Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Braz. dent. sci ; 18(3): 98-106, 2015. ilus, tab
Article in English | LILACS, BBO | ID: lil-772993

ABSTRACT

Muitos sistemas adesivos foram desenvolvidos na última década. O objetivo desse estudo foi avaliara resistência adesiva ao cisalhamaneto (RAC)de bráquetes ortodônticos aderidos com primer convencional (PC) ou primer auto-condicionante (PAC), submetidos à ciclagem térmica (CT) e ciclagem térmico-mecânica (CTM). Incisivos bovinos (n =90)foram randomicamente divididos em 2 grupos (n =45) para a colagem dos bráquetes: XT (Transbond XT, 3M-Unitek, CA, USA); SEP (Transbond Plus SEP,3M-Unitek, CA, USA). Após o procedimento adesivo os grupos forma subdivididos em 3 sub-grupos: SC(sem ciclagem) – 1 e 4 (n =15 cada); CTM (ciclagem térmico-mecânica)- 2 e 5 (n = 15 cada); CT (ciclagem térmica)- 3 e 6 (n = 15 cada). Um simulador de fadiga térmica foi usado para os subgrupos 3 e 6, que fioram submetidos a 500 ciclos térmicos entre 5 and 55 C (ISO 11405). Os subgrupos 2 e 5 foram submetidos à ciclagem térmico-mecânica em um simulador de fadiga. Os espécimes foram colocados em uma basede metal num ângulo de 45 e os braquetes receberam impulsos de 1 bar e 4 Hz de frequência, por uma agulha de metal de 2.5 mm de diâmetro fixada na haste superior do equipamento. Foram submetidos a 100.000 ciclos mecânicos e 500 ciclos térmicos entre 5 and 55 C. O teste de RAC foi realizado emuma máquina universal de testes (1mm/min). Após orompimento da união foi realizada uma avaliação emmicroscopia óptica para avaliar a penetração adesivae o Índice de Permanência do Adesivo (IPA) sobreo esmalte. Os resultados mostraram maiores valores de RAC (14,70 ± 4,85 MPa) para o SEP. A CT não influenciou os resultados para o XT (NC- 11,44 MPa;TC - 11,20 MPa; TMC - 11,19 MPa), enquanto para oSEP, a CTM mostrou maiores valores (16,84 MPa)...


Several adhesive systems have been developed in the last decade. The aim of the current studywas to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with conventional primers (XT) or self-etching primers (SEP), by means of thermocycling (TC) and thermomechanical(TM) procedures. 90 bovine incisors were randomly divided into 2 groups (45 specimens each) for brackets bonding: XT (Transbond XT, 3M-Unitek,CA, USA); SEP (Transbond Plus SEP, 3M-Unitek,CA, USA). After bonding, groups were divided into 3subgroups: NC (no cycling)- 1 and 4 (n = 15 each),TMC – 2 and 5 (n =15 each); and TC- 3 and 6 (n=15 each). The fatigue simulator was used for thethermal fatigue test of groups 3 and 6, which were submitted to thermal variation cycles - 500 cyles were carried out in between 5 and 55 C ( ISO 11405). Groups 2 and 5 were submitted to thermomechanicaltests by using the mechanical fatigue simulator. Thespecimens were placed at a metal base at an angleof 45, in a way that the 2.5 mm diameter metalneedle was fixed in the upper part of the cyclingmachine and could induce impulses of 1 bar loadintensity and 4 Hz frequency (4 cycles per second)on the bracket. The samples were submitted to 100000 mechanical cycles and 500 thermal cycles which varied from 5C to 55C. The SBS test was performed in a universal testing machine (1 mm/min). Afterdebonding, optic microscopic evaluation for adhesive penetration and Adhesive Remaining Index (ARI)analyses in the enamel surface were performed.The results showed higher SBS (14.70 ± 4.85 MPa)values for SEP. The SBS remained similar despitecycling (NC-11.44 MPa; TC-11.20 MPa; TMC-11.19MPa) for XT, meanwhile for SEP, ...


Subject(s)
Cattle , Orthodontic Brackets , Shear Strength , Materials Testing
2.
Braz. dent. sci ; 18(2): 19-30, 2015. ilus, tab, graf
Article in English | LILACS, BBO | ID: lil-766809

ABSTRACT

Objetivo: Este estudo avaliou o efeito do glazeamento e da ciclagem térmica na resistência à flexão biaxial e na dureza Vicker’s de diferentes materiais à base de zircônia. Material e Métodos: Espécimes de disco (15 mm x 1,15 mm) de zircônia foram confeccionados usando 3 sistemas (ZirkonZahn, Cercon, Ceramill) de acordo com a recomendação de cada fabricante. Os espécimes de cada sistema cerâmico foram randomicamente divididos em 2 grupos. Enquanto metade dos espécimes foram glazeados, a outra metade permaneceu não glazeado. Adicionalmente, cada grupo foi divido em 4 subgrupos submetidos a diferentes ciclagens térmicas (0-control, 1000, 3000, 5000 ciclos, 5-55 ºC). A resistência à flexão biaxial foi realizada em uma máquina de teste universal (1 mm/min). As amostras não glazeadas foram submetidas a microdureza Vicker’s antes e após a ciclagem térmica (0-control, 1000, 3000, 5000 cycles, 5-55 ºC). Os dados foram estatisticamente analisados usando ANOVA 1-fator, ANOVA 2-fatores e teste de Tukey’s (p < 0,05). Resultados: Nas amostras não cicladas (1104-1388 MPa), o glazeamento reduziu significativamente a resistência à flexão biaxial de todos os sistemas cerâmicos (845.65-897.35 MPa) (p = 0,000). Enquanto nos grupos não glazeados todas as modalidades de ciclagem térmica reduziram significantemente a resistência à flexão biaxial (864- 1156 MPa) (p = 0,000), nos grupos glazeados a ciclagem térmica não afetou os resultados (829.4- 854.9 MPa) (p = 0,405). Comparados aos grupos não envelhecidos (1414.1 VHN), a ciclagem térmica reduziu significantemente a dureza Vickers apenas para o Cercon (1365.9 VHN) (p = 0,005). Conclusão: O glazeamento reduz a resistência à flexão biaxial dos sistemas à base de zircônia testados. As amostras não glazeadas foram mais afetadas pela ciclagem que as amostras glazeadas. Estas informações podem ter relevância clínica na durabilidade de reconstruções em zircônia monolítica.


Objective: This study evaluated the effect of glazing and thermal cycling on biaxial flexural strength and Vickers hardness of different zirconia framework materials. Material and Methods: Disc shaped zirconia specimens (15 mm x 1.15 mm) were fabricated using three systems (ZirkonZahn, Cercon, Ceramill) according to each manufacturer`s instructions. The specimens of each system were randomly divided into 2 groups. While half of the specimens were glazed, the other half was left unglazed. Each group was further divided into 4 subgroups to be subjected to thermal cycling (0-control, 1000, 3000, 5000 cycles, 5-55 ºC). Biaxial flexural strength was tested in a universal testing machine (1 mm/min). Unglazed zirconia specimens were subjected to Vickers microhardness with and without thermal cycling (0-control, 1000, 3000, 5000 cycles, 5-55 ºC). Data were statistically analyzed using one-way ANOVA, twoway ANOVA and Tukey’s test (p < 0.05). Results: In non-aged conditions (1104-1388 MPa), glazing significantly decreased the biaxial flexural strength of all zirconia ceramics (845.65-897.35 MPa) (p = 0.000). While in the non-glazed groups, all thermal cycling regimens significantly decreased the biaxial flexural strength (864 -1156 MPa) (p = 0.000), in glazed groups thermal cycling did not affect the results (829.4-854.9 MPa) (p = 0.405). Compared to the non-aged group (1414.1 VHN), thermal cycling decreased the Vickers hardness significantly only for Cercon (1365.9 VHN) (p = 0.005). Conclusion: Glazing decreased the biaxial flexural strength of the zirconia ceramics tested. Unglazed zirconia ceramics were weaker against thermal cycling compared to glazed ones. For the long-term durability of monolithic zirconia reconstructions, this information may have clinical significance.


Subject(s)
Tensile Strength , Vitrification
3.
Arch. oral res. (Impr.) ; 7(1): 17-26, jan.-abr. 2011. ilus, tab
Article in English | LILACS, BBO | ID: lil-667648

ABSTRACT

Objective: The purpose of this study was to compare the microleakage of four cements in cast post-andcoresystems under cyclic loading. Materials and methods: Sixty-four human premolars were sectionedat the cement-enamel junction, endodontically treated, and divided into four groups (n = 16). Cast postsand cores were fabricated for root segments and were cemented with zinc phosphate cement (Harvard),resin-modified glass ionomer (Fuji PLUS), dual-cured phosphate methacrylate resin cement (Panavia F),or a dual-cured resin cement (Variolink II). All specimens underwent thermal cycling for 1.500 cycleswith 5 °C and 55 °C, with a dwelling time of 12 seconds. Half of the specimens of each group were subjectedto cycling loading with 50 N at 1.2 Hz for 750,000 cycles. Specimens were then immersed in 5%basic fuchsin solution for 24 hours. Specimens were sectioned, visualized by stereomicroscope under40x magnification and scored for dye penetration. The ratio between the length of the interface and thelength of dye penetration was also determined. Microleakage differences between the four cements were analyzed by Kruskal-Wallis test, and the effect of fatigue was analyzed with Mann-Whitney nonparametrictest (α =.05). Results: No failures occurred during fatigue testing. The zinc phosphate cement showedsignificantly higher microleakage values compared to other cements under both unloaded and loadedconditions (p = .007 and p = .006). Fatigue significantly increased the microleakage in all groups (p < .05).Conclusions: The microleakage values for the resin cements and the resin-modified glass ionomer weresimilar and significantly less than those of zinc phosphate, irrespective of loading. Fatigue loading increasedthe microleakage values for all the cements.


Objetivo: O objetivo deste estudo foi comparar a microinfiltração de pinos e núcleos de preenchimento metálicoscimentados com quatro diferentes materiais. Materiais e Métodos: 64 pré-molares humanos foram seccionadosna junção cemento-esmalte, tratados endodonticamente e divididos em quatro grupos (n = 16). Pinos enúcleos metálicos fundidos foram fabricados e cimentados com cimento de fosfato de zinco (Harvard), cimentode ionômero de vidro modificado (Fuji Plus), cimento resinoso dual de metacrilato fosfato (Panavia F) e cimentoresinoso dual (Variolink II). Todos os espécimes foram submetidos à ciclagem térmica (1.500 ciclos a 5-55 °C, 12segundos de banho). Metade dos espécimes de cada grupo foi submetida a uma carga cíclica de 50 N a 1,2 Hz emum total de 750.000 ciclos. Após a ciclagem, os espécimes foram imersos em solução de fucsina básica 5% por24 horas, seccionados, visualizados sob aumento de 40x e ranqueados quanto à penetração do corante. A proporçãoentre o comprimento da interface e o comprimento da penetração do corante foi também determinada.As diferenças de infiltração entre os quatro cimentos foram analisadas por teste de Kruskal-Wallis e o efeito dafadiga foi analisado por teste não paramétrico de Mann-Whitney (α = 0,05). Resultados: Não ocorreram falhasdurante o teste de fadiga. O cimento de fosfato de zinco mostrou valores de infiltração significativamente maiorescomparados aos demais cimentos na ausência ou presença da fadiga (p = 0,007 e p = 0,006). A fadiga elevousignificativamente a microinfiltração em todos os grupos (p < 0,05). Conclusões: Os valores de microinfiltraçãopara os cimentos resinosos e para o cimento de ionômero de vidro modificado foram similares e inferiores àquelesdo cimento de fosfato de zinco, independente da aplicação do teste de fadiga. A fadiga elevou os valores de microinfiltraçãopara todos os cimentos.


Subject(s)
Humans , Dental Cements/chemistry , Dental Leakage , Dental Pins , Dental Stress Analysis , In Vitro Techniques , Post and Core Technique , Materials Testing , Statistics, Nonparametric , Surface Properties , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL