found (p >0.05) between both techniques. Conclusions: Although in most of the evaluation points the copings made by the CPCI presented better values of marginal and internal adaptation compared to the CPCC, these results are only descriptive values that were not conclusive, since in most of the evaluated points there was no statistically significant difference (p >0.05). We observed that most of the values of both techniques are within the clinically acceptable range.

9.
Odontología (Ecuad.) ; 21(2): 19-38, 2019.
Article in Spanish | LILACS | ID: biblio-1050031

ABSTRACT

Entre los requerimientos que debe cumplir una restauración provisional, destacan la adaptación marginal precisa y el sellado adecuado del agente cementante temporal. Objetivo: Comparar la adaptación marginal y resistencia a la tracción de coronas provisionales fabricadas con acrílico de termocurado y resina, cementadas con dos tipos de biomaterial. Me-todología: Estudio in vitro. 40 premolares superiores fueron tallados para recibir una corona completa que se confeccionó con dos tipos de biomaterial provisional (n=20): acrílico de termocurado Veracril® y resina Temp Basic® - CAD/CAM. Las coronas fueron cementadas con dos agentes cementantes temporales (Dycal® y TempBond NE®), se observó la adapta-ción marginal por medio de un estéreo microscopio; después, fueron sometidas a termociclado por 2.500 ciclos y luego se realizó una segunda observación y medición, finalmente se realizaron pruebas de tracción. Resultados: Mediante Kruskal Wallis se encontró diferencias significativas entre los grupos en ambos tiempos de estudio. Los grupos cementados con Dycal® presentaron mejor sellado marginal antes y después del termociclado y mayor resistencia a la tracción que los ce-mentados con TempBond NE® (p= <0,05). En todos los grupos la adaptación marginal fue menor después del termocicla-do (p= <0,05). Por medio del coeficiente de Pearson se determinó una correlación negativa (- 0.97) entre la desadaptación marginal y la resistencia a la tracción. Conclusiones: La desadaptación marginal tiene relación con el cemento utilizado, las coronas provisionales cementadas con Dycal® presentaron estadísticamente menor discrepancia marginal y mayores fuerzas de retención con relación al TempBond NE. El proceso de termociclado influyó en el aumento de la desadaptación marginal en todos los grupos. Cuando la desadaptación fue mayor disminuyó la resistencia a la tracción.


Among the requirements that must be carried out by a provisional restoration, the precise marginal adaptation and ade-quate sealing of the temporary cementing agent stand out. Objective: To compare the marginal adaptation and tensile strength of temporary crowns made of thermo-curing acrylic and resin, cemented with two types of biomaterial. Meth-odology: In vitro study. 40 upper premolars were carved to receive a complete crown that was made with two types of provisional biomaterial (n = 20): Veracril® thermosetting acrylic and Temp Basic® resin - CAD / CAM. The crowns were cemented with two temporary cementing agents (Dycal® and TempBond NE®), marginal adaptation was observed by means of a stereo microscope; then, they were subjected to thermocycling for 2,500 cycles and then a second observation and measurement was performed, finally tensile tests were performed. Results: Kruskal Wallis found significant differences between the groups in both study times. The groups cemented with Dycal® presented better marginal sealing before and after thermocycling and greater tensile strength than those cemented with TempBond NE® (p = <0.05). In all groups the marginal adaptation was lower after thermocycling (p = <0.05). By means of the Pearson coefficient, a negative correlation (- 0.97) was determined between marginal maladjustment and tensile strength. Conclusions: The marginal microleakage is related to the cement used, the provisional crowns cemented with Dycal® presented statistically lower marginal dis-crepancy and greater retention forces in relation to TempBond NE. The thermocycling process influenced the increase in marginal maladjustment in all groups. When the maladjustment was higher, the tensile strength decreased.


Entre os requisitos que uma restauração provisória deve atender, destacam-se a adaptação marginal precisa e o selamen-to adequado do agente de cimentação temporário. Objetivo: Comparar a adaptação marginal e resistência à tração de coroas temporárias de acrílico e resina de termopolimerização, cimentadas com dois tipos de biomateriais. Metodologia: Estudo in vitro. 40 pré-molares superiores foram preparados para receber uma coroa completa confeccionada com dois tipos de biomaterial provisório (n = 20): acrílico de termopolimerização Veracril® e resina Temp Basic® - CAD / CAM. As coroas foram cimentadas com dois agentes de cimentação temporários (Dycal® e TempBond NE®); a adaptação margi-nal foi observada por meio de estéreo microscópio; depois, foram submetidos a termociclagem por 2.500 ciclos térmicos e, em seguida, uma segunda observação e medição foi realizada; finalmente, testes de tração foram realizados. Resulta-dos: no teste Kruskal Wallis encontrou-se diferenças significativas entre os grupos nos dois tempos de estudo. Os grupos cimentados com Dycal® apresentaram melhor selamento marginal antes e depois da termociclagem e maior resistência à tração do que os cimentados com TempBond NE® (p = <0,05). Em todos os grupos, a adaptação marginal foi menor após da termociclagem (p = <0,05). Por meio do coeficiente de Pearson, foi determinada uma correlação negativa (- 0,97) entre discrepância marginal e resistência à tração. Conclusões: A perda da adaptação marginal está relacionada ao cimento utilizado, as coroas provisórias cimentadas com Dycal® apresentaram discrepância marginal menor estatisticamente significativa e maiores forças de retenção em relação ao TempBond® NE. O processo de termociclagem influenciou o au-mento da desadaptação marginal em todos os grupos. Quando a desadaptação foi maior, a resistência à tração diminuiu.


Subject(s)
Dental Marginal Adaptation , Dental Cements , Dental Restoration, Temporary , Tensile Strength , Biocompatible Materials , Crowns
10.
Odontología (Ecuad.) ; 21(2): 67-85, 2019.
Article in Spanish | LILACS | ID: biblio-1050208

ABSTRACT

Luego del procedimiento de cementación de incrustaciones de cerómero puede presentarse microfiltración en la inter-fase diente-restauración, el gap en la interfase puede ser influenciado por las características del agente cementante y el proceso de cementación. Objetivo: Evaluar la microfiltración en incrustaciones de cerómero tipo table top cementadas con tres diferentes cementos. Materiales y métodos: En 36 terceros molares divididos en 3 grupos (n= 12), se realizaron preparaciones estandarizadas tipo table top y se fabricaron incrustaciones con CERAMAGE® (SHOFU, Japón) que fueron cementadas con 3 biomateriales diferentes, Grupo A: cemento de autograbado RelyX® U200 (3M). Grupo B: cemento uni-versal RelyX Ultimate® (3M, USA). Grupo C: resina termo plastificada a 55oC Enamel Plus HRI® (Micerium). Cada muestra se sometió a termociclado (3300 ciclos) y se colocaron en una solución de azul de metileno durante 24 horas. Para el aná-lisis se realizó un corte longitudinal en la zona media en sentido meso-distal de las muestras y se evaluó la microfiltración marginal en la cara mesial y distal con la ayuda de un estéreo microscopio Olympus. Los resultados se almacenaron en una base de datos en Excel, posteriormente los valores experimentales se archivaron y fueron codificados utilizando el software BioEstat (Brasil). El análisis se realizó mediante la prueba no paramétrica de Kruskal Wallis, con una significancia del 95%. Resultados: la resina termo plastificada presentó los valores más bajos en el grado de microfiltración con una media de 0,4mm; con el cemento universal se obtuvo los valores más altos con una media de 1,33mm, que no fue signi-ficativa en relación al cemento de autograbado que tuvo una media de 0,88mm. Conclusiones: se logró determinar que en restauraciones tipo table top el grado de microfiltración fue menor cuando se cementaron con resina termo plastificada (p= < 0,05) con una diferencia estadísticamente significativa respecto a los otros cementos. No existió diferencia en la microfiltración entre los cementos de resina de autograbado en relación al cemento de resina universal.


After the process of cementation of cerometer encrustations, microfiltration can occur in the tooth-restoration interface, the gap in the interface can be influenced by the characteristics of the cementing agent and the cementation process. Objec-tive: To evaluate the microfiltration in inlays of ceramics type table top cemented with three different cements. Materials and methods: In 36 third molars divided into 3 groups (n = 12), standardized table top preparations were made and inlays made with CERAMAGE® (SHOFU, Japan) that were cemented with 3 different biomaterials, Group A: cement RelyX® U200 self-etch (3M). Group B: RelyX Ultimate® universal cement (3M, USA). Group C: thermoplastic resin at 55oC. Each sample was subjected to thermocycling (3300 cycles) and placed in a solution of methylene blue for 24 hours. For the analysis, a longitudinal cutting was made in the middle area in the meso-distal direction of the samples and the marginal microfiltration on the mesial and distal side was evaluated with the help of an Olympus stereo microscope. The results were stored in a database in Excel, then the experimental values were archived and coded using the BioEstat software (Brazil). The analysis was performed using the non-parametric Kruskal Wallis test, with a significance of 95%. Results: the thermoplastic resin had the lowest values in the degree of microfiltration with an average of 0.4mm; with the universal cement the highest val-ues were obtained with an average of 1.33mm, which was not significant in relation to the self-etched cement that had an average of 0.88mm. Conclusions: it was possible to determine that in table type restorations the degree of microfiltration was lower when they were cemented with thermoplasticized resin (p = <0.05) with a statistically significant difference with respect to the other cements. There was no difference in microfiltration between self-etched resin cements in relation to universal resin cement.


Após o processo de cimentação das incrustações de cerômero, pode ocorrer microfiltração na interface dente-restau-ração, o espaço na interface pode ser influenciado pelas características do agente cimentante e do processo de ci-mentação. Objetivo: Avaliar a microfiltração em incrustações tipo "table top" de cerómero cimentada com três cimentos diferentes. Materiais e métodos: Em 36 terceiros molares divididos em 3 grupos (n = 12), foram preparadas restaurações padronizadas tipo "table top", após, incrustações foram confeccionadas com CERAMAGE® (SHOFU, Japão) e cimenta-das com 3 biomateriais diferentes, Grupo A: cimento Autocondicionante RelyX® U200 (3M). Grupo B: cimento universal RelyX Ultimate® (3M, EUA). Grupo C: Resina termoplástificada Enamel Plus HRI® 55 ° C (Micerium). Cada espécime foi submetido a termociclagem (3300 ciclos) e colocado em uma solução de azul de metileno por 24 horas. Para a análise, foi feita uma seção longitudinal na área do meio na direção meso-distal das amostras e avaliada a microfiltração marginal em mesial e distal com a ajuda de um estéreo microscópio Olympus. Os resultados foram armazenados em um banco de dados em Excel, e os valores experimentais foram arquivados e codificados no software BioEstat (Brasil). A análise foi realizada pelo teste não paramétrico de Kruskal Wallis, com significância de 95%. Resultados: a resina termoplástificada apresentou os menores valores no grau de microfiltração com média de 0,4mm; com o cimento universal, os valores mais altos foram obtidos com média de 1,33mm, o que não foi significativo em relação ao cimento autocondicionado, com média de 0,88mm. Conclusões: foi possível determinar que nas restaurações tipo "table top" o grau de microfiltração foi menor quando cimentadas com resina termoplástica (p = <0,05), com diferença estatisticamente significante em relação aos demais cimentos. Não houve diferença na microfiltração entre os cimentos resinosos autocondicionantes em relação ao cimento resinoso universal.


Subject(s)
Dental Marginal Adaptation , Dental Leakage , Inlays , Cementation , Resin Cements , Dental Restoration, Permanent
11.
Rev. Fac. Odontol. (B.Aires) ; 33(75): 23-28, jul.-dic. 2018. ilus, tab
Article in Spanish | LILACS | ID: biblio-999892

ABSTRACT

Las coronas individuales presentan un nivel de desadaptación con las piezas dentarias que se magnifica de manera significativa en las estructuras de Prótesis Parcial Fija como son las férulas y el puente odontológico (PO). Esta desadaptación es la consecuencia geométrica de la sumatoria de errores de las cabezas de empotramiento de los PO convencionales, a la que hemos denominado un cruce angular o sinergia de errores. Para evitar dicha sumatoria de errores, hemos desarrollado un elemento protético que denominamos Perno Buje (PB) que permite, tanto en Prótesis Parcial Fija como en Prótesis Implanto Asistida, obtener más precisión con este tipo de estructuras construídas en dos piezas y soldadas en frío que con las construídas en una sola pieza. Este estudio ha demostrado una clara evidencia de que el comportamiento del PB genera una gap menor y más predecible que el PO convencional (AU)


The individual crowns show a level of teeth failure rehabilitation that is significantly magnified in partial fixed prosthesis as in splints and dental bridges. This failure, called angular cross or mistake sinergy, is the geometric consequence of the number of mistakes that conventional dental bridge fitted heads produce. In order to avoid this sum of mistakes, a prothetic element called Pin Hub has been developed. This element allows more accuracy in this kind of structures made of two pieces and cold welding than the ones made out of one piece; not only in partial fixed prothesis but also in assisted implant prosthesis. This study has proved that the Pin Hub creates a minor and more predictable gap that the one produced by a conventional dental bridge (AU)


Subject(s)
Humans , Post and Core Technique , Dental Marginal Adaptation , Denture, Partial , Prosthesis Failure , Data Interpretation, Statistical , Metal Ceramic Alloys , Dental Prosthesis, Implant-Supported
12.
Rev. cient. odontol ; 6(1): 9-18, ene.-jun. 2018. ilus, tab, graf
Article in Spanish | LILACS | ID: biblio-998741

ABSTRACT

Objetivo: Comparar la microfiltración marginal de carillas oclusales de cerómero con diferentes terminaciones: hombro, chámfer y un grupo control sin preparación. Materiales y métodos: Se utilizaron 33 dientes premolares humanos, sanos, extraídos por indicación de ortodoncia. Se dividieron en tres grupos de once por aleatorización. Una vez cementadas las carillas oclusales, las muestras fueron sometidas a un termociclado manual de 1000 ciclos, con el fin de simular el ambiente de la cavidad bucal. Después, fueron puestas en inmersión pasiva con azul de metileno al 2% por un periodo de 24 horas. Una vez culminado el tiempo, se procedió al corte de las muestras a nivel del surco central de cada pieza, con el fin de observar la microfiltración alcanzada. La microfiltración se observó con un microscopio óptico estereoscópico con aumento de lupa de 10x y se calificó según la penetración del colorante y la escala de Cassin y Pearsons modificada. Resultados: La terminación que obtuvo la mayor microfiltración fue la de hombro, con un 45% de filtración en pared axial (escala 4). El grupo con la menor filtración fue sin línea de terminación, en la cual el 72,7% se ubicó en la escala 1. La prueba de asociación de Chi cuadrado fue significativa y se obtuvo un resultado de p < 0,001. Conclusión: Existe asociación entre el aumento de microfiltración y la línea de terminación tipo hombro. Esta relación debe tenerse en cuenta al momento de la planificación de tratamiento protésico. (AU)


Objective: To compare the marginal microleakage of occlusal ceromer veneers with different finish lines; shoulder, chamfer and a group without preparation. Materials and methods:33 sound human premolars under orthodontic extraction were used. They were divided into 3 groups of 11 each. Once the occlusal veneers were bonded, they were manually thermocycled for 1000 cycles with the aim of simulating the oral cavity. They were then immersed in 2% blue methylene for 24 hours, after which cross section samples of the central groove were taken for micro-leakage observation. The microleakage was observed with an optical stereos-copic microscope with 10x magnification power and classified according to the Cassin and Pearson's modified scale. Results: The finish line with the most microleakage was the shoulder, with 45% of axial wall microleakage (scale 4). The least microleakage was observed in the group without finish line, with 72.7% (scale 1). Conclusion: The association between greater microleakage and the shoulder finish line was determined. (AU)


Subject(s)
Dental Marginal Adaptation , Dental Leakage , Dental Veneers
13.
Rev. Fac. Odontol. Univ. Antioq ; 22(2): 186-197, jun. 2011. ilus, tab
Article in Spanish | LILACS | ID: lil-598190

ABSTRACT

Introducción: el objetivo fue determinar ex vivo la adaptación marginal y ajuste interno en estructuras de zirconiaytria elaboradas con los sistemas CAD/CAM Procera® y Cerec In-lab®. Métodos: se tomaron 15 pilares protésicos prefabricados contorneados de implantes divididos en tres grupos. Se fabricaron estructuras en aleación noble Pd-Au (control), Procera AllZircon® y Cerec In-lab YZ cubes®. Para evaluar la adaptación marginal se tomaron ocho medidas en la circunferencia del pilar protésico, tomando la distancia entre el borde de la estructura y el pilar. Para determinar el ajuste interno se hicieron ocho medidas desde la superficie externa del pilar a la superficie interna de la restauración. Las mediciones fueron hechas por microscopia óptica (50X). Los datos obtenidos fueron analizados por medio del análisis de varianza de una vía, la t de Student y prueba de Dunnett. Resultados: el promedio de adaptación marginal del grupo control fue 18,24 μm ±4,81; el grupo Procera®21,62 μm ±12,15 y el grupo Cerec In-lab® de 47,34 μm ±17,72. El promedio de ajuste interno para las estructuras Pd-Au fue 34,60 μm ±16,16; Procera® 118,67 μm ±50,84 y el Cerec In-lab® 65,62 μm ±25,80. Conclusiones: los valores de adaptación marginal de las estructuras de aleación metálica y de zirconia-ytria elaboradas con los sistemas CAD/CAM Procera® y CerecIn-lab® están entre los valores clínicamente aceptables. Las medidas de ajuste interno obtenidos para los grupos aleación metálica y Cerec® se encuentran dentro del rango reportado en la literatura. Mientras que el promedio obtenido para el grupo Procera® 118,67 μm ±50,84, aunque se acercó al límite máximo de ajuste interno reportado en la literatura, no se evidenció diferencia estadísticamente significativa con el sistema Cerec In-lab®.


Introduction: the purpose of this in vitro study was to determine the marginal adaptation and internal fit in zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems. Methods: fifteen prefabricated implant abutmentswere divided in three equally sized groups; noble metal alloy Pd-Au structures were then fabricated (control group), Procera® and Cerec In-lab YZ cubes® (n = 5). The marginal gap was determined by measuring 8 points around the abutment circumferencetaking the distance between the margin of the structure and the abutment. In order to determine internal fit, 8 measures were taken from the abutment´s external surface to the internal surface of the restoration. The measures were done with an opticalmicroscope (50X). The data was the statistically analyzed using 1-way ANOVA, Student’s paired t test and Dunnett´test. Results: marginal adaptation mean for the control group was 18.24±4.81μm and Procera® 21.62 μm ±12.15 μm, while the average for Cerec In-lab® was 47.34 μm ±17.72 μm. The internal fit for the control group was 34,60 μm ±16.16 μm and Procera® group was of 118.67 μm ±50.84 μm in average and Cerec In-lab® 65.62 μm ±25.80 μm. Conclusions: the metal alloy and zirconia ytrya frameworksfabricated with Procera® and Cerec In-lab® CAD/CAM systems showed clinically acceptable marginal gap values. The internal fit values for metal alloy and Cerec® frameworks are within the ranges reported in the literature. While the mean for the Procera®group was 118.67 μm ±50.84, which is close to the internal fit maximum limit reported in the literature, there was no statistically significant difference when compared with the Cerec-In-lab® system.


Subject(s)
Biomedical and Dental Materials , Metal Ceramic Alloys
14.
Rev. salud bosque ; 1(2): 7-14, 2011. tab, ilus
Article in Spanish | LILACS | ID: lil-779436

ABSTRACT

Objetivo: comparar la adaptación marginal In Vitro de incrustaciones MOD con terminación en esmalte fabricadas con IPS e.max CAD (Computer Asisted Desing) y fabricadas en oro tipo III. Materiales y métodos: En este estudio experimental exploratorio se uso una muestra no probabilística de 15 premolares sanos por cada uno de los dos grupos; IPS e.max CAD y oro tipo III.A todos los premolares se les realizó cavidades MOD estandarizadas para los 2 grupos. Los dientes preparados fueron asignados aleatoriamente a cada grupo. Las incrustaciones del grupo IPS e.max CAD fueron elaboradas con el sistema CEREC 3 y las incrustaciones en oro fueron elaboradas por los investigadores. Se tomaron estereo microfotografías de todas las muestras sobre papel milimetrado, y las imágenes fueron analizadas mediante el programa ImageTool. Se tomaron tres medidas adaptación marginal en el área proximal mesial o distal de cada muestra, que fueron promediadas y reportadas en micras. Los datos fueron analizados mediante ANOVA y Test de Mann-Whitney. Resultados: el 98% del total de las incrustaciones en oro y el 47% del total de las incrustaciones de IPS e.max CAD presentaron una adaptación marginal < a 120 micras. El promedio de desadaptación marginal del grupo IPS e.max CAD fue 122.8 μ + 44.1, mientras que para el grupo oro fue de 75.3 μ+42,6 encontrándose diferencias estadísticamente significativas entre los dos. Conclusiones: El oro reporta mejor adaptación marginal en restauraciones inlays MOD que los sistemas maquinados como el sistema IPS e.max CAD.


Objective: To compare In Vitro, the marginal adaptation of MOD fillings with an enamel finish manufactured with IPS e.max CAD (Computer Assisted Design) and those manufactured with gold type III. Materials and methods: In this exploratory experimental study, a non-probabilistic sample of 15 healthy premolars for each of the two groups (IPS e.max CAD and gold type III) was used. Standardized MOD cavities were made in all the premolars for both groups. The prepared teeth were randomly assigned to each group. The IPS e.max CAD fillings were made using the CEREC 3 system and the gold fillings were made by the researchers. Stereo microphotographs of all the samples were taken on millimeter paper and the images were analyzed using the Image Tool software. Three marginal adaptation measurements in the mesial proximal or distal area were taken for every sample; they were averaged and reported in microns. The data was analyzed using ANOVA and the Mann-Whitney test. Results: 98% of all the gold fillings and 47% of all the IPS e.max CAD fillings showed a marginal adaptation of less than or equal to 120 microns. The marginal unfitness average for the IPD e.max CAD group was 122.8 + 44.1 μm, and for the gold fillings group it was 75.3 + 42.6 μm. There was a statistically significant differences between the groups. Conclusions: Gold reports a better marginal adaptation for inlay MOD fillings than manufactured systems like IPS e.max CAD system.


Subject(s)
Humans , Dental Marginal Adaptation , Esthetics, Dental , Inlays , Dental Restoration, Permanent
15.
Acta odontol. venez ; 46(3): 393-396, dic. 2008.
Article in Spanish | LILACS | ID: lil-630096

ABSTRACT

Cuando el factor estética es primordial, las resinas compuestas continúan siendo la opción restauradora más utilizada. Sin embargo, a pesar de su constante evolución aún presentan algunos inconvenientes, tales como: desgaste, contracción de polimerización e infiltración marginal. Actualmente, nuevos conceptos relacionados a técnicas de fotopolimerización desarrollaron una mejor adaptación marginal asociada a la permanencia de sus propiedades mecánicas. La polimerización gradual, es decir, reducción inicial de la intensidad de luz, seguida por fotoactivación con mayor intensidad han demostrado ser una alternativa con buenos resultados clínicos. Este trabajo propone discutir las principales variables que pueden interferir en el proceso de fotopolimerización, con el objetivo de alertar a los odontólogos en cuanto a la necesidad de un constante control clínico, no solamente por la observación de la técnica incremental, sino principalmente, a través de la monitorización de la cantidad de energía luminosa empleada en el proceso de fotopolimerización. En este contexto, son presentados, mediante revisión de literatura, los principales factores relacionados a la contracción de polimerización y las técnicas de fotopolimerización disponibles para minimizar sus efectos


The composite resins are still the most used restorative option when the esthetic aspect is primordial. However, even their constant evolution they present some inconvenients like: wear, polymerization contraction and marginal leakage. Today, new concepts related to light curing have developed a better marginal adaptation associated to the permanency of their mechanical properties. The gradual polymerization, which means, initial reduction at the light intensity, followed by the photoactivation with more intensity has demonstrated to be an alternative with good clinical results. This paper proposes to discuss the principal variables that could interfere at the light curing process, with the aim to alert the dentists about the necessity of a constant clinical control, not just by the observation of the incremental technique, but principally, through monitoring the quantity of light energy used at the polymerization process. In this context, are presented, by a literature revision, the principal factors related to the polymerization contraction and the available light curing techniques to minimize their effects


Subject(s)
Humans , Actin Capping Proteins/analysis , Composite Resins/analysis , Composite Resins/therapeutic use , Anesthesia, Local/methods , Esthetics, Dental
SELECTION OF CITATIONS
SEARCH DETAIL