Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 5152-5154, 2015.
Article in Chinese | WPRIM | ID: wpr-501324

ABSTRACT

OBJECTIVE:To establish a method to determinate the content of paeoniflorin in Bailing tablet,and to evaluate the uncertainty of results. METHODS:HPLC was performed on the column of Platisil C18 with mobile phase of water- acetonitrile(87:13,V/V) at a flow rate of 1 ml/min,the detection wavelength was 230 nm,the column temperature was 25 ℃ and the injection volume was 10 μl. Quantitative analysis was conducted for the processes and procedures and the uncertainty was evaluated. RESULTS:The linear range of paeoniflorin was 0.100 1-2.502 8 μg;RSDs of precision,stability and reproducibility tests were lower than 2.0%,recovery rate was 98.7%-100.9%(RSD=0.86%,n=6). Reference substance amount,elution produce and the accuracy of method had great effect on the uncertainty. CONCLUSIONS:The established method can be used for the content determination of paeoniflorin in Bailing tablet,and the uncertainty evaluation provides reliability for the method.

SELECTION OF CITATIONS
SEARCH DETAIL