1.
Arch. cardiol. Méx ; Arch. cardiol. Méx;94(2): 169-173, Apr.-Jun. 2024. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1556913

ABSTRACT

Resumen Objetivo: Presentar la experiencia en un país andino con el dispositivo OcclutechTM Duct Occluder para el cierre del conducto arterioso persistente. Método: Estudio observacional, retrospectivo, de corte transversal con análisis estadístico básico. Periodo: diciembre/2014 a diciembre/2022. Datos: historia clínica, informes de laboratorio de cateterismo. Resultados: Cuarenta y seis pacientes; de sexo femenino 71.3%, de sexo masculino 28.7%; edad: 0.6-38 años (mediana [Me]: 5.2); peso: 6.3-60 kg (Me: 16.5). Procedencia: andina 91.3%, costa 8.7%. Tipos de conducto arterioso persistente: E 54.4%, A 32.6%, D 13%. Diámetro ductal mínimo: 1.8-11.8 mm (Me: 3.5). Presión media de la arteria pulmonar previo a la oclusión: 14-67 mmHg (Me: 27). Índice de resistencias vasculares pulmonares previo a la oclusión: 0.28-4.9 UW/m2 (Me: 1.3). Fueron catalogados como conductos arteriosos persistentes hipertensivos seis de ellos. Tasa de oclusión: inmediata el 47.8%, a las 24 horas el 81%, a los seis meses el 100%. Tiempo de fluoroscopia: 2-13.8 minutos (Me: 4). Complicaciones: un dispositivo migrado. Seguimiento: 1-6.5 años. Conclusiones: El dispositivo OcclutechTM Duct Occluder fue efectivo y seguro para el cierre de conducto arterioso persistente tipo E, A y D en habitantes de baja y alta altitud, ya sea que estos hubieran sido niños o adultos, incluso cuando estos conductos arteriosos fueron hipertensivos.


Abstract Objective: To communicate the experience in an Andean country with the OcclutechTM Duct Occluder device for the closure of patent ductus arteriosus. Method: Observational, retrospective, cross-sectional study with basic statistical analysis. Period: December/2014 to December/2022. Data: medical chart, reports of catheterization. Results: Forty-six patients, female 71.3%, male 28.7%; age: 0.6-38 years-old (median [Me]: 5.2); weight: 6.3-60 kg (Me: 16.5). Origin: andean 91.3%, coast 8.7%. Types of patent ductus arteriosus: E 54.4%, A 32.6%, D 13%. Minimum ductal diameter: 1.8-11.8 mm (Me: 3.5). Mean pulmonary artery pressure prior to occlusion: 14-67 mmHg (Me: 27). Pulmonary vascular resistance index prior to occlusion: 0.28-4.9 WU/m2 (Me: 1.3). Six of them were classified as hypertensive patent ductus arteriosus. Occlusion rate: 47.8% immediate, 81% at 24 hours, 100% after six months. Fluoroscopy time: 2-13.8 minutes (Me: 4). Complications: a migrated device. Follow-up: 1-6.5 years. Conclusions: OcclutechTM Duct Occluder device was effective and safe for the closure of patent ductus arteriosus type E, A and D in low-altitude and high-altitude dwellers, whether they were children or adults, even when these ductus arteriosus were hypertensive.

2.
Cuad. Hosp. Clín ; 62(1): 51-56, jun. 2021. ilus
Article in Spanish | LILACS | ID: biblio-1284309

ABSTRACT

La gasometría arterial es fundamental en el diagnóstico y manejo del medio interno. El objetivo es caracterizar los valores de gasometría arterial en gestantes sanas con embarazo normoevolutivo residentes a 4 150 metros sobre el nivel del mar. Serie de casos llevada a cabo durante la gestión 2019, la cual incluye pacientes sin clínica ni antecedentes de enfermedades cardiopulmonares o hematológicas, así como ausencia de tabaquismo y residencia de al menos los últimos 6 meses. Se incluye 30 pacientes, media de edad 25.23 años (desvío estándar 3.69), con edad gestacional media de 26 semanas (desvío estándar 5.5). El valor de pH tiende a ser más alto, así como los valores de PaO2, PaCO2, HCO3 y SatpO2% son más bajos, incluso en comparación con adultos sanos residentes de la misma altitud. Existe cierta tendencia positiva hacia el incremento progresivo del pH mientras la edad gestacional avanza. La gasometría arterial en la altura, debe ser interpretada con suma precaución en relación a las condiciones barométricas, proporcionándose así, valiosa información con aplicación a la obstetricia crítica a muy alta altitud.


Arterial blood gases analysis is essential in the diagnosis and management of pathologies. The objective is to characterize arterial blood gases values in healthy pregnant residents at 4150 meters above sea level. Series case performed during 2019, including patients without a clinical features or antecedents of cardiopulmonary or hematological diseases as well as absence of smoking and residence for at least the last 6 months. Thirty patients are included, mean age 25.23 years (standard deviation 3.69), with average gestational age of 26 weeks (standard deviation 5.5). The pH tends to be higher, as well as the values of PaO2, PaCO2, HCO3 and SatpO2% are lower, even compared to healthy adults living at the same altitude. There is some positive trend towards progressive pH is higher such as gestational age progresses. Arterial gas blood analysis at altitude, should be interpreted with extreme caution in relation to barometric conditions, thus providing, valuable information to critical care obstetrics at very high altitude


Subject(s)
Humans , Female , Pregnancy , Adult , Blood Gas Analysis , Atmospheric Pressure , Gestational Age , Sea Level , Pregnant Women , Obstetrics
3.
Cuad. Hosp. Clín ; 61(1): [12], jul. 2020. ilus.
Article in Spanish | LILACS, LIBOCS | ID: biblio-1118900

ABSTRACT

INTRODUCCIÓN: la presión barométrica determina la presión parcial de los gases tanto en el medio ambiente como a nivel alveolar pulmonar, por lo que, para una determinada presión barométrica, la presión de oxígeno y dióxido de carbono es distinta. OBJETIVO: el objetivo del presente estudio es caracterizar los valores de gasometría arterial en residentes adultos sanos a muy alta altitud en la ciudad de El Alto. METODOLOGÍA: Estudio serie de casos, realizado durante la gestión 2019 en 22 (73%) mujeres y 8 varones (27%), con una media de edad de 36.07 años. El estudio contó con la aprobación del Comité de Ética Hospitalario. RESULTADOS: a 4150 metros sobre el nivel del mar, el pH tiende hacia la alcalosis (7.43) así como la PaO2 es menor (58.69mmHg), el valor de PaCO2 (26.14mmHg) es menor correspondiente a una ciudad con mayor altitud, el valor de bicarbonato sérico (20.14mmol/L) se encuentra disminuido en compensación a la disminución de la PaCO2 y el valor de la SatO2% (91.7%) es menor al reportado a nivel del mar. Hay que destacar que el índice PaO2/FiO2 no concuerda con el cálculo realizado según la fórmula propuesta dentro de la definición de los Criterios de Berlín. Se evidencia también que, en la muestra, si bien la correlación entre la PaO2 y la SatO2% resulta como alta, no resulta perfectamente lineal. CONCLUSIÓN: resulta imperativo precisar las características propias a la fisiología correspondientes a cada altitud, buscando aplicar parámetros propios como los de la gasometría arterial para el tratamiento de las enfermedades prevalentes en cada región, así como desarrollar investigaciones específicas a gran altura, ensayar posibilidades y documentarlas.


INTRODUCTION: barometric pressure determines the partial pressure of gases both in the environment and at the pulmonary alveolar level, so for a given barometric pressure, the pressure of oxygen and carbon dioxide is different. The objective of this paper is to characterize arterial blood gas values in healthy adult residents at very high altitude in the city of El Alto. METHODOLOGY: case series study, carried out during 2019; 22 volunteers (73%) women and 8 men (27%), mean age 36.07 years are included. The study was approved by the Hospital Bioethics Committee. RESULTS: at 4150 meter above sea level, pH tends towards alkalosis (7.43) as well as PaO2 is lower (58.69mmHg), the value of PaCO2 (26.14mmHg) is lower corresponding to a city with higher altitude, the value of serum bicarbonate (20.14mmol/L) is lower in compensation at the decrease in PaCO2 and the value of SatO2% (91.7%) is lower than that reported at sea level. The PaO2/FiO2 index does not match the calculation made according to the proposed formula within the definition of the Berlin Criteria. It is also evident that, although the correlation between PaO2 and SatO2% is high, it is not perfectly linear. CONCLUSION: it is imperative to precise the characteristics corresponding to the physiology corresponding to each altitude, looking forward to apply these parameters, such as those of arterial blood gas, in the treatment of prevalent diseases for each region, and so as develop specific studies at high altitude, also testing and reporting them.


Subject(s)
Male , Female , Adult , Atmospheric Pressure , Blood Gas Analysis , Altitude , Blood